PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Penile Prosthesis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Does surgical approach affect the incidence of inflatable penile prosthesis infection?

OBJECTIVES: To review retrospectively the rate of infection in 380 consecutive organically impotent men implanted with a Mentor Alpha I inflatable penile prosthesis, stratified by surgical approach (scrotal or infrapubic). METHODS: Data were obtained from review of medical records. One hundred percent of cases were available for a minimum postoperative follow-up of 6 months. RESULTS: Twenty patients had a prior penile prosthetic operation and were excluded, leaving 360 primary implants for review. Overall, 6 patients (1.7%) developed periprosthetic infection. Four of these 6 patients were diabetic. Four of 139 infrapubic cases (2.9%) and 2 of 221 scrotal cases (0.9%) developed periprosthetic infection. This difference was not statistically significant (P = 0.15). Equal proportions of the infrapubic (39.6%) and scrotal cases (40.3%) were diabetic patients. The infection rate in patients with and without diabetes was 4 of 144 (2.8%) and 2 of 216 (0.9%), respectively. This difference was not statistically significant (P = 0.18). CONCLUSIONS: This study indicates that there is no statistically significant difference in the infection rate when the scrotal and infrapubic approaches to inflatable penile prosthesis insertion are compared.

Adult↗

Inflatable penile prosthesis: results of 150 cases.

OBJECTIVES: To evaluate the reliability of the prosthesis and the rate of complications in organically impotent men who were implanted with an inflatable penile prosthesis. PATIENTS AND METHODS: A consecutive series of 150 men (mean age 60 years, range 25-90) were followed for a mean of 19 months (range 0-65) after implantation of the Mentor Alpha 1 penile prosthesis. Information was obtained from their medical records and by telephone interview, but the satisfaction of the patients was not assessed quantitatively. RESULTS: There were no complications in 145 of the patients and they currently have functioning prostheses. Complications occurred in five patients (3%), including two peri-prosthetic infections (1%) and two intra-operative and one post-operative cylinder aneurysm. Complications requiring re-operation occurred in three (2%) of patients; none of the implants leaked. CONCLUSIONS: These results suggest that for men with organic impotence, a Mentor Alpha 1 implant is an effective treatment option with acceptable morbidity and good mechanical reliability.

Adult↗

Implantation of penile prosthesis in a patient with severe corporeal fibrosis induced by cavernosal injection therapy.

Implantation of a penile prosthesis in men with complicated fibrosis of corpus cavernosum is very difficult and even impossible. Cavernosal dilation requires sharp intracavernosal dissection to implant prosthesis, however complete removal of the fibrotic tissue is often impossible. We introduce a new technique using electric resection and electrovaporization of fibrotic tissue for implantation of penile prosthesis in a patient with severe corporeal fibrosis.

Fibrosis↗

Satisfaction with the malleable penile prosthesis among couples from the Middle East--is it different from that reported elsewhere?

No studies from the Middle East have investigated the psychosexual aspects of penile prosthesis. Therefore, several questions were used herein to address satisfaction with the use of malleable penile prosthesis among couples from this geographic area, as an option to treat erectile dysfunction (ED). A total of 50 patients who underwent the insertion of AMS 650 and Acu-form penile prostheses and their partners were evaluated with a retrospective clinical record review, as well as patient and partner questionnaires. In all, 70% of the patients and 57% of the partners were satisfied with the prosthesis. There was an increase in frequency of intercourse, sexual desire, and ability to achieve orgasm. Dislike for the device was the most common cause for nonsatisfaction of patients with the device, while sense of unnaturalness was that for partners. Results from this evaluation highlight the obvious need for proper preoperative counseling for both the patient and his partner to minimize unrealistic expectations. They also emphasize the importance of careful screening of both psychosocial and psychosexual aspects of the couple based on cultural ethnic background, since these are important predictors of the therapeutic outcome of prosthesis insertion. Efforts to extend information about ED to the public may be useful to reduce patients' exaggerated embarrassment about this problem and make their partners actively involved in the treatment.

Adolescent↗

Systemic absorption of gentamicin in penile prosthesis operations.

Irrigation with antibiotic solutions is frequently used in penile prosthesis surgery to avoid infection. We carried out a prospective study to determine the degree of absorption of gentamicin after intracavernous irrigation in 10 patients who underwent penile implantation surgery. All obtained values were below the toxic level of 10 micrograms/ml and decreased gradually within a few hours. We concluded that highly concentrated gentamicin solutions could be used with safety for intracavernous irrigation.

Absorption↗

Report of a multicenter clinical evaluation of the Dura-II penile prosthesis.

PURPOSE: Information was collected during the first 2 years of an ongoing, prospective, multi-institutional evaluation of the Dura-II penile prosthesis. Evaluation included data on clinical outcomes and a patient satisfaction survey, and will continue for 5 years after implantation for each patient. MATERIALS AND METHODS: To date 196 patients have been evaluated. Surgical data, adverse events and information from satisfaction surveys are reported. RESULTS: At a followup of 13.4 +/- 8.4 months postoperatively, adverse events occurred in 8.2% of the patients, resulting in reoperation in 5.1%. There have been no mechanical failures. Overall satisfaction rates were 85% at 3 months, 83% at 1 year and 91% at 2 years after implantation, and levels of sexual functioning were correspondingly high. A majority of patients assigned high scores to rigidity, concealability, ability to have intercourse and erection size, although satisfaction with erection size ranked lower than the other measures. CONCLUSIONS: The Dura-II penile prosthesis provides a satisfactory result and has an acceptable level of complications associated with its use. Further followup will assess temporal changes in satisfaction rates and sexual functioning for these patients.

Adult↗

Utility of magnetic resonance imaging in evaluating inflatable penile prosthesis malfunction and complaints.

The introduction of oral pharmacotherapy dramatically changed practice patterns in erectile dysfunction. The direct effect was to decrease the numbers of patients seeking penile implants; an indirect effect has been the changing ratio of new, to re-do operations. Patients seeking replacement inflatable penile prosthesis (IPP) surgery pose challenges both in diagnosis and management; in very select cases preoperative MRI can be useful in the evaluation of the patient's complaint and in planning operative management. Imaging can supplement the physical exam; in certain cases imaging will reveal: crural herniation, corporal distortion, corporal fibrosis, and hardware migration. Inflatable penile prosthesis has a high rate of satisfaction for patients (89%) and partners (70%). The principal reasons for dissatisfaction are penile shortening, pain and frustration with reoperation. If pain is not due to infection, it may be secondary to malpositioning, improper sizing, cylinder cross-overs, or herniation. After one or more reoperations, penile distortion may occur secondary to tunica albugenia thinning or fibrosis. A series of cases will be presented to highlight the utility of MRI for IPP problems, define normal appearance and abnormal appearance of penile hardware. Careful collaboration between the Urologist and Radiologist in the review and final dictation of these cases is warranted to properly document problems and to plan device replacement/penile reconstruction.

Aged↗

Cavernous tissue antibiotic levels in penile prosthesis surgery.

A comparison of the delivery of several antibiotics (vancomycin, gentamicin and aztreonam) to the tissue site of prosthesis implantation was studied using cavernous tissue levels for each antibiotic. A total of 32 patients underwent penile prosthesis implantation. Intravenous antibiotics were administered 1 to 2 hours preoperatively, with vancomycin and aztreonam given to patients at the Tulane University Medical Center, and vancomycin and gentamicin given to patients at the New Orleans Veterans Administration Hospital. At operation the urine, serum and cavernous tissue were concurrently sampled and later analyzed for antibiotic concentration. The mean cavernous tissue level for vancomycin was 55.5 +/- 5.5 ng./mg. (standard deviation) for 20 patients, while the mean cavernous tissue levels for aztreonam and gentamicin were 8.9 +/- 2.1 ng./mg. for 10 patients and 4.7 +/- 1.2 ng./mg. for 12 patients, respectively. When the delivery of antibiotic to cavernous tissue was compared (quantitated as ng. antibiotic per mg. tissue per mg. drug administered), a statistically significant value (p less than 0.01) was observed with vancomycin (0.11 ng./mg./mg.) greater than gentamicin (0.06 ng./mg./mg.) or aztreonam (0.01 ng./mg./mg.), and with no significant difference observed between aztreonam or gentamicin. These findings suggest that cavernous tissue levels may be used as a method to determine optimal antibiotic prophylaxis against penile prosthesis infection.

Aztreonam↗

Clinical experience with Scott inflatable penile prosthesis in 150 patients.

The Scott inflatable penile prosthesis was implanted in 150 patients with organic (89%) and psychologic (11%) impotency from 1979 to 1982. The patients were followed up for an average of twenty-five (6-46) months. A satisfactory result was achieved in 133 (89%) patients. Forty-nine major complications occurred in 38 patients. Forty-four surgical procedures were performed in 33 patients to correct mechanical or technical complications (32), replace the device (9), or remove the device (3). Two patients refused corrective surgery, and the complications could not be corrected in 2 patients. Cylinder leaks (15), leaks at tubing/connector junctions (14), and cylinder aneurysms (7) were responsible for most of the mechanical failures. Additional refinements in surgical technique will not eliminate these problems. Device modifications should be made to increase cylinder durability, to eliminate the need for suture ligation of tubing/connector junctions, and to assure symmetrical cylinder expansion.

Adult↗

AMS malleable penile prosthesis.

The American Medical Systems (AMS) malleable penile prosthesis was implanted in 57 patients from January, 1983 to 1985. Fifty-one per cent of the procedures were performed under local anesthesia, and 28 per cent in ambulatory (day) surgery. The prosthesis was evaluated in terms of cosmetic result, patient satisfaction and function, and postoperative complications. Ninety-one per cent of patients were satisfied with their decision to select the malleable prosthesis, and 66 per cent reported no difficulty with concealment. A comparison is made with data available from the alternative Jonas malleable prosthesis.

Adult↗

Clinical experience with the Mentor inflatable penile prosthesis in 301 patients.

The Mentor inflatable penile prosthesis has been implanted in 301 patients during the last 60 months, of whom 3 died of unrelated causes and 13 have been lost to followup. Of the remaining 285 patients 96.8 per cent are presently using the device. A life table analysis of 253 implantations performed since 1983 shows that 97 per cent of the prostheses presently being implanted will survive 48 months without mechanical failure. There have been no wear-induced leaks or aneurysms in the 602 cylinders implanted. Complications that resulted in permanent device loss or necessitated a second operation were owing to mechanical problems in 3 per cent, infection in 2.3 per cent and surgeon error in 1.7 per cent of the cases. This clinical study demonstrates the 5-year reliability of cylinders constructed from polyurethane, the reliability of the Mentor snap-on connector system and the increased durability of nylon-reinforced silicone tubing.

Consumer Behavior↗

[Penile prosthesis in case of impotence: 12 years of clinical experience].

Among 95 patients who have received a penile prosthesis between 1982 and 1993 (mean follow up of 46 months), 21 (22%) presented complications requiring one or more reintervention(s). Only for two patients the problem was mechanical, in the majority, they were non mechanical. Five of those subjects (5.5%) presented such complications that definitive explanation of the device was necessary. The problems presented by the 9 remaining patients were fully satisfactorily managed. Presently 94.5 per cent of the patients are using the device. Follow-up study of our interdisciplinary group demonstrates the efficacity of the prosthesis for revitalisation of the couples. The definitive parameters of implantation acceptance are essentially the partner influence and the treatment cost. This clinical study shows that the implantation of a penile prosthesis is an effective therapy in the treatment of impotence in a selected population. Presently, the mechanical reliability of different device has been good to date.

Adult↗

A new treatment for Peyronie's disease: modeling the penis over an inflatable penile prosthesis.

We treated 138 patients with severe Peyronie's disease by insertion of an inflatable penile prosthesis and manual modeling of the erect penis. This novel technique was successful in 118 patients (86%) in achieving a straight, rigid erection. In 11 patients (8%) penile modeling did not result in satisfactory straightening and relaxing plaque incisions were performed. Complications of penile modeling included urethral perforation in 4 patients (3%). Infection of the prosthesis occurred postoperatively in 4 patients (3%). At a mean followup of 32 months (range 9 to 84) 124 patients (90%) were actually using the penile prostheses and none reported penile shortening or impairment of glandular sensation. We suggest that penile modeling over an inflatable penile prosthesis is an important new technique for the patient with severe Peyronie's disease.

Adult↗

Assessment of psychosexual adjustment after insertion of inflatable penile prosthesis.

OBJECTIVES: To evaluate the psychosexual benefit obtained from multicomponent penile implant surgery in patients with erectile dysfunction. METHODS: A psychosexual questionnaire was given to 35 patients undergoing penile prosthesis implantation before surgery and at 3 months, 6 months, and 1 year after surgery. The questionnaire consisted of 13 questions scored on a scale from 1 through 5. Results of the questionnaire were statistically analyzed for differences among the preoperative, 3-month postoperative, 6-month postoperative, and 1-year postoperative period. RESULTS: The general linear model evaluation showed a significant difference for each overall combination of the following pairs: preoperative versus 3 months postoperative (P=0.0005) and 3 months postoperative versus 6 months postoperative (P=0.002). There was no overall difference between psychosexual total score at 6 months after surgery and 1 year after prosthesis implantation (P=0.85). The patients perceived improvement in their erectile ability and libido. Concern about obtaining and maintaining an erection during intercourse was significantly alleviated. There was an increase in the frequency of sexual activity and an improvement in satisfaction with sex life. A decrease in feelings of sadness, depression, anxiety, anger, frustration, and embarrassment related to sexual activity was also noted. CONCLUSIONS: The current study demonstrates significant improvement in the psychosexual well being of multicomponent penile implant recipients, with attainment of a high level of patient satisfaction up to 1 year after surgery.

Adaptation, Psychological↗

Duraphase penile prosthesis--results of clinical trials in 63 patients.

The Duraphase penile prosthesis was implanted in 63 patients at 4 investigative sites during clinical trials. This device is a semirigid rod that is bendable and provides good support to the erection. Mechanical complications included 4 instances of cable breakage rendering the device nonfunctional. Of 57 patients questioned 55 were pleased with the results after 4 months. Ease of insertion and exceptional bendability are other features that make this device attractive.

Adult↗

Long-term mechanical reliability of multicomponent inflatable penile prosthesis: comparison of device survival.

OBJECTIVES: To determine the mechanical reliability of multicomponent inflatable penile prosthesis, comparing five different types of devices, as well as the two-piece versus three-piece as a group. METHODS: We followed 83 patients with two-piece and 283 patients with three-piece inflatable penile prostheses for a mean time of 66 months. At a cutoff of 63 months, mechanical complication rates were reviewed and statistically analyzed. RESULTS: Thirty-one device-related complications occurred, and all were secondary to fluid leakage. The Mentor Alpha-1 prosthesis was significantly better than the Mentor Mark-II in terms of mechanical reliability (P = 0.01). A trend was noted toward the AMS 700 Ultrex inflatable penile prosthesis having fewer mechanical complications than the Mentor Mark-II (P = 0.06). In addition, a trend toward all three-piece prostheses being more mechanically reliable than the two-piece was noted (P = 0.08). The Mentor Alpha-1 device had a higher cumulative proportional survival (0.957) than all other devices (0.842 for AMS 700 Ultrex, 0.839 for AMS 700 CX, 0.783 for Mentor GFS, and 0.750 for Mentor Mark-II). CONCLUSIONS: As a group, a trend was noted toward the three-piece prosthesis having better mechanical reliability than the two-piece prosthesis. Comparisons between the individual types of prostheses showed thatthe Mentor Alpha-1 device was significantly more mechanically reliable than the Mentor Mark-II device, and a trend was noted toward the AMS 700 Ultrex device having fewer mechanical complications than the Mentor Mark-II. The Mentor Alpha-1 prosthesis had the highest cumulative proportional survival.

Adult↗

Ventral penile approach in unitary component penile prosthesis placement.

We report the results of a series of 79 patients who underwent placement of a unitary component penile prosthesis via a ventral penile skin incision in conjunction with distal ventral corporotomies. This approach facilitates the placement of semirigid and inflatable devices, and eliminates potential pitfalls of other incisions by limiting corporotomy length, avoiding dissection around neurovascular structures and allowing a multilayered closure with nonoverlapping suture lines.

Anesthesia↗