PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Electrodes, Implanted”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

[A modified method for the determination of locations of chronically implanted electrodes in rabbit brains (author's transl)].

A fast and simple method is described for the localisation of tips of chronically implanted electrodes in the brain of rabbits which may be obtained--under standard conditions--by an intra-aortal injection of a 2% potassium-hexacyanoferrate-III solution. This method also facilitates histological preparations with a thickness of 5 mu only and thus permits a thorough morpho-pathological examination not only in the area of the electrode tips but in adjacent zones as well. The use of a buffered formalin solution also permits certain histochemical examinations to be made, for instance the determination of nucleic acids.

Animals↗

[An inordinate elevation in pacing threshold after myocardial electrode implantation].

An inordinate elevation in pacing threshold beyond a maximal output of the pulse generator was observed in 4 patients during the acute interval following permanent pacemaker implantation using a myocardial electrode. Pacemaker implantation was performed in these patients (9 months, 11 months, 5 years and 32 years of age) for the treatment of brady-arrhythmias (complete A-V block or atrial fibrillation) developed following open heart surgery. In two infants, hypopotassemia caused transient pacing failure due to an increase in threshold over 5 volt. In other two patients, threshold increased to levels more than 10 volt within 36 and 12 days probably due to unsuitable pacing site, and then the pulse generators were removed. It is important to measure threshold periodically after permanent pacemaker implantation and to consider the possibility of an inordinate elevation in threshold.

Adult↗

Cuff electrode implantation around the sciatic nerve is associated with an upregulation of TNF-alpha and TGF-beta 1.

Epineurial fibrosis, fiber loss, limited reproducibility of recordings and variability of stimulation conditions have been documented after extraneural cuff electrode implantation. These morphological and electrophysiological modifications could be due to the local release of cytokines. We report the expression of two cytokines, tumor necrosis factor-alpha (TNF-alpha) and transforming growth factor-beta1 (TGF-beta1) in the rat sciatic nerve after 'cuff' implantation for 18 h, 7 days and 1 month. Immunohistochemical and Western blot analyses showed a transient upregulation of TNF-alpha, during the first week, and a prolonged increase of TGF-beta1, over the 1-month period duration of this study. Considering the known pro-inflammatory roles of TNF-alpha and the pro-fibrotic action of TGF-beta, our results strongly suggest that these cytokines may contribute to nerve alterations occurring within the acute and sub-acute phases after cuff electrode implantation.

Animals↗

[Use of an implanted electrode for rehabilitation after tenolysis of the flexor tendons].

The electric stimulation is widely used in flexor tenolysis rehabilitation by the authors. Since 1983 implantable electrodes were used during the operative procedure. Actually they gave better access to the deep muscles (Flexor Profundus of the index), better specificity, less dysesthesia of the skin. Further more they allowed to tests the quality of the tenolysis without wrist incision. This procedure gave 76% of good or very good results over 25 finders in 20 patients. The results were especially good for the index finger which is usually unable to be stimulated by the surface electrodes and for the fingers badly damaged. In this type of situation prognostic was getting better (70% of good and very good results).

Adolescent↗

[A time-saving method for histo-enzymatic studies of brain tissues of animals with chronically implanted electrodes by means of a hard-section microtome (author's transl)].

A time-saving method is described for the localisation of chronically implanted electrodes in the brain of test animals by means of a "Kryostat" hard section microtome which allows both histo-topographic and histo-enzymatic investigations. This is made possible by the incorporation of a three-dimensional microtome holder.

Animals↗

Anti-TNF-alpha reduces the inflammatory reaction associated with cuff electrode implantation around the sciatic nerve.

Extraneural cuff electrodes have been extensively used to investigate the nervous system. Their implantation is, however, associated with epineurial fibrosis, fiber loss, limited reproducibility of recordings and variability in stimulating conditions. It has recently been shown that TNF-alpha is involved in nerve alterations after electrode implantation. This study investigated whether a peri-operative anti-TNF-alpha treatment could modify the inflammation and fibrosis associated with cuff electrode implantation. Morphometrical and immunohistochemical methods were used to show that a single systemic injection of TNF-alpha neutralizing antibodies is sufficient to reduce the early inflammatory events, but not the long lasting fibrotic reaction.

Animals↗

[Intracochlear placement of cochlear implant electrodes in soft surgery technique].

It is commonly accepted that the intracochlear placement of the cochlear implant electrode is potentially damaging to the hearing rests which may exist. Consequently, cochlear implants have been recommended for totally deaf ears only. The question has been raised whether or not it is possible to preserve residual hearing during intracochlear implantation through extremely careful surgical techniques. Experience has shown, that the cochleotomy of the scala tympani anterior to the round window niche, careful preservation of the fibrine endost layer and the use of Healon are amongst the surgical procedures described which may assist in retaining the rest function of the inner ear. These observations which are discussed in detail suggest that the experienced surgeon can effect preservation of residual hearing for patients who cannot derive significant benefits from conventional acoustic amplifiers.

Adult↗

[Changes in the membrane structure of the brain microsomes in cats with electrodes implanted in the inner ear].

Using spin-labels it was shown that electrode implantation into the cats scala media resulted in structure reconstruction of microsome membranes of auditory zones in cats brain. Membrane fluidity increased but there was no change of surface potential. The changes of microviscosity were found during the first month after the implantation. Five months later the order parameter returned to the mean valve for cats in control group without electrodes.

Animals↗

Representation of acoustic signals in the human cochlea in presence of a cochlear implant electrode.

BACKGROUND: In subjects with remaining low frequency hearing, combined electric-acoustic stimulation (EAS) of the auditory system is a new therapeutic perspective. Intracochlear introduction of a cochlear implant electrode, however, may alter the biomechanical properties of the inner ear and thus affect perception of acoustic stimuli. STUDY DESIGN: Based on histological observations of morphologic changes after cochlear implantation in cadaveric and post mortem studies the effects of basilar membrane (BM) stiffening in the ascending basal and middle turns of the cochlea due to close contact of the BM with the electrode were simulated in a 3D-computational finite element model of the inner ear. To verify our simulated results, pre- and postoperative pure-tone audiograms of 13 subjects with substantial residual hearing, who underwent cochlear implantation, were evaluated. RESULTS: In the scenario of partial BM-fixation, acoustic energy of middle (2 kHz) and high (6 kHz) frequency was focused basally and apically to the fixed section, increasing BM displacement amplitudes up to 6 dB at a stimulation level of 94 dB (SPL). Lower frequencies were not affected by fixation in the basal and middle turn of the cochlea. In implanted subjects, a small but significant decrease of thresholds was observed at 1.5 kHz, a place in tonotopy adjacent to the tip region of the implanted electrode. CONCLUSION: Our model suggests that stiffening of the basilar membrane adjacent to an implanted electrode into the basal and middle cochlear turn did not affect BM movement in the low frequency area. Focussing of acoustic energy may increase perception in regions adjacent to the fixed section. Observations in implanted subjects were concordant with our model predictions. High frequencies, however, should not be amplified in patients using EAS to avoid disturbances in discrimination due to tonotopically incorrect frequency representation.

Acoustic Stimulation↗

Accuracy of MR-guided stereotactic electrode implantation. 1. Preimplantation correlation with the Talairach system.

The accuracy of stereotactic electrode implantation using MR guidance and a computerized imaging system was compared to the conventional Talairach system, using ventriculography and a stereotactic atlas. A combined methodology of two stereotactic approaches was used, with a modified Leksell and a Todd-Wells frame. The coordinates of temporo-limbic structures and the length of the AC-PC line were measured prior to implantation in 10 epileptic patients undergoing the combined procedure. Relative differences in single and three-dimensional values were obtained for 68 targets within the temporal lobe. Lengths of AC-PC lines were measured in 9 patients. Statistical differences were found for all temporal coordinates, but the AC-PC line did not differ significantly.

Brain Mapping↗

Histochemistry of trauma after electrode implantation and stimulation in the hippocampus.

Electrodes were implanted into the rat hippocampus in both hemispheres for increasing periods of up to 60 days, and the effects of trauma and electrical stimulation of enzymes controlling cell metabolism in the region of implantation were examined and assessed in relation to studies on humans. In the unstimulated hippocampus as a control, enzyme changes were mainly confined to a narrow area of tissue damage surrounding the electrode. The enzyme changes in response to trauma varied widely; some enzymes controlling tissue respiration showed early and rapid changes, increasing in hyperactive, swollen glial cells and vascular endothelium and decreasing in nerve cells and neuropile. Acid phosphatase activity also increased rapidly in glial cells; other phosphate-releasing enzymes increased more gradually with time. A turning point in these chages was apparent between 25 and 40 days, followed by a reversion to more normal levels at 60 days. Electrical stimulation of the hippocampus in the contralateral hemisphere produced no detectable enzyme changes from those of the unstimulated hippocampus.

Acetylcholinesterase↗

Determination of the position of nucleus cochlear implant electrodes in the inner ear.

Accurate determination of intracochlear electrode position in patients with cochlear implants could provide a basis for detecting migration of the implant and could aid in the selection of stimulation parameters for sound processor programming. New computer algorithms for submillimeter resolution and 3-D reconstruction from spiral computed tomographic (CT) scans now make it possible to accurately determine the position of implanted electrodes within the cochlear canal. The accuracy of these algorithms was tested using an electrode array placed in a phantom model. Measurements of electrode length and interelectrode distance from spiral CT scan reconstructions were in close agreement with those from stereo microscopy. Although apparent electrode width was increased on CT scans due to partial volume averaging, a correction factor was developed for measurements from conventional radiographs and an expanded CT absorption value scale added to detect the presence of platinum electrodes and wires. The length of the cochlear canal was calculated from preoperative spiral CT scans for one patient, and the length of insertion of the electrode array was calculated from her postoperative spiral CT scans. The cross-sectional position of electrodes in relation to the outer bony wall and modiolus was measured and plotted as a function of distance with the electrode width correction applied.

Adult↗

Electrical stimulation of pelvic floor musculature by percutaneous implantable electrodes: a case report.

A forty-year-old man with reflex urinary incontinence due to spinal cord injury was treated with electrical stimulation of the pelvic floor musculature. In this case we employed percutaneous implantable electrodes and an external pulse regulator. After 4 weeks of stimulation incontinence was improved and urodynamically maximum cystometric capacity increased from 220 ml to 350 ml. Our method is easy and not invasive. This technique can be an alternative for the electrical stimulation for urinary incontinence.

Adult↗

Dual electrode stimulation using the nucleus CI24RE cochlear implant: electrode impedance and pitch ranking studies.

OBJECTIVE: The first aim of the study was to determine the reduction in electrode impedances using dual electrode stimulation compared with single electrode stimulation in the new Nucleus CI24RE receiver-stimulator. The CI24RE is connected to the Nucleus 22-electrode intracochlear array. Dual electrode stimulation is produced by electrically coupling two adjacent single electrodes. The second aim was to determine whether dual electrode stimulation produced pitch percepts that were intermediate to the pitch of the two adjacent single electrodes. DESIGN: Eight postlingually hearing-impaired adults with severe to profound loss, implanted with the CI24RE, participated in the study. Electrode impedances were measured by using the standard telemetry function of the system. A pitch ranking task was used to measure pitch for dual and single electrodes. Seven sets of three electrodes along the electrode array were tested. Each set of electrodes consisted of a dual electrode and the two adjacent single electrodes. Pitch ranking was measured using a two-alternative forced choice procedure, with the three electrodes in each set paired with each other as AB and BA pairs. The subject indicated which of the two stimuli had the higher pitch. Random variation in current level was used to remove any loudness cues. RESULTS: The average electrode impedance was 38.6% lower for dual electrodes compared with single electrodes. Three subjects were able to successfully rank the three electrodes in each set in the expected tonotopic order for all seven sets of electrodes along the array. Three other subjects were able to rank sets of electrodes in the tonotopic order for most of the tested positions on the array. The remaining two subjects gave more variable pitch ranking across positions along the array, although successful tonotopic ranking was demonstrated for several sets of electrodes. CONCLUSIONS: Dual electrode stimulation with the CI24RE receiver-stimulator produced systematically lower electrode impedances and was capable of producing pitch percepts that were intermediate to those produced by the corresponding adjacent single electrodes. This makes available up to 43 channels of stimulation from 22 single electrodes.

Adult↗

The effects of electrical stimulation on denervated muscle using implantable electrodes.

This experimental study investigated the effects of continuous electrical stimulation on denervated muscle. The canine peroneal nerve was severed and repaired microsurgically, and the denervated extensor muscle group of the leg was stimulated continuously with an implantable electrode and pulse generator. EMG study, muscle force measurement, muscle weight measurement, histology, and histochemistry were performed to study the effect at eight weeks after the operation. Continuous electrical stimulation (pulse frequency 130 pps, burst rate approximately 1 train/min) was effective in decreasing muscle atrophy and in improving muscle force. These findings may have broader clinical applications.

Animals↗

Towards micro electrode implants: in vitro guidance of rat spinal cord neurites through polyimide sieves by Schwann cells.

Our goal is to develop biohybrid neural microprobe implants with sieve electrodes for external stimulation of co-implanted neurons whose axons penetrate through the holes of electrodes and innervate host targets such as denervated muscle fibers. For evaluation of implants, potential scar formation was imitated in fibroblast-spinal cord co-cultures. In vitro neurite extension through flexible 10-microm thick polyimide sieves was inhibited by co-cultured fibroblasts. In contrast, the neurite penetration of sieves could be greatly stimulated by oriented exposure to Schwann cells. To our knowledge this is the first direct proof that Schwann cells display a guidance effect on spinal cord neurons in vitro. The results pave the way for novel biohybrid neuro-implants and provide means to circumvent the obstacle of inhibitory scar formation.

Animals↗

Hyperthermia with implanted electrodes: in vitro and in vivo correlations.

Hyperthermia as a treatment for cancer has elicited much recent interest. However, major difficulties persist both in the technology for heating deep-seated tumors, and in thermal dosimetry. We have investigated a heating technique for deep-seated neoplasms that employs an internal implanted electrode and an external electrode to apply radiofrequency current to a tumor mass. The internal electrode consists of an array of stainless steel needles or wires which define a Faraday cage within the tumor, while the external electrode consists of a variety of electrical conductors at the skin surface. Phantom measurements have closely reproduced calculated temperature distributions. The temperature profiles within the volume enclosed by the internal electrode show relatively homogenous heating. Temperature measurements in a rat tumor model have demonstrated that significant heating within such an internal electrode array is easily obtained. The heating may extend some centimeters outside the electrode. Using a dog model we have shown that with such a treatment technique the temperature profiles obtained are reproducible both spatially and temporally. A case report of a clinical application is presented. A 5 cm bronchogenic carcinoma was easily heated without significant heating of the surrounding normal lung, and without apparent toxicity. Such a technique may be applicable to a variety of operable but unresectable neoplasms. The reproducibility and relative homogeneity of heating suggest possible usefulness in combined modality trials.

Adenocarcinoma↗

Alleviation of atypical trigeminal pain by stimulation of the Gasserian ganglion via an implanted electrode.

Facial pain associated with disturbances of sensitivity as a sign of injury of the trigeminal nerve is difficult to treat. Drug therapy as well as blocking procedures are generally ineffective. Transcutaneous nerve stimulation offers a new possibility for pain alleviation but is inconvenient for the patient. A method for stimulation of the gasserian ganglion via an implanted electrode has been developed. Five cases are reported on and they all experienced excellent or good pain relief. Follow-up is 6-21 months.

Adult↗