PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Capture”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Molecular nanosprings in spider capture-silk threads.

Spider capture silk is a natural material that outperforms almost any synthetic material in its combination of strength and elasticity. The structure of this remarkable material is still largely unknown, because spider-silk proteins have not been crystallized. Capture silk is the sticky spiral in the webs of orb-weaving spiders. Here we are investigating specifically the capture spiral threads from Araneus, an ecribellate orb-weaving spider. The major protein of these threads is flagelliform protein, a variety of silk fibroin. We present models for molecular and supramolecular structures of flagelliform protein, derived from amino acid sequences, force spectroscopy (molecular pulling) and stretching of bulk capture web. Pulling on molecules in capture-silk fibres from Araneus has revealed rupture peaks due to sacrificial bonds, characteristic of other self-healing biomaterials. The overall force changes are exponential for both capture-silk molecules and intact strands of capture silk.

Animals↗

Relationship between anti-neutrophil cytoplasmic antibody determined with conventional binding and the capture assay, and long-term clinical course in vasculitis.

OBJECTIVES: To evaluate the relationship between anti-neutrophil cytoplasmic antibody (ANCA) measured with two different methods and long-term clinical course in vasculitis. DESIGN: Retrospective determination of ANCA with two different assays for detection of PR3-ANCA, conventional direct binding ELISA and capture ELISA using monoclonal antibodies against PR3. The 245 ANCA determinations were performed from frozen blood samples collected three to four times a year in each patient. SETTING: Department of Nephrology at a Swedish University Hospital. SUBJECTS: A total of 10 ANCA-positive patients with vasculitis caused by Wegener's granulomatosis (WG) or microscopic polyarteritis (MPA) and a very long follow-up time (mean 9 years, range 5-15.5 years). RESULTS: The total number of episodes with active vasculitis was 29 and all of them (100%) were detected by the capture technique whilst the conventional technique detected 23 (79%). The mean number of episodes with active disease requiring treatment with steroids and cytotoxic drugs was three per patient (range 1-6). At the time of clinical relapse of the vasculitis disease, the ANCA titre using the capture technique was either increasing or showed a very high value in all cases. The pattern of capture ANCA response could be subdivided into three categories: a close (four patients), an intermediate (three patients), and no (three patients) relationship between capture ANCA level and long-term clinical course. CONCLUSION: Detection of PR3-ANCA by the capture ELISA showed a higher sensitivity than that obtained by the direct ELISA in diagnosing relapse during follow-up of patients with vasculitis. The specificity of the capture ANCA was, however, low, as high levels occurred in patients without clinical disease activity.

Adult↗

Delayed acute capture myopathy in three roe deer.

Delayed acute capture myopathy is the term used to describe the clinical syndrome observed in three roe deer captured by drive-nets and transported to an enclosure for scientific purposes. The animals died 48 h, 60 h and 8 days after being captured. The simultaneous deaths coincided with a previous episode of deliberate human disturbance. The histopathological findings were indicative of acute myopathy and myoglobinaemic nephrosis. These could be related to an ataxic myoglobinuric syndrome brought on by capture and transport operations. The lack of clinical signs and negative prognosis indicators in the period between capture and just before death. the absence of gross muscular lesions in the animal that died after 8 days post-capture, the simultaneous deaths of animals captured at different times and the evidence of deliberate human disturbance in the enclosure are suggestive of death triggered by a second stress episode.

Acute Disease↗

Determination of pacing capture in implantable defibrillators: benefit of evoked response detection using RV coil to can vector.

Automatic detection of capture in ICDs would be useful for ensuring normal pacing function and lead integrity and may increase device longevity. Evoked response detection can be difficult due to postpace polarization. Polarization on the RV coil to can vector, however, should be absent when pacing with a true bipolar lead (pace tip to ring). Polarization on the RV coil to can vector should be low in an integrated bipolar lead due to the large surface area of the coil. Ventricular-paced responses were prospectively recorded in 20 patients during ICD implantation or replacement. Capture and loss of capture responses were noted during threshold searches with electrograms recorded between the RV coil and can. A detector was designed to discriminate between capture and noncapture-paced responses using data from the first 11 patients and validated on the remaining 9. The detector had a sensitivity of 99.9% (detected capture on capture beats), and had a specificity of 100% (detected no capture on noncapture beats) for all lead configurations. There was no measurable polarization with true bipolar leads. In integrated bipolar leads, maximum polarization ranged from 0.0 to 16.7 mV. In conclusion, paced evoked responses can be detected in ICDs using the RV coil to can vector using standard pacing waveforms. Special polarization reducing pacing waveforms are not required. These observations could be used to design ICDs with automatic pacing threshold detection.

Adolescent↗

Atrial evoked response integral for automatic capture verification in atrial pacing.

Beat-by-beat Autocapture is currently limited to operation in the ventricle with bipolar leads. The authors investigated the integral of the negative-going portion of the atrial evoked response integral (AERI) as a potential resource for verification of atrial capture. Intracardiac electrogram signals were collected from 59 patients (ages 67.8 +/- 15.1 years) with bipolar, low polarization atrial leads. The signals were collected over a mean period of 6.1 months (minimum 4 days) after lead implantation. St. Jude Medical Affinity pulse generators were used to perform automatic capture threshold tests while the electrogram signals were recorded by a Model 3510 programming device. These signals were transferred to a personal computer in digital form for later analysis. The AERI was calculated at each programmable pacing voltage until capture was lost. The difference between the polarization integral at loss of capture and evoked response integral with successful capture was sufficient to justify enabling the atrial Autocapture feature in 53 of 59 patients in whom bipolar pacing and unipolar sensing was performed. The authors developed a calibration routine to identify automatically those patients in whom atrial Autocapture could be programmed On, based on the polarization integral at loss of capture, the estimated maximum polarization integral, and the AERI. Preliminary analysis indicated that the AERI is a practical resource for beat-by-beat atrial capture detection when used with low polarization leads.

Aged↗

Treating Japanese quail with vitamin C does not facilitate their capture by the experimenter.

1. Vitamin C supplementation reduces fear of novel situations and of people. The present study examined its effects on the ease of capture of male Japanese quail by the experimenter. 2. At 20 d of age, quail received either vitamin C (ascorbyl-2-polyphosphate, APP, 1 g L-ascorbic acid/l) solution or untreated drinking water (UDW) for 24 h before they were mixed in 2 groups of 40 (20 APP + 20 UDW. All the birds in 1 group were caught individually by an unsighted experimenter whereas a sighted catcher captured the others. The bird's identity was noted each time. This capture/recapture procedure was repeated 6 times for each group (12 capture trials per bird) and an overall capture rank across all 12 trials was assigned to each bird. 3. Regardless of whether the catcher was sighted or unsighted, the mean ranks of neither APP nor UDW quail differed significantly from the value expected by chance. Neither were there any linear trends in the effects of repeated testing. Thus, prior treatment with vitamin C neither facilitated nor hindered capture. 4. Body weights were similar in both treatment groups and there were no significant intra-individual correlations between body weight and capture rank. 5. Highly significant tendencies were found for individual birds to be caught at similar stages of each capture trial regardless of treatment or test situation. This finding sounds a cautionary note for all studies involving putatively random sampling of a population.

Animals↗

Influence of stress of capture on haematological values and cellular immune responses in the Australian brushtail possum (Trichosurus vulpecula).

Possums (Trichosurus vulpecula) captured for the first time (single-capture) had significantly lower blood lymphocyte and eosinophil counts, but higher neutrophil counts than possums which had been captured frequently. Single-capture possums also had depressed lymphocyte responses to concanavalin A (males and females) and pokeweed mitogen (males only). The haematological changes and the depressed lymphocyte reactivity to the T-cell mitogens were consistent with the animals being in a stressed state following capture for the first time. The haematological profile of single-capture possums changed to a profile similar to that of the frequently captured possums following housing in cages for 1 week, and high lymphocyte responses to T-cell mitogens were recorded following housing for 3-5 weeks. This information, together with body weight data, indicates that a minimum of 4 weeks adaptation to housing in cages should be allowed before possums are used in experimental studies.

Journal Article↗

Interpreting the relationship between pheromone component emission from commercial lures and captures of Helicoverpa zea (Boddie) in bucket and cone traps.

Male corn earworm moths, Helicoverpa zea (Boddie), were captured in conical Texas pheromone traps (cone traps) and bucket traps baited with four different commercial lures manufactured by three different manufacturers. Because significant numbers were captured in bucket traps baited with some of the lures, and none with others, the volatile emissions from all of the lures were sampled and analyzed by gas chromatographic methods. The numbers of males captured in two types of trap were compared with bait emissions in an endeavor to define a more effective lure for bucket traps. The lure from one manufacturer captured the same numbers of males in both trap types; one captured more in bucket traps than in cone traps, and another captured only a small number in bucket traps. The emission rate of all active compounds from each of the different lures was approximately linear for the duration of the assays. A gas-liquid chromatographic peak associated with a third compound, (Z)-9-tetradecenal, which reduces behavioral responses, was observed in the emissions from all lures evaluated. The effectiveness of the Hercon (Emmigsville, PA) lure in capturing males in both types of trap was associated with a lower emission of (Z)-11-hexadecenal, (Z)-9-hexadecenal and (Z)-9-tetradecenal than from the other lures.

Agriculture↗

N capture by Plantago lanceolata and Brassica napus from organic material: the influence of spatial dispersion, plant competition and an arbuscular mycorrhizal fungus.

This study investigated N capture by Plantago lanceolata L. and Brassica napus L. from complex organic material (dual-labelled with 15N/13C) added either as a thin concentrated layer (discrete patch treatment) or dispersed uniformly with the background sand:soil mix in a 10 cm band (dispersed treatment) when grown in monoculture or in interspecific competition and in the presence or absence of a mycorrhizal inoculum (Glomus mosseae). No 13C enrichments from the organic material were detected in the plant tissues, but 15N enrichments were present. Total plant uptake of N from the organic material on a microcosm basis was not affected by the spatial placement of the organic material, but Plantago monocultures captured less N than the species in interspecific competition (i.e. 23% versus 38% of the N originally added). N capture from Brassica monocultures was no different to either Plantago monocultures or both species in mixture. However, N capture from the organic material by both individual Plantago and Brassica plants was reduced when grown with Brassica plants (by 10-fold and by more than half, respectively). N capture from the organic material was directly related to the estimated root length produced in the sections containing the organic material: the individual that produced the greatest root length captured most N. Strikingly, when the organic material was added as a discrete patch the N captured by Brassica, a non-mycorrhizal species, actually increased when the G. mosseae inoculum was present compared to when G. mosseae was absent (i.e. 35% versus 19% of the N originally added).

Brassica napus↗

Use and limitations of the capture-recapture method in disease monitoring with two dependent sources.

Capture-recapture techniques are employed increasingly to correct for underascertainment of cases in epidemiologic surveillance. A key assumption of the basic two-source capture-recapture method is the independence of sources, which is often violated in practice. This paper provides a quantitative comparison of the performance of the capture-recapture method and the traditional registration approach in disease monitoring with two dependent sources. If sources are negatively dependent, underascertainment of cases by the traditional registration approach is transformed into overestimation of case numbers with the capture-recapture method. This overestimation can be extreme under certain conditions. Application of the capture-recapture method is therefore discouraged if negative source dependence is of concern. In other situations, the capture-recapture method can be a valuable tool to correct for underascertainment of cases. Although the correction remains imperfect if notifications from both sources are positively dependent, underestimation of case numbers is typically much less severe than with the traditional registration approach. I illustrate the findings for a broad range of registration scenarios and provide empirical examples from population-based cancer registration. I also discuss strategies that may minimize the degree of source dependence in the design and analysis of capture-recapture studies.

Cross-Sectional Studies↗

Strong evidence for enhanced multiple electron capture from surfaces in 46 MeV/u Pb81+ collisions with thin carbon foils.

Strong evidence has been found for enhanced multiple electron capture into 46 MeV/u Pb81+ with a significant contribution from the entrance surface of thin carbon foils. Capture of up to five electrons has been observed. The multiple electron capture yield is found to increase with decreasing target thickness for thin targets. A simple model describing the data and showing the importance of capture from surfaces is discussed. Further evidence is found for a pronounced asymmetry between electron capture at the entrance and the exit surfaces. Absolute yields for multiple electron capture and projectile ionization are presented. The experimental total cross sections for single capture and ionization agree well with theory.

Journal Article↗

Development and evaluation of capture enzyme-linked immunosorbent assays for detection of immunoglobulin G and M antibodies to group A streptococcal antigens.

Capture enzyme-linked immunosorbent assays (ELISAs) were developed to detect immunoglobulin G and M antibodies to group A streptococcal (GAS) antigens, streptolysin O, streptokinase, and group A carbohydrate. The sensitivities and the specificities of the IgM capture ELISAs to each GAS antigen were high enough to distinguish the patients with GAS infections (diagnosed as GAS pharyngitis or scarlet fever) from the control groups (healthy people and patients with pharyngitis from whom GAS could not be isolated). On the other hand, the specificities of the IgG capture ELISAs were not very effective in diagnosis of GAS infections. When the capture ELISA and an indirect ELISA detecting IgM antibodies to group A carbohydrate were compared, false-positive reactions due to rheumatoid factor occurred in the indirect ELISA, but did not occur in the capture ELISA. These results indicate that the capture ELISA works better than the indirect ELISA in detecting the IgM antibody, and that the IgM capture ELISA to GAS antigen provides a rapid and highly reliable serodiagnosis for GAS infections employing only a single serum.

Adolescent↗

Evaluation of fusion beat detection with a new ventricular automatic capture algorithm in ICDs.

This study evaluated a newly developed automatic capture verification scheme for implantable cardioverter defibrillators (ICDs) regarding discrimination of capture, fusion, and noncapture beats, with an emphasis on fusion detection. The algorithm uses evoked response detection based on a sensing vector from right ventricular shocking coil to Can. Patients undergoing ICD implant or replacement were enrolled in this study. An external system was used for pacing and data acquisition. To provoke ventricular fusion beats, VVI patients were paced close to the rate of their intrinsic rhythm and DDD patients were paced close at their intrinsic PR interval. Surface ECG and wideband filtered intracardiac electrograms were recorded for off-line analysis. Each paced beat was independently classified visually by surface ECG and by the automatic detection algorithm. The algorithm performance was then evaluated by comparing the classification results. Twenty-seven patients (22 males, 5 females; 63.8 +/- 12.5 years) were analyzed. Device and lead demographics were: 18 DDD/9 VVI; 16 dedicated bipolar, 11 integrated bipolar leads; 18 acute, 9 chronic (3.7 +/- 2.0 years) leads. In total, 2064 beats were analyzed, including 1,477 fusion beats and 587 capture beats. Fusion detection sensitivity and specificity were 99.5% and 99.0%, respectively. Seven true-fusion beats (0.5%) were classified as capture and 6 capture beats (1.0%) were identified as fusions. Capture or fusion beats were never detected as non-capture beats. It is concluded that the algorithm was effective in detecting fusion beats. It could potentially be used in ICD applications that need accurate fusion detection.

Algorithms↗

Anodal right ventricular capture during left ventricular stimulation in CRT-implantable cardioverter defibrillators.

BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to improve symptoms of patients with moderate to severe heart failure. Optimal CRT involves biventricular or left ventricular (LV) stimulation alone, atrio-ventricular (AV) delay optimization, and possibly interventricular timing adjustment. Recently, anodal capture of the right ventricle (RV) has been described for patients with CRT-pacemakers. It is unknown whether the same phenomenon exists in CRT systems associated with defibrillators (CRT-ICD). The RV leads used in these systems are different from pacemaker leads: they have a larger diameter and shocking coils, which may affect the occurrence of anodal capture. METHODS: We looked for anodal RV capture during LV stimulation in 11 consecutive patients who received a CRT-ICD system with RV leads with a true bipolar design. Fifteen patients who had RV leads with an integrated design were used as controls. Anodal RV and LV thresholds were determined at pulse width (pw) durations of 0.2, 0.5, and 1.0 ms. RESULTS: RV anodal capture during LV pacing was found in 11/11 patients at some output with true bipolar RV leads versus 0/15 patients with RV leads with an integrated bipolar design. Anodal RV capture threshold was more affected by changes in pw duration than LV capture threshold. In CRT-ICD systems, RV leads with a true bipolar design with the proximal ring also used as the anode for LV pacing are associated with a high incidence of anodal RV capture during LV pacing. This may affect the clinical response to alternative resynchronization methods using single LV stimulation or interventricular delay programming.

Adult↗

Sensorimotor model of bat echolocation and prey capture.

A model of the bat sensorimotor system is developed using acoustics, signal processing, and control theory to illustrate the fundamental issues in accomplishing prey capture with echolocation. This model indicates that successful nonpredictive tracking of an ideal prey can be accomplished with a very simple system. Circular apertures approximate the mouth and ears for deriving acoustic beam patterns, using the big brown bat Eptesicus fuscus as a model. Fundamental and overtone frequency components in the emissions allow two simultaneous acoustic beams to be defined. A pair of nonlinear, time-variable, sampled-data controllers alter the bat's heading by applying yaw and pitch heading corrections. The yaw correction attempts to position the prey in the midsagittal plane by nulling the interaural intensity difference of the fundamental component. The pitch correction compares the intensities of the overtone and fundamental components and acts to null their difference. By initiating pitch correction when the overtone intensity first exceeds that of the fundamental, the ambiguity problem is solved and the prey is directed to the capture region. Simulations of passive prey capture indicate that the capture probability decreases as the prey speed increases. Both quick and sluggish prey are considered, with sluggish prey found to be caught with slightly better efficiency. The magnitude of the prey's lateral motion just prior to capture is observed to be an important factor determining capture. The presence of a blind stage is considered, during which the interference of the emission with the echo is assumed to disrupt any sonar information. The presence of such a blind stage is found to have negligible effect on capture efficiency.

Acoustics↗

Peptide aMptD-mediated capture PCR for detection of Mycobacterium avium subsp. paratuberculosis in bulk milk samples.

A peptide-mediated capture PCR for the detection of Mycobacterium avium subsp. paratuberculosis in bulk milk samples was developed and characterized. Capture of the organism was performed using peptide aMptD, which had been shown to bind to the M. avium subsp. paratuberculosis MptD protein (J. Stratmann, B. Strommenger, R. Goethe, K. Dohmann, G. F. Gerlach, K. Stevenson, L. L. Li, Q. Zhang, V. Kapur, and T. J. Bull, Infect. Immun. 72:1265-1274, 2004). Consistent expression of the MptD receptor protein and binding of the aMptD ligand were demonstrated by capturing different Mycobacterium avium subsp. paratuberculosis type I and type II strains and subsequent PCR analysis using ISMav2-based primers. The analytical sensitivity of the method was determined to be 5 x 10(2) CFU ml(-1) for artificially contaminated milk. The specificity of aMptD binding was confirmed by culture and competitive capture assays, showing selective enrichment of M. avium subsp. paratuberculosis (at a concentration of 5 x 10(2) CFU ml(-1)) from samples containing 100- and 1,000-fold excesses of other mycobacterial species, including M. avium subsp. avium and M. avium subsp. hominissuis. The aMptD-mediated capture of M. avium subsp. paratuberculosis using paramagnetic beads, followed by culture, demonstrated the ability of this approach to capture viable target cells present in artificially contaminated milk. Surface plasmon resonance experiments revealed that the aMptD peptide is a high-affinity ligand with a calculated association rate constant of 9.28 x 10(3) and an association constant of 1.33 x 10(9). The potential use of the method on untreated raw milk in the field was investigated by testing 423 bulk milk samples obtained from different dairy farms in Germany, 23 of which tested positive. Taken together, the results imply that the peptide-mediated capture PCR might present a suitable test for paratuberculosis screening of dairy herds, as it has an analytical sensitivity sufficient for detection of M. avium subsp. paratuberculosis in bulk milk samples under field conditions, relies on a defined and validated ligand-receptor interaction, and is adaptable to routine diagnostic laboratory automation.

Animals↗

Evaluation of an immunoglobulin M capture enzyme-linked immunosorbent assay for diagnosis of Orientia tsutsugamushi infection.

To differentiate scrub typhus from other acute febrile diseases, a rapid and reliable serological diagnosis is important. We developed an immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) for diagnosis of recent Orientia tsutsugamushi infections in humans. The 56-kDa major outer membrane protein of O. tsutsugamushi is well known as the most immunodominant antigen in scrub typhus. The test is based on the use of the biotinylated recombinant 56-kDa protein of O. tsutsugamushi Boryong, Bor56, which was expressed as a fusion protein with a maltose-binding protein in Escherichia coli. In the test, the serum IgM antibodies were captured by anti-human IgM antibodies coated onto a microtiter plate. The captured IgM antibodies were revealed through sequential addition of biotinylated Bor56 antigen and peroxidase-conjugated streptavidin to the plate. The IgM capture ELISA was compared with the immunofluorescence antibody assay (IFA) by testing 176 serum samples from patients with diagnosed cases of rickettsial disease and patients with other acute febrile diseases. Of the 81 IgG IFA-positive samples, 78 tested positive (sensitivity, 96.3%) and all 31 IgM IFA-positive samples tested positive (sensitivity, 100%) by the IgM capture ELISA. The specificity of the IgM capture ELISA was 99%, and 1 of the 95 IFA-negative samples was positive in the assay. These results strongly suggest that IgM capture ELISA using the recombinant Bor56 antigen is a reliable and detailed method for the detection of early O. tsutsugamushi infection.

Antibodies, Bacterial↗

Typing of herpes simplex virus by capture biotin-streptavidin enzyme-linked immunosorbent assay and comparison with restriction endonuclease analysis and immunofluorescence method using monoclonal antibodies.

A sensitive enzyme-linked immunosorbent capture assay using biotin and streptavidin (capture B/SA ELISA) was developed using type-specific monoclonal antibodies for typing of herpes simplex virus. Rabbit anti-herpes simplex virus immunoglobulin G was used as the capturing antibody, and biotin-linked type-1-specific mouse monoclonal antibody or rabbit type-1- or type-2-specific polyclonal antibody served as the detecting antibody. The captured antigen was detected by an ELISA with alkaline phosphatase-conjugated streptavidin, which reacted with biotin molecules on the detector antibody. The capture B/SA ELISA was compared with other methods for efficiency and reliability in typing. Results obtained by restriction endonuclease digestion of the radiolabeled viral genome were used to determine the type (1 or 2) of clinical isolates. These results were then used as a reference for determining the accuracy of the capture B/SA ELISA, as well as that of the immunofluorescence method, both of which are easily adaptable for use in the clinical laboratory. The three methods were in perfect agreement. It was determined that both the capture B/SA ELISA and the immunofluorescence method using monoclonal antibodies provided typing results with 100% specificity and 100% sensitivity and thus were accurate and reliable. However, the ELISA was the method of choice because of its simplicity, rapidity, and use of nonradioisotopic reagents.

Antibodies, Monoclonal↗