Performance of the Baxter Flo-Gard 6201 volumetric infusion pump for monoplace chamber applications.

For non-hyperbaric purposes, the Baxter Flo-Gard 6201 volumetric pump is capable of infusing multiple types of fluids at rates of 1-1,999 ml x h(-1). We designed a study to determine flow accuracy of this pump at variable rates, fluid viscosities, and volumes over a range of chamber pressures. For hyperbaric use, the pump pressure sensor was adjusted. Sodium chloride solution 0.9% (NS), enteral formula, and packed red blood cells (PRBC) were infused at varying rates from 86.1 to 304 kPa (0.85 to 3.0 atm abs). For NS, measured compared to set flow rates ranged from 12.5% to -7.5% at settings of 1 and 5 ml x h(-1) from 86.1 to 304 kPa (0.85 to 3.0 atm abs) pressures, respectively. For NS infusions at a set rate of 100 ml x h(-1), the measured flow was identical to the set rate at all pressures. At flow settings of 1,999 ml x h(-1), the measured flow varied from the set flow by +/-4.9% Enteral infusion at 100 ml x h(-1) showed approximately a 3% increase in the measured vs. set flow rate. PRBC measured flow rates ranged from -0.4 to 6% of the set rate. During chamber compression and decompression, with set flow rates from 1 to 10 ml x h(-1), the measured flow was considerably less than expected during compression and more than expected during decompression. In conclusion, the Baxter Flo-Gard 6201 infusion pump demonstrated acceptable performance for infusing saline, enteral formula, and PRBC at low and high infusion rates into the pressurized monoplace hyperbaric chamber up to 304 kPa (3 atm abs), with the exception of low rates during compression and decompression.

Atmosphere Exposure Chambers↗

[Continuous intrathecal administration of nicardipine using a portable infusion pump system for management of vasospasm after subarachnoid hemorrhage].

We studied the feasibility of intrathecal nicardipine administration using a portable infusion pump system in five cases (two males and three females) of subarachnoid hemorrhage (SAH). All of the five cases manifested severe SAH of Hunt & Kosnic grade 3 or 4, and Fisher CT group 3. Aneurysmal sites of five cases were as follows: three internal carotid-posterior communicating artery (IC-PC) aneurysms and two anterior communicating artery (Acom) aneurysms. The container of the infusion pump system was filled with 105 ml of nicardipine-saline solution (2:1), and this system was connected to the cisternal tube. The solution was continuously injected at a daily dose of 12 ml (8 mg of nicardipine). This therapy was continued for 14 days, and new nicardipine solution was supplied only once at 8 days after the operation during this therapy. No postural restraint of patients was necessary, even during physical movement for rehabilitation. Postoperative angiography was performed in three of five cases at one week after the operation. No angiographic vasospasm was observed in any of the three cases. Symptomatic vasospasm was observed in one case of right IC-PC aneurysm as a transient total aphasia and right hemiplegia, which recovered within several hours due to induced hypervolemia and hypertension therapy. Mild meningitis at 14 days after the operation complicated this treatment in one case, but it improved in a few days after the cisternal tube was removed. It was speculated that meningitis was caused by cerebrospinal fluid leakage from the scalp exit site of the cisternal tube. All of the five cases had obtained good recovery at three months after the operation. These results show that, although this method involves a risk of infection, it has the advantage of easiness and convenience over conventional methods. Though further improvement of this method is required, this preliminary stage is potentially useful for delivering not only nicardipine, but also for other drugs which may be used in intrathecal administration therapy.

Aged↗

Mortality among diabetic patients using continuous subcutaneous insulin-infusion pumps.

Because of concern about deaths among diabetic patients using continuous subcutaneous insulin-infusion pumps, we conducted an investigation to determine whether the number of such deaths was excessive. By October 1982 we had identified 35 deaths among the estimated 3500 diabetic patients using pumps in the United States. The observed number of deaths was not greater than the expected number calculated from age-specific death rates for conventionally treated patients with Type I diabetes. The causes of death were not unusual, with two exceptions. One death was associated with malfunction of the device, and the other was attributed to acute bacterial endocarditis that arose from an abscess at the catheter-insertion site. Patients who died had high rates of autonomic neuropathy (66 per cent) and renal disease (39 per cent with serum creatinine levels above 5 mg per deciliter). We conclude that the use of continuous subcutaneous insulin-infusion pumps is not associated with excess mortality. However, certain types of patients may be at greater risk for death, and physicians should take great care in selecting patients for pump therapy.

Adolescent↗

Accuracy of a peristaltic finger-type infusion pump during hyperbaric oxygen therapy.

PURPOSE: To evaluate the accuracy of a peristaltic finger-type pump during hyperbaric oxygen therapy (HBO). METHODS: Using two examples of one type of infusion pump, we evaluated its accuracy at 2 ATA (atmospheres absolute) by measuring the actual volumes pumped at given time points (flow rate) and comparing these data with the corresponding data obtained at 1 ATA. RESULTS: There was no significant difference in flow rates between 2 and 1 ATA. In terms of accuracy, the present pump was superior to the syringe pump tested in our previous study. Under our conditions, the ambient pressure might have acted equally on the inlet and outlet sides of the infusion line, which may explain the lack of effect of 2 ATA on flow rates. This is not the case with a syringe pump, and the difference in flow-generating mechanisms may help explain the different results obtained in our two studies. CONCLUSION: The present type of pump could be used during HBO (at 2 ATA) with the same accuracy as at 1 ATA. Whether the ambient pressure can affect pump input and output (peristaltic-pump infusion line) or only pump output (syringe type) may determine whether accuracy suffers under HBO conditions.

Journal Article↗

Portable insulin infusion pumps as an alternative means of insulin delivery in type I diabetes. Report on 11 patients.

In many cases of type I diabetes it is extremely difficult to maintain adequate long-term diabetic control. Over the last decade a better understanding has been gained of the relationship between hyperglycaemia and the onset of diabetic microvascular disease. Because of this new techniques are being developed to improve diabetic control; one of these is the use of portable 'open loop' insulin infusion pumps. The results achieved in the first 11 patients to use the Auto-Syringe AS-6C insulin infusion pump on an outpatient basis for longer than 4 months are described. A highly significant improvement in fasting blood glucose levels, 2-hour postprandial blood glucose levels, mean blood glucose levels, glycosylated haemoglobin levels and mean glycaemic excursions was noted in all patients. No cutaneous complications developed despite the use of indwelling subcutaneous needles for up to 4 days at a time. Patient acceptability was excellent and none of the patients had any problems in adapting to 24-hour pump use. The importance of correct patient selection and continuous home blood glucose monitoring is stressed. Insulin infusion pumps can provide an alternative and highly efficacious means of maintaining excellent diabetic control in a select group of type 1 diabetics. However, it is essential that the physician be trained in the use of these pumps and that adequate back-up services are available.

Adult↗

Insulin infusion pumps in the treatment of diabetes.

The long-term complications of diabetes mellitus remain a serious public health problem in the Western nations. Much current research focuses on methods of insulin treatment designed to provide near-normal glycemic control throughout the day with the intention of preventing or delaying the onset of the angiopathic consequences of preventing or delaying the onset of the angiopathic consequences of diabetes. Recent work has shown that open-loop insulin infusions (that is, insulin administered by an infusion pump without feedback control) can result in near-normal blood glucose levels in juvenile-onset or Type I diabetics. The extracorporeal infusion pumps used in such studies have their won physical and psychological drawbacks, however. More recent studies have attempted similar degrees of control using totally implantable insulin infusion pumps; several such studies are being carried out in patients with adult-onset or Type II diabetes, the predominant type of diabetes afflicting the elderly.

Aged↗

[The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems] .

Application of highly concentrated short-acting vasoactive drugs in the critically ill patient requires precisely working syringe pump systems for continuous intravenous drug delivery. We performed a bench study to investigate the consequences of small amounts of air entrapped within a 50-ml infusion syringe. In particular we studied the effect of entrapped air on drug delivery after moderate vertical displacement of the pump by 50 cm (e.g. in preparation for transport) and the effect on the time required to trigger the pressure alarm after occlusion of the infusion line. At a flow rate of 1 ml/h, lowering the syringe pump prolonged the zero-drug delivery time from (mean +/- SD) 4.1 +/- 0.8 min (without air) to 6.2 +/- 0.9 (with 1 ml air) and to 13.1 +/- 0.9 min (with 2 ml of air, p < 0.001 for all comparisons). Entrapping of 2 ml of air within the syringe resulted in a 2.6-fold prolongation of the occlusion alarm time after accidental occlusion of the infusion line and a 3-fold increase of the resulting infusion bolus after occlusion. Enclosed air within infusion syringes considerably affects the syringe compliance. It increases the susceptibility of constant drug delivery to vertical displacement of syringe pumps and impairs the occlusion alarm function. Therefore, any air in syringe of infusion pump systems should be carefully removed. To avoid infusion boluses of short-acting vasoactive drugs after accidental occlusions, the occluded infusion line should be released to ambient pressure first.

Air↗

Computer control of an Imed 929 infusion pump.

There is a growing interest in the potential benefits to be obtained from closed-loop control of drug infusion [1-5]. The most widely available infusion pump which is specifically designed for control by computer is the 929 volumetric infusion pump produced by Imed. The increasing availability of microcomputers suggests that they will be used more frequently to control such pumps. However, difficulties can arise when the attempt is made to establish communication between the computer and the pump [6] and a method employed for this purpose is described in this article. The aim was to provide a simple method of conducting the required communication between the computer and the pump using a high-level language. The commands specified in the high-level language are passed to a machine-code subroutine which organizes transmission to and receives data from the pump.

Computers↗

Effect of continuous subcutaneous administration of a small dose of granulocyte colony stimulating factor (G-CSF) by the use of a portable infusion pump in patients with non-Hodgkin's lymphoma receiving chemotherapy.

The effects of continuous subcutaneous infusion (CSI) of human granulocyte-colony stimulating factor (G-CSF) on the absolute neutrophil count (ANC) and serum G-CSF level were examined in 11 patients with non-Hodgkin's lymphoma (NHL) during cytotoxic chemotherapy. Recombinant G-CSF (rG-CSF) was subcutaneously infused using a portable infusion pump at a constant flow rate of 1 microgram/20 microliters/h for 14 days starting 2 days after the end of the second course of chemotherapy. The ANC was lowered after the chemotherapy without rG-CSF infusion whereas the duration of neutropenia and the nadir level of the ANC after the chemotherapy were ameliorated by the combined administration of rG-CSF (mean +/- S.E., 0.6 +/- 0.5 days vs. 4.7 +/- 1.9 days, P < 0.05; 455 +/- 135/microliter vs. 1906 +/- 598/microliter, P < 0.05). Serum G-CSF levels increased after the start of rG-CSF infusion, reaching a mean peak value of 418.5 +/- 128.5 pg/ml at the 8th day, and then returned to the basal level (35.6 +/- 13.5 pg/ml) immediately after the end of continuous infusion of rG-CSF. Although a slight increase in serum G-CSF was obtained in the patients after the chemotherapy without rG-CSF administration, the mean serum level was much lower than that in the patients after the chemotherapy with rG-CSF administration (88.2 +/- 24.8 pg/ml vs. 199.6 +/- 20.6 pg/ml, P < 0.01). No notable side effects of the CSI of rG-CSF were noted.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

An evaluation of intravenous infusion pumps and controllers.

The accuracy, safety, reliability and cost of use of 35 intravenous infusion pumps and 3 flow controllers were assessed. When infusing saline 11 out of 17 syringe pumps, 3 out of 5 peristaltic pumps, 1 out of 2 roller pumps and all 14 cassette pumps tested were accurate to within 5% over their full ranges of operation. There was no significant change in the performance of any of the pumps tested when saline was infused through a standard resistance, except in the cases of the 3 flow controllers which were unable to infuse at all against the resistance. When 50% dextrose was infused, delivery by two peristaltic pumps was reduced by 23 and 38%. No pump cut out or alarmed at pressures of up to 200 mmHg and 21 pumps continued to infuse against pressures of 750 mmHg or greater. Surges of up to 0.5 ml occurred after release of an outlet obstruction. One device was fitted with a variable high pressure alarm. This device could also measure pressure in the infused vessel and was found to be accurate for measurements of central venous pressure. The cost of consumables for a single use for syringe pumps ranges from A$2 to $5, for peristaltic and roller pumps from A$1 to $10, and for cassette pumps from A$7 to $12, with an additional A$2 for a burette. Accurate delivery of intravenous fluids and drugs is available but is expensive and requires the operator to be specially trained. No simple, cheap, accurate device is yet available.

Evaluation Studies as Topic↗

Measuring the predictive performance of computer-controlled infusion pumps.

Current measures of the performance of computer-controlled infusion pumps (CCIPs) are poorly defined, of little use to the clinician using the CCIP, and pharmacostatistically incorrect. We propose four measures be used to quantitate the performance of CCIPs: median absolute performance error (MDAPE), median performance error (MDPE), divergence, and wobble. These measures offer several significant advantages over previous measures. First, their definitions are based on the performance error as a fraction of the predicted (rather than measured) drug concentration, making the measures much more useful to the clinician. Second, the measures are defined in a way that addresses the pharmacostatistical issue of appropriate estimation of population parameters. Finally, the measure of inaccuracy, MDAPE, is defined in a way that is consistent with iteratively reweighted least squares nonlinear regression, a commonly used method of estimating pharmacokinetic parameters. These measures make it possible to quantitate the overall performance of a CCIP or to compare the predictive performance of CCIPs which differ in either general approach (e.g., compartmental model driven vs. plasma efflux approach), pump mechanics, software algorithms, or pharmacokinetic parameter sets.

Adult↗

The use of an infusion pump in arthroscopy.

The use of an infusion pump is an effective method of irrigating the joint in arthroscopy. A Sarns roller blood pump is used to pump fluid into the joint through the arthroscope with outflow by gravity drainage through a plastic cannula. Flow and pressure can be adjusted independently. Measurements were made of calf, knee, and thigh swelling after arthroscopy in 42 patients; the average swelling of each was less than 1 cm. In 45 patients, the average rate of flow through the joint was 45 mm/min, with a measured outflow of 40 mm/min. Intraarticular pressure greater than 200 mm Hg can be obtained with the pump, compared with maximum pressures only slightly greater than 100 mm Hg with gravity inflow alone. The operator must carefully monitor the system; retention of excessive fluid can lead to postoperative swelling and morbidity.

Adolescent↗

[Malfunctioning of infusion pumps due to interference from an electrosurgical unit].

We observed the incidence of pump errors by the interference from the electrosurgical unit (Vallylab, Force 4B) set at coagulation or cut mode, with three infusion pumps: Terumo STC-523, STC-525 and STC-525-01. The STC-525-01 painted with electrically conductive paint inside was used during electrosurgery on experimental basis. Malfunctioning of the STC-523 pump occurred frequently by using electrosurgical unit set at coagulation mode and placed close to the pump. The STC-525-01 showed markedly lower incidence of malfunctioning. Therefore, the STC-252-01 pump can be used safely during electrosurgery. Additionally, we discovered, through an estimation of radiated electrical field around the electrosurgical unit, the cable of an active electrode was important as an interference source. To minimize electrosurgical interferences, we propose the following recommendations; 1) keeping the infusion pump and its AC line as far as possible from the active electrode cable, 2) keeping the output of electrosurgical unit as low as possible, 3) operating the pump with its internal battery power supply, and 4) monitoring the operation of the pump while using electrosurgery.

Electricity↗

[Effect of treatment of idiopathic hypogonadotropic hypogonadism with an LHRH infusion pump].

Treatment of idiopathic hypogonadotropic hypogonadism with an intermittent LHRH infusion pump is more physiologic than the repeated injections of gonadotropin previously used. The results of treating 7 patients, 5 males and 2 females, with this new method are presented. A better FSH and LH response to the LHRH is achieved during treatment which results in a increase in testosterone production but not so of estradiol. The size of the testicles as well as the amount of pubic hair increased in all cases, although fertility was only achieved in one patient, who also showed the best testicular response. We may conclude that treatment with intermittent infusion of LHRH is an important innovation although only partially successful since there are resistant cases and the final outcome is not better than with other methods.

Adult↗

The implantable "Infusaid" infusion pump. The Sydney experience using 5-fluorouracil.

The experience is reported of the use of the totally implantable "Infusaid" infusion pump in the treatment of 14 patients in our combined clinics for metastatic carcinoma in the liver by means of the antimetabolite 5-FU. At the time of this study the more active antimetabolite 5-FUDR was not available. A comparison is made of overseas reports of the use of 5-FUDR in the Infusaid infusion pump with the experience, in our clinic, of the use of 5-FU.

Australia↗

Role of scintigraphy in establishing optimal perfusion in hepatic arterial infusion pump chemotherapy.

Since 1982, physicians at the Medical College of Ohio, Toledo, have performed 41 hepatic intraarterial chemotherapy infusion pump implantations for palliative treatment of metastatic liver disease from various primary tumors of the gastrointestinal tract. Radionuclide hepatic arterial pump imaging has proven to be a very reliable, cost-effective, and uncomplicated method of evaluating liver perfusion as it relates to pump function, catheter integrity, and positioning. Confirmation of satisfactory hepatic perfusion is the key to acceptable treatment by this modality. In combination with periodic computed tomography (CT) scanning and CEA determinations, scintigraphy plays a major role in establishing effective therapy and aids in determining causal factors behind treatment failures.

Adult↗