PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Optics and Refraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Evanescent field-based optical fiber sensing device for measuring the refractive index of liquids in microfluidic channels.

We report a simple optical sensing device capable of measuring the refractive index of liquids propagating in microfluidic channels. The sensor is based on a single-mode optical fiber that is tapered to submicrometer dimensions and immersed in a transparent curable soft polymer. A channel for liquid analyte is created in the immediate vicinity of the taper waist. Light propagating through the tapered section of the fiber extends into the channel, making the optical loss in the system sensitive to the refractive-index difference between the polymer and the liquid. The fabrication process and testing of the prototype sensing devices are described. The sensor can operate both as a highly responsive on-off device and in the continuous measurement mode, with an estimated accuracy of refractive-index measurement of approximately 5 x 10(-4).

Complex Mixtures↗

Pupil size and the ablation zone in laser refractive surgery: considerations based on geometric optics.

PURPOSE: To determine whether the currently accepted method of selecting a minimum ablation zone size for refractive surgery based on dark-adapted pupil diameter is substantiated by geometric optical analysis. SETTING: Department of Ophthalmology and Visual Sciences, Texas Tech University Health Sciences Center, Lubbock, Texas, USA. METHODS: An optical model of the anterior segment was developed to calculate the effective corneal refractive diameter (ECRD), which is the diameter of the area of cornea that refracts all incident light rays arising from objects along the line of sight though the physical pupil (PP). The concept of the entrance pupil (EP) was reexamined and developed, and the ECRD was calculated over a range of corneal curvatures (K), anterior chamber depths (ACDs), and EP sizes. The model was generalized to include oblique light rays. Calculations were performed using MatLab Optimization Toolbox software (The MathWorks). RESULTS: For a given EP size, the ECRD was significantly influenced by K and slightly influenced by ACD. CONCLUSIONS: For objects on the line of sight, the ECRD was smaller than the EP in all cases. Regarding rays from objects in the periphery, the ECRD expanded rapidly as the angle of oblique incidence increased. For objects on the line of sight, the ECRD is always smaller than the clinically measured pupil (EP) because the EP is substantially magnified relative to the PP. Ablation zones larger than the EP should, in theory, prevent scattered or defocused light rays from contributing to the foveal image. When considering objects in the periphery, the increase in ECRD is sufficiently rapid that current refractive procedures cannot stop scattered light from these objects from contributing to the retinal image.

Cornea↗

[Critical frequency of flashes fusion in differential diagnosis of vision disorders in children].

Critical frequency of fusion of flashes (CFFF) was measured in children by CFFF-D device recommended for clinical trials by the Ministry of Health and Medical Industry of the Russian Federation (Protocol No. 4 of June 13, 1996). A total of 213 children with central and peripheral retinal abiotrophy, partial atrophy of the optic nerve, refraction and dysbinocular amblyopia, and healthy children were examined. The most expressed changes of CFFF were observed in children with optic nerve atrophy. The CFFF-D device provides reliable results for the diagnosis.

Adolescent↗

Effect of fluorine plasma treatment on PMMA and their application to passive optical waveguides.

Poly(methylmethacrylate) (PMMA) has been a good prospect for the development of fully amorphous and highly transparent microphotonic devices. The possibilities of a hot embossing technique for the polymeric fabrication of optical waveguides were investigated in this work. A new technique based on radiofrequency plasma treatment was studied for thermal and optical properties, including glass transition temperature, thermal stability, refractive index, and optical transmission loss of PMMA. It is shown that the plasma treatment is effective in altering the functional groups of polymer surfaces without affecting the bulk properties, resulting in effective control of refractive indices and optical transmission losses for photonic applications.

Journal Article↗

Optic disc of the myopic eye: relationship between refractive errors and morphometric characteristics.

Because the optic disc in myopic eyes is different from a normal optic disc, there are many difficulties in examining the optic discs of myopic eyes. To study optic disc change due to myopia, we performed a morphometrical study of stereophotographs of 61 men, 109 eyes, who had no glaucoma history. The range of refractive error was from +0.75 diopter to -12.75 diopter, and all subjects had intraocular pressure below or equal to 21 mmHg. According to the increase in the myopic degree, the temporal slope of the disc cup was significantly decreased, but the ratio of the vertical disc diameter (VDD) to the horizontal disc diameter and the ratio of the width of peripapillary atrophy (PPA) to the VDD were significantly increased. The above results suggests that in high myopia the optic disc was tilted and the rim-cup border was indistinct and there are some problems in the estimation of the morphometric parameters. Also in evaluation of the PPA of myopic glaucoma patients, there may be some difficulty in deciding whether it is due to myopic change or glaucomatous damage.

Adolescent↗

Ocular optical aberrometer for clinical use.

Higher-order optical errors of the human eye are often responsible for reduced visual acuity in spite of an optimal spherical or cylindrical refraction. These optical aberrations are of natural origin or can result from operations in the eye that involve optical structures. The ocular aberrometer presented is based on Tscherning's aberroscope. A collimated laser beam (532 nm, 10 mW) illuminates a mask with a regular matrix of holes which forms a bundle of thin parallel rays of 0.3 mm diameter. These rays are focused by a lens in front of the eye so that their intraocular focus point is located a certain distance in front of the retina, generating a corresponding pattern of light spots on it. According to the existing ocular optical errors, this spot pattern is more or less distorted in comparison to the mask matrix. For a 6 mm pupil diameter 68 retinal spots are plottable for assessment of the optical aberrations. The retinal spot pattern is imaged onto the sensor of a low-light charge coupled device video camera by indirect ophthalmoscopy. Deviations of all spots from their ideal regular positions are measured by means of a PC, and from these values the intraocular wave front aberration is computed in the form of the sum of Zernike polynomials up to sixth order.

Eye↗

Population prevalence of tilted optic disks and the relationship of this sign to refractive error.

PURPOSE: To assess the prevalence of tilted disks and its association with refractive error and visual field defects. DESIGN: Population-based cohort study. METHODS: The Blue Mountains Eye Study examined urban Australians aged 49 years or older between 1992-1994. Of 4,433 eligible participants, 3,654 (82.4%) participated. The eye examination included logMAR visual acuity, standardized refraction, cover testing, stereoscopic optic disk photography, and Humphrey automated perimetry. Inferior or nasal optic disk tilting was graded from stereoscopic photographs. RESULTS: Of 3,583 participants with gradable photographs, inferior or nasal optic disk tilting was observed in 77 eyes of 56 participants (1.6%). The prevalence of tilted disks increased from 0.4% in eyes with astigmatism < 1.0 diopters to 17.9% in eyes with astigmatism >or= 5.0 diopters. The mean astigmatic error was 2.2 diopters in eyes with tilted disks compared with 0.7 diopters in eyes with normal disk appearance, P <.001. Myopia was present in 66.2% of eyes with tilted disks compared with 12.4% of eyes with a normal disk appearance, P <.001. The most common associated features were astigmatism (93.5%), pallor, and tessellation of the adjacent chorioretinal tissues (74.0%), situs inversus of the retinal vessels (70.1%), beta-peripapillary atrophy (64.9%), strabismus (30.4%), visual field defects (19.4%), posterior staphyloma (18.2%), inferonasal pigmentary accumulation (9.1%), and chorioretinal atrophy (5.2%). Superotemporal (33.3%) and superior (25.0%) visual field defects were most frequent. CONCLUSIONS: A tilted disk appearance was not a rare finding in our study population and was strongly associated with astigmatism and higher levels of spherical refractive error, particularly myopia. The tilted disk and its associated visual field defect should be distinguished from other sinister causes.

Age Distribution↗

Integrated optical switching based on the protein bacteriorhodopsin.

According to our earlier pioneering study, a dry film containing native bacteriorhodopsin (bR) shows unique nonlinear optical properties (refractive index change, controllable by light of different colors, greater than 2 x 10(-3)) that are in many respects superior to those of the materials presently applied in integrated optics. Here, we report on the first integrated optical application based on a miniature Mach-Zehnder interferometer (see Figs. 1 and 2) demonstrating a real switching effect by bR (efficiency higher than 90%) due to the M-state. Our results also imply that the refractive index change of the K-state (9 x 10(-4)) is high enough for fast switching.

Bacteriorhodopsins↗

Numerical study of wavelength-swept semiconductor ring lasers: the role of refractive-index nonlinearities in semiconductor optical amplifiers and implications for biomedical imaging applications.

Recent results have demonstrated unprecedented wavelength-tuning speed and repetition rate performance of semiconductor ring lasers incorporating scanning filters. However, several unique operational characteristics of these lasers have not been adequately explained, and the lack of an accurate model has hindered optimization. We numerically investigated the characteristics of these sources, using a semiconductor optical amplifier (SOA) traveling-wave Langevin model, and found good agreement with experimental measurements. In particular, we explored the role of the SOA refractive-index nonlinearities in determining the intracavity frequency-shift-broadening and the emitted power dependence on scan speed and direction. Our model predicts both continuous-wave and pulse operation and shows a universal relationship between the output power of lasers that have different cavity lengths and the filter peak frequency shift per round trip, therefore revealing the advantage of short cavities for high-speed biomedical imaging.

Amplifiers, Electronic↗

Direct optical fabrication of three-dimensional photonic crystals in a high refractive index LiNbO3 crystal.

Direct optical fabrication of 3D photonic crystals in a high refractive index LiNbO3 crystal by using the femtosecond laser-induced microexplosion method is investigated. The focal distortion, caused by the refractive index mismatch-induced spherical aberration, can be significantly reduced by using a so-called threshold fabrication method. As a result, 3D fcc photonic crystals are fabricated by stacking quasi-spherical voids layer by layer. Photonic stopgaps with suppression rates of up to 30% in the transmission spectra are observed. The angle dependence of the stopgaps is also revealed.

Journal Article↗

Spectacle lenses alter eye growth and the refractive status of young monkeys.

The influence of visual experience on ocular development in higher primates is not well understood. To investigate the possible role of defocus in regulating ocular growth, spectacle lenses were used to optically simulate refractive anomalies in young monkeys (for example, myopia or nearsightedness). Both positive and negative lenses produced compensating ocular growth that reduced the lens-induced refractive errors and, at least for low lens powers, minimized any refractive-error differences between the two eyes. These results indicate that the developing primate visual system can detect the presence of refractive anomalies and alter each eye's growth to eliminate these refractive errors. Moreover, these results support the hypothesis that spectacle lenses can alter eye development in young children.

Accommodation, Ocular↗

Thickness measurements on transparent substrates based on reflection ellipsometry. I. Optical effects of high-refractive-index additional layers.

Theoretical studies were conducted for thickness measurements using transparent substrates on the external and internal reflection configurations. For three-phase systems consisting of ambient, film, and substrate, the refractive index of the substrate could be optimized to obtain the high sensitivity of an ellipsometric quantity delta to the film thickness and the small susceptibility of delta to errors in the incident angle. It was shown that the combination of an ordinary glass substrate and an additional dielectric layer with an appropriate layer thickness works as a synthetic high-index single substrate (SHIS). The optical effect of the combination was approximately described by use of the effective refractive index of SHIS. A method to select the refractive index of the additional layer was also given.

Journal Article↗

Microstructure-related properties at 193 nm of MgF2 and GdF3 films deposited by a resistive-heating boat.

MgF2 and GdF3 materials, used for a single-layer coating at 193 nm, are deposited by a resistive-heating boat at specific substrate temperatures. Optical characteristics (transmittance, refractive index, extinction coefficient, and optical loss) and microstructures (morphology and crystalline structure) are investigated and discussed. Furthermore, MgF2 is used as a low-index material, and GdF3 is used as a high-index material for multilayer coatings. Reflectance, stress, and the laser-induced damage threshold (LIDT) are studied. It is shown that MgF2 and GdF3 thin films, deposited on the substrate at a temperature of 300 degrees C, obtain good quality thin films with high transmittance and little optical loss at 193 nm. For multilayer coatings, the stress mainly comes from MgF2, and the absorption comes from GdF3. Among those coatings, the sixteen-layer design, sub/(1.4L 0.6H)8/air, shows the largest LIDT.

Journal Article↗

Prevalence of refractive error in Bangladeshi adults: results of the National Blindness and Low Vision Survey of Bangladesh.

PURPOSE: To determine the prevalence of refractive errors and to investigate factors associated with refractive error in adults 30 years of age and older in Bangladesh. DESIGN: Cross-sectional study. PARTICIPANTS: A nationally representative sample of 12 782 adults 30 years of age and older. METHODS: The sample of subjects was selected based on multistage, cluster random sampling with probability-proportional-to-size procedures. The examination protocol consisted of an interview that included measures of literacy, education, occupation, and refractive correction. Visual acuity testing (logarithm of the minimum angle of resolution [logMAR]), automated refraction, and optic disc examination were performed for all subjects. Subjects with <6/12 (0.3 logMAR) acuity in either eye were graded additionally for cataract and underwent a dilated fundal examination. Subjects for whom no refractive error was recorded (312 subjects; 2.7%) or who had undergone cataract surgery (123 subjects; 1.1%) were excluded from the analysis. MAIN OUTCOME MEASURES: Refractive error and socioeconomic variables (literacy, education, occupation). RESULTS: Eleven thousand six hundred twenty-four subjects were examined (90.9% response rate; mean age+/-standard deviation, 44+/-12.6 years). Five thousand four hundred eighty-nine subjects (49.1%) were men and 5700 subjects (50.9%) were women. Mean spherical equivalent was -0.19 diopters (D; +/-1.50 D). Six thousand four hundred twelve subjects (57.3%) were emmetropic, 2469 (22.1%) were myopic (<-0.5 D), and 2308 (20.6%) were hypermetropic (>+0.5 D). Two hundred six subjects (1.8%) were highly myopic (<-5 D). Myopia was more common in men (26.3%) than in women (21.0%), whereas hyperopia was more common in women (27.4%) than in men (15.8%). Overall, myopia increased with age (17.5% of those aged 30-39 years were myopic, compared with 65.5% of those age 70 years and older). A subanalysis of subjects without cataract showed increasing hyperopia with age and an association between myopia and higher education. Myopia was more common among the employed than in unemployed subjects. Astigmatism (>0.5 D), present in 3625 subjects (32.4%), was more common among women, illiterate subjects, and unschooled subjects. Against-the-rule astigmatism was more common (58.7%) than oblique astigmatism (29.3%), which was more common than with-the-rule (WTR) astigmatism (12.1%). Against-the-rule astigmatism and oblique astigmatism increased with age, unlike WTR astigmatism. Of 830 (7.5%) subjects, women were more commonly anisometropic (>1.0 D). Anisometropia increased with age. CONCLUSIONS: Refractive error data are described for a country and region that previously have lacked population-based data. Prevalence and factors associated with refractive error are presented, with a detailed comparison with other population-based surveys regionally and internationally.

Adult↗

New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography.

Optical coherence tomography (OCT) provides more parameters than pure morphology does. In a recent paper [A. Knuettel and M. Boehlau-Godau, J. Biomed. Opt. 5(1) 83-92 (2000)] we have shown that the refractive index (RI) can be evaluated in a localized manner in skin tissue under in vivo conditions. Based on a theory, originally developed for light detecting and ranging applications [L. Thrane et al., J. Opt. Soc. Am. A 17(3) 484-490 (2000)], the parameter mean scattering angle (MSA) could be derived in addition to RI. The effects of hydration on MSA and RI have been evaluated in vitro in pigskin and in vivo in human skin with our OCT scanner SkinDex 300. These parameters may have a viable impact in (cosmetic) skin research and clinical diagnoses. To the best of our knowledge, this is the first time that (multiple) scattering of light has been quantified through the observation of a new scattering parameter under in vivo conditions.

Adult↗

[Significance of optic formula selection for postoperative refraction after cataract operation].

BACKGROUND: Prediction of postoperative patient refraction is of paramount importance in modern cataract surgery. The choice of the IOL calculation formula plays a major role here. The influence of popular calculation formulas is evaluated in a prospective study. MATERIALS AND METHODS: We performed cataract surgery on 539 eyes with PC-IOL implantation in the capsular bag. The IOL power was computed using 10 different calculation formulas with the help of a personal computer. Patient refraction was examined two days and six months after surgery. RESULTS: The mean difference between desired and obtained refraction was -0.11 +/- 0.88 dpt 83% of all patients were in a +/- 1 D interval of desired refraction with a median visual acuity of 20/25. The formula used contributes a major part to the precision of calculation despite all problems due to errors of measurement. The theoretical formulas with variable "pseudophacic anterior chamber depth" are superior to the older ones. Standard deviation of the worst formula tested is 25% higher than that of the best one. With the best formula tested there would have been a good result (error < or = 1 D) in 82% of the cases, with the worst one in only 72%. CONCLUSIONS: The use of older formulas like SRK and Binkhorst should be discontinued and only the newer theoretical formulas (e.g. SRK/T, Holladay, Haigis etc.) be used. This is especially true for short and long eyes. For owners of a personal computer calculation and optimization of those more complex formulas should not be a problem.

Aged↗