PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Sample pretreatment”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Piezoelectric immunochip for the detection of dengue fever in viremia phase.

The global prevalence of dengue fever has grown so dramatically in recent years that it is endemic in more than 100 countries and has become a major international public health concern. Moreover, since the flu-like symptoms that accompany dengue fever are atypical and varied, the detection procedures currently used to identify it are cumbersome and time-consuming, making early stage epidemiological control and effective medical treatment of this epidemic almost impossible. In this study, a QCM-based detection system was developed in which two monoclonal antibodies against dengue E and NS-1 protein, respectively, were control orientated immobilized on QCM via protein A to produce an immunochip. Various sample pretreatment procedures were evaluated to ascertain the most suitable combination, and both the simulating samples and the clinical specimen were examined by the immunochip. The results revealed that the cibacron blue 3GA gel-heat denature (CB-HD) method was the most effective sample pretreatment technique. Due to the complex composition of the serum, the immunochip could only effectively quantify dengue viral antigens in a 1/1000 untreated simulated sample. With the help of the CB-HD method, the dilution folds were found to capable of being reduced from 1000 to 100, and the detection limit lowered to 1.727 microg/ml (E protein) and 0.740 microg/ml (NS-1 protein) in the original sample. While the cocktail immunochip could not quantify both antigens separately, the higher signal level rendered it a more effective qualification tool for suspect screening. Moreover, the results of the analysis of clinical specimens also proved the ability and future potential of cocktail immunochip in discriminating dengue-positive cases from negative serum specimens in the viremia phase.

Adolescent↗

Concentrations of hazardous heavy metals in environmental samples collected in Xiamen, China, as determined by vapor generation non-dispersive atomic fluorescence spectrometry.

Non-dispersive atomic fluorescence spectrometry (NDAFS) coupled with vapor generation (VG) sample introduction was applied to the determination of the concentrations of hazardous heavy metals, such as arsenic, cadmium, lead and mercury, in seawater, soils and total airborne particulate matter (PM) collected around the Xiamen area in China. Almost 100% sample introduction efficiency was achieved by using thiourea and ascorbic acid for the pre-reduction of As(V) to As(III), K3Fe(CN)6 and tartaric acid for pre-oxidation of Pb(II) to Pb(IV), and masking the interferences arising from the co-existing transition metals to As, Cd, Hg and Pb during their vapor generation process. Moreover, a novel sample pretreatment device was developed to avoid the loss of mercury, lead, cadmium and arsenic during sample pretreatment. With such methods, the detection limit (DL) of arsenic, cadmium, lead and mercury was down to 0.08, 0.03, 0.05, 0.01 ng mL(-1) (3sigma), respectively. The relative standard deviations (RSD, n = 11) for arsenic, cadmium, lead and mercury at 10 ng mL(-1) were 0.9%, 1.6%, 1.3% and 2.0%, respectively. The concentrations of hazardous heavy metals in the environmental samples collected in Xiamen, China are in the range from 0.02 +/- 0.001 ng mL(-1) in seawater to 15.3 +/- 0.2 microg g(-1) in soils. Besides flame/GF-AAS and ICP-AES/MS, VG-NDAFS should be another choice for the determination of hazardous heavy metals in environmental samples.

China↗

Prerequisites for the on-line control of microbial processes by flow injection analysis.

Problems associated with the use of biosensors in process control, e.g. difficulties of sterilization and sensor fouling, are shortly displayed, and possibilities to overcome them are outlined. The advantages of flow injection analysis (FIA) are demonstrated and examples for efficient sampling systems connected with this method are reviewed. Special emphasis is given to problem-orientated sample pretreatments, preventing fast inactivation of immobilized enzymes in the analysis system. Examples of problem-orientated sample pretreatment units are given. A proposal for a computer-controlled self-calibrating FIA system is given.

Bacteria↗

Determination of food colorants by microemulsion electrokinetic chromatography.

A microemulsion electrokinetic chromatography (MEEKC) method was developed to analyze and detect eight food colorants (tartrazine, fast green FCF, brilliant blue FCF, allura red AC, indigo carmine, sunset yellow FCF, new coccine, and carminic acid), which are commonly used as food additives in various food products. The effects of sodium dodecyl sulfate (SDS) surfactant, organic modifier, cosurfactant, and oil were examined in order to optimize the separation. The amount of organic modifier (acetonitrile) and SDS surfactant were determined as apparent influences on the separation resolution while the type of oil and cosurfactant rarely affected the separation selectivity of the eight colorants. A highly efficient MEEKC separation method, where the eight colorants were separated with baseline resolution within 14 min, was achieved by using a microemulsion solution of pH 2.0 containing 3.31% SDS, 0.81% octane, 6.61% 1-butanol, and 10% acetonitrile. This optimal MEEKC method has a higher separation efficiency and similar detection limit when compared to conventional capillary electrophoresis (CE) method. Furthermore, a sample pretreatment is rarely needed when this MEEKC technique is used to analyze colorants in food products, whereas a suitable sample pretreatment (for example solid-phase extraction) has to be employed prior to CE separation in order to eliminate matrix interferences resulting from the constituents of the food sample.

Acetonitriles↗

Evaluation of micronuclei frequency in the cultured peripheral blood lymphocytes of cancer patients before and after radiation treatment.

The frequency of micronucleated binucleate lymphocyte (MNBNC) was determined in the peripheral blood lymphocytes of patients suffering from various types of cancer before the onset of radiation treatment, middle (mid-) of the treatment and after completion of the treatment (post-treatment). The frequency of micronuclei increased significantly in the pretreatment sample of cancer patients when compared with the normal untreated healthy volunteers. During the middle of the radiotherapy an approximate two or > two-fold increase was observed in the micronuclei frequency in most of the patients when compared with the concurrent pretreatment samples. Immediately after the completion of treatment, the frequency of micronuclei further increased, and this increase was significantly higher than that of pretreatment and mid-treatment samples. Out of 27 patients analyzed, only nine patients did not have any history of smoking, tobacco chewing or alcohol consumption, while the remaining 18 patients had a history of either smoking, tobacco chewing or alcohol consumption or combination of two or all habits at the time of blood collection.

Adult↗

A disposable amperometric sensor screen printed on a nitrocellulose strip: a glucose biosensor employing lead oxide as an interference-removing agent.

A new type of disposable amperometric sensor is devised by screen printing thick-film electrodes directly on a porous nitrocellulose (NC) strip. The chromatographic NC strip is then utilized to introduce various sample pretreatment layers. As a preliminary application, a glucose biosensor based on hydrogen peroxide detection is constructed by immobilizing glucose oxidase (GOx) on the NC electrode strip and by formulating a strong oxidation layer (i.e., PbO2) at the sample loading area, placed below the GOx reaction band. The screen-printed PbO2 paste serves as a sample pretreatment layer that removes interference by its strong oxidizing ability. Samples applied are carried chromatographically, via the PbO2 paste, to the GOx layer, and glucose is catalyzed to liberate hydrogen peroxide, which is then detected at the electrode surface. The proposed NC/PbO2 strip sensor is shown to be virtually insusceptible to interfering species such as acetaminophen and ascorbic and uric acids and to exhibit good performance, in terms of the sensor-to-sensor reproducibility (standard deviation, +/-0.026 - +/-0.086 microA), the sensitivity (slope, -0.183 microA/mM), and the linearity (correlation coefficient, 0.994 in the range of 0-10 mM).

Biosensing Techniques↗

Selective fluorogenic derivatization of a peptide nucleic acid trimer with naphthalene-2,3-dicarboxaldehyde.

The reversed-phase high-performance liquid chromatography of a Peptide Nucleic Acid (PNA) trimer has been studied after its preseparation fluorogenic derivatization with naphthalene-2,3-dicarboxaldehyde in the presence of cyanide (NDA/CN). Trace levels of the PNA trimer were determined in cell homogenate samples containing the PNA trimer at prederivatization concentrations as low as 48.9 ng ml-1. The sample pretreatment operations included a deproteination step, achieved by ultra-filtration, followed by fluorogenic derivatization (NDA/CN). Subsequently, to achieve adequate selectivity, the fluorescently labeled PNA was subjected to high performance anion exchange chromatography prior to quantitation via fluorescence detection. The various problems encountered during sample pretreatment and separation of derivatized PNA trimer in biological samples are presented and discussed.

Caco-2 Cells↗

[Microbiological assay method of BMY-28100 and some other cephem antibiotic in serum and tissues. Development of new sample preparation with Evan's blue, a high albumin binding dye].

With a new simple sample pretreatment, microbiological assay methods for quantitative determination of BMY-28100 and some other cephem antibiotics in serum and tissues have been developed. Presented sample pretreatment was founded on the extraction with Evans' blue, a high serum protein binding dye, and the ultrafiltration using cellulose membrane (Millipore; MW cutoff is 10,000) to which Evans' blue was specifically absorbed. Regardless of sample media, antibiotic contents in filtrates were determined accurately using calibration curves based on standard solutions prepared with 1/15 M phosphate buffer, pH 7.4. Four cephems, ceftriaxone (CTRX), cefazolin (CEZ), BMY-28100 and cefadroxil (CDX) were examined in human serum and rat liver tissues. Corrections were made for antibiotic recoveries into 1/15 M phosphate buffer, pH 7.4. CTRX, CEZ, BMY-28100 and CDX in serum and tissues were recovered into buffer at rates of 98.4-101.6%, 97.6-102.0%, 99.8-101.4% and 97.5-98.2% of of spiked (theoretical) values, respectively regardless of antibiotic concentrations. Furthermore, these concentrations obtained using the present bioassay method were well in agreement with those obtained by the HPLC method. When BMY-28100 was administered to volunteers, concentrations of BMY-28100 in serum obtained by the present bioassay method were well in agreement with those obtained by the usual bioassay method which required the fresh human serum to prepare the standard solutions.

Animals↗

Truncated STAT proteins are prevalent at relapse of acute myeloid leukemia.

Signal transducer and activator of transcription (STAT) proteins are implicated in the control of cell survival, proliferation and differentiation in response to hematopoietic cytokines. C-terminally truncated STAT isoforms (STATbeta), as opposed to the full length form (STATalpha), have a competitive or even transdominant negative effect on gene induction mediated by the STAT pathway. We have previously demonstrated that while constitutively active STAT proteins were detected in ten of 36 (28%) for STAT3 and eight of 36 (22%) for STAT5 in pretreatment samples from newly diagnosed acute myeloid leukemia (AML) patients, a significantly larger fraction of samples [21 of 27 (78%)] expressed STATbeta proteins. To determine whether STATbeta expression was maintained or increased after relapse in AML, we compared STAT activity and isoform expression at diagnosis and at relapse in 17 patients. In this selected group, constitutively active STAT3 was detected in 13 of 17 (76%) AML samples at diagnosis but was detected in only four of these patients at relapse. Constitutively active STAT5 was detected in three of 17 (18%) AML samples at diagnosis; but only two at relapse. In contrast, STATbeta protein expression was observed in 12 of the 17 pretreatment samples (71%) and in 16 of 17 samples at relapse. Only one patient did not express STATbeta at relapse. Our results suggest that STATbeta isoform expression, rather than level of constitutive activity, may be involved in disease progression in AML.

Adult↗

Influence of physicochemical treatments on spent palladium based catalyst for catalytic oxidation of VOCs.

To recycle the spent catalyst for the removal of VOCs, the benzene, toluene, and xylene (BTX) complete oxidations were studied over pretreated palladium based spent catalyst in a fixed bed flow reactor system at atmospheric pressure. Two different pretreatment methods with gas (air and hydrogen) and acid aqueous solution (HCl, H(2)SO(4), HNO(3), H(3)PO(4) and CH(3)COOH) were used to investigate the catalytic activity of spent catalyst. The properties of the spent and pretreated Pd based catalyst were characterized by XRD, BET, TEM, ICP, and XPS. The results of light-off curves indicate that the catalytic activity of toluene oxidation for pretreated samples is in the order of hydrogen>air>HNO(3)>CH(3)COOH>H(2)SO(4)>H(3)PO(4)>HCl. In addition, the air and the acid aqueous pretreated catalyst activities were significantly decreased compared to that of the spent (or parent) catalyst. Moreover, hydrogen pretreated (or reduced) catalysts having mainly metallic form show the best performance in removing the toluene vapours compared to other pretreated samples. The reduction temperature made a significant difference in the catalytic performance of the spent catalyst pretreated with hydrogen. XPS results clearly supported that the palladium state of the spent catalysts pretreated at 300 degrees C was shifted more toward metallic form than other reduced catalysts. Furthermore, the results of a long-term test and catalytic activity of aromatic hydrocarbons also supported that the hydrogen pretreated spent catalyst was a good candidate for removing toxic compounds.

Acids↗

Analysis of nicotine, 3-hydroxycotinine, cotinine, and caffeine in urine of passive smokers by HPLC-tandem mass spectrometry.

BACKGROUND: A method is described for the simultaneous analysis of nicotine and two of its major metabolites, cotinine and 3-hydroxycotinine, as well as for caffeine from urine samples. The method was developed to assess exposure of restaurant and hotel workers to environmental tobacco smoke. METHODS: The method includes sample pretreatment and reversed-phase HPLC separation with tandem mass spectrometric identification and quantification using electrospray ionization on a quadrupole ion trap mass analyzer. Sample pretreatment followed standard protocols, including addition of base before liquid-liquid partitioning against dichloromethane on a solid matrix, evaporation of the organic solvent using gaseous nitrogen, and transferring to HPLC vials using HPLC buffer. HPLC separation was run on-line with the electrospray ionization-tandem mass spectrometric detection. RESULTS: The detection limits of the procedure were in the 1 microg/L range, except for nicotine (10 microg/L of urine). Still lower detection limits can be achieved with larger sample volumes. Recoveries of the sample treatment varied from 99% (cotinine) to 78% (3-hydroxycotinine). CONCLUSIONS: The method described is straightforward and not labor-intensive and, therefore, permits a high throughput of samples with excellent prospects for automation. The applicability of the method was demonstrated in a small-scale study on restaurant employees.

Caffeine↗

Quantitative analysis of l-alpha-acetylmethadol, l-alpha-acetyl-N-normethadol, and l-alpha-acetyl-N,N-dinormethadol in human hair by positive ion chemical ionization mass spectrometry.

A sensitive and specific method was developed for the quantitative analysis of l-alpha-acetylmethadol (LAAM), l-alpha-acetyl-N-normethadol (norLAAM), and l-alpha-acetyl-N,N-dinormethadol (dinorLAAM) in hair. In the development of this method, it was determined that sample pretreatment methods performed by the laboratory greatly affect the measured concentrations of drug and metabolite in hair. Deuterated internal standards were added to 20-mg hair samples and the samples digested overnight in a buffered solution of Protease Type VIII enzyme. Digests were extracted by modification of a liquid-liquid extraction procedure developed previously in our laboratory for the analysis of plasma and tissues. Derivatized extracts were analyzed on a Finnigan MAT 4500 mass spectrometer in positive ion chemical ionization mode using methane and ammonia reagent gases, helium carrier gas, and a DB-5MS (30 m, 0.25-micron film thickness) capillary column. The assay was linear to 50 ng/mg hair (r = 0.99) for all three compounds with a limit of quantitation experimentally determined to be 0.5 ng/mg for LAAM and 0.3 ng/mg for norLAAM and dinorLAAM. Intra-assay precision ranged from 1.0 to 10.5% for the three analytes at concentrations of 0.5, 5.0, and 25.0 ng/mg of hair. Interassay precision ranged from 4.7 to 12.9%. The performance of the method was also evaluated for its utility in detecting and quantitating LAAM, norLAAM, and dinorLAAM in hair from rats (n = 6) that had been administered 3 mg/kg LAAM intraperitoneally once daily for five days. LAAM, norLAAM and dinorLAAM were detectable in pigmented hair at concentrations of 1.27 ng/mg (+/-0.04), 1.28 ng/mg (+/-0.014), and 2.89 ng/mg (+/-0.014), respectively. Five laboratory wash solvents were then evaluated for their effect on the measured concentration of LAAM and metabolites in the rat hair. Phosphate buffer and 1% SDS washes substantially reduced the measured LAAM, norLAAM, and dinorLAAM concentrations by at least 30%, which suggests that drug incorporated into hair is removed (extracted) during the laboratory wash procedures. Wash procedures using methanol, methylene chloride, or water reduced the measured concentrations by no more than 20%. Because measured concentrations of LAAM, norLAAM, and dinorLAAM in hair appear to depend on the specific wash procedures used by a laboratory, quantitative data must be interpreted cautiously based on the sample pretreatment conditions.

Animals↗

Determination of serum amantadine by liquid chromatography-tandem mass spectrometry.

BACKGROUND: Amantadine (1-adamantylamine) is used for treatment of influenza, hepatitis C, parkinsonism, and multiple sclerosis. Current amantadine analysis by HPLC or gas chromatography (GC) requires a laborious sample pretreatment with extraction and/or derivatization steps. We established an LC-MS/MS method without protein precipitation, centrifugation, extraction and derivatization steps. MATERIAL AND METHODS: 50 microl sample+50 microl of 0.4 mg/l 1-(1-adamantyl)pyridinium bromide as internal standard+1000 microl water (96-well plate). Of this 25 microl+500 microl water (96-well plate; final serum dilution 1:462). LC-MS/MS: Surveyor MS pump, Autosampler, triple-quadrupole TSQ Quantum mass spectrometer (Thermo Electron). Autosampling: 2 microl of each sample. Chromatography: isocratic water/acetonitrile (60/40 v/v) with 5 g/l formic acid, flow rate 0.2 ml/min, run time 3 min, Phenomenex Luna C8(2) (100 x 2.0 mm (i.d.); 3-microm bead size) column. Mass spectrometry: electrospray atmospheric pressure ionization, positive ion and selective reaction monitoring mode, ion transitions m/z 152.0-->135.1 (at 22 eV amantadine) and 214.1-->135.1 (at 26 eV internal standard). RESULTS: Calibration curves were constructed with spiked serum samples (amantadine 50-1000 microg/l, r>0.99). No carry over (5000 microg/l). No ion suppression with retention times similar to those of amantadine (1.8 min) and the internal standard (2.1 min). Detection limit 20 mg/l, linearity 20-5000 mg/l, intra-assay/inter-assay CV<6%/<8%, recovery 99-101%. Method comparison: LC-MS/MS=1.23 x GC-45 (Passing-Bablok regression). No significant bias between GC and LC-MS/MS (Bland-Altman plot). CONCLUSION: We consider the sample pretreatment without deproteination, derivatization and centrifugation steps and the specificity of the tandem mass spectrometry as the most important points of our amantadine analysis method.

Amantadine↗

Chromatographic analysis of 1,3-bis(dimethylamino)isopropyl 4-chlorophenoxyacetate dihydrochloride, a new CNS stimulant.

A reversed-phase liquid chromatographic method is developed for the assay of the new CNS stimulant, 1,3-bis(dimethylamino)isopropyl 4-chlorophenoxyacetate dihydrochloride (BCE-001), and its main contaminant, 4-chlorophenoxyacetic acid (PCPA). In the first place the possible reactions of BCE-001 with mobile phase components are investigated and it is found that BCE-001 is readily hydrolysed in water and undergoes transesterification in methanol or ethanol. The methyl ester is formed rapidly and quantitatively so that BCE-001 can be assayed as methyl 4-chlorophenoxyacetate. PCPA is formed as a result of the hydrolysis of BCE-001 during the sample pretreatment and chromatographic separation and this causes an overestimate of the PCPA impurity in the bulk drug. An effective method is developed to prevent the hydrolysis of BCE-001 during sample pretreatment.

2,4-Dichlorophenoxyacetic Acid↗

Improved liquid chromatographic determination of procainamide and N-acetylprocainamide in serum.

A liquid chromatographic method for the determination of procainamide (PA) and N-acetylprocainamide (NAPA) in serum has been developed. This method utilizes isocratic conditions, ambient temperature, and a conventional fixed-wavelength 280-nm detector. Sample pretreatment involves extraction of PA and NAPA, along with p-amino-N-(2-dipropylaminoethyl)-benzamide hydrochloride as internal standard, into an organic phase and reextraction into an aqueous acidic phase. Using this sample pretreatment, interferences due to commonly used drugs are eliminated. The method accurately measures PA and NAPA to levels as low as 1 mg/L.

Acecainide↗

Capillary electrophoresis as a versatile tool for the bioanalysis of drugs--a review.

This review article presents an overview of current research on the use of capillary electrophoretic techniques for the analysis of drugs in biological matrices. The principles of capillary electrophoresis and its various separation and detection modes are briefly discussed. Sample pretreatment methods which have been used for clean-up and concentration are discussed. Finally, an extensive overview of bioanalytical applications is presented. The bioanalyses of more than 200 drugs have been summarised, including the applied sample pretreatment methods and the achieved detection limits.

Chromatography, Micellar Electrokinetic Capillary↗

Effect of pretreatment with epoxy compounds on the mechanical properties of bovine pericardial bioprosthetic materials.

Early failures of bovine pericardial heart valves are due to leaflet perforation, tearing and calcification. Since glutaraldehyde fixation has been shown to produce marked changes in leaflet mechanics and has been linked to development of calcification, bovine pericardium fixed with the four hydrophilic epoxy formulations and their mechanical properties are studied in this paper. We measured the thicknesses, shrinkage temperatures, stress relaxations and stress-strain curves of bovine pericardiums after different treatments with (1) non-treatment (fresh), (2) glutaraldehyde (GA), (3) epoxy compounds followed by the posttreatment with GA (EP 1#, EP 2#), and (4) epoxy compounds (EP 3# and EP 4#). Results of this study showed that the hydrophilic epoxy compounds are good crosslinking agents. There are no significant differences of shrinkage temperature and ultimate tensile stress among all tissue samples pretreated with GA, EP 1# and EP 2#. However, the stress relaxations of tissue-samples pretreated with epoxy compounds followed by the posttreatment with GA (EP 1# and EP 2#) are significantly slower than that pretreated with GA, and the strains at fracture of EP 1# and EP 2# are also significantly larger than that of GA or epoxy compounds. These facts show that the bovine pericardium pretreated with the epoxy compound followed by the posttreatment with GA (EP 1# and EP 2#) possesses greater tenacity and potential durability in dynamic stress.

Animals↗

Comparison of ion chromatographic methods based on conductivity detection, post-column-reaction and on-line-coupling IC-ICP-MS for the determination of bromate.

An established method for the determination of the disinfection by-product bromate is ion chromatography (IC). This paper presents a comparison of three IC methods based on either conductivity detection (IC-CD), a post-column-reaction (IC-PCR-VIS) or the on-line-coupling with inductively coupled plasma mass spectrometry (IC-ICP-MS). Main characteristics of the methods such as method detection limits (MDL), time of analysis and sample pretreatment are compared and applicability for routine analysis is critically discussed. The most sensitive and rugged method is IC-ICP-MS, followed by IC-PCR-VIS. The photometric detection is subject to a minor interference in real world samples, presumably caused by carbonate. The lowest sensitivity is shown by the IC-CD method as slowest method compared, which, in addition, requires a sample pretreatment. The highest amount of information is delivered by IC-PCR-VIS, which allows the simultaneous determination of the seven standard anions and bromate.

Anions↗