Solid-phase microextraction with temperature-programmed desorption for the analysis of iodination disinfection byproducts.

An analytical approach for the determination of chlorination and iodination disinfection byproducts based on solid-phase microextraction (SPME) was developed. Solid-phase microextraction presents a simple, rapid, sensitive, and solvent-free approach to sample preparation in which analytes in either air or water matrixes are extracted into the polymeric coating of an optical fiber. Analytes are subsequently thermally desorbed in the injection port of a gas chromatograph for separation, detection, and quantitation. Thermal degradation of iodoform was observed during desorption from a polyacrylate fiber in initial GC/MS and GC/ECD experiments. Experiments were designed to determine SPME conditions that would allow quantification without significant degradation of analytes. Isothermal and temperature-programmed thermal desorptions were evaluated for efficacy in transferring analytes with wide-ranging volatilities and thermal stabilities into chromatographic analysis columns. A temperature-programmed desorption (TPD) (120-200 degrees C at 5 degrees C/min with an on-column injection port or 150-200 degrees C at 25 degrees C/min with a split/splitless injection port) was able to efficiently remove analytes with wide-ranging volatilities without causing thermal degradation. The SPME-TPD method was linear over 2-3 orders of magnitude with an electron capture detector and detection limits were in the submicrogram per liter range. Precision and detection limits for selected trihalomethanes were comparable to those of EPA method 551. Extraction efficiencies were not affected by the presence of 10 mg/L soap, 15 mg/L sodium iodide, and 6000 mg/L sodium thiosulfate. The SPME-TPD technique was applied to the determination of iodination disinfection byproducts from individual precursor compounds using GC/MS and to the quantitation of iodoform at trace levels in a water recycle system using GC/ECD.

Disinfectants↗

Monitoring of PAHs in air by collection on XAD-2 adsorbent then microwave-assisted thermal desorption coupled with headspace solid-phase microextraction and gas chromatography with mass spectrometric detection.

Microwave-assisted thermal desorption (MAD) coupled to headspace solid-phase microextraction (HS-SPME) has been studied for in-situ, one-step, sample preparation for PAHs collected on XAD-2 adsorbent, before gas chromatography with mass spectrometric detection. The PAHs on XAD-2 were desorbed into the extraction solution, evaporated into the headspace by use of microwave irradiation, and absorbed directly on a solid-phase microextraction fiber in the headspace. After desorption from the SPME fiber in the hot GC injection port, PAHs were analyzed by GC-MS. Conditions affecting extraction efficiency, for example extraction solution, addition of salt, stirring speed, SPME fiber coating, sampling temperature, microwave power and irradiation time, and desorption conditions were investigated. Experimental results indicated that extraction of 275 mg XAD-2, containing 10-200 ng PAHs, with 10-mL ethylene glycol-1 mol L(-1) NaCl solution, 7:3, by irradiation with 120 W for 40 min (the same as the extraction time), and collection with a PDMS-DVB fiber at 35 degrees C, resulted in the best extraction efficiency. Recovery was more than 80% and RSD was less than 14%. Optimum desorption was achieved by heating at 290 degrees C for 5 min. Detection limits varied from 0.02 to 1.0 ng for different PAHs. A real sample was obtained by using XAD-2 to collect smoke from indoor burning of joss sticks. The amounts of PAHs measured varied from 0.795 to 2.53 ng. The method is a simple and rapid procedure for determination of PAHs on XAD-2 absorbent, and is free from toxic organic solvents.

Adsorption↗

Electrochemically controlled solid-phase microextraction and preconcentration using polypyrrole coated microarray electrodes in a flow system.

Polypyrrole coated microarray electrodes have been used for electrochemically controlled solid-phase microextraction and preconcentration on individually addressable gold microband electrodes. In this study, a flow of analyte solution was maintained over the band electrodes by positioning a capillary in a vertical position over the electrode array during both the extraction and the detection of the desorbed compounds. This experimental set-up was used to evaluate the possibilities of using electrochemically controlled solid-phase microextraction with conducting polymers as a preconcentration step in miniaturised flow systems. The performance of the polymer, which was prepared by electrochemical polymerisation using a solution of 0.05 M pyrrole and 0.1 M LiClO4, was investigated using chloride as a model analyte employing different extraction times and analyte concentrations. It was found that significant preconcentration was possible using extraction times of only a few minutes and that a good linearity between the extraction time and detection response was present both for mM and microM chloride concentrations. Compared to a recent study (Liljegren et al., Analyst, 2002, 127, 591-597), using a more traditional solid-phase microextraction technique under electrochemical control, the preconcentration factor could be increased by a factor of about 210 by using the present flow system based approach. This increase in the preconcentration factor can be explained by the significant decrease in the desorption volume (i.e. reduced dilution of the desorbed analyte) associated with the use of the present flow system. With the present approach, the detection limit for the model analyte chloride could be decreased from 10 microM to 625 nM employing an extraction time of 180 s.

Journal Article↗

Multiple headspace solid-phase microextraction for the quantitative determination of volatile organic compounds in multilayer packagings.

The theory of multiple headspace solid-phase microextraction (HS-SPME) and a method based on multiple HS-SPME for the quantitative determination of volatile organic compounds (VOCs) in packaging materials is presented. The method allows the direct analysis of solid samples without using organic solvents to extract analytes. Multiple headspace solid-phase microextraction is a stepwise method proposed to eliminate the influence of the sample matrix on the quantitative analysis of solid samples by HS-SPME. Different amounts of packaging and different volumes of standard solution were studied in order to remove a substantial quantity of analytes from the headspace at each extraction and obtain the theoretical exponential decay of the peak area of the four successive extractions and, thus, the total area was calculated from these four extractions. In addition, two fibres were compared: carboxen-polydimethylsiloxane (CAR-PDMS) and divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS), as they showed differences in the linearity of the exponential decay with the number of extractions depending on the compound. The CAR-PDMS fibre was better for the VOCs with a low molecular mass, whereas the DVB-CAR-PDMS fibre was better for the VOCs with a high molecular mass. Finally, the method was characterised in terms of linearity, detection limit and reproducibility and applied to analyse four multilayer packaging samples with different VOCs contents.

Organic Chemicals↗

Determination of chlorophenols in soil samples by microwave-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-electron-capture detection.

Microwave-assisted extraction coupled to headspace solid-phase microextraction was studied and applied for one-step in-situ sample preparation prior to analysis of chlorophenols (CPs) in soil samples. The CPs in soil sample were extracted into the aqueous solution and then directly onto the solid-phase microextraction (SPME) fiber in headspace under the aid of microwave irradiation. After being desorbed from SPME fiber in the GC injection port, CPs were analyzed with a GC-electron-capture detection system. Parameters affecting the extraction efficiency such as the extraction solutions, the pH in the slurry, the humic acid content in the soil, the power and the irradiation time of microwave as well as the desorption parameters were investigated. Experimental results indicated that the extraction of a 1.0 g soil sample with a 6-ml aqueous solution (pH 2) and a polyacrylate fiber under the medium-power irradiation (132 W) for 9 min achieved the best extraction efficiency of about 90% recovery and less than 10% RSD. Desorption was optimal at 300 degrees C for 3 min. Detection limits were obtained at around 0.1-2.0 microg/kg levels. The proposed method provided a simple, fast, and organic solvent-free procedure to analyze CPs from soil sample matrix.

Chlorophenols↗

New cold-fiber headspace solid-phase microextraction device for quantitative extraction of polycyclic aromatic hydrocarbons in sediment.

A new automated headspace solid-phase microextraction (HS-SPME) sampling device was developed, with the capability of heating the sample matrix and simultaneously cooling the fiber coating. The device was evaluated for the quantitative extraction of polycyclic aromatic hydrocarbons (PAHs) from solid matrices. The proposed device improves the efficiency of the release of analytes from the matrix, facilitates the mass transfer into the headspace and significantly increases the partition coefficients of the analytes, by creating a temperature gap between the cold-fiber (CF) coating and the hot headspace. The reliability and applicability of previously reported cold-fiber devices are significantly enhanced by this improvement. In addition, it can be easily adopted for full automation of extraction, enrichment and introduction of different samples using commercially available autosampling devices. Sand samples spiked with PAHs were used as solid matrices and the effect of different experimental parameters were studied, including the extraction temperature, extraction time, moisture content, and the effect of sonication and modifier under optimal experimental conditions, linear calibration curves were obtained in the range of 0.0009-1000 ng/g, with regression coefficients higher than 0.99 and detection limits that ranged from 0.3 to 3 pg/g. Reproducible, precise and high throughput extraction, monitoring and quantification of PAHs were achieved with the automated cold-fiber headspace solid-phase microextraction (CF-HS-SPME) device coupled to GC-flame ionization detection. Determination of PAHs in certified reference sediments using the proposed approach exhibited acceptable agreement with the standard values.

Calibration↗

Analysis of polychlorinated biphenyls in aqueous samples by microwave-assisted headspace solid-phase microextraction.

The hyphenated technique namely microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed and studied for the simultaneous extraction/enrichment of polychlorinated biphenyls (PCBs) in aqueous samples prior to the quantification by gas chromatography (GC). The PCBs in aqueous media are extracted onto a solid-phase micro fibre via the headspace with the aid of microwave irradiation. The optimum conditions for obtaining extraction efficiency, such as the extraction time, addition of salts, addition of methanol, ratio of sample to headspace volume, and the desorption parameters were investigated. Experimental results indicated that the proposed MA-HS-SPME method attained the best extraction efficiency under the optimized conditions, i.e., irradiation of extraction solution (20 ml aqueous sample in 40 ml headspace vial with no additions of salt and methanol) under 30 W microwave power for 15 cycles (1 min power on and 3 min power off of each cycle). Desorption at 270 degrees C for 3 min provided the best detection results. The detection limit obtained were between 0.27 and 1.34 ng/l. The correlation coefficient for the linear dynamic range from 1 to 80 ng/l exceeded 0.99 for 18 PCBs.

Chromatography, Gas↗

Unbreakable solid-phase microextraction fibers obtained by sol-gel deposition on titanium wire.

Solid-phase microextraction commercial fibers present a few drawbacks such as relatively low recommended operating temperature, instability and swelling in organic solvents, breakage of the fiber, stripping of coatings, and bending of the needle. Some of these problems have been obviated by covalent bonding of the polymer phase to the fused-silica substrate by sol-gel, but the easy breakage of the fiber remains a problem. In the present work, the known occurrence of titanol groups at the surface of titanium wire was exploited to produce sol-gel fibers supported on this unbreakable substrate. Scanning electron microscopy analysis revealed the film formation on titanium wire surface while temperature and solvent stability as well as durability tests showed that the sol-gel film was tightly attached to the substrate, thus suggesting covalent bonding. The use of this type of fiber is currently generalized in our laboratory without any breakage or stripping out incidents up to the moment.

Gels↗

Multiple headspace solid-phase microextraction of 2-cyclopentyl-cyclopentanone in polyamide 6.6: possibilities and limitations in the headspace analysis of solid hydrogen-bonding matrices.

The interactions between a polar analyte, 2-cyclopentyl-cyclopentanone, and a solid polar matrix, polyamide 6.6, during multiple headspace solid-phase microextraction (MHS-SPME) were studied. Strong hydrogen bonding between the analyte and the matrix was observed and shown to cause slow migration and adsorption of the analyte. These matrix effects led to erroneous quantitation despite the use of multiple headspace extraction. Addition of water disrupted the hydrogen bonding between the analyte and the matrix and a valid quantitation was achieved. The addition of water also increased the sensitivity and allowed the identification of 2,5-bis(cyclopentyl)-1-cyclopentanone. The amount of 2-cyclopentyl-cyclopentanone in five different polyamide 6.6 samples was measured using the developed multiple headspace solid-phase microextraction method with water-displacer. The measured concentrations were in the range of 1.44-15.61 microg/g. These concentrations were up to 30% higher than the concentrations measured after microwave-assisted extraction (MAE), which indicates incomplete recovery by MAE. The use of water as a displacer eliminated the matrix effects and complete recovery of the analyte was achieved by MHS-SPME.

Cyclopentanes↗

Steam distillation-solid-phase microextraction for the detection of Ephedra sinica in herbal preparations.

A new method involving concurrent solid-phase microextraction combined with continuous hydrodistillation of essential oil was developed. This new methodology allowed for the detection by GC-MS of very small amounts of a diagnostic peak for the authentication of Ephedra sinica, in a short period of time and using only small sample sizes. This diagnostic peak was identified as 4-vinylanisole, and elucidated from the chromatographic profile allowed for the identification of a sample as E. sinica among other species investigated in this study. To the best of our knowledge this is the first report on using continuous solid-phase microextraction coupled to hydrodistillation for the investigation of essential oil components, and the first report of 4-vinylanisole as a marker compound for E. sinica. A total of 46 collections representing 21 species of Ephedra were studied.

Automation↗

Nano-structured lead dioxide as a novel stationary phase for solid-phase microextraction.

The first study on the high efficiency of nano-structured lead dioxide as a new fiber for solid-phase microextraction (SPME) purposes has been reported. The size of the PbO2 particles was in the range of 34-136 nm. Lead dioxide-based fibers were prepared via electrochemical deposition on a platinum wire. The extraction properties of the fiber to benzene, toluene, ethylbenzene, and xylenes (BTEX) were examined using headspace solid-phase microextraction (HS-SPME) mode coupled to gas chromatography-flame ionization detection (GC-FID). The results obtained proved the suitability of proposed fibers for the sampling of organic compounds from water. The extraction procedure was optimized by selecting the appropriate extraction parameters, including preparation conditions of coating, salt concentration, time and temperature of adsorption and desorption and stirring rate. The calibration graphs were linear in a concentration range of 0.1-100 microg l(-1) (R2 > 0.994) with detection limits below 0.012 microg l(-1) level. Single fiber repeatability and fiber-to-fiber reproducibility were less than 10.0 and 12.5%, respectively. The PbO2 coating was proved to be very stable at relatively high temperatures (up to 300 degrees C) with a high extraction capacity and long lifespan (more than 50 times). Higher chemical resistance and lower cost are among the advantages of PbO2 fibers over commercially available SPME fibers. Good recoveries (81-108%) were obtained when environmental samples were analyzed.

Adsorption↗

Detection of substituted benzenes in water at the pg/ml level using solid-phase microextraction and gas chromatography-ion trap mass spectrometry.

Solid-phase microextraction (SPME) is combined with gas chromatography-ion trap mass spectrometry (GC-IT-MS) for the analysis of benzene, toluene, ethyl benzene and xylene isomers (BTEX) in water. SPME is a recent technique for extracting organics from an aqueous matrix into a stationary phase immobilized on a fused-silica fiber. The analytes are thermally desorbed directly in the injector of a gas chromatograph. The wide linear dynamic range (five orders of magnitude) and pg sensitivity of the ion trap mass spectrometer in its full scan mode is an ideal detector for identifying and quantifying the analytes extracted with an SPME device. The combined method SPME-GC-IT-MS, using fibers coated with a 100-microns polydimethylsiloxane coating, showed a limit of quantitation (LOQ) of 50 pg/ml benzene in water. This corresponds to 5 pg of benzene absorbed onto the fiber. The limit of detection (LOD) was 15 pg/ml benzene. For o-xylene spiked at 50 pg/ml in water 50 pg were absorbed by the fiber indicating an LOQ and LOD 10 times better than for benzene. The detection limits obtained exceed the requirements of both the United States Environmental Protection Agency method 524.2 and the Ontario Municipal/Industrial Strategy for Abatement program, which range from 30 to 80 pg/ml and 500 to 1100 pg/ml, respectively. The linearity of the method extended over five orders of magnitude. Relative standard deviation ranged from 2.7 to 5.2% for 15 ng/ml BTEX in water and from 5.5 to 7.5% for 50 pg/ml BTEX in water. SPME-GC-IT-MS was used to evaluate the contamination level in laboratory, potable and wastewater sources.

Benzene Derivatives↗

Determination of polydimethylsiloxane-seawater distribution coefficients for polychlorinated biphenyls and chlorinated pesticides by solid-phase microextraction and gas chromatography-mass spectrometry.

Applications of solid-phase microextraction (SPME) in the measurement of very hydrophobic organic compounds (VHOCs) are limited, partly due to the difficulty of calibrating SPME fibers for VHOCs. This study used a static SPME strategy with a large sample volume (1.6 L) and a five-point calibration procedure to determine the distribution coefficients for a large suite of polychlorinated biphenyls (PCBs) and chlorinated pesticides between a polydimethylsiloxane (PDMS) phase (100 microm thickness) coated on a glass fiber and seawater. An extraction time of 12 days was deemed adequate for equilibrium calibration from kinetic experiments. Two groups of randomly selected fibers divided into three batches (up to nine fibers in each batch) were processed separately with two gas chromatography-mass spectrometry (GC-MS) systems. Matrix effects arising from losses of the analytes to glass container walls and stirring bars were corrected. Relative standard deviations within the same batch were generally smaller than those for the entire group. Furthermore, KfVf (Kf and Vf are the distribution coefficient of an analyte between the polymer-coated fiber and aqueous phase and the fiber volume, respectively) values determined with two GC-MS systems were statistically different. These results indicate the calibrated KfVf values were less affected by the random selection of SPME fibers than by other experimental conditions, and therefore average KfVf values may be used for the same type of commercially available SPME fibers. The relative accuracy of our calibration method was similar to that of a previous study [P. Mayer. W.H.J. Vaes, J.L.M. Hermens, Anal. Chem. 72 (2000) 459] employing different coating thickness and calibration procedure. The present study also obtained a bell-shaped relationship between log Kf and log Kow (octanol-water partition coefficient) for PCB congeners with the maximum log Kf corresponding to log Kow approximately 6.5. This bell-shaped relationship was attributed mainly to steric effects arising from the interplay between the PDMS thickness and molecular sizes of the target analytes.

Chemistry Techniques, Analytical↗

Determination of volatile oak compounds in wine by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A headspace solid-phase microextraction (HS-SPME) and gas chromatography (GC) coupled to mass spectrometry (MS) method was developed to identify and quantify 14 volatile oak compounds in aged red wines. The most important HS-SPME variables were optimised by experimental design technique in order to improved the extraction process. The selected conditions were: 10 mL of sample in 20 mL sealed vials with addition of 30% of sodium chloride (saturated solution), divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fibre, 10 min of pre-incubation time, 70 degrees C of temperature and 60 min of extraction time without agitation. The features of the method were established for the studied compounds in terms of linear range, slope and intercept of the calibration graphs, detection and quantification limits and repeatability. For all compounds detection limits were below their threshold levels and repeatability, in terms of relative standard deviation, was good, with values between 3 and 11%. Finally, the method was applied to the analysis of six aged red wines by both internal standard and standard addition calibration methods. The concentrations obtained with both methods were statistically compared.

Gas Chromatography-Mass Spectrometry↗

Recent developments in solid-phase microextraction coatings and related techniques.

During the last decade, solid-phase microextraction (SPME) has gained widespread acceptance for analyte matrix separation and preconcentration. Relatively few data are currently available dealing with in-house production of fibres with tailor-made properties to be used for SPME, though recently the number of publications evaluating new coatings has been considerably growing. This review, centred on publications that appeared during the last five years, is resuming different approaches which can be used for fibre production and further summarises alternative techniques closely related to SPME, such as in-tube extraction or single-drop microextraction (SDME). The aim is to give the reader a concise overview of recent developments in new coating procedures and materials, including the respective applications.

Chemical Fractionation↗

Application of the polysilicone fullerene coating for solid-phase microextraction in the determination of semi-volatile compounds.

Solid-phase microextraction using polysilicone fullerene (PF) coating has been applied for the determination of semi-volatile compounds. Detection limits at the 10 ng l(-1) to approximately microg l(-1) level were achieved using flame ionization detection. A wide linear range was obtained with precision below 7% relative standard deviation. Parameters that affect the extraction process were investigated, which included sampling time, desorption time, sampling temperature, and salting out effect. Compared to the non-polar commercial polydimethylsiloxane (PDMS) coating, the PF coating has higher extraction efficiency, better selectivity and greater sensitivity for aromatic compounds. The experimental results revealed the thermal stability and life span are superior to commercially available PDMS. The PF coating has been demonstrated to possess planarity molecular recognition. The theoretical study confirmed that quantification is feasible under non-equilibrium conditions by use of the PF coating.

Reproducibility of Results↗

Optimisation of headspace solid-phase microextraction for analysis of aromatic compounds in vinegar.

Headspace solid-phase microextraction has been applied to the analysis of aroma compounds in vinegar. Silica fibre coated with Carboxen-polydimethylsiloxane was found to be more efficient at extracting these compounds than other fibres such as those coated with polydimethylsiloxane, Carbowax-divinylbenzene, and polydimethylsiloxane-divinylbenzene, but its repeatability was low. Different parameters such as extraction time, temperature of the sample during the extraction, ionic strength, and sample volume were optimised using a two-level factorial design expanded further to a central composite design. This chemometric tool is very appropriate in screening experiments where the aim is to investigate several possibly influential and/or interacting factors. The extraction efficiency is inversely affected by the acetic acid content-an increase in the acetic acid concentration decreases the extraction efficiency. No interference is observed with the increase in content of polyphenols.

Acetic Acid↗

Optimisation of a solid-phase microextraction method for synthetic musk compounds in water.

A solid-phase microextraction method (SPME) for determining trace levels of synthetic musk fragrances in residual waters has been developed. Six polycyclic musks (cashmeran, phantolide, celestolide, traseolide, galaxolide and tonalide), and a macrocyclic musk (ambrettolide) have been analysed. A detailed study of the different parameters affecting the extraction process is presented. The main important factors affecting the microextraction process have been studied and optimised by means of a categorical factorial design. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using four different fiber coatings [polydimethylsiloxane (PDMS), Carboxen (CAR)-PDMS, PDMS-divinylbenzene (DVB) and Carbowax (CW)-DVB]. An extraction temperature of 100 degrees C sampling the headspace over the sample using CAR-PDMS or PDMS-DVB as fiber coatings were found to be the experimental conditions that lead to a more effective extraction. The method proposed is very simple and yields high sensitivity, with detection limits in the low pg/ml, good linearity and repeatability for all the target compounds. The total analysis time, including extraction and GC analysis, was only 45 min. The optimised method performed well when it was applied to waste water from an urban treatment plant.