Microcomputer-based system for 24-hour recording of oesophageal motility and pH profile with automated analysis.

A system developed for long-term simultaneous recording of oesophageal motility and pH in the ambulant patient is described. The system consists of a microprocessor based data-acquisition and preprocessing device, a personal computer for postprocessing, report generation and data storage, a miniature two-sensor pressure catheter and a pH electrode. Identification and classification of oesophageal contractions are performed in separate steps, using online preprocessing software for identification and offline postprocessing software for categorisation, classification and report generation. Contractions are categorised as peristaltic, simultaneous or nontransmitte and classified according to their amplitude, duration and propagation velocity. The method described reduces the amount of data from 870 kbyte to approximately 40 kbyte per 24 hours in a multiparameter recording device, and offers the opportunity for offline postprocessing with different sets of criteria. The system has been found to be accurate and reliable in 24-hour studies in both healthy volunteers and patients with non-cardiac chest pain.

Adult↗

[The use of personal computers for the collection, storage and analysis of data from neurosurgical intensive care monitoring].

For data acquisition intensive care neurosurgery increasingly has recourse to modern electronics, which have become an integral part of many aspects of present-day neurosurgery. Despite their high technical standard, the devices in common use often lack flexibility. Their range of possible applications is defined by the manufacturer, and the user has little or no influence on them. Moreover, there are often no adequate interfaces to peripherals, and the storage capacity is limited. We would like to present a data acquisition system on a PC/AT basis, which operates up to 64 channels allowing parallel registration, storage, analysis, and of decisive importance, also various computations, i.e. correlation. Computation is rarely feasible on commercial devices, but it is essential for specific demands, such as implementation of PA/PM diagrams to determine intracranial compliance. In addition, the pertinent software permits implementation of Fourier analyses, offers separate statistical functions, and transfers data to other programs. The program is capable of automatic batch-processing, which greatly facilitates its use.

Computer Systems↗

Integration of a picture archiving and communication system with videocapture and computed radiography in a dental hospital.

A method for the integration of a picture archiving and communication system (PACS) at Kyushu University Dental Hospital with radiological information (RIS) and hospital information (HIS) systems is described. CT, US and DSA from different manufacturers were integrated by videocapture and then subsequently integrated with computed radiography (CR) by means of DICOM. The approximate amount of data stored each month on optical discs is 2 GB. The system does not incorporate intra-oral radiography.

Angiography, Digital Subtraction↗

Confocal fluorescence microscopy and three-dimensional reconstruction.

Several recent technological advances have considerably improved the field of confocal fluorescence microscopy. Improvements in confocal microscope design, new fluorescent probes and indicators, more sensitive imaging devices, and computer advances which allow for data manipulation and storage provide a convenient method to acquire complex three-dimensional (3-D) architectural details which previously were difficult or impossible to obtain from biological specimens. Applications of the laser scanning and tandem scanning confocal microscopes offer the potential for gaining powerful insights into the complex relationship of cellular structure and function. Confocal microscopy generates optical sections free from out-of-focus blur. With the development of new visualization tools to render and display complex 3-D data, a set of optical sections taken at different focal planes can be three-dimensionally reconstructed to create an animated sequence which can reveal latent features of the specimen. The combination of confocal microscopy and 3-D reconstruction provides a powerful new imaging tool to advance knowledge about structural and functional cellular properties as they occur dynamically in three dimensions.

Animals↗

Direct measurement of sarcomere length from isolated cardiac cells.

Isolated cardiac muscle cells enzymatically digested with collagenase and hyaluronidase from whole rat myocardium demonstrate the characteristics of an intact membrane in that they tolerate millimolar concentrations of free Ca2+ and exhibit phasic contractions with electrical excitation. These isolated cells maintain their characteristic A-I band striation patterns when at rest or during contraction. An apparatus has been developed to directly image these cells with phase-contrast micrography onto a 1,728-element charge-coupled device photodiode array for rapid data storage in a digital computer. The digitized striation pattern profile was analyzed for individual and average sarcomere spacing. In isotonic media the average resting sarcomere length ranged from 1.77 to 1.91 micrometers in 13 cells, with a mean length of 1.83 +/- 0.12 micrometers. Electrically stimulated phasic contractions in three cells demonstrated a synchronous 20% decrease in sarcomere spacing to a mean of 1.51 micrometers. Striation spacing decreased under hypertonic stress but elongated only up to 1.93 micrometers in hypotonic solutions, suggesting that some internal elastic constraint exists that limits elongation of the cell.

Animals↗

Digital archive center: implementation for a radiology department.

OBJECTIVE: In this article, we describe the implementation of a digital archive center for a radiology department in a 700-bed teaching hospital. MATERIALS AND METHODS: The archive center consists of two identical archive systems, each comprising five components: an archive server, a data-base server, an optical disk library, a stand-alone optical disk drive, and a communication network. An image management system controls the image traffic from acquisition devices to display stations. A fault-tolerant mechanism was built into the archive center to achieve a 100% uptime. RESULTS: The center has been in operation for over 6 months. We have not experienced a single total system failure during this period. It currently archives all digital images from three MR units and four CT scanners and selected images from three computed radiographic systems and two laser film digitizers. The center archives between 1.5 and 2.0 gigabytes of images per workday. CONCLUSION: With its built-in fault-tolerant mechanism, we believe that the implemented archive center is very reliable and is suitable for a radiology department to archive its digital images.

Hospital Bed Capacity, 500 and over↗

Validation of two devices for self-measurement of blood pressure by elderly patients according to the revised British Hypertension Society protocol: the Omron HEM-722C and HEM-735C.

BACKGROUND: The validation of self-measurement devices for clinical use by elderly patients has been recommended. The Omron HEM-722C device has recently been validated according to the British Hypertension Society (BHS) protocol for use for general populations and the Omron HEM-735C is a new fully automatic device with a high capacity for storage of measurements that is integrated with a personal computer. OBJECTIVE: To perform a clinical validation for use by elderly people of the Omron HEM-722C and HEM-735C devices according to the revised protocol of the BHS and the criteria of the Association for the Advancement of Medical Instrumentation (AAMI). METHODS: We carried out a main validation test according to the revised BHS protocol for validation procedures for special groups on two groups of 30 subjects aged more than 65 years (29 men and 31 women), 11 of 30 with systolic blood pressures (SBP) <110mmHg, 10 of 30 with SBP >200 mmHg, 15 of 30 with diastolic blood pressures (DBP( <70 mmHg and 10 of 30 with DBP >110 mmHg. The results were graded according to the BHS system from A to D. RESULTS: The Omron HEM 722C achieved an overall A/A grading and satisfied the AAMI criteria for accuracy whereas the Omron HEM-735C achieved an overall B/A grading and satisfied the AAMI criteria for accuracy. The sphygmomanometer measurements were 147 +/- 31/79 +/- 15 and 144 +/- 30/78 +/- 15 mmHg (means+/-SD) respectively, for the models 722C and 735C. The average differences between mercury sphygmomanometer and HEM-722C readings for SBP and DBP were, respectively, 0.76+/-5 and 0.41+/-8 mmHg; those for HEM-735C were, respectively, 0.24+/-8 and 0.9+/-8 mmHg. Readings of the HEM-722C device differed by less than 5 mmHg for 76% of systolic readings and 96% of the readings differed by less than 10 mmHg. Diastolic measurements differed by less than 5 mmHg for 71% and less than 10 mmHg for 71 and 87% of all readings. Readings of the HEM-735C device differed by less than 5 mmHg for 68% of systolic readings and 74% of the readings differed by less than 10 mmHg. Diastolic measurements differed by less than 5 mmHg in 74% and less than 10 mmHg in 88 and 87% of all readings. CONCLUSIONS: On the basis of these results, for elderly subjects both self-measurement devices (Omron HEM-722C and HEM-735C) satisfied the validation criteria of the BHS and therefore can be recommended for the clinical measurement of blood pressure in elderly patients.

Automation↗

A hardware device for recognition of P and QRS waves.

A new hardware device has been constructed to detect QRS and P complexes for the purpose of automatic arrhythmia interpretation. This apparatus can operate in noisy conditions and provide synchronized pulses representative of P complex, QRS complex, wide QRS, and premature QRS to different output channels. P wave identification is achieved with a high degree of reliability through a specially designed bipolar electrode catheter. The device could minimize demands on central processor time and core storage computer.

Arrhythmias, Cardiac↗

CARDIOMEDIA: a communicable multimedia medical record on Intranet and digital optical memory card.

As part of French health reform, French physicians were computerised by the end of 1998. A specific Intranet network will be used to communicate medical data between the health professionals. The objectives of the CARDIOMEDIA project were to develop and evaluate the feasibility of a coronary multimedia data record stored on an optical card and communicable on Intranet within the hospital. Patients treated by angioplasty at the University Hospital of Rennes participated in the experiment. In general, patients are treated in the University Hospital and are followed up by another health care provider closer to their home. The patient leaves the University Hospital with his card, which is directly available elsewhere for emergency or for consultation. This approach is assumed to reduce the number of examinations and to offer a better patient follow-up. The CARDIOMEDIA card is a specialised record including various data types: text, images, image sequences of coronarography and ECG signals. For this purpose an optical card with its large memory is very convenient. We used the DICOM format for image exchange and management. It is combined with CARDIOMEDIA specific compressing software. For the multimedia record the HTML format and web Intranet method are chosen. This provides an intuitive interface which can combine various data types and helper applications like a DICOM image viewer.

Angioplasty↗

Computer-aided communication device for a child with cerebral palsy.

This paper describes a portable computer-aided communication device designed for a 13-year-old child with athetoid cerebral palsy. The device was intended to provide vocal output, hard-copy, correctable display, word storage capabilities, and utilize currently available technology. The design incorporated the Epson HX-20 computer, the Votrax Type 'N Talk speech synthesizer, and a customized laptray.

Adolescent↗

A critical investigation of the measurement of the force required to dilate the human uterine cervix.

A system for objectively analysing the forces of dilation of the human uterine cervix was devised using a force sensing device linked to a BBC microcomputer. The computer program allowed easy recording, storage and analysis of force/time curves obtained from the passage of tapered dilators through the cervix. A new design of dilator gave a smoother force/time curve. These force/time curves were analysed. Six indices: peak force, end force, area to peak, area to end the ratio of the peak and end forces recorded from the passage of the two largest and two smallest dilators, were compared. Area measurement was subject to artefact and rejected. Peak and end force measurements gave the best separation between parous and nulliparous patients. The peak force was judged to be the better as it was found to be easier to define than end force.

Biophysical Phenomena↗

What, when and how to back up your data.

This article defines and describes the process of backing up data files, which should be undertaken by anyone who routinely uses a computer. The important points to be considered when developing a backup strategy are explained and a résumé given of the backup devices currently available.

Compact Disks↗

Drawing two conclusions on pen computers.

In a modern version of David and Goliath, backers of hand-held pen computers hope to make serious inroads against well-established computer workstations. A start-up company, Practice Technology Inc., wants to build information networks based on pen computing. But it's going up against well-established network vendors that are relying on PC-based systems. Meanwhile, two pen computer manufacturers have stopped producing those devices, citing lack of demand.

Industry↗

What Digital Imaging and Communication in Medicine (DICOM) could look like in common object request broker (CORBA) and extensible markup language (XML).

Common object request broker architecture (CORBA) is a method for invoking distributed objects across a network. There has been some activity in applying this software technology to Digital Imaging and Communications in Medicine (DICOM), but no documented demonstration of how this would actually work. We report a CORBA demonstration that is functionally equivalent and in some ways superior to the DICOM communication protocol. In addition, in and outside of medicine, there is great interest in the use of extensible markup language (XML) to provide interoperation between databases. An example implementation of the DICOM data structure in XML will also be demonstrated. Using Visibroker ORB from Inprise (Scotts Valley, CA), a test bed was developed to simulate the principle DICOM operations: store, query, and retrieve (SQR). SQR is the most common interaction between a modality device application entity (AE) such as a computed tomography (CT) scanner, and a storage component, as well as between a storage component and a workstation. The storage of a CT study by invoking one of several storage objects residing on a network was simulated and demonstrated. In addition, XML database descriptors were used to facilitate the transfer of DICOM header information between independent databases. CORBA is demonstrated to have great potential for the next version of DICOM. It can provide redundant protection against single points of failure. XML appears to be an excellent method of providing interaction between separate databases managing the DICOM information object model, and may therefore eliminate the common use of proprietary client-server databases in commercial implementations of picture archiving and communication systems (PACS).

Computer Communication Networks↗

IS & C system and file protection mechanism.

This paper reports a new extension of IS & C (Image Save And Carry) project. Because IS & C is an off-line system and requires full compatibility so as to enable medical data interchange with ease among hospitals and clinics, specifications that are indispensable for compatibility have been standardized by the IS & C committee. The IS & C system is supposed to be used in medicine, so the file protection mechanism for the security of the recorded files has been also developed. The characteristics of IS & C volume and file structure and the second national project being carried out in National Cancer Center Hospital are briefly explained as well.

Computer Communication Networks↗

An introduction to fractal imaging technology.

In this article the author explains the basic theory and practical applications of the latest advancement in imaging technology called fractal imaging. Fractal imaging is a unique way of compressing and storing images which has unlocked the door to the restrictions imposed by conventional imaging technology as regards storage and transmission of high quality images. The article outlines how this technology has been successfully applied by the creation of the first and only fractal photographic archival and retrieval system in Scotland, in the form of the George Washington Wilson collection comprising 44,000 images and associated text in only 450 megabytes (Mb) of disc space.

Fractals↗