PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “PULMONARY VALVE STENOSIS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

[Echocardiographic evaluation of pulmonary valve stenosis for valvuloplasty in children and adults].

OBJECTIVES: 1--To determine the accuracy of the echocardiographic selection and characterization of the pulmonary stenosis (PS) for balloon valvuloplasty; 2--To analyze the differences between children and adults in obtaining the echocardiographic parameters used for pulmonary stenosis characterization. MATERIAL AND METHODS: We studied 53 consecutive patients with PS and a peak Doppler gradient > or = 40 mmHg, submitted to cardiac catheterization to perform balloon valvuloplasty if the right ventricle to pulmonary artery peak-to-peak systolic pressure gradient was > or = 40 mmHg. The patients were divided into 3 groups on the basis of age: < or = 5 years (group 1; n = 18), 6-16 years (group 2; n = 17) and > 16 years (group 3; n = 18). A complete echocardiographic study was performed including identification of valvular morphology (commissural fusion, dysplasia or mixed), determination of right ventricle to pulmonary artery peak Doppler gradient and the transducer position that yielded the highest transvalvular flow velocity (V), evaluation of the right ventricular outflow tract morphology and measurement of the valvular annulus diameter. RESULTS: Technically adequate recordings were obtained in all patients. Fifty patients (94%) were submitted to pulmonary valvuloplasty. The echo-Doppler recording of V was obtained from the parasternal position in 27 patients (51%), suprasternal in 14 (26%), subcostal in 10 (19%) and apical in 2. In group 1, the V was obtained from the suprasternal position in 8 patients (44%), subcostal in 5 (28%), parasternal in 4 (22%) and apical in 1. In group 2, it was the parasternal position in 8 patients (47%), suprasternal in 6 (35%), subcostal in 2 (12%) and apical in 1. In group 3, it was the parasternal position in 15 patients (83%) and subcostal in 3. The peak Doppler gradient ranged from 40 to 215 mmHg (mean +/- SD = 78 +/- 37) and the peak-to-peak gradient at cardiac catheterization from 32 to 220 mmHg (mean +/- SD = 81 +/- 41). The correlation between eco-Doppler peak gradient and peak-to-peak gradient at cardiac catheterization was r = 0.95 (SEE = 12 mmHg) being, for group 1, r = 0.89 (SEE = 14 mmHg), for group 2, r = 0.97 (SEE = 8 mmHg) and, for group 3, r = 0.98 (SEE = 10 mmHg). The right ventricular outflow tract shows dynamic reaction 48 patients. Two patients had an infundibular gradient > 25 mmHg, significantly underestimated by echo-Doppler in one. All 5 patients (9%) but one with angiographic criteria for valvular dysplasia, were identified by echocardiography. One patient had a mixed form. The remaining 47 patients had valvular commissural fusion. The annulus size measured by echocardiography ranged from 10 to 28 mm (mean +/- SD = 17.7 +/- 4.3) and by angiography from 10 to 28 mm (mean +/- SD = 17.6 +/- 4.4). Close correlations were found between echocardiographic and angiographic measurements: r = 0.97 (SEE = 1.1 mm) being, for group 1, r = 0.90 (SEE = 1.1 mm), for group 2, r = 0.94 (SEE = 0.8 mm) and, for group 3, r = 0.87 (SEE = 1.3 mm). CONCLUSION: The echocardiographic examination allows an accurate selection and characterization of the PS for balloon valvuloplasty. The most significant difference in the study of PS in children and adults, was the lack in the ability of the eco-Doppler to record the V from the suprasternal position in adults. 2D echocardiography can reliably measure the annulus diameter in children and adults, providing precise information for balloon diameter selection before valvuloplasty.

Adolescent↗

[Treatment of congenital pulmonary valve stenosis by percutaneous valvuloplasty].

The purpose of this study was to evaluate the efficacy technique and follow-up results of balloon valvuloplasty for congenital valvular pulmonary stenosis. Percutaneous dilatation was performed in 48 patients aged 0.5 to 21 years (m = 7.5 yrs) from two pediatric cardiology centers (Lyon and Montreal). The right ventricular peak systolic pressure ranged from 42 to 180 mmHg (m = 93) before dilatation and fell from 24 to 105 mmHg (m = 48) immediately after dilatation. The pulmonary valvular peak systolic pressure gradient ranged from 22 to 156 mmHg (m = 73) and fell to 4 to 70 mmHg (m = 27) after the procedure (P less than 0.001). Follow-up continuous doppler data was available from 33 patients at 1 to 37 months (m = 9.2 months) after dilatation. The maximal instantaneous gradient from right ventricle pulmonary artery ranged from 0 to 74 mmHg (m = 27).

Adolescent↗