Philips issues voluntary device correction for phantom pulse oximetry readings with Philips physiologic monitors using multi-measurement servers.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Flavone acetic acid (FAA), a new drug with broad activity against transplanted solid tumors of mice, induces nonrepairable DNA single strand breaks that correlate with therapeutic efficacy. To test the hypothesis that the inability of the cells to repair single strand breaks is associated with a disruption of tumor energy metabolism, in vivo 31P nuclear magnetic resonance (NMR) spectra were acquired from s.c. implanted Glasgow osteogenic sarcomas in C57BL/6 x DBA/2 F1 mice both before and after treatment with FAA i.v. at 100, 150, or 200 mg/kg and from a control (no treatment) group (n = 4 in each group). While FAA produced a dose-dependent decrease in both the nucleoside triphosphates level and pH, only treatment with an efficacious dose of 200 mg/kg resulted in both a reduction in pH and a complete loss of nucleoside triphosphates from the NMR spectrum at 4 h with no recovery until 48 h and little recovery out to 72 h. The ATP concentration determined by high pressure liquid chromatography in a parallel set of experiments was 5.59 +/- 1.16 (SE) mumol/g (wet weight) in control tumors (n = 9) and 0.24 +/- 0.12 mumol/g (wet weight) at 4 h after 200 mg/kg FAA (n = 7). To examine the possibility that the loss of ATP and decreased pH are associated with a reduction in tumor blood flow, we used 2H NMR to monitor the washout of D2O injected directly into the tumor both before and 4 h after treatment with 200 mg/kg FAA. The pretreatment tumor blood flow of 12.4 +/- 1.7 ml/min/100 g was reduced to 1.9 +/- 0.5 ml/min/100 g at 4 h after treatment (n = 3). The FAA-induced reduction of both tumor blood flow and ATP may play an important role in its mechanism of action and should be considered in the combination of FAA with other drugs or therapeutic modalities. In addition, because 31P NMR can be used clinically, it should provide a nonambiguous early indicator of activity for clinical trials of FAA.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Healthy physiological systems exhibit irregular variability whereas diseased systems display decreased signal variability or greater regularity. The objective of this article is to report a case series of critically ill adults who displayed ultra low-frequency periodic sinusoidal oscillations in cardiac output (ULF-CO) that were discovered during a clinical study testing software for continuous physiological monitoring. Data were collected from 13 critically ill surgical and trauma patients who required continuous cardiac output monitoring. Physiologic data were collected from clinical monitors. The computerized time series of cases displaying CO oscillations were manually reviewed. Ten patients with sepsis or the systemic inflammatory response syndrome exhibited 18 episodes of ultra low-frequency periodic oscillations (ULF-CO) with frequencies ranging from 0.0028 to 0.000053 Hz (periods, 6 to 316 min). Intensive care unit mortality rate was 50%. The amplitude and coefficient of variation of cardiac output during ULF-CO ranged from 0.1-4.6 L and 3.9-14.3%, respectively. Duration of ULF-CO ranged from 4-108.1 h. ULF-CO could not be explained as a result of patterned artifact from measurement error or therapeutic intervention. ULF-CO may be a pathophysiologic marker that might serve the diagnosis, prognosis, and treatment of critical illness.
Physiologic profile monitoring was performed on 18 elderly patients (mean age, 71.3 +/- 11.7 years) with major burns (mean, 49% +/- 17% BSA) on days 1 to 4. Nine had associated inhalation injury. Ten patients survived more than 10 days. Degree of myocardial dysfunction in response to burn injury is unpredictable. Sixteen of the total 18 patients needed inotropic support. Cardiac output is probably a more accurate means of assessing efficacy of resuscitation than hourly urine output. Maintenance of cardiac index at higher than normal levels is a physiologic necessity. Failure of cardiac index to remain high after 3 days predicted nonsurvival in this group of patients. In presence of combined cutaneous and inhalation burn injury fluid requirement is unpredictable, and the optimum resuscitation in these patients merits further definition. Physiologic profile monitoring in these older patients is a very useful guide to the precise management of fluid resuscitation, early detection, and treatment of ventricle dysfunction, and results in improved survival.
OBJECTIVE: To evaluate an ambulatory physiological monitoring system during a mountaineering expedition. We hypothesized that the Environmental Symptoms Questionnaire, combined with frequent measurement of oxygen saturation and core temperature, would accurately identify cases of environmental illness. METHODS: Twelve military mountaineers took a daily Environmental Symptoms Questionnaire, monitored fingertip oxygen saturations, and recorded core temperatures while climbing a 4,949-m peak. Illnesses identified by the system were compared with those identified by spontaneous reports. RESULTS: The system correctly identified one case of high-altitude pulmonary edema and two illnesses that were not reported to the physician (one case of acute mountain sickness and one of self-limited symptomatic desaturation). However, it did not identify two illnesses that were severe enough to preclude further climbing (one case of sinus headache and one of generalized fatigue). CONCLUSIONS: Our monitoring system may complement, but cannot replace, on-site medical personnel during mountaineering expeditions.
Explore the source record for details and available documents.
A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s for start and stop detection.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This paper presents a scheme of a wireless multiple physiological parameters monitoring system, and gives a detail description on the hardware and software realization. This system utilizes wireless communication technology, embedded micro internet working technology and medical service technology in the remote monitoring system.
The primary physiological function of the vasculature is to support perfusion, the nutritive flow of blood through the tissues. Vascular physiology can be studied non-invasively in human subjects using imaging methods such as positron emission tomography (PET), magnetic resonance imaging (MRI), X-ray computed tomography (CT), and Doppler ultrasound (DU). We describe the physiological rationale for imaging vascular physiology with these methods. We review the published data on repeatability. We review the literature on 'before-and-after' studies using these methods to monitor response to treatment in human subjects, in five broad clinical settings: (1) antiangiogenic agents, (2) vascular disruptive agents, (3) conventional cytotoxic drugs, (4) radiation treatment, and (5) agents affecting drug delivery. We argue that imaging of vascular physiology offers an attractive 'functional endpoint' for clinical trials of anticancer treatment. More conventional measures of tumour response, such as size criteria and the uptake of fluorodeoxyglucose, may be insensitive to therapeutically important changes in vascular function.
Explore the source record for details and available documents.
Adding physiologic data to ambulatory electrocardiographic monitoring data yields information with great potential for diagnostic and therapeutic use. The ear densitogram's stability, demonstrated during exercise and under laboratory conditions, indicates its applicability to ambulatory monitoring as a source of systolic time intervals. Circuitry has been developed to feed the output of an ear densitogram pickup into one channel of a two-channel Holter monitor. Baseline studies in different postures are used to establish pulse transmission time, which permits the ear densitogram pulse to be used as a delayed aortic pulse in measuring systolic time interval. Feasibility and field studies have shown that systolic time intervals can be precisely determined by this method.
Sepsis is a common source of morbidity and mortality among critically ill patients, and targeting measures to promote early recognition and treatment of sepsis is at the forefront of many critical care initiatives. Starting formally in 1992, with the publication of the definitions of sepsis, continuous monitoring of several common physiologic parameters, including electrocardiogram, blood pressure, and oxygen saturation, have been advocated as important in the early identification and treatment of patients with sepsis. The descriptive study detailed in this article was conducted to assess the perceptions and clinical continuous physiologic monitoring practices of experienced critical care clinicians with regard to their use of common physiologic monitoring parameters in the care of patients with sepsis. A convenience sample of 100 physicians and 517 nurses completed a 20-item survey assessing perceptions and clinical monitoring practices related to the care of patients with sepsis. Results indicated that the basic parameters of electrocardiogram, invasive blood pressure, pulmonary arterial catheter monitoring, and oxygen saturation all have value in the recognition and treatment of patients with sepsis. The majority of clinicians used these parameters routinely and felt they were necessary for patient care. These results indicate that clinical practice is in concordance with current practice recommendations.