PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Effects of an anatomically detailed erector spinae model on L4/L5 disc compression and shear.

Biomechanical models utilized for analysis of tasks that load the lumbar spine often predict the resultant moment, disc compression and sometimes shear. Usually the extensor muscular and ligament forces of the lumbar spine are assumed to act 5 cm posterior to a disc centre of rotation. This study has re-examined the generation and pathways of muscular force transmission within the extensor musculature. The effects on L4/L5 disc compression and shear estimates of an anatomically and biomechanically justifiable range of tissue moment arms, lines of force and force generating capacity of muscle, input to a computer model, have been determined. Results indicated that L4/L5 compression estimates could be reduced by up to 35% when the output from a more realistic anatomical model of the erector spinae muscle group was compared with that from the frequently reported and simplified single muscle equivalent with a 5 cm moment arm. The shear force estimates could be altered from more than 500 N (L4 tending to shear anteriorly on L5) to less than 200 N with L4 tending to shear posteriorly on L5. Using the combination of input variables considered by the authors to be most feasible to estimate compression, a single 'equivalent' extensor soft tissue moment arm of 7.5 rather than 5 cm would be needed to equate the compression. This simplification of course, does not accommodate the shear force estimate problem.

Biomechanical Phenomena↗

Tensile and compressive properties of cancellous bone.

The relationship between the mechanical properties of trabecular bone in tension and compression was investigated by non-destructive testing of the same specimens in tension and compression, followed by random allocation to a destructive test in either tension or compression. There was no difference between Young's modulus in tension and compression, and there was a strong positive correlation between the values (R = 0.97). Strength, ultimate strain and work to failure was significantly higher in tensile testing than in compressive testing.

Adult↗

The effect of test methodology on apparent compressive stiffness of tibiofemoral joint specimens.

Several investigators have analysed the compressive load bearing properties of the knee. Careful review of these force/displacement data showed considerable variation, with some investigators reporting displacements 12-15 x higher than others for nearly identical testing conditions using the same animal model. In this study, we sought to determine if this variability was inherent in the tibiofemoral joint or if differences in experimental methodology explained the variation. Compressive force/displacement curves were obtained from 39 normal canine tibiofemoral specimens mounted in a universal testing machine. Two commonly reported methods of measuring compressive displacement were used simultaneously. The testing machine crosshead displacement was used as one measure of displacement of the joint. The other method consisted of extensometers mounted to bone at the joint line. Resultant joint rotation in the parasagittal plane was also measured. Using either approach, we found comparatively little variation among the 39 specimens tested. However, the crosshead displacement measurements diverged from the extensometer measurements as the compressive load increased. At 770 N, the crosshead measurement was nearly twice the extensometer displacement. Further analysis showed that the compliances differed by a uniform amount. Parasagittal joint rotation, as measured by the extensometers, was minimal--less than one half of one degree. Although our loading fixtures were expected to be rigid under the loads used, these data suggest that the deformation of the bone and loading fixtures was responsible for the differences we observed, and may be responsible for the variation in compressive displacement results among several published studies. A model is presented which uses a simple elastic element to represent this deformation.

Animals↗

Dynamic behavior of a biphasic cartilage model under cyclic compressive loading.

It is well known that dynamic mechanical loads can stimulate the biosynthetic activity of articular cartilage. Studying the mechanical environment of chondrocytes under dynamic loading conditions can help to explain this mechano-biological phenomenon in articular cartilage. In this study, the linear biphasic theory was used to examine the dynamic mechanical behavior of articular cartilage under a cyclic compressive force. We first studied the dynamic confined compression of a cartilage disk as a simplified one-dimensional model and then investigated the role of the relatively impermeable subchondral bone structure on the dynamic behavior of the cartilage extracellular matrix (ECM). Under an assumption of articular cartilage as a biphasic composite structure of a porous elastic solid matrix and interstitial fluid, the porous ECM of the articular cartilage was repeatedly compressed and expanded during the loading-unloading phases of the cyclic compressive force. One interesting finding of this study was the oscillating positive (supra-ambient)-negative (sub-ambient) hydrostatic pressure within the cartilage ECM under cyclic compressive loading. The pattern of the dynamic behavior of the cartilage ECM strongly depended on the loading frequency and the primary diffusion characteristic time, tau d. This finding is consistent with those of previous studies (Guilak et al., 1990 Adv Biomech. ASME, 225-228; Mow et al., 1990, Biomechanics of Diarthrodial Joints, pp. 215-260.

Algorithms↗

The role of cartilage streaming potential, fluid flow and pressure in the stimulation of chondrocyte biosynthesis during dynamic compression.

The effects of streaming potential, fluid flow and hydrostatic pressure on chondrocyte biosynthesis were studied by comparing the spatial profiles of these physical stimuli to the profiles of biosynthesis within cartilage disks subjected to dynamic unconfined compression. The radial streaming potential was measured using compression frequencies and disk sizes relevant to studies of physical modulation of cartilage metabolism; a general analytical solution to the unconfined compression of a poroelastic cylinder with impermeable, rigid, adhesive platens was derived using potential theory. The solution with adhesive platen boundary conditions, using measured values of cartilage material properties, predicted streaming potentials that were much closer to experimental results between 0.001 and 1 Hz than a solution using frictionless platen boundary conditions. The predicted radial profiles of streaming potential gradient and fluid velocity (but not hydrostatic pressure) were similar to the previously reported radial dependence of proteoglycan synthesis induced by dynamic unconfined compression. Changes in stiffness associated with reduction of disk diameter suggested that the relative contributions of collagen and proteoglycans to cartilage mechanical properties may be a function of loading frequency in unconfined compression; such anisotropies may explain the remaining discrepencies between measured stiffness and stiffness predicted by the present model.

Biomechanical Phenomena↗

Distraction and compression loads enhance spine torsional stiffness.

We have assessed the degree to which compression and distraction forces applied to the spine of the magnitude achievable through instrumentation systems increase torsional stiffness, thereby possibly enhancing the environment for arthrodesis. A functional relationship between spine torsional stiffness and axial compression and distraction forces is described. To establish this relationship whole human thoracolumbar spines as well as individual motion segments were tested in torsion under a variety of axial loading conditions consistent with forces applied clinically. These studies indicate that applying axial loads to the whole thoracolumbar spine through the action of compression or distraction increases the stiffness of the spine in torsion. Compression and distraction forces increased the torsional stiffness of thoracic segments, but only compression forces were found to significantly increase the stiffness of lumbar segments. The soft tissue structures of both the anterior and the posterior columns have the ability to increase torsional stiffness with axial loading.

Adult↗

Effect of rib cage or abdomen compression at iso-lung volume on breathing pattern.

In anesthetized rabbits a small compression of the rib cage (RC) caused a marked increase of breathing frequency (f), a marked reduction of expiratory duration (Te), a reduction of inspiratory duration (Ti) and tidal volume (VT), while an equal decrease of lung volume produced by abdominal compression(AC) caused a smaller increase of f and no change of Ti, and a slight increase of VT. Similar results occurred when normal end-expiratory volume was maintained during compression. The phenomena disappeared after bilateral vagotomy, whereas persisted after cordotomy in T1. Similar results occurred in dogs (with the exception that VT decreased during AC), whereas in cats only RC increased f by shortening Te. RC caused a marked increase of discharge in 11 out of 19 irritant receptor fibers, whereas AC caused an increase only in 2. In most of the pulmonary stretch receptor fibers the change of activity produced by compression paralleled the lung volume change. The effects of vagal cooling on Ti, Te and the VT-Ti relationship with and without compression suggest irritant receptors as responsible for the different ventilatory pattern during RC and AC.

Abdomen↗

Cardiac compression in rheumatoid pericarditis.

Rheumatoid pericarditis occurs in approximately one third of rheumatoid arthritis (RA) patients. However, clinically apparent rheumatoid pericarditis is infrequent. The authors found clinical pericarditis in 12 of 960 patients admitted for RA, 5 of whom had manifestations of cardiac compression. These 5 had longer duration of RA, worse functional class, and more extraarticular features than the patients without cardiac compression. Presenting features of cardiac compression included dyspnea, edema, chest pain, and pulsus paradoxus. Treatment of patients with cardiac compression due to rheumatoid pericarditis may include a trial of systemically administered corticosteroids, but this should not delay surgical intervention for impending tamponade. Pericardiocentesis should only be performed as an emergency, life-saving procedure. It may be followed by intrapericardiac injection of corticosteroids, but this does not prevent recurrence. Longer-lasting benefit is obtained by surgical decompression. Two-year mortality in patients with cardiac compression was 100%. The literature on the subject is reviewed.

Adrenal Cortex Hormones↗

Airway compromise secondary to vascular compression in a neonate.

Respiratory distress in the neonate may be due to extrinsic tracheobronchial compression. We recently observed a neonate with left mainstem bronchus obstruction resulting in respiratory distress and mediastinal shift. Initial management required intubation and positive pressure ventilation. Bronchoscopic evaluation demonstrated compression of the proximal left main bronchus. The distal bronchus appeared normal. Bronchography, echocardiography and an MRI of the chest confirmed proximal compression of the bronchus and suggested that the cause was an aneurysmal left pulmonary artery and patent ductus arteriosus. With medical therapy there was resolution of the bronchial compression. Re-evaluation by bronchoscopy and echocardiography revealed a normal left main stem bronchus, a normal left pulmonary artery and a closed ductus arteriosus. This clinical scenario suggests that transient pulmonary hypertension may result in significant airway compression due to the proximity of the left main stem bronchus to the left pulmonary artery.

Aneurysm↗

Post-ischemic neurologic recovery and cerebral blood flow using a compression model of complete "bloodless" cerebral ischemia in dogs.

Complete "bloodless" cerebral ischemia was produced in 14 dogs by increasing intracranial pressure above systolic blood pressure (compression ischemia) for 10 min after the onset of an isoelectric EEG. Six dogs were observed for 48 h post-ischemia to assess neurologic recovery, and in 6 other dogs, acute post-ischemic cerebral blood flow was determined for 2 h. In 2 additional dogs, pre-ischemic and intra-ischemic cerebral blood volume (CBV) was measured using 111In-labeled red blood cells. Compression ischemia resulted in 2 of 6 dogs that were normal at 48 h post-ischemia, 3 dogs had moderate cerebral injury, and 1 dog died. These results were similar to results from previous studies in our laboratory in which complete "stagnant" cerebral ischemia of a comparable duration was produced in dogs using aortic and caval cross-clamping. Restoration of cerebral perfusion pressure following compression ischemia was accompanied by an initial phase of cerebral hyperemia followed by a delayed period of hypoperfusion similar to that observed following stagnant ischemia. The CBV studies in 2 dogs revealed that compression ischemia decreased CBV to 12% and 14% of pre-ischemic control values, respectively. The authors conclude, contrary to previous reports, that compression ischemia, although producing near bloodless ischemia, does not improve the brain's tolerance to ischemia.

Animals↗

Simultaneous active compression-decompression and abdominal binding increase carotid blood flow additively during cardiopulmonary resuscitation (CPR) in pigs.

The effects of adding active compression-decompression and abdominal binding separately or combined to standard compression CPR was tested in a randomized cross-over design during ventricular fibrillation in eight pigs. The flow and pressure effects of the two techniques appeared to be additive with no interference between the two. Carotid blood flow increased 22% with active compression-decompression, 34% with abdominal binding and 59% with the combination compared to flow with standard compression. Peak antegrade carotid flow occurred in early systole with retrograde flow in early diastole and close to zero in late diastole with no profound alterations induced by active decompression or abdominal binding. Abdominal binding increased the intrathoracic pressure during the compression phase as estimated from the esophageal pressure, while active decompression caused a negative esophageal pressure during the decompression phase. Neither active decompression nor abdominal binding caused any changes in the coronary perfusion pressure, nor in the left ventricular transmural pressure except for a rise in mid-diastolic pressure with active decompression.

Animals↗

Effects of various degrees of compression and active decompression on haemodynamics, end-tidal CO2, and ventilation during cardiopulmonary resuscitation of pigs.

UNLABELLED: The effects of various degrees of compression and active decompression during cardiopulmonary resuscitation were tested in a randomized cross-over-design during ventricular fibrillation in eight pigs using an automatic hydraulic chest compression device. Compared with 4/0 (compression/decompression in cm), mean carotid arterial blood flow rose by 60% with 5/0, by 90% with 4/2 and 4/3, and 105% with 5/2. Two cm active decompression increased mean brain and myocardial blood flow by 53% and 37%, respectively, as compared with 4/0. Increasing standard compression from 4 to 5 cm caused no further increase in brain or heart tissue blood flow whether or not combined with active decompression. Tissue blood flow remained unchanged or decreased when active decompression (4/3) caused that 50% of the pigs were lifted from the table due to the force required. Myocardial blood flow was reduced with 5/0 vs. 4/0 despite no reduction in end decompression coronary perfusion pressure ((aortic-right atrial pressure) (CPP), (7 +/- 8 mmHg with 4/0, 14 +/- 11 mmHg with 5/0)(NS)). End decompression CPP increased by 186% with 4/2 vs. 4/0, by 200% with 4/3, and by 300% with 5/2. Endo-tracheal partial pressure of CO2 was significantly increased during the compression phase of active decompression CPR compared with standard CPR. Active decompression CPR generated an significantly increased ventilation compared with standard CPR. CONCLUSION: Carotid and tissue blood flow, ventilation, and CPP increase with 2 cm of active decompression. An attempt to further increase the level of active decompression or increasing the compression depth from 4 to 5 cm did not improve organ blood flow.

Animals↗

X-ray diffraction demonstrates reorientation of collagen fibres in the annulus fibrosus during compression of the intervertebral disc.

The annulus fibrosus of the intervertebral disc is reinforced by tilted collagen fibres. It has been predicted that the tilt angle should increase as the disc was compressed. This prediction has now been confirmed using X-ray diffraction. Diffraction patterns were recorded from the ventral annulus of intact L1/2 rabbit discs during various stages of compression. At each stage the ventral height was measured. Fibre tilts were measured from the diffraction patterns and found to increase as the disc was compressed. For five out of six discs the quantitative dependence of tilt on compressed height was in good agreement with theoretical predictions; the sixth did not compress evenly but an increase in tilt was still observed.

Animals↗

Implementation and evaluation of data compression of MR images.

A full-frame bit-allocation technique of data compression has been implemented using the existing computer facilities of an MR imager. Images reconstructed from compressed data files have been compared with the original image and changes in noise and pixel value measured to evaluate any image degradation introduced by the compression process. A 256 x 256 x 8 bit brain image can be compressed in 20 seconds with a compression ratio of greater than 4:1 without significant loss of information.

Head↗

A multicenter randomized trial comparing a percutaneous collagen hemostasis device with conventional manual compression after diagnostic angiography and angioplasty.

OBJECTIVES: A new percutaneous collagen hemostasis device was compared with conventional compression techniques after diagnostic catheterization and angioplasty. BACKGROUND: Peripheral vascular complications after diagnostic catheterization or more complex interventional procedures, as well as the discomfort of manual compression and prolonged bed rest, represent significant morbidity for invasive cardiac procedures. METHODS: A prospective, multicenter, randomized trial was designed to compare the hemostasis time in minutes and the incidence of vascular complications in patients receiving a vascular hemostasis device with those undergoing conventional compression techniques. RESULTS: After diagnostic catheterization, hemostasis time was significantly less with the vascular hemostasis device than with conventional manual compression (4.1 +/- 2.8 min [n = 90 patients] vs. 17.6 +/- 9.2 min [n = 75], p < 0.0001). This difference was greater in patients undergoing angioplasty and was unrelated to the anticoagulation status (4.3 +/- 3.7 min [n = 71 not receiving heparin], 7.6 +/- 11.6 min [n = 85 receiving heparin], 33.6 +/- 24.2 min [n = 134 control patients not receiving heparin], p < 0.0001 vs. control patients). The time from the start of the procedure to ambulation was slightly less after diagnostic catheterization in patients treated with the device (13.3 +/- 12.1 h vs. 19.2 +/- 17.8 h, p < 0.05). It was also less in patients who underwent angioplasty when the device was used after discontinuation of anticoagulation (23.0 +/- 11.1 h, without heparin), as compared with control compression techniques (32.7 +/- 18.8 h, p < 0.0001). Time to ambulation was even shorter (16.1 +/- 11.1 h, p < 0.0001) in patients in whom the device was placed immediately after angioplasty while they were still fully anticoagulated with a prolonged activated clotting time (336 +/- 85 s). There were no major complications (surgery or transfusion) after diagnostic catheterization and a low incidence of major complications in patients who underwent angioplasty (0.7% in control patients, 1.4% with the device without heparin, 1.2% with the device and heparin, p = NS). After angioplasty, there was a trend toward fewer hematomas when the device was used in the absence of heparin (4.2% vs. 9.7% in control patients, p = 0.14). CONCLUSIONS: A new vascular hemostasis device can significantly reduce the puncture site hemostasis time and the time to ambulation without significantly increasing the risk of peripheral vascular complications. The role of this technology in reducing complications, length of hospital stay and cost remains to be determined.

Aged↗

The ability to perform closed chest compressions in helicopters.

Critically ill patients are often transported by air ambulances. Although these patients are likely to require cardiopulmonary resuscitation (CPR) during transport, the effects of the air medical transport environment on CPR efficacy have never been studied. A manikin model was used to assess the ability of flight nurses to perform effective chest compressions while in flight and when stationery on the helipad. The results demonstrate that flight nurses were able to perform chest compressions as effectively in the in-flight setting as in the stationary setting. Chest c compressions performed in the BK-117 helicopter were as effective as those performed in the control environment, but compressions performed in the BO-105 were significantly less effective than controls. In conclusion, in a manikin model, chest compressions are substandard in the BO-105 helicopter because of the limited space available in the aircraft.

Air Ambulances↗

Abdominal compressions during CPR: hemodynamic effects of altering timing and force.

To determine the optimal method of applying abdominal compressions during cardiopulmonary resuscitation (CPR), 3 levels of pressure (25, 50, and 100 torr) were applied to the abdomen a) continuously and b) as 500 msec pulses at 10 different phases during the CPR cycle in 8 anesthetized dogs. Thoracic aortic (Ao) and right atrial (RA) pressures were measured and PAo-PRA was calculated as the coronary perfusion gradient. A pneumatic piston device provided external chest compression (60/min, 120 lbs, for 50% of the cycle) and ventilation (80% O2, 12/min, at 20cm, H2O). Another identical device provided abdominal compression (AC) via an air-filled bladder. High-pressure (100 torr) AC applied for 500 msec commencing 200 msec prior to chest compression demonstrated the best overall profile, raising mean aortic pressure 26 torr (P less than 0.001) and peak coronary perfusion gradient pressure 17 torr (P less than 0.02) from control values during standard CPR of 58 and 41 torr, respectively. We conclude that applying high-pressure, 500-msec pulses of AC 200 msec before chest compressions significantly improves CPR hemodynamics.

Abdomen↗

Information preserving image compression for archiving NMR images.

This paper presents a result on information preserving compression of NMR images for the archiving purpose. Both Lynch-Davisson coding and linear predictive coding have been studied. For NMR images of 256 x 256 x 12 resolution, the Lynch-Davisson coding with a block size of 64 as applied to prediction error sequences in the Gray code bit planes of each image gave an average compression ratio of 2.3:1 for 14 testing images. The predictive coding with a third order linear predictor and the Huffman encoding of the prediction error gave an average compression ratio of 3.1:1 for 54 images under test, while the maximum compression ratio achieved was 3.8:1. This result is one step further toward the improvement, albeit small, of the information preserving image compression for medical applications.

Algorithms↗