[Mechanical property and adaptability of super-plastic titanium alloy denture base].

The purpose of this study is to investigate the mechanical property and the adaptability of the upper complete denture bases made by superplastic forming of Ti-6A1-4V alloy plates which have various thicknesses. The strength of the denture base made by superplastic forming using the 0.55 mm thickness plate was lower than that of the base made by Co-Cr alloy casting in the standard form when loaded on the hard metal board. But by increasing the thickness by partial or full diffusion bonding of two Ti-6A1-4V alloy plates, the denture base became stronger than the Co-Cr alloy base. With resin occlusion rims, all the denture bases were reinforced. Moreover, when loaded on the mastermodel covered with rubber in the residual ridge and palate area, the difference of the strain between the thin and the thick bases became small. However, the strain of the thin base increased particularly when the base had a contact with the mastermodel on a small area in the palate. The superplastic forming denture bases revealed a high adaptability with the space less than 0.13 mm on the average between the base and the mastermodel. And increasing the thickness of the base prevented the worsening of the adaptability after curing resin for the denture.

Biomechanical Phenomena↗

Evaluation of bond strength of soft relining materials to denture base polymers.

OBJECTIVES: To evaluate the initial bonding properties of recently and previously introduced soft relining materials to denture base polymers with different polymerization techniques and different water content. METHODS: The initial tensile bond strength of 10 soft liners (Mollosil Plus, Dentusil, Ufi gel Soft, GC Reline Soft, Silagum Comfort, Vertex Soft, Astron Soft, Molloplast B, Flexacryl Soft, Triad Resiline) to three denture base polymers (Paladon 65, Palapress Vario, Ivocap Plus) were assessed with a modified method. Paladon 65 specimens immersed in water for 3 months were also used to test the effect of water content of denture base polymer on bond strength results. After testing, a visual examination of the fracture surfaces and a SEM investigation of the interface structure were performed. Tensile strength of each soft liner material was also tested. Data were analyzed statistically by two-way ANOVA (alpha = 0.05). RESULTS: Significant differences were found among tensile bond strength results (P < 0.05). Vinyl poly(organosiloxane) soft liners (Mollosil Plus, Dentusil, Ufi gel Soft, GC Reline Soft, Silagum Comfort) and a plasticized PMMA soft liner (Vertex Soft) gave statistically similar bond strength results for different denture base polymers (P>0.05). For the other materials used (Astron Soft, Molloplast B, Flexacryl Soft, Triad Resiline), different denture base polymers caused significantly different results (P < 0.05). Poly(organosiloxane) based materials gave slightly higher bond strength results with water immersed specimens than with the dry specimens. SIGNIFICANCE: A wide variety of newly formulated soft liners used in this study gave comparable or better bond strength results compared to Molloplast B.

Adhesiveness↗

A review of fiber-reinforced denture base resins.

PURPOSE: One method of reinforcing denture base material is to use fiber composite reinforcement. Different types of fibers, such as glass (GF), carbon/graphite, aramid, and ultrahigh-modulus polyethylene (UHMP) fibers have been tested for this purpose. MATERIALS AND METHODS: This article reviews the studies conducted on the fiber-reinforced denture base resin systems. RESULTS: The literature has reported that the fiber concentration and its adhesion to polymer matrix influences the transverse strength of the fiber composite. The highest transverse strength value (265 MPa) with polymethyl methacrylate (PMMA) was obtained by incorporating 58 wt% GF into the resin. UHMP fibers incorporated into PMMA resin yielded the highest impact strength value (134 kJm-2) of the fiber-PMMA composites. CONCLUSIONS: Despite the improved mechanical properties of fiber-reinforced denture materials, further research is required to show the clinical usefulness of the fiber reinforcement.

Carbon↗

Argyrophilic nucleolar organizer regions (AgNORs) in mucosal epithelium under experimental denture bases in rats.

The purpose of this study was to evaluate changes in the argyrophilic nucleolar organizer region (AgNOR) counts in mucosal epithelium induced by continuous or intermittent compressive pressure exerted through experimental denture bases and to examine the relationships between the AgNOR count, histopathological changes and the intensity of the pressure under denture bases. Continuous or intermittent compressive pressure exerted through the denture bases was applied to the hard palate of the molar region in rats. A morphometric analysis of AgNORs was performed in denture-supporting tissue 3 days and 1, 2, 4, 8, 12 and 20 weeks after the denture insertion. From the results of this study, it was found that non-pressure contact of the denture bases with palatal tissues did not change the AgNOR count. The AgNOR count was decreased by continuous or intermittent compressive pressure, and then recovered to almost the same level as with the non-pressure contact at 20 weeks following a decrease of the pressure. The AgNOR counts in the epithelium under the denture bases were revealed to be related to the histopathological changes in the denture-supporting tissues and the intensity of the pressure under the denture bases.

Acrylic Resins↗

[Effect of ultrasonic scalers, burs and silicone points on the resins for denture bases].

BACKGROUND: Complete dentures in elderly patients often present a large build-up of dental calcolus. In order to avoid this leading to the onset of mycosis or other infections of the oral cavity, all the dental calcolus must be removed during check-ups. METHODS: In order to analyse the consequences of removing the dental calcolus by mechanical means on the resin of the dentures, a polymethylmetacrylate (PMMA) plate was treated with a ultrasonic scaler, with rotating silicone points and with tungsten carbide burrs mounted on a straight hand-grip. The specimens were observed under a light stereomicroscope and their surface was analysed using a surface roughness tester. Observation under the stereomicroscope showed that in all cases the smooth surface of the resin is damaged and modified. RESULTS: The analysis using the surface roughness tester revealed that only very limited quantities of resin are removed whatever the method. Using the lateral edge of the ultrasonic scaler tip and the rotating silicone points mounted on a hand-grip were the techniques that gave the best results, causing the least abrasions. CONCLUSIONS: The results obtained show that after removing the dental calcolus with the instruments tested, the dentures need to be polished in order to prevent the roughness and irregularities caused by the instruments from favouring plaque retention and the consequent reformation of dental calcolus.

Acrylic Resins↗

Flexural strengths of denture base resin repaired with autopolymerizing resin and reinforcements after thermocycle stressing.

PURPOSE: Fracture of an acrylic denture base is a common problem in prosthodontic practice. Although various reinforcement methods have been used, when a fractured denture base is repaired with autopolymerizing resin recurrent fractures frequently occur at the repairing interface or adjacent areas. The purpose of this study was to evaluate the maximum flexural load of denture base resin repaired with autopolymerizing resin and several reinforcement systems after thermocycle stressing. MATERIALS AND METHODS: Rectangular (10 x 70 x 3 mm) flexural specimens were fabricated by repairing a pair of heat-cured denture base resin specimens using autopolymerizing resin and a series of reinforcement materials. The materials included 4 metal wires and a woven glass fiber. Each reinforcement was embedded in the center of the specimens. Flexural specimens repaired without reinforcement were prepared as controls. Specimens were subjected to 50,000 thermocycles (4 approximately 60 degrees C, 1-minute dwell time). A 3-point flexural test was carried out by loading the center of the repaired site at 5 mm/minute crosshead speed with 50 mm span jig supports. The load necessary to cause fracture was recorded for each specimen. All data were statistically analyzed using ANOVA and the Bonferroni/Dunn test (alpha < 0.05). RESULTS: The average load to fracture of specimens repaired with nonreinforced autopolymerizing resin was 68.4 N after 50,000 thermocycles. Specimens reinforced with 1.2 mm diameter stainless steel wire exhibited the highest value (89.8 N). The value for specimens reinforced with 1.2 mm diameter Co-Cr-Ni wire was 86.6 N. These fracture loads were significantly higher than those for specimens without reinforcement (p < 0.05). Low elasticity reinforcement, such as pure titanium wires, woven metal wire, and woven glass fiber were not effective in increasing the load to fracture values of flexural specimens. CONCLUSIONS: Specimens reinforced with 1.2 mm diameter stainless steel wires or Co-Cr-Ni wires resulted in significantly higher loads to fracture as compared to specimens without reinforcement. The use of pure titanium wire, woven metal wire, and woven glass fiber did not improve the fracture loads.

Acrylic Resins↗

Bonding durability of conventional resinous denture teeth and highly crosslinked denture teeth to a pour-type denture base resin.

PURPOSE: The study examined the bond strength between 2 types of resin denture teeth and a pour-type denture base resin after thermocycling. The denture teeth were untreated, prepared with diatorics, or treated with a solvent, dichloromethane. MATERIALS AND METHODS: Conventional denture teeth and crosslinked denture teeth were bonded to a pour-type denture base resin. Compressive load was applied at 45 degrees on the palatal surface of each tooth until fracture. The teeth were either thermocycled or not thermocycled. Porcelain teeth were also tested for comparison. RESULTS: There was no significant difference in bond strength between the conventional resin teeth and the crosslinked denture teeth. Thermocycling significantly decreased the bond strength of the 2 types of resin teeth but had no effect on porcelain teeth. The application of dichloromethane significantly improved the bond strength of the 2 types of resin teeth either before or after thermocycling. CONCLUSION: It is recommended that dichloromethane be applied on the denture teeth ridge-lap area prior to denture base processing.

Analysis of Variance↗

Effect of a resilient layer in a removable partial denture base on stress distribution to the mandible.

The results of two-dimensional finite element analyses of a mandible indicate that a resilient layer within a denture base can act as an effective "shock absorber" and may slow down ridge resorption. Finite element models of similar types can easily be used to further investigate various applications of resilient layers. The magnitudes and distributions of stresses generated in the mandible by force application to two types of a distal extension denture base were determined and compared. The results were obtained by using the finite element method of stress analysis. In the first analysis, a conventional distal extension denture base resting on the mandible was simulated. In the second analysis, the same testing force was applied to a distal extension denture base with a resilient layer between the teeth and the basal seat. The results indicated that the stress distribution was more uniform during occlusal loading through a resilient layer. The vertical displacement of the alveolar ridge under the denture base with a resilient layer was far less than that of the conventional denture base.

Dental Stress Analysis↗

An experimental study on histopathological changes in the tissue covered with denture base without occlusal pressure.

In order to clarify the basic histopathological effect of a denture prosthesis on the denture supporting tissues, a new experimental appliance was developed. The denture base was designed to make contact with palatal mucosa of the experimental animal without any mechanical pressure and transmit no occlusal force to the mucosa. The objectives were: (i) non-pressure contact of denture base with palatal mucosa; and (ii) lack of physiological stimulation for palatal tissue by tongue and/or food. The results of the study revealed that covering the palatal mucosa with a denture base without any mechanical pressure and with the maintenance of a clean palate and denture base, did not cause any inflammatory change and bone resorption in the denture supporting tissues, except for a slight transient proliferative reaction in the epithelial ridges.

Animals↗

The influence of teeth on denture base processing accuracy.

The Michigan Computer Graphics Coordinate Measuring System was used to determine the influence of denture teeth on the accuracy of processed denture bases. Three different processing methods--compression molding, injection pressing, and vacuum-assisted resin pouring--were used. The presence of denture teeth was determined to affect the accuracy of the processed denture bases of all three techniques. For denture bases without teeth, the compression-molding technique demonstrated significant differences in accuracy; however, no significant differences were found in the injection-pressed or resin-poured denture bases.

Computer Graphics↗

The cytotoxic effects of denture base resin sealants.

Previous studies have shown that light-polymerized denture base resins have a cytotoxic effect on oral epithelial cells. The purpose of this in vitro study was to examine the effects of two denture base resin sealants when used on three light-polymerized denture base resins. Sample disks were examined for their effect on protein synthesis. Results indicate that one sealant protected the cells against toxic effects of the materials (P < .05), while one sealant enhanced toxicity up to 88% above that attributed to the resin alone.

Acrylic Resins↗

Dimensional changes of processed denture bases after relining with three resins.

This study compared the dimensional change of simulated processed denture bases after relining with three resins. Thirty simulated denture bases 1.5 to 2 mm thick were processed from Lucitone 199 resin following the manufacturer's instructions using the long-cure method. Ten bases were relined with Lucitone 199 (long-cure), 10 were relined with Triad resin, and 10 were relined with Accelar 20 resin. The relined bases were processed on a metal die using a reline jig, and three measurements (from distobuccal flange to distobuccal flange) were made with a traveling microscope immediately before and after relining. Each relined simulated denture base showed a significant dimensional shrinkage after processing. The mean dimensional change values of the Triad resin relined bases were significantly greater than those of the other two resin relined bases. All of the dimensional change values, however, would probably be insignificant in a clinical situation.

Acrylic Resins↗

Relationship between plasticizer content and tensile bond strength of soft denture liners to a denture base resin.

The purpose of this study was to determine the influence of plasticizer content on the tensile bond strength of heat-cured acrylic soft denture liners to a denture base resin. Differences among materials were significant, except for 100 wt% Dibutyl Sebacate (DBS) and 80 wt% DBS of tensile bond strength. The bond strength of all materials to the denture base increased with an increase in thermal cycles significantly except for 40 wt% DBS. The tensile bond strength of soft denture liners to the denture base resin significantly decreased with an increase of plasticizer contents. Differences were found among the difference plasticizer contents in failure types between the denture base resin and soft denture liners. The results suggest that the tensile bond strengths of heat-cured acrylic soft denture liners to the denture base resin were lower with an increase in plasticizer content.

Acrylic Resins↗

[Effect of acrylic resin post-pressing time on dimensional change of total denture base].

The dimensional alterations of denture bases were verified in function of the acrylic resin post-pressing time. Twenty stone cast/wax base sets were confected for routine flasking procedure. Thermosetting acrylic resin (Clássico) was prepared according to the instructions of the manufacturer. After final pressing, the acrylic resin was submitted to polymerization in water at 74 degrees C during 9 hours, following the immediate, 6-, 12-, and 24-hour post-pressing times. The resin bases were fixed on the casts with instantaneous adhesive and the sets were laterally sectioned in the regions corresponding to the distal aspect of canines (A), mesial aspect of first molars (B), and posterior palatal zone (C). The gap between the stone cast and the resin base was measured with a comparative microscope at five referential positions for each kind of sectioning. Data submitted to ANOVA and Tukey's test showed that there was no statistically significant difference between the immediate and the 6-hour post-pressing times as well as between the 12- and the 24-hour post-pressing times. However, there was statistically significant difference between the immediate/6-hour groups and the 12-/24-hour groups.

Acrylic Resins↗

Fabrication of a duplicate denture using visible light-polymerized resin as an interim denture base.

This article describes a technique for producing a duplicate denture using a visible light-polymerized (VLP) denture base for support prior to processing. A 2-part mold of the original denture was made, and then a sheet of VLP resin was reduced to a thickness of 0.5 mm and adapted to the fitting surface of the mold to create a denture base. The base was polymerized and the remaining features, such as the teeth and polished surfaces of the denture, were reproduced in wax. This technique may be helpful when performing subsequent clinical and laboratory procedures.

Acrylic Resins↗

Degradation of repaired denture base materials in simulated oral fluid.

This in vitro study evaluates the degradation of repaired denture bases upon immersion in a simulated oral fluid. Denture base materials (Luciton 199), after being repaired by Repair Material and Triad, using three different joint surface designs (butt, round and 45 degrees bevel), were immersed onto 99.5 vol.% ethanol/water solution (with similar solubility parameter) for various amounts of time (0-72 h). The flexural loads of the six combination of groups were measured by the three-point bending tests using a universal testing machine. Acoustic emission (AE) during sample fracturing were processed using the MISTRA 2001 system. The fracture pattern and surface details of the interface were examined with a scanning electronic microscope (SEM). Data were analysed using three-way ANOVA and Tukey LSD tests. SEM micrographs of the fracture interface were used to differentiate the fracture mode. The flexural loads (2.72 +/- 0.51 Kgf) of the round joint specimens were significantly higher (P< 0.05) than those (butt: 1.66 +/- 0.38 Kgf, 45 degrees bevel: 1.93 +/- 0.41 Kgf) of the other two designs. This corresponds to the microscopic examination in which more cohesive failure mode was found for the round joint group after storage. The flexural loads (2.54 +/- 0.39 Kgf) of the specimens repaired with Triad were significantly higher (P < 0.05) than those (1.59 +/- 0.40 Kgf) of specimens repaired with Repair Material. Significant progressive reduction of the flexural load and/or AE signals of the specimens was noted in proportion to the length of time of the immersion in the simulated oral fluid. Mechanical strength of a denture base repaired with a round joint design and light-cured material is significantly higher after immersion in simulated oral fluid.

Acoustics↗

Water sorption by maxillary acrylic resin denture base and consequent changes in vertical dimension.

Many kinds of materials have been tried in the Laboratory and to some extent clinically prior to introduction of acrylic resin. With the introduction of acrylic resin as denture base material, continuous attempts have been made to evaluate its physical properties. To observe the changes in vertical measurements of acrylic resin dentures due to water sorption and to assess variations of vertical movements of individual teeth within dentures due to water sorption; present study was carried out on 25 maxillary acrylic dentures. From results, the maximum water sorption appears to take place within 24 hours and after 28 day of water sorption; there is no change in vertical dimension if the denture is placed for further more time. With the introduction of acrylic resin as denture base material continued attempts have been made to evaluate physical properties so as to determine its suitability as an ideal nonmetalic denture base materials. Several investigations have been carried out on physical properties of this material such as compressive strength, tensile strength, solubility and colour stability. These have proved their superiority over other nonmetalic denture base materials used so far. Also several studies have been carried out to assess dimensional changes that occur in acrylic resin during processing, but very few studies have been carried out about the water sorption changes in the acrylic resin and still few about the vertical dimensional changes in acrylic resin due to water sorption. While fabricating the denture base from the acrylic resin, it comes in contact with water during polishing as well as cleaning, consequently during the use of denture it is constantly wetted by oral fluids. It is the hypothesis that water sorption by denture base acrylic may effect the retention and stability of the denture. It has been shown that water molecules act according to the laws of diffusion. The diffusion presumably occurs between the macromolecules which are forced slightly apart. This separation renders the molecules mobile and the inherent stresses created during heat curing of the acrylic resin can be relieved with consequent intermolecular relaxation and possible changes in the shape of the denture. Exposure time also plays a significant role in water sorption. The present investigation was therefore, carried out by keeping the following objectives: (1) The primary objective was to observe the changes in vertical measurements of acrylic resin dentures due to water sorption. (2) To assess the variations of vertical movement of individual teeth within the dentures due to water sorption.

Absorption↗

Relationships between denture base resin cytotoxicity and cell lipid metabolism.

Substances that elute from denture base resins may inhibit cell growth and disrupt various metabolic processes. This study investigated the effects on cell lipid metabolism of eluates from several denture base resins. Cultured oral epithelial cells were exposed in vitro to eluates of discs made from several denture base resins. Lipid metabolism of the cells was measured using isotopic labeling with 14C-acetate. Results demonstrated that the metabolism of several lipid classes found mainly in the cell membrane was altered by the resin eluates. Eluate from one resin caused the appearance of two previously unrecognized classes of lipids. The alterations of the cell lipids and the presence of the previously unrecognized lipids may be the basis for some clinically evident cytotoxic and allergic reactions.