Real time biosensor analysis of staphylococcal enterotoxin A in food.

Currently there is no 'real-time' detection system to identify food borne toxins. In order to develop such a system, we have used a evanescent wave biosensor for real time detection of staphylococcal enterotoxin A (SEA) in foods. The approach used here is sandwich biosensor, a method utilizing two antibodies. The toxin binds initially to a capturing antibody which is bound covalently on the surface of the biosensor detector. The second antibody binds to the captured toxin. We were able to measure SEA in foods with little or no background interference, demonstrating that biosensor-based measurement of SEA was possible not only with purified SEA but also in complex food matrices such as hot dogs, potato salad, milk and mushrooms. Autoclaved samples of SEA did not evoke a positive response. With both purified SEA and SEA-spiked foods, the assay sensitivity is 10-100 ng/g depending on the material tested and the assay is rapid ( <4 min) when a single antibody is used.

Animals↗

A single-fractal analysis of cellular analyte-receptor binding kinetics utilizing biosensors.

A fractal analysis of a confirmative nature only is presented for cellular analyte-receptor binding kinetics utilizing biosensors. Data taken from the literature can be modeled by using a single-fractal analysis. Relationships are presented for the binding rate coefficient as a function of the fractal dimension and for the analyte concentration in solution. In general, the binding rate coefficient is rather sensitive to the degree of heterogeneity that exists on the biosensor surface. It is of interest to note that examples are presented where the binding coefficient, k exhibits an increase as the fractal dimension (D(f)) or the degree of heterogeneity increases on the surface. The predictive relationships presented provide further physical insights into the binding reactions occurring on the surface. These should assist in understanding the cellular binding reaction occurring on surfaces, even though the analysis presented is for the cases where the cellular "receptor" is actually immobilized on a biosensor or other surface. The analysis suggests possible modulations of cell surfaces in desired directions to help manipulate the binding rate coefficient (or affinity). In general, the technique presented is applicable for the most part to other reactions occurring on different types of biosensor or other surfaces.

Animals↗

Potential of biosensor technology for the characterization of interactions by quantitative affinity chromatography.

This review places the characterization of interactions by biosensor technology in the broader context of their study by quantitative affinity chromatography. The general reluctance to consider biosensor-based characterization as a form of quantitative affinity chromatography on the grounds of a difference in aims of the two techniques reflects a mistaken belief that BIAcore and IAsys studies characterize the kinetics of the chemical reaction responsible for biospecific adsorption of a soluble reactant to an immobilized form of its affinity partner. It now transpires that the association and dissociation rate constants thereby determined refer to thermodynamic characterization of biospecific adsorption in terms of a single-phase model in which affinity sites are distributed uniformly throughout the liquid-phase volume accessible to the partitioning reactant--the model used for characterization of biospecific adsorption by quantitative affinity chromatography. In that light the most important attribute of biosensor technology is its potential for thermodynamic characterization of biospecific adsorption by virtue of its ability to monitor complex formation directly; and hence its potential for the characterization of interactions with affinities that are too strong for study by forms of quantitative affinity chromatography that monitor complex formation on the basis of reactant depletion from the liquid phase. Kinetic as well as thermodynamic analyses of biosensor data are described for attainment of that potential.

Biosensing Techniques↗

Rapid screening of small ligand affinity to human serum albumin by an optical biosensor.

Here we report the use of IAsys biosensor technology for determining the binding parameters of low molecular weight compounds, such as warfarin and bilirubin, to surface immobilized human serum albumin. The protein was covalently immobilized on the surface of the biosensor cuvette, bearing a carboxymethyl dextran layer, through a condensing reaction between the carboxyl groups of the biosensor surface and epsilon-amine groups of protein lysine residues. This system detects and quantifies the changes in refractive index in the vicinity of the surface of the sensor chip to which the protein is immobilized. The changes in the refractive index are proportional to the change in the absorbed mass, thus the analysis allows the monitoring of the interaction process and the determination of the binding parameters. Optical biosensor analysis, most suited for studying protein/protein or protein/nucleic acid interactions, was sensitive enough to monitor the binding of low molecular weight compounds to human serum albumin and then suitable for a rapid screening of libraries of potential drugs when bioavailability is the research target.

Bilirubin↗

Determination of hydrogen peroxide in disinfectant solutions using a biosensor with two antagonist enzymes.

The development and characterisation of a new biosensor for hydroperoxides is described, which is obtained by combining an oxygen gas diffusion amperometric electrode and two immobilized enzymes (peroxidase and tyrosinase) working in parallel and competing for the same substrate (catechol). The response of the biosensor to several hydroperoxides was investigated (LOD=0.5.10(-4) M for hydrogen peroxide). It was experimentally found that the biosensor is able to respond also to aqueous solutions of ionic peroxides (LOD=0.2.10(-4) M for potassium peroxidisulphate). The biosensor was applied to the determination of the hydrogen peroxide content of pharmaceutical products, i.e. aqueous disinfectant solutions (RSD% < or =0.5; recoveries by standard addition method between 96.0 and 98.5%).

Biosensing Techniques↗

Materials and techniques for electrochemical biosensor design and construction.

New developments in biosensor design are appearing at a high rate as these devices play increasingly important roles in daily life. This review aims to highlight recent developments in materials and techniques for electrochemical biosensor design and construction. Rapid growth in biomaterials, especially the availability and application of a vast range of polymers and copolymers associated with new sensing techniques have led to remarkable innovation in the design and construction of biosensors, significant improvements in sensor function and the emergence of new types of biosensor. Nevertheless, in vivo applications remain limited by functional deterioration due to surface fouling by biological components. However, new copolymers based upon biomembrane mimicry have been extensively investigated during the last two decades, raising hopes that the problems related to interactions between foreign surfaces and biological fluids and tissues may soon be solved.

Biocompatible Materials↗

Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films.

An interference and cross-talk free dual electrode amperometric biosensor integrated with a microdialysis sampling system is described, for simultaneous monitoring of glucose and lactate by flow injection analysis. The biosensor is based on a conventional thin layer flow-through cell equipped with a Pt dual electrode (parallel configuration). Each Pt disk was modified by a composite bilayer consisting of an electrosynthesised overoxidized polypyrrole (PPYox) anti-interference membrane covered by an enzyme entrapping gel, obtained by glutaraldehyde co-crosslinking of glucose oxidase or lactate oxidase with bovine serum albumin. The advantages of covalent immobilization techniques were coupled with the excellent interference-rejection capabilities of PPYox. Ascorbate, cysteine, urate and paracetamol produced lactate or glucose bias in the low micromolar range; their responses were, however, completely suppressed when the sample was injected through the microdialysis unit. Under these operational conditions the flow injection responses for glucose and lactate were linear up to 100 and 20 mM with typical sensitivities of 9.9 (+/- 0.1) and 7.2 (+/- 0.1) nA/mM. respectively. The shelf-lifetime of the biosensor was at least 2 months. The potential of the described biosensor was demonstrated by the simultaneous determination of lactate and glucose in untreated tomato juice samples; results were in good agreement with those of a reference method.

Animals↗

A two-cell biosensor that couples neuronal cells to optically monitored fish chromatophores.

A two-cell biosensor was developed that uses optically detected changes in naturally colored fish chromatophores to measure the neurosecretory output of mammalian neuronal cells. The specific version of the biosensor described here is a continuous flow device that places red-pigmented, dendritic erythrophore cells directly downstream of an immobilized population of PC12 neuronal cells, a well-established model cell-line having neuroendocrine function. Agents known to stimulate catecholamine neurosecretion (secretagogues) were presented to the PC12 cells. It was found that the varying level of neurosecretion from the PC12 cells was measurable by judging the degree of pigment aggregation in the erythrophores. Increases in catecholamine secretion and consequent pigment aggregation were observed for several known secretagogues, including receptor agonists (ATP, acetylcholine), membrane depolarizing agents (high K(+) concentration), and specific neurotoxins (black widow spider venom, alpha-latrotoxin). This particular two-cell biosensor, which is applicable to the detection of any agents that affect the levels of catecholamine secretion from PC12 cells, demonstrates the general principle that the breadth of sensitivity of a biosensor is increased by employing coupled cell types.

Adenosine Triphosphate↗

Design and demonstration of an automated cell-based biosensor.

Cell-based biosensors have the capacity to respond to a wide range of analytes in a physiologically relevant manner and appear well-suited for toxicity monitoring of both known and unknown analytes. One means of acquiring cellular functional information for biosensor applications involves extracellular recording from excitable cells, which can generate noninvasive and long-term measurements. Previous work from our laboratory described a prototype portable system capable of high signal-to-noise extracellular recordings, in spite of deficiencies in thermal control, fluidics handling, and absence of data acquisition (DAQ) capability. The present work describes a cell-based biosensor system that incorporates low noise amplifier and filter boards, a two-stage thermal control system with integrated fluidics and a flexible graphical user interface for DAQ and control implemented on a personal computer. Wherever possible, commercial off-the-shelf components have been utilized for system design and fabrication. The system exhibits input-referred noise levels of 5-10 microV(RMS), such that extracellular potentials exceeding 50-60 microV can be readily resolved. In addition, the biosensor system is capable of automated temperature and fluidics control. Flow rates can range from 0-2.5 ml/min, while the cell recording chamber temperature is maintained within a range of 36-37 degrees C. To demonstrate the capability of this system to resolve small extracellular potentials, recordings from embryonic chick cardiac myocytes have been performed.

Action Potentials↗

Cellular biosensors for drug discovery.

Recent advances in cell biology, fluorescent probe chemistry, miniaturization and automation have allowed the use of mammalian cells in a variety of medical and industrial applications. Here we describe the generation of cell-based biosensors, engineered to optically report specific biological activity. Cellular biosensors are comprised of living cells and can be used in various applications, including screening chemical libraries for drug discovery and environmental sensing. Panels of biosensors may also be useful for elucidating the function of novel genes. Here we describe two examples of the construction and use of engineered cell lines as biosensors for drug discovery.

Animals↗

A nano-molar sensitive disposable biosensor for determination of dopamine.

The studies on a nano-molar sensitive disposable biosensor based on the screen-printing basal electrode and the supramolecular assembly of dual mediators, tetramethylbenzidine and ferrocene, by beta-cyclodextrin inclusion complexation have been reported in this paper. This biosensor shows the high quality of analytical performance because of the complexation and the microenvironment in the supramolecular structure. The extracted protein of mushroom, which contains abundant polyphenol oxidase, was immobilized in the membrane of cross-linked cyclodextrin film. This biosensor responds to dopamine with high selectivity and sensitivity. Its response range on the concentration of dopamine is from 1.0 x 10(-9) to 1.0 x 10(-6) M with the detection limit as low as 5.0 x 10(-10) M. The response time reaching to 90% of its steady value is less than 60 s. The biosensor can keep its activity for at least 15 days.

Animals↗

Microbial corrosion monitoring by an amperometric microbial biosensor developed using whole cell of Pseudomonas sp.

A microbial biosensor was developed for monitoring microbiologically influenced corrosion (MIC) of metallic materials in industrial systems. The Pseudomonas sp. isolated from corroded metal surface was immobilized on acetylcellulose membrane and its respiratory activity was estimated by measuring oxygen consumption. The microbial biosensor was used for the measurement of sulfuric acid in a batch culture medium contaminated by microorganisms. A linear relationship between the microbial sensor response and the concentration of sulfuric acid was observed. The response time of biosensor was 5 min and was dependent on the immobilized cell loading of Pseudomonas sp., pH, temperature and corrosive environments. The microbial biosensor response was stable, reproducible and specific for sensing of sulfur oxidizing bacterial activity.

Biosensing Techniques↗

A quartz crystal microbalance cell biosensor: detection of microtubule alterations in living cells at nM nocodazole concentrations.

The quartz crystal microbalance (QCM) was used to create a piezoelectric biosensor utilizing living endothelial cells (ECs) as the biological signal transduction element. ECs adhere to the hydrophilically treated gold QCM surface under growth media containing serum. At 24 h following cell addition, calibration curves were constructed relating the steady state Deltaf and DeltaR shift values observed to the numbers of electronically counted cells requiring trypsinization to be removed from the surface. We then utilized this EC QCM biosensor for the detection of the effect of [nocodazole] on the steady state Deltaf and DeltaR shift values. Nocodazole, a known microtubule binding drug, alters the cytoskeletal properties of living cells. At the doses used in these studies (0.11-15 microM), nocodazole, in a dose dependent fashion, causes the depolymerization of microtubules in living cells. This leads a monolayer of well spread ECs to gradually occupy a smaller area, lose cell to cell contact, exhibit actin stress fibers at the cell periphery and acquire a rounded cell shape. We observed the negative Deltaf shift values and the positive DeltaR shift values to increase significantly in magnitude over a 4-h incubation period following nocodazole addition, in a dose dependent fashion, with a transition midpoint of 900 nM. Fluorescence microscopy of the ECs, fixed on the gold QCM surface and stained for actin, demonstrated that the shape and cytoskeleton of ECs were affected by as little as 330 nM nocodazole. These results indicate that the EC QCM biosensor can be used for the study of EC attachment and to detect EC cytoskeletal alterations. We suggest the potential of this cellular biosensor for the real time identification or screening of all classes of biologically active drugs or biological macromolecules that affect cellular attachment, regardless of their molecular mechanism of action.

Actins↗

Soil biosensor for the detection of PAH toxicity using an immobilized recombinant bacterium and a biosurfactant.

A biosensor for detecting the toxicity of polycylic aromatic hydrocarbons (PAHs) contaminated soil has been successfully constructed using an immobilized recombinant bioluminescent bacterium, GC2 (lac::luxCDABE), which constitutively produces bioluminescence. The biosurfactant, rhamnolipids, was used to extract a model PAH, phenanthrene, and was found to enhance the bioavailability of phenanthrene via an increase in its rate of mass transfer from sorbed soil to the aqueous phase. The monitoring of phenanthrene toxicity was achieved through the measurement of the decrease in bioluminescence when a sample extracted with the biosurfactant was injected into the minibioreactor. The concentrations of phenanthrene in the aqueous phase were found to correlate well with the corresponding toxicity data obtained by using this toxicity biosensor. In addition, it was also found that the addition of glass beads to the agar media enhanced the stability of the immobilized cells. This biosensor system using a biosurfactant may be applied as an in-situ biosensor to detect the toxicity of hydrophobic contaminants in soils and for performance evaluation of PAH degradation in soils.

Biosensing Techniques↗

Enhancement in the sensitivity of a gas biosensor by using an advanced immobilization of a recombinant bioluminescent bacterium.

A genetically engineered bioluminescent bacterium (lac::luxCDABE) was immobilized to develop a whole cell biosensor for the detection of toxic gaseous chemicals. The toxicity of chemicals can be evaluated through the bioluminescent reaction as it reduces in intensity when the cells experience toxic or lethal conditions. This whole cell biosensor was fabricated, using an immobilization technique utilizing solid agar medium, for the measurement of toxicity through direct contact of the cells with the gas. To enhance the sensitivity of the biosenor, glass beads were used and the thickness of the agar layer was reduced. The bioluminescent response was measured using a fiber optic probe connected between the biosensor kit and a luminometer. As sample gaseous toxic chemicals, BTEX (Benzene, Toluene, Ethylbenzene, and Xylene) gases were selected and their vapors were produced by a gas generation system. The concentrations of the gaseous chemicals injected into the chamber were controlled by the time of exposure and were measured using a portable gas chromatograph (Allstech., USA). Additions of glass beads facilitated gas diffusion through the solid medium, making the biosensor more sensitive. In addition, a thinner matrix layer was more advantageous for the detection of gas toxicity.

Bacteria↗

Genetic modification of glucose oxidase for improving performance of an amperometric glucose biosensor.

Glucose oxidase (GOD) was genetically modified by adding a poly-lysine chain at the C-terminal with a peptide linker inserted between the enzyme and poly-lysine chain. The poly-lysine chain was added in order to anchor more electron transfer mediator, ferrocenecarboxylic acid, to GOD for the purpose of improving sensitivity and stability of glucose biosensors. The modified GOD had similar K(m) and K(cat) to those of the wild type enzyme. After interacted with the electron transfer mediator, the modified enzyme retained 90.01% of its native activity, while the commercial GOD and the wild type GOD (Aspergillus niger) retained only 22.43 and 22.17%, respectively. Screen-printed electrodes coated with the modified GOD, wild type yeast-derived GOD or the commercial GOD were tested in glucose solution of different concentrations. Experimental results showed that the biosensor based on the modified GOD gave the largest signal among the three. In addition, the linear range of the biosensor prepared by the modified GOD could extend to 45 mM, while they were about 20 mM for the biosensors based on the wild type yeast-derived enzyme and the commercial enzyme.

Biosensing Techniques↗

Detection of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor.

Previously developed photothermal biosensor was optimised by determining the most suitable enzyme substrate (acetylthiocholine iodide) and the optimal carrier buffer (0.05 M phosphate buffer, pH 8.0). Excitation laser operating at 488 nm and 120 mW power provided the highest biosensor sensitivity. The biosensor was tested for detection of toxic organophosphate and carbamate compounds present in samples of salad, iceberg lettuce, and onion. Sufficient sensitivities to different pesticides (carbofuran, propamocarb, oxydemeton-methyl and parathion-ethyl) were achieved without time-consuming sample preparation procedures. The results show good agreement with the concentrations of pesticides determined with standard GC-MS detection method. The developed photothermal biosensor offers new low cost means to detect low concentrations of pesticides in vegetable samples with high throughput and little or no sample pretreatment.

Biosensing Techniques↗

Bio-smart hydrogels: co-joined molecular recognition and signal transduction in biosensor fabrication and drug delivery.

Two classes of polymers that are currently receiving widespread attention in biosensor development are hydrogels and conducting electroactive polymers. The present study reports on the integration of these two materials to produce electroactive hydrogel composites that physically entrap enzymes within their matrices for biosensor construction and chemically stimulated controlled release. Enhanced biosensing capabilities of these membranes have been demonstrated in the fabrication of glucose, cholesterol and galactose amperometric biosensors. All biosensors displayed extended linear response ranges (10(-5)-10(-2) M), rapid response times (<60 s), retained storage stabilities of up to 1 year, and excellent screening of the physiological interferents ascorbic acid, uric acid, and acetaminophen. When the cross-linked hydrogel components of these composite membranes were prepared with the amine containing dimethylaminoethyl methacrylate monomer the result was polymeric devices that swelled in response to pH changes (neutral to acidic). Entrapment of glucose oxidase within these materials made them glucose-responsive through the formation of gluconic acid. When insulin was co-loaded with glucose oxidase into these "bio-smart" devices, there was a twofold increase in insulin release rate when the devices were immersed in glucose solutions. This demonstrates the potential of such systems to function as a chemically-synthesized artificial pancreas.