Maintenance requirements of implant-supported fixed prostheses opposed by implant-supported fixed prostheses, natural teeth, or complete dentures: a 5-year retrospective study.

PURPOSE: The purpose of this study was to compare the maintenance requirements of implant-supported fixed prostheses with cantilever arms in edentulous jaws when opposed by fixed prostheses of similar design, by natural teeth, or by complete dentures. MATERIALS AND METHODS: The maintenance requirements for the 5-year follow-up period were obtained by examining the dental records of 37 people. Six were provided with fixed prostheses in both arches, 22 with a fixed prosthesis in the mandible opposed by a complete denture, and 9 with a fixed prosthesis opposed by natural teeth. Everyone was treated with Nobel Biocare implants using standard implant and prosthetic protocols. RESULTS: The denture teeth and acrylic resin were repaired on 44 occasions in the group with implants in both jaws, on 14 occasions in the group with implants opposed by natural teeth, and twice in the group in which the implants were opposed by a complete denture. The group with implants in both jaws was more likely to fracture the gold-alloy framework, which occurred on six occasions. The group with implants in both jaws was significantly different from the other two groups in relation to higher incidence of fracture of the teeth and gold-alloy framework. CONCLUSION: The maintenance requirements of implant-supported fixed prostheses with cantilever arms opposed by fixed prostheses of similar design were much greater than when opposed by natural teeth or complete dentures.

Acrylic Resins↗

A within-subject comparison of mandibular long-bar and hybrid implant-supported prostheses: psychometric evaluation and patient preference.

Although it has been shown that patients are more satisfied with prostheses supported by implants than with conventional dentures, there have been few direct comparisons of the various designs of implant-supported prostheses. This within-subject crossover clinical trial was designed to compare two forms of removable prostheses which are frequently prescribed for the edentulous mandible: a long-bar overdenture supported by 4 implants and a two-implant hybrid overdenture. Sixteen completely edentulous subjects were given a new maxillary conventional denture: Ten of them received the mandibular long-bar prosthesis first and six the hybrid. After a two-month adaptation period, psychometric measures of various aspects of the prostheses and physiological tests of masticatory efficiency were carried out over three weeks. The mandibular prostheses were then changed and the procedures repeated. At the end of the study, subjects were asked to choose the mandibular prosthesis that they wished to keep, and final psychometric measures were taken. In this paper, the results of the psychometric assessment and patient preference are presented. Subjects assessed factors such as general satisfaction, quality of life, stability, retention, comfort, esthetics, ease of cleaning, speaking, and chewing, and how well-chewed foods were before being swallowed. Most of the factors except ease of cleaning and speaking were rated significantly better with long-bar overdentures than with hybrid ones. These results are consistent with the fact that all subjects chose long-bar overdentures, reporting stability, ease of chewing, and comfort as the most important factors influencing their choice. These results suggest that, although subjects assign high ratings for most factors to hybrid overdentures, they find long-bar overdentures to be significantly more stable, comfortable, and easier for chewing.

Adult↗

Neuromuscular coordination of masticatory muscles in subjects with two types of implant-supported prostheses.

OBJECTIVES: To compare the electromyographic (EMG) characteristics of masticatory muscles in patients with fixed implant-supported prostheses and implant overdentures. MATERIAL AND METHODS: Nineteen subjects aged 45-79 years were examined. Fourteen were edentulous and had been successfully rehabilitated with (a) maxillary and mandibular implant-supported fixed prostheses (seven patients); (b) mandibular implant overdentures and maxillary complete dentures (seven patients). Five control subjects had natural dentition or single/partial (no more than two teeth) tooth or implant fixed dentures. Surface EMG of the masseter and temporal muscles was performed during unilateral gum chewing and during maximum teeth clenching. To reduce biological and instrumental noise, all values were standardized as percentage of a maximum clenching on cotton rolls. RESULTS: During clenching, temporal muscle symmetry was larger in control subjects and fixed implant-supported prosthesis patients than in overdenture patients (analysis of variance, P=0.005). No differences were found in masseter muscle symmetry or in muscular torque. Muscle activities (integrated areas of the EMG potentials over time) were significantly larger in control subjects than in implant-supported prosthesis patients (P=0.014). In both patient groups, a poor neuromuscular coordination during chewing, with altered muscular patterns, and a smaller left-right symmetry than in control subjects were found (P=0.05). No differences in masticatory frequency were found. CONCLUSION: Surface EMG analysis of clenching and chewing showed that fixed implant-supported prostheses and implant overdentures were functionally equivalent. Neuromuscular coordination during chewing was inferior to that found in subjects with natural dentition.

Adaptation, Physiological↗

Treatment outcomes of fixed or removable implant-supported prostheses in the edentulous maxilla. Part II: clinical findings.

STATEMENT OF PROBLEM: There is a widespread belief that maxillary overdenture prostheses are associated with a higher frequency of complications and require more maintenance than fixed implant prostheses. PURPOSE: This prospective clinical study compared the treatment outcomes of fixed and removable implant-supported restorations in the edentulous maxilla with the main emphasis on the clinician's point of view. MATERIAL AND METHODS: Ten patients were treated with fixed screw-retained implant prostheses (group 1), and 10 patients were treated with removable implant-supported overdentures (group 2) in the edentulous maxilla. Recall was scheduled at 6-month intervals to investigate the prosthodontic treatment outcomes, including implant survival, prosthesis time until retreatment, and maintenance issues. Clinical parameters gingival index (GI), plaque index (PI), the clinical attachment level, and radiographic marginal bone levels measured, along with any biologic and mechanical complications were recorded. RESULTS: Patients were followed over a mean period of 39 months (SD=7; group 1) and 27 months (SD=10; group 2) after implant placement. Cumulative implant survival was 97.6% for group 1 and 94.4% for group 2 after an 18-month observation period. The mean time until retreatment after prostheses insertion was 23.4 months for group 1 and 19.8 months for group 2 (n.s.). In both groups, the increase over time in the radiographically investigated bone level was found to be significant. The indices given for the mucosal health and oral hygiene status (GI and PI) were highly correlated in both groups at each recall appointment, but no significant differences were found between groups 1 and 2. CONCLUSION: In groups 1 and 2, comparable prosthodontic treatment outcomes were achieved. The majority of mechanical complications could be managed chairside during recall visits and did not require additional appointments, so that the time and costs involved in providing maintenance were kept down.

Alveolar Process↗

[Application of implantable electronic prostheses for patients with hearing impairment].

Introduction of implantable electronic prostheses to the clinical practice has created new possibilities of hearing and language communication improvement. Currently implants of various types are used as prostheses implanted in the external ear, temporal bone, middle ear, inner ear and brain stem. Applying appropriate acoustic and electric stimulation they allow us to effectively improve auditory abilities and introduce born deaf patient to the world of sounds or bring back to the world postlingually deafened patient.

Cochlear Implantation↗

Fixed implant-supported prostheses in elderly patients: a 5-year retrospective study of 133 edentulous patients older than 79 years.

BACKGROUND: An increasing number of elderly patients are treated with implants, but results for the elderly patient in terms of implant success and adaptation to implant prostheses are contradictory. OBJECTIVE: To retrospectively study the 5-year clinical and radiologic performances of fixed implant-supported prostheses placed in edentulous elderly patients and to compare those results with the results of using similar prostheses in a control group of younger patients. MATERIALS AND METHODS: The study group comprised 133 edentulous patients who were 80 or more years of age and who were consecutively treated with fixed implant-supported prostheses between January 1986 and August 1998. Altogether 761 Brånemark System implants (Nobel Biocare AB, Göteborg, Sweden) were placed in 139 edentulous jaws. The control group comprised 115 edentulous patients who were younger than 80 years and who were treated consecutively from March 1996 to November 1997 with similar prostheses. In this group 670 implants were placed in 118 edentulous jaws. Information was collected from all postinsertion visits, including the fifth annual checkup, and changes of marginal bone levels were analyzed from intraoral radiographs. RESULTS: The 5-year cumulative survival rate (CSR) for implants in the maxilla was 93.0% in the study group and 92.6% in the control group; the corresponding CSRs for implants in the mandible were 99.5% and 99.7%. The most common complications for patients in the study group were soft tissue inflammation (mucositis) and cheek and lip biting (p < .05) whereas resin veneer fractures were the most common complications for the control group. Overall 5-year marginal bone loss for the study group was 0.7 mm (standard deviation [SD], 0.45) in the upper jaw and 0.6 mm (SD, 0.50) in the lower jaw. Differences in bone levels and bone loss between the two groups did not reach significant levels (p > .05). CONCLUSIONS: Implant treatment in the elderly patients showed treatment results comparable to those observed in younger age groups. However, indications of more problems with adaptation could be observed and were reflected in more postinsertion problems. Cleaning problems and associated soft tissue inflammation (mucositis) as well as tongue, lip, and cheek biting were significantly more often observed among the elderly patients (p < .05).

Adaptation, Physiological↗

An impression and cast construction technique for implant-retained auricular prostheses.

Implant-retained auricular prostheses present a challenge with regard to the esthetic placement of the margins of the prosthesis. A technique for the impression and master cast fabrication to produce an implant-retained auricular prosthesis is described. This technique allows control of the esthetic margin, fabrication of a durable master cast with planned blockout, and inclusion of a replica of the retentive bar, which allows processing duplicate prostheses without returning the retentive bar to the mold.

Ear, External↗

Effect of cantilever length on stress transfer by implant-supported prostheses.

Cantilever lengths for fixed implant supported prostheses have been based largely on empirical judgment. This study determined the effects of cantilever length on load transfer to the mandible. A photoelastic model of a moderately resorbed edentulous human mandible with five 13 mm Bränemark implants was constructed. Simulated occlusal loads at varying cantilever lengths were applied to the occlusal surface of a routinely fabricated fixed prosthesis. The highest stresses were located at the ridge crest on the distal surface of the distal implant for all cantilever lengths. Apical stresses at this implant developed in reciprocation to the effect of the distal tipping force on the cantilever. Curves describing the effect of cantilever length on maximal stress are presented. Little load transfer to adjacent implants was found. Disproportionate increases in maximum stress with increasing cantilever length occurred. Minor variations in implant angulation had a distinct effect on stress magnitude.

Dental Implantation, Endosseous↗

Neurophysiological requirements for implanted cochlear prostheses.

Regarding the neurophysiological requirements for implanted cochlear prostheses, we have discussed (i) the complexity of speech sounds, (ii) problems of intensity, then (iii) the frequency problem, and (iv) finally the possibility of a frequency transposition to the genuine frequency range of a single fibre of any mechanoreceptor and its connecting nerve fibre (less than 1 kHz) for the construction of an intracochlear prosthesis. In general it would seem necessary to seek compromises based on the fact that speech, at least the vowels, contains redundancy and that the use of additional sensory channels might be helpful for cochlear implants. Certainly besides other preprocessing techniques for speech information, the multichannel stimulation set-up of special electrodes has to be used to convey a sufficient amount of speech information to restore the faculty of speech perception in completely deaf patients. Decompression of intensity range and compression of frequency range might be especially useful.

Acoustic Stimulation↗

[Dysfunction of valvular prostheses].

Implantation of artificial mechanic valvular prostheses significantly improves and prolong the life of patients with valvular defects with a haemodynamic impact. This therapeutic method does not cure the patients and operation switches the problem of a natural dysfunctional valve to that of a functional artificial valve with improvement of the quality of life and its prolongation. The long-term effect and thus the general prognosis--the patient's "fate" depends above all on complications such as infections and haemocoagulation which are the main cause of dysfunction of artificial prostheses. The authors describe in the submitted paper basic principles of prevention of these undesirable events and decisive steps which must be taken to ensure a rapid and accurate diagnosis of imminent of already developed dysfunction of the prosthesis and its solution under the given conditions.

Heart Valve Prosthesis↗

A retrospective study on the maintenance and repair of implant-supported prostheses.

This study reviewed the prosthodontic treatment and aftercare required by 29 patients with 32 implant-supported prostheses (12 fixed and 20 removable) placed on 107 implants. Patients were followed for 4 to 39 months. The majority of implant-supported prostheses (53%) were placed in the mandible. Visual analogue scales were used by the patients to rate their satisfaction with their prostheses and their chewing ability. Approximately one third of the patients studied required three or more relines of their existing dentures between first- and second-stage surgeries, while over half of the definitive implant-supported prostheses required a major adjustment or repair. Removable prostheses required 78% of the total repairs and accounted for 80% of those prostheses that needed repeated repairs. In general, patients were very satisfied with their implant-supported prostheses, but 17% complained of mild speech difficulties and 7% noted slight difficulty in cleaning their fixed prostheses. Overall, the short-term prosthetic management required for the implant-supported prostheses in this study was substantial, particularly with the removable prostheses, and this should be taken into account when evaluating prosthetic options.

Dental Clasps↗

[General principles of planning fixed prostheses on implants].

The planning of fixed prostheses comprising also implant abutment is determined by that, as regards loadability, none of the implant kinds can be considered as first rate abutment tooth. At planning bridges the procedure according to the prosthetic principles related to weaker or damaged periodontium teeth is employed.

Dental Abutments↗

[Late reactions following implantation of silicone prostheses].

Silicone implants can provoke local reactions (granulomas, lymphadenopathy) and also systemic side-effects. About 80 case reports in the literature describe autoimmune disease following silicone augmentation. The clinical spectrum includes signs and symptoms of progressive sclerosis, mixed connective tissue disease and lupus erythematosus. We present 4 cases with possible autoimmune phenomena related to breast augmentation. After explantation in 1 case the clinical and immunological features disappeared, and the antinuclear antibodies subsequently decreased from a titre of 1:1280 (speckled form) to 1:160 (homogeneous form). To our knowledge there are no similar reports on systemic complications following the use of silicone in urology.

Adult↗

New ways of designing suprastructures for fixed implant-supported prostheses.

The replacement of lost teeth and tooth-bearing tissues with implant-supported prostheses often forced both dentist and technician to choose removable overdentures because they were the only treatment modality possible. By means of a clinical case, this article demonstrates a new approach in framework design that not only expands the limitations of conventional ceramometal implant prostheses, but also eliminates a great number of the hazards that cause implant failure with a new type of suprastructure. The technique enables both the clinician and the technician to apply all of the esthetic possibilities of tooth-supported metal ceramic crown and bridge techniques. This technique combines screw and cementation retention without changing the original treatment protocol. A new casting technique introduced by Sonntag and a new specially developed alloy was used. Essentially, the reconstructive body has been broken down into a screw-retained soft tissue/bone-replacing part using a one-piece casting technique, and a crown-replacing part to be provisionally cemented with a large variety of new possibilities.

Aged↗

An image processing technique for the identification of contact pixels applied to x-ray CT images of implanted hip prostheses.

Uncemented prosthetic joint implants used in orthopaedic surgery are usually coated with a porous surface to encourage bone ingrowth. Better contact between the endosteal bone and the porous surface improves ingrowth, and such contact may be increased if the joint further subsides into position in the first weeks following implantation. An image processing technique has been developed as part of a study undertaken to determine the effect of early subsidence on endosteal contact. The method provides a measure of the degree of contact between the surfaces from transverse x-ray CT images, but is suitable for application to any image with a similar intensity distribution.

Hip Prosthesis↗

Intrusion and reversal of a free-standing natural tooth bounded by two implant-supported prostheses: a clinical report.

Although intrusion of natural tooth abutments in tooth-implant connected fixed prostheses has been reported, it can also occur to a free-standing natural tooth bounded by implant prostheses. For the patient described in this article, intrusion was noted with a natural tooth bounded by 2 implant-supported prostheses 5 months after insertion of the prostheses. The intrusion was reversed completely after 5 months with appropriate management. The course of treatment and possible mechanisms of intrusion are provided.

Bicuspid↗