At least 163 records · Page 9Linked to original sources

High-Flow Nasal Oxygen and the Risk of Gastric Insufflation: A Systematic Review and Meta-Analysis Supplemented by Narrative Synthesis.

High-flow nasal oxygen (HFNO) generates positive airway pressure, raising concerns about gastric insufflation and aspiration risk. Although most studies report minimal or no gastric distension, some suggest significant changes. This systematic review and meta-analysis applied the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) framework to evaluate the effect of HFNO on gastric insufflation and related markers across clinical settings. We searched Medline, Embase, Emcare, and CINAHL through August 2025 for studies reporting qualitative or quantitative markers of gastric insufflation during HFNO use, including comet-tail artifacts, antral cross-sectional area, and gastric volume. Eligible designs included randomized trials, observational and volunteer studies, and case reports. Methodological quality was evaluated using the Mixed Methods Appraisal Tool, and certainty of evidence was rated with GRADE. Meta-analysis was performed for outcomes reported in two or more studies. Six randomized trials, five observational studies, two volunteer studies, one case series, and two case reports were included. Observational studies primarily assessed outcomes before and after HFNO intervention. Pooled analysis of four randomized controlled trials (RCTs; n = 375) showed HFNO significantly reduced gastric insufflation compared with face-mask ventilation during elective peri-intubation (risk ratios [RR] = 0.32; 95% confidence interval [CI], 0.19-0.52; P < .00001; I 2 = 0%), rated moderate-certainty. For antral cross-sectional area, pooled analysis of three RCTs (n = 318) found no significant difference between HFNO and face-mask ventilation (MD -0.33 cm 2 ; 95% CI, -0.72 to 0.05; P = .09; I 2 = 74%), rated moderate-certainty. Observational studies assessing pre- and post-HFNO changes showed no significant increase in antral cross-sectional area (MD 0.08 cm 2 ; 95% CI, -0.29 to 0.45; P = .67; I 2 = 0%) and no significant change in gastric liquid volume (MD -0.01 ml/kg; 95% CI, -0.07 to 0.06; P = .80; I 2 = 0%), both rated low certainty. Nonpooled data suggested possible increases in critically ill patients, but the evidence was of very low certainty. A single study assessing microaspiration found HFNO reduced gastroesophageal reflux and prevented microaspiration compared with face-mask ventilation. No clinically significant aspiration events were reported across studies. Moderate-certainty evidence supports HFNO as safe regarding gastric insufflation and antral cross-sectional area in most elective and procedural contexts. Low-certainty evidence suggests no increase in gastric volume. Caution is warranted due to limited, low-to-very-low-certainty evidence at higher flow rates and among critically ill patients. Larger multicenter trials and robust observational studies are necessary to confirm safety in these settings.

Humans↗

Minimizing diaphragmatic injury during radiofrequency ablation: efficacy of intraabdominal carbon dioxide insufflation.

OBJECTIVE: The purpose of our study was to determine whether intraperitoneal insufflation of carbon dioxide (CO(2)) reduces adjacent diaphragmatic injury. MATERIALS AND METHODS: In seven pigs under anesthesia, a 17-gauge percutaneous insufflation needle was inserted in the infraumbilical midline using a standard insufflator. Three to six liters of CO(2) was infused into the peritoneal space to achieve at least a 1-cm separation between the liver and the diaphragm and maintained by a pressure of 8-10 mm Hg. Seven control lesions in six historical controls were used. In addition, five lesions were created in one animal from this cohort who served as a control. Superficial areas of liver separated from diaphragm were fluoroscopically targeted for radiofrequency ablation, and several 2-cm-diameter radiofrequency lesions were generated. The pigs were sacrificed at 48 hr, and at laparotomy, the liver surface was inspected and sectioned to select lesions with centers within 1 cm of the surface. The thermal injury to the corresponding adjacent diaphragm was examined to determine the depth of injury. Diaphragmatic injury was graded on a scale from 0 to III (0, no injury; I, mild injury to one-third thickness; II, moderate injury to two-thirds thickness; III, severe injury to full thickness.) RESULTS: Of 72 total lesions created, 60 had centers less than 1 cm from the liver surface (i.e., superficial) at laparotomy. Of these 60 lesions, 55 caused no significant diaphragmatic injury, two caused grade I injury and three caused grade III injury. In comparison, seven of seven historic superficial control lesions and five of five superficial radiofrequency control lesions from the current cohort caused grade III injury. Superficial radiofrequency lesions created after intraperitoneal CO(2) insufflation caused significantly less (p < 0.01) diaphragmatic injury. CONCLUSION: We have shown that in pigs, intraperitoneal CO(2) insufflation helped significantly reduce severe diaphragmatic injury when superficial hepatic radiofrequency ablation was performed.

Animals↗

Cardiopulmonary effects of intrathoracic insufflation in dogs.

This study was designed to quantify the effects of incremental positive insufflation of the intrathoracic space on cardiac output (CO), heart rate (HR), arterial pressure (AP), central venous pressure (CVP), and percent saturation of hemoglobin with oxygen (SPO2) in anesthetized dogs. Seven healthy, adult dogs from terminal teaching laboratories were maintained under anesthesia with isoflurane delivered with a mechanical ventilator. The experimental variables were recorded before introduction of an intrathoracic catheter, at intrathoracic pressures (IP) of 0 mm Hg, 3 mm Hg insufflation, and additional increments of 1 mm Hg insufflation thereafter until the SPO2 remained <85% despite increases in minute volume. Finally the variables were measured again at 0 mm Hg IP. The cardiac output and systolic and diastolic AP significantly (P < 0.05) decreased at 3 mm Hg IP. Significant decreases in SPO2 were seen at 10 mm Hg IP. Significant increase in CVP was noted at 6 mm Hg IP. Heart rate decreased significantly at 5 to 6 mm Hg IP but was not decreased above 6 mm Hg IP. Given the degree of CO decrease at low intrathoracic pressures, insufflation-aided thoracoscopy should be used with caution and at the lowest possible insufflation pressure. Standard anesthetic monitoring variables such as HR and AP measurements may not accurately reflect the animal's cardiovascular status.

Anesthesia↗

Tracheal gas insufflation and related techniques to introduce gas flow into the trachea.

Over the past 50 years, a variety of techniques have been developed that have in common the insufflation of gas into the central airway to facilitate carbon dioxide (CO2) clearance. These include continuous insufflation of oxygen, transtracheal jet ventilation, high frequency jet ventilation, transtracheal oxygen administration, intratracheal pulmonary ventilation, and tracheal gas insufflation (TGI). Continuous insufflation of oxygen is a technique used to enhance CO2 removal in the presence of apnea. Transtracheal jet ventilation and high frequency jet ventilation promote bulk gas flow into the lungs. Some techniques, such as transtracheal oxygen administration, provide insufflation of oxygen as an adjunct to spontaneous ventilation. However, other techniques, such as TGI, are used as an adjunct to positive pressure ventilation. Intratracheal pulmonary ventilation provides positive pressure ventilation while bypassing the upper airway. Although some of these techniques are promising adjuncts to mechanical ventilation and may help reduce ventilator-associated lung injury, much remains to be learned about their role in the care of patients with acute lung injury.

Equipment Design↗

[Effects of intraperitoneal insufflation on hematogenous seeding of abdominal infections. Preliminary results of an experimental study in rats].

Most laparoscopic procedures require the creation of a pneumoperitoneum. In order to evaluate the potential hazards of bacteriemia related to insufflation, we conducted a study in the rat. Two groups of 20 Wistar rats were used for this study. Peritonitis was induced by opening the terminal ileum. Twenty-four hours later, 20 rats were insufflated at a mean pressure of 6 mm Hg (Group I). After one hour of insufflation, an hemoculture was performed via direct intracardiac puncture and in the other group of 20 non-insufflated rats (Group NI). Five of the 18 hemoculture were positive in the Gr. I (27.7%) and 6 out of 20 in the Gr. NI (30%) (chi 2 = 0.238 p = 0.62 non significant difference). These results suggest that insufflation does not facilitate hematogenous dissemination of bacteria from intraperitoneal sepsis in this animal model.

Animals↗

Effects of abdominal insufflation with nitrous oxide on cardiorespiratory measurements in spontaneously breathing isoflurane-anesthetized dogs.

Cardiorespiratory effects of abdominal insufflation were evaluated in 8 dogs during isoflurane anesthesia. Each dog was studied 3 times, in 1 of the following orders of insufflation pressures: 10-20-30, 20-30-10, 30-20-10, 10-30-20, 20-10-30, and 30-10-20 mm of Hg. Anesthesia was induced by use of a mask, dogs were intubated, and anesthesia was maintained by isoflurane in 100% oxygen. After instrumentation, baseline values were recorded (time 0), and the abdomen was insufflated with nitrous oxide. Data were recorded at 5, 10, 15, 20, 25, and 30 minutes after insufflation. The abdomen was then desufflated, with recording of data continuing at 35 and 40 minutes. Mean arterial pressure increased at 5 minutes during 20 mm of Hg insufflation pressure, and from 20 to 30 minutes during 30 mm of Hg pressure. Tidal volume decreased from 5 to 30 minutes during 10 and 20 mm of Hg pressures, and from 5 to 40 minutes during 30 mm of Hg pressure. Minute ventilation decreased at 10 and 20 minutes during 20 mm of Hg pressure. End-tidal CO2 concentration increased from 5 to 30 minutes during 20 and 30 mm of Hg pressure. The PaCO2 decreased at 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure. Values for pH decreased from 10 to 30 minutes during 20 and 30 mm of Hg pressures. The PaO2 decreased from 20 to 40 minutes during 10 mm of Hg pressure, at 30 minutes during 20 mm of Hg pressure, and from 10 to 40 minutes during 30 mm of Hg pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

Abdomen↗

Air insufflation: a useful adjunct to the single contrast barium enema for the evaluation of the rectum.

We examined whether insufflation of a small volume of air after a single-contrast barium enema would improve evaluation of the rectum. Eighty patients presenting for barium enema by single-contrast technique underwent examination of the colon including spot films with fluoroscopy and palpation during introduction of the barium and filled overhead views, using standard apparatus and technique. The examination was completed by draining barium from the rectum only, following which air in the barium enema bag was squeezed back into the rectum and three views of the rectum obtained (lateral, left posterior oblique, and frontal). Two reviewers then chose the best image of the rectum from each study with relevance to luminal distention and visibility of surface detail of the rectum. Following air insufflation, improved surface detail visualization was recognized by both reviewers in 69 (86%) patients and by one reviewer in 10 (12%) patients, a statistically significant observation (P < 0.0001). There was a trend towards improved rectal distention, recognized by both reviewers in 37 (46%) patients and by one reviewer in 18 cases (22%). In 25 (31%) patients neither reviewer recognized any improvement in rectal distention. Rectal abnormalities were identified in nine cases; there were two large carcinomas, two radiation strictures, two rectal fistulae, two small rectal polyps (5 and 7 mm), and one case of prolapsing rectal mucosa. All rectal abnormalities were visible on the air insufflation views. In the two cases of suspected rectal polyp and one of the cases of rectal fistula, the findings were not visible on the initial barium filled views. A normal rectum was observed in 71 cases. Follow-up of these 71 patients found no later evidence of any rectal abnormalities. Improved filling of the proximal colon following air insufflation was observed in 12 (15%) patients, an additional and unexpected benefit of this maneuver. Air insufflation is a simple addition to the SCBE study that improves visualization of the rectum.

Adult↗

Evaluation of mechanism of increased intracranial pressure with insufflation.

BACKGROUND: Previous studies have documented an increase in intracranial pressure with abdominal insufflation, but the mechanism has not been explained. METHODS: Nine 30-35-kg domestic pigs underwent carbon dioxide insufflation at 1.5 l/min. Intracranial pressure (ICP), lumbar spinal pressure (LP), central venous pressure (CVP), inferior vena cava pressure (IVCP), heart rate, systemic arterial blood pressure, pulmonary arterial pressure, cardiac output, heart rate, respiratory rate, temperature, and end-tidal CO2 were continuously measured. Mechanical ventilation was used to maintain a constant pCO2. Measurements were recorded at 0, 5, 10, and 15 mmHg of abdominal pressure with animals in supine, Trendelenburg (T), and reverse Trendelenburg (RT) positions. Prior to recording measurements, the animals were allowed to stabilize for 40 min after each increase in abdominal pressure and for 20 min after each position change. RESULTS: The animals showed a significant increase in ICP (mmHg) with each 5-mmHg increase in abdominal pressure (0 mmHg: 14 +/- 1.7; 5 mmHg: 19.8 +/- 2.3, p < 0.001; 10 mmHg: 24.8 +/- 2.5, p < 0.001; 15 mmHg: 29.8 +/- 4.7, p < 0.01). The ICP at 15 mmHg abdominal pressure increased further in the T position (39 +/- 4, p < 0.01). Insufflating in the RT position did not significantly reduce the increase in ICP. The IVCP (mmHg) increased with increased abdominal pressure (0 mmHg: 11.5 +/- 6.2, 15 mmHg: 22.1 +/- 3.5, p < 0.01). This increase correlated with the increase in ICP and LP (r of mean pressures >/=0.95). There was no significant change in CVP. CONCLUSIONS: This study suggests that care may be needed with laparoscopy in patients at risk for increased ICP due to head injury or a space occupying lesion. The mechanism of increased ICP associated with insufflation is most likely impaired venous drainage of the lumbar venous plexus at increased intraabdominal pressure. Further studies of cerebral spinal fluid movement during insufflation are currently underway to confirm this hypothesis.

Animals↗

Tumor implantation following laparoscopy using different insufflation gases.

BACKGROUND: Laparoscopic manipulation of malignancies is associated with an increased incidence of metastasis to port sites in experimental models. This study investigated the effect of different insufflation gases on the implantation of a tumor cell suspension following laparoscopic surgery in an established small animal model. METHODS: Forty Dark Agouti rats underwent laparoscopy and the introduction into the peritoneal cavity of a tumor cell suspension. The insufflating gas used for each procedure was one of the following gases (10 rats in each group): carbon dioxide (CO2), nitrous oxide (N2O), helium, and air. The rats were killed 7 days after surgery, and the peritoneal cavity and port sites were examined for the presence of tumor. RESULTS: Although no significant differences were seen between air, CO2, and N2O insufflation groups, tumor involvement of peritoneal surfaces was less likely following helium insufflation. CONCLUSION: The results of this study suggest that tumor metastasis to port sites following laparoscopic surgery may be influenced by the choice of insufflation gas. In this study, helium was associated with reduced tumor growth.

Adenocarcinoma↗

Renal effects of CO2 insufflation: oliguria and acute renal dysfunction in a rat pneumoperitoneum model.

OBJECTIVE: To determine the mechanism by which oliguria develops during raised intra-abdominal pressure secondary to CO2 insufflation, we created a rat pneumoperitoneum model. METHODS: Male Sprague-Dawley rats (n = 67) were organized into three groups. Each group was subjected to abdominal pressures of 0 (control), 5, or 10 mm Hg, over one, two, and four hours. Fourteen additional rats underwent a two-hour period of 10 mm Hg insufflation pressure followed by desufflation to 0 mm Hg. Urine output (UO) and serum creatinine levels were measured both during insufflation at one, two, and four hours, and two, four, ten, and twenty-two hours following its release. These measurements were compared to control values at each time point. Ultrasonic flow probes placed around both the inferior vena cava (IVC) and abdominal aorta during insufflation characterized the effects of increased abdominal pressure on blood flow. The flow rate was determined at insufflation pressures of 0 (control, 100% flow) to 25 mm Hg. RESULTS: Rats subjected to 10 mm Hg pressure had significant decreases in UO (oliguria) compared to controls for up to four hours (P < 0.01). There were no significant differences in UO in the control or 5 mm Hg groups over each time interval. While a reduction in UO was observed at two, four, and ten hours postrelease, significance was achieved only at ten hours (P < 0.006). By twenty-two hours postrelease, no differences in UO were observed. Serum creatinine elevations declined two hours postdesufflation. IVC flow was reduced by 92.9 percent at 10 mm Hg, while arterial flow decreased by 46.4 percent. Flow was restored to preinsufflation levels after release of pneumoperitoneum. CONCLUSIONS: Oliguria can be produced in rats undergoing pneumoperitoneum. The renal effects of pneumoperitoneum are most likely related to renal vascular insufficiency from central venous compression.

Acute Disease↗

Hemodynamic effects of carbon dioxide insufflation under single-lung ventilation during thoracoscopy.

BACKGROUND: The hemodynamic effects of carbon dioxide insufflation under single-lung ventilation were studied in 22 consecutive thoracoscopic harvests of the left internal mammary artery, which was used for minimally invasive coronary artery bypass grafting. METHODS: An electrocardiograph, arterial catheter, Swan-Ganz catheter, and transesophageal echocardiograph were used to monitor seven hemodynamic variables. Baseline data were obtained during ventilation of both lungs and the measurements were repeated after the left lung was collapsed and at 5 and 30 minutes after hemithorax insufflation with low-flow (2 to 3 L/minute) carbon dioxide gas was begun. The intrapleural pressure was maintained at 8 to 10 mm Hg. RESULTS: Thoracoscopic harvest of the internal mammary artery was completed in all cases with a mean insufflation time of 44+/-12 minutes. There were no significant changes in the mean arterial pressure, heart rate, cardiac index, and left ventricular ejection fraction throughout the procedure, whereas the central venous pressure, mean pulmonary arterial pressure, and pulmonary capillary wedge pressure (p < 0.05 for each variable) during insufflation. CONCLUSIONS: Low-flow carbon dioxide insufflation into the left hemithorax with an intrapleural pressure of 8 to 10 mm Hg under selective right-lung ventilation does not compromise the human heart with normal to moderately depressed function and can be an efficacious adjunct in specific thoracoscopic procedures.

Aged↗

Effects of intraabdominally insufflated carbon dioxide and elevated intraabdominal pressure on postoperative gastrointestinal transit: an experimental study in mice.

BACKGROUND/PURPOSE: Postoperative ileus after abdominal operations is thought to be related to the degree of surgical trauma, and it has been shown that the simple act of opening the peritoneum can decrease gastrointestinal motility. Accordingly, some investigators have shown a reduction in the duration of postoperative ileus after laparoscopic procedures. It is not clear, however, if this reduction is secondary to less manipulation of the viscera or to the lack of an abdominal incision. The aim of this study was to determine the effect of intraabdominal insufflation with CO2 on postoperative gastrointestinal transit. METHODS: Twenty-eight male mice weighing between 25 and 30 g were divided randomly into 4 groups: Control (unoperated), Incision (conventional laparotomy), Cecal (laparotomy plus cecal manipulation), and Insufflation (abdominal insufflation with CO2). Postoperative gastrointestinal motility was assessed by weighing total fecal output over the first 15 postoperative hours. RESULTS: Fecal pellet output over 15 hours in the untreated control group was 1.20 +/- 0.12 g. In mice subjected to peritoneal incision alone, fecal pellet output was significantly decreased to 0.82 +/- 0.11 g (P < .05). However, in mice subjected to abdominal insufflation with CO2, fecal pellet output was not significantly different from untreated controls (1.2 +/- 0.05 g; not significant). Fecal pellet output was markedly reduced by incision combined with cecal manipulation (0.24 +/- 0.02 g, P < .01). CONCLUSIONS: The current study findings show that abdominal insufflation, in a procedure similar to that used during laparoscopic surgery, had no measurable effect on gastrointestinal transit in awake mice. This suggests that the lack of an abdominal incision can contribute to a reduced postoperative ileus after abdominal surgery.

Abdomen↗

Gastric insufflation pressure, air leakage and respiratory mechanics in the use of the laryngeal mask airway (LMA) in children.

BACKGROUND: The objective of the present study was to evaluate the prelaryngeal position of the laryngeal mask airway (LMA(TM)) in children, and to determine the influence of mask positioning on gastric insufflation and oropharyngeal air leakage. METHODS: A total of 100 children, 3-11 years old, scheduled for surgical procedures in the supine position under general anaesthesia were studied. After clinically satisfactory LMA placement, tidal volumes were increased stepwise until air entered the stomach, airway pressure exceeded 30 cmH(2)O, or air leakage from the mask seal prevented further increases in tidal volume. LMA position in relation to the laryngeal entrance was verified using a flexible bronchoscope. RESULTS: The insertion of the LMA with a clinically satisfactory position was achieved in all patients at the first attempt. Gastric air insufflation occurred in five of 49 patients with malpositioned LMA. No incident of gastric air insufflation was observed in 51 patients with correctly positioned LMA. The minimum inspiratory pressure leading to mask leakage was 17 cmH(2)O for incorrectly positioned LMA, and 25 cmH(2)O for correctly positioned LMA. Clinically unrecognized LMA malposition was associated with a significantly increased incidence of either oropharyngeal leakage (r = 0.59; P = 0.0001) or gastric insufflation (r = 0.25; P = 0.01). CONCLUSIONS: Clinically undetected LMA malpositioning is a significant risk factor for gastric air insufflation in children between 3 and 11 years, undergoing positive pressure ventilation, especially at inspiratory airway pressures above 17 cmH(2)O.

Air↗

Adhesion formation in intubated rabbits increases with high insufflation pressure during endoscopic surgery.

The aim of the study was to test the hypothesis that the increase in adhesion formation by CO(2) pneumoperitoneum is caused by mesothelial hypoxaemia. Therefore the effect of the intra-abdominal pressure together with the flow rate upon adhesion formation was evaluated in rabbits following laser and bipolar lesions during endoscopic surgery using humidified CO(2) at 35 +/- 1 degrees C. The intra-abdominal pressure and flow rate were 5 mmHg and 1 l/min in group 1 (n = 5), 5 mmHg and 10 l/min in group 2 (n = 4), 20 mmHg and 1 l/min in group 3 (n = 5) and 20 mmHg and 10 l/min in group 4 (n = 4) respectively. A rapid and reliable intubation method for rabbits was developed to permit high insufflation pressure. By two-way analysis of variance, total adhesion scores following a laser lesion increased with flow rate (P = 0.0003) and insufflation pressure (P = 0.002). Total adhesion scores of bipolar lesions increased with pressure (P = 0.02) but not with flow rate (P = 0.1). The total adhesion scores of laser and bipolar lesions together increased with flow rate (P = 0.005) and with insufflation pressure (P = 0.004). There was no statistical interaction between flow rate and insufflation pressure. In conclusion, the insufflation pressure in endoscopic surgery with CO(2) pneumoperitoneum is a co-factor in adhesion formation, together with desiccation.

Analysis of Variance↗

Laryngeal mask airway position and the risk of gastric insufflation.

UNLABELLED: A potential risk of the laryngeal mask airway (LMA) is an incomplete mask seal causing gastric insufflation or oropharyngeal air leakage. The objective of the present study was to assess the incidence of LMA malpositions by fiberoptic laryngoscopy, and to determine their influence on gastric insufflation and oropharyngeal air leakage. One hundred eight patients were studied after the induction of anesthesia, before any surgical manipulations. After clinically satisfactory LMA placement, tidal volumes were increased stepwise until air entered the stomach, airway pressure exceeded 40 cm H2O, or air leakage from the mask seal prevented further increases in tidal volume. LMA position in relation to the laryngeal entrance was verified using a flexible bronchoscope. The overall incidence of LMA malpositions was 40% (43 of 108). Gastric air insufflation occurred in 19% (21 of 108), and in 90% (19 of 21) of these patients, the LMA was malpositioned. Oropharyngeal air leakage occurred in 42%, and was independent of LMA position. We conclude that clinically unrecognized LMA malposition is a significant risk factor for gastric air insufflation. IMPLICATIONS: Routine placement of laryngeal mask airways does not require laryngoscopy. In our study, fiberoptic verification of mask position revealed suboptimal placement in 40% of cases. Such malpositioning considerably increased the risk of gastric air insufflation.

Adult↗

Low-flow endobronchial insufflation with air for 2 hours of apnea provides ventilation adequate for survival.

We tested the efficacy of low-flow endobronchial insufflation (EI) with air, as it may be useful in emergency situations in which positive-pressure mechanical ventilation is not possible. The only equipment required is a source of compressed air with flow controller and a specially designed insufflation catheter. The insufflation catheter has forked ends that can be positioned blindly in the mainstem bronchi. In six anesthetized, apneic dogs averaging 9.6 kg, we determined that the average air flow needed to maintain PaO2 above 45 mm Hg and PaCO2 below 65 mm Hg after 30 min was 2.5 L/min. At these flow rates, all dogs survived 2 h of endobronchial insufflation with no neurologic dysfunction. The small internal diameters (0.8 mm) of the catheter ends increase gas exit velocity and allow for adequate oxygenation and CO2 removal at low flow rates. Endobronchial insufflation could also be employed with cricothyroidotomy and a compressor for emergency situations in the field involving mass casualties, where oxygen supplies and equipment are limited.

Animals↗

Impact of a warm gas insufflation on operating-room ergonometrics during laparoscopic gastric bypass: a pilot study.

BACKGROUND: With the use of various laparoscopic instruments, the work of operating-room (OR) personnel has increased significantly. The impact of warm gas insufflation on the ergonometrics of the OR was studied, using one of the most involved laparoscopic surgical procedures, Roux-en-Y gastric bypass (RYGBP) for morbid obesity, to assess if use of warm gas insufflation decreases the work of the OR personnel. METHODS: 20 patients between August 2003 and January 2004 (6 months) were divided into 2 groups. 10 patients with age 50+/-10 years and BMI 48+/-8 underwent laparoscopic RYGBP using a warmed CO2 insufflator (WI). These results were compared to 10 patients with age 53+/-15 years and BMI 51+/-7 using a non-warmed CO2) insufflator (NWI). Total time of surgery (TOS), time spent cleaning the laparoscope (TCS), time spent changing warm saline (TWS), time spent using anti-fog (TAF), and time the circulating nurse was involved in these activities (TN) were compared. Statistical analysis used a two-sample, Student t-test with unequal variances. RESULTS: The 2 bariatric populations were almost similar in age and BMI. TCS (P<0.0003), TWS (P<0.0001) and TN (P<0.0002) took significantly less time in the WI group, while TOS and TAF were similar. CONCLUSION: Use of warmed CO2 insufflation had a significant impact on TCS, TWS and TN. This impacts the ergonometrics of the OR, allowing more time for the personnel and surgeons to concentrate on the surgery.

Adult↗

The effects of intranasal insufflation of growth hormone releasing factor analogue GRF 1-29 NH2 on growth hormone secretion in children with short stature.

The effects of intranasal insufflation of the synthetic growth hormone releasing factor GRF 1-29-NH2 on serum growth hormone (GH) were investigated in five healthy prepubertal children with short stature. 100 micrograms/kg/body weight of synthetic GRF 1-29-NH2, 500 micrograms in 100 microliters water, were insufflated intranasally after careful cleaning of the nose. GRF 1-29-NH2 induced a prompt rise of serum GH levels with peak values at 15 minutes in all children investigated. Peak serum GH values were 28.3 +/- 12.0 ng/ml (mean +/- SD), range 17.1 - 47.6 ng/ml; delta GH was 27.0 +/- 12.2 ng/ml (mean +/- SD). Serum GH levels were still significantly raised 120 minutes after the insufflation of GRF 1-29-NH2 (p less than 0.05). No side effects, except for burning of the nasal mucosa in one patient, were observed. The results of this study demonstrate that intranasal insufflation of synthetic GRF 1-29-NH2 induces a prompt release of GH in otherwise normal children with short stature. Pulsatile intranasal insufflation of GRF 1-29-NH2 probably could be used for the treatment of some children with GH deficiency due to a defect at a suprapituitary level.