PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Micromechanical oscillators as rapid biosensor for the detection of active growth of Escherichia coli.

A rapid biosensor for the detection of bacterial growth was developed using micromechanical oscillators coated by common nutritive layers. The change in resonance frequency as a function of the increasing mass on a cantilever array forms the basis of the detection scheme. The sensor is able to detect active growth of Escherichia coli cells within 1 h which is significantly faster than any conventional plating method which requires at least 24 h. The growth of E. coli was confirmed by scanning electron microscopy. This new sensing method for the detection of active bacterial growth allows future applications in, e.g., rapid antibiotic susceptibility testing by adding antibiotics to the nutritive layer.

Biosensing Techniques↗

Cytochrome P450 biosensors-a review.

Cytochrome P450 (CYP) is a large family of enzymes containing heme as the active site. Since their discovery and the elucidation of their structure, they have attracted the interest of scientist for many years, particularly due to their catalytic abilities. Since the late 1970s attempts have concentrated on the construction and development of electrochemical sensors. Although sensors based on mediated electron transfer have also been constructed, the direct electron transfer approach has attracted most of the interest. This has enabled the investigation of the electrochemical properties of the various isoforms of CYP. Furthermore, CYP utilized to construct biosensors for the determination of substrates important in environmental monitoring, pharmaceutical industry and clinical practice.

Biosensing Techniques↗

Biosensors for real-time in vivo measurements.

The current status of sensors capable of continuous measurement of analytes in biological media is reviewed. This review containing 173 references deals with devices whose use in single cells, tissue slices, animal models and humans has been demonstrated. In addition to sensors specific for glucose, lactate, glutamate, pyruvate, choline and acetylcholine, insights obtained from monitoring nitric oxide, Na(+), K(+), Ca(2+), and dopamine are presented. Performance criteria for sensor performance are described as is the subject of biosensor calibration. Biocompatibility issues are dealt with in some detail as is the status of continuous blood glucose monitoring in humans.

Biosensing Techniques↗

A commercial whole blood glucose biosensor with a low sensitivity to hematocrit based on an impregnated porous carbon electrode.

Erythrocytes (red blood cells) are a major source of response variation in biosensor electrodes expected to operate in whole blood. Such a blood-to-plasma difference (hematocrit effect) must be minimized for those sensors directed towards the hospital market where wide variations in hematocrit can be seen. Typically, many current glucose sensors demonstrate a decreasing response to the analyte in the presence of increasing hematocrit levels. A sensor electrode for glucose is described which displays a reduced sensitivity to changes in hematocrit. The working electrode comprises a base porous conducting carbon layer, which is impregnated with a mixture including glucose oxidase and a ferrocene redox mediator. The base carbon layer has a void volume of 50%, an average pore diameter of less than 0.1 microm and a thickness of about 20 microm. The interior void volume of the base carbon layer is filled entirely with a substantial proportion of the impregnating mixture such that very little remains on the exterior. The resulting impregnated porous electrode excludes erythrocytes and is consequently capable of operating acceptably in venous, capillary, arterial and neonatal blood over a wide hematocrit range of 20-70%.

Artifacts↗

Chemometric exploration of an amperometric biosensor array for fast determination of wastewater quality.

Four wastewater samples of different treatment qualities; untreated, alarm, alert and normal, from a Swedish chemi-thermo-mechanical pulp mill and pure water were investigated using an amperometric bio-electronic tongue in a batch cell. The aim was to explore enzymatically modified screen-printed amperometric sensors for the discrimination of wastewater quality and to counteract the inherent drift. Seven out of eight platinum electrodes on the array were modified with four different enzymes; tyrosinase, horseradish peroxidase, acetyl cholinesterase and butyryl cholinesterase. At a constant potential the current intensity on each sensor was measured for 200s, 100s before injection and 100s after injection of the sample. The dynamic biosensor response curves from the eight sensors were used for principal component analysis (PCA). A simple baseline and sensitivity correction equivalent to multiplicative drift correction (MDC), using steady state intensities of reference sample (catechol) recordings, was employed. A clear pattern emerged in perfect agreement with prior knowledge of the samples explaining 97% of the variation in the data by two principal components (PCs). The first PC described the treatment quality of the samples and the second PC described the difference between treated and untreated samples. Horseradish peroxidase and pure platinum sensors were found to be the determinant sensors, while the rest did not contribute much to the discrimination. The wastewater samples were characterized by the chemical oxygen demand (COD), biological oxygen demand (BOD), total organic carbon (TOC), inhibition of nitrification, inhibition of respiration and toxicity towards Vibrio fischeri using Microtox, the freshwater alga Pseudokirchneriella subcapita and the freshwater crustacean Daphnia magna.

Algorithms↗

Impact of coenzyme regeneration on the performance of an enzyme-based optical biosensor: a computational study.

A mathematical model of a reagent-less optical sensing scheme composed of an enzymatic reaction coupled to light-controlled photochemical coenzyme regeneration is described. The model is based on previous experimental work describing the regeneration of NADPH from NADP(+) by excited state thionine coupled to the oxidation of isocitrate by isocitrate dehydrogenase. The system is capable of repeated isocitrate measurements without the addition of exogenous coenzyme. The model is simulated using numerical integration to determine the effect of regeneration on the sensor sensitivity, response time and maximum sample throughput rate. Prediction of these effects without a model is difficult due to activation and inhibition of the dehydrogenase by both forms of the coenzyme. The regeneration parameters, including thionine concentration and thionine excitation pattern, are varied to determine optimal sensor conditions to maximize performance. A periodic regeneration approach is found to be superior to a continuous regeneration approach as the former maximizes sensitivity and minimizes response time in most cases. In addition periodic regeneration results in a maximum sample throughput frequency that is achieved at a single optimal thionine level and is independent of the analyte concentration. In contrast the optimal thionine concentration during continuous regeneration varies with the sample analyte concentration. These findings highlight the importance of designing controllable regeneration for dehydrogenase-based optical biosensors.

Biosensing Techniques↗

A novel electrochemical detection method for aptamer biosensors.

A beacon aptamer-based biosensor for the detection of thrombin was developed using electrochemical transduction method. Gold surface was modified with a beacon aptamer covalently linked at 5'-terminus with a linker containing a primary aliphatic amine. Methylene blue (MB) was intercalated into the beacon sequence, and used as an electrochemical marker. When the beacon aptamer immobilized on gold surface encounters thrombin, the hairpin forming beacon aptamer is conformationally changed to release the intercalated MB, resulting a decrease in electrical current intensity in voltamogram. The peak signal of the MB is clearly decreased by the binding of thrombin onto the beacon aptamer. The linear range of the signal was observed between 0 and 50.8 nM of thrombin with 0.999 correlation factor. This method was able to linearly and selectively detect thrombin with a detection limit of 11 nM.

Aptamers, Nucleotide↗

Direct mediatorless electron transport between the monolayer of photosystem II and poly(mercapto-p-benzoquinone) modified gold electrode--new design of biosensor for herbicide detection.

Photosystem II (PSII) modified gold electrodes have been prepared providing mediatorless electron transport on the basis of electrodeposited conductive layer poly-mercapto-p-benzoquinone (polySBQ). Such electrodes are suitable in construction of biosensors for PSII inhibiting herbicides. PolySBQ layer was synthesized on (i) screen-printed gold electrodes and (ii) gold microelctodes in an array on silicon substrate, by electrochemical-oxidation of sulpho-p-benzoquinone (SBQ) at +650 mV versus Ag/AgCl. The basic properties of polySBQ layer were characterized using linear sweep voltammetry and atomic force microscopy (AFM). The typical redox response for quinones was observed. The optimal length of the polymer providing direct electron transfer (DET) was found to be very close to 30 nm. PSII particles isolated from the thermophilic cyanobacteria Synechococcus bigranulatus were physically adsorbed on the polySBQ covered gold electrodes. The generation of photocurrent was observed at E=+250 mV (versus Ag/AgCl) without addition of any mediator. The basic properties of DET were studied. We concluded that: (i) PSII active in DET is immobilized in form of monolayer; (ii) the charge transport from PSII to gold working electrode (AuWE) is fast and dominated by the rate of the enzymatic reaction; (iii) polySBQ layer drains electrons from the Q(A) pocket of the photosystem since the electrode activity is inhibited by specific inhibitor, i.e. diuron (DCMU); (iv) the stability of the photosystem immobilized on gold electrodes by using polySBQ is comparable to the stability of PSII in solution under the same experimental conditions; (v) the inhibition of the photosystem by herbicide DCMU follows the sigmoid dependence; (vi) I(50) as well as limit of detection (LOD) show an improved sensitivity compared to other published biosensing systems using PSII as bioactive part.

Adsorption↗

Amperometric biosensor based on tyrosinase-conjugated polysaccharide hybrid film: selective determination of nanomolar neurotransmitters metabolite of 3,4-dihydroxyphenylacetic acid (DOPAC) in biological fluid.

The amperometric detection of neurotransmitters metabolite of 3,4-dihydroxyphenylacetic acid (DOPAC) was achieved at a tyrosinase-chitosan composite film-modified glassy carbon (GC) electrode. The optimal conditions for the preparation of the biosensor were established. This bio-composite film was characterized by scanning electron microscopy (SEM) and Fourier transformed infrared (FT-IR) spectra, suggesting that chitosan covalently connected to chitosan chains. Electrochemical characterization of the bio-hybrid membrane-covered electrodes were also performed in 0.05 M phosphate buffer solution (pH 6.52) containing neurotransmitters or their derivatives by using cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and amperometry. This simply-prepared protein-polysaccharide hybrid film provides a microenvironment friendly for enzyme loading. The sensor was operated at -0.15 V with a short response time. The current linearly increased with the increasing concentration of DOPAC over the concentration of 6 nM-0.2 mM. The lower detection limit for DOPAC is 3 nM (S/N=3). The sensitivity of the sensor is 40 microA mM(-1). A physiological level of neurotransmitters and their derivatives including dopamine, l-dopa, adrenaline, noradrenaline and homovanillic acid as well as ascorbic acid, uric acid and acetaminophen do not affect the determination of DOPAC.

3,4-Dihydroxyphenylacetic Acid↗

Improved strategy for biosensor-based monitoring of water bodies with diverse organic carbon levels.

To protect water resources and to control the water quality it is necessary to develop fast, sensitive, cost-effective, and easy-to-use analytical systems, which are able to measure a variety of contaminants in water. Monitoring water bodies with various matrices can be very difficult. The diverse organic carbon level in water samples (e.g. river water or seawater) causes problems at common analysis and in particular at immunological methods. Here, we demonstrate a new method to overcome the partly occurring matrix problems at quasi-continuous real-world biosensor monitoring. Therefore, we developed an easy matrix referencing method for our fully automated immunoassays that could be adapted to other applications depending on a similar test-format. The method was developed using a synthetic organic carbon standard, and validated using a diluted turf extract. Results for the ultra-sensitive immunoassay for estrone quantification are shown as example. The developed method was verified using immunoassays for testosterone, progesterone, ethinylestradiol, estradiol, and estriol.

Algorithms↗

Two-dimensional micro-bubble actuator array to enhance the efficiency of molecular beacon based DNA micro-biosensors.

Two-dimensional micro-bubble actuator arrays were developed and studied in detail to enhance the hybridization kinetics of a DNA micro-biosensor. The hybridization between a molecular beacon, a kind of oligonucleotide probe, and its complement was investigated in a millimeter-sized PDMS based reaction chamber, where various 2D micro-heater arrays were distributed on the bottom for micro-bubble generation. The hybridization assay without the micro-bubble actuation revealed that the fluorescence increased fast at the beginning and slowed down after that. However, a uniform fluorescence increase was observed when periodic micro-bubble agitation was introduced in the static hybridization solution. A comparison of hybridization assays with and without micro-bubble agitation revealed that the hybridization time could be effectively shortened by 33% with 10 cycles of micro-bubble agitation from a 2 x 1 bubble actuator array, and by 43% with 10 cycles of micro-bubble agitation from a 2 x 2 bubble actuator array.

Biosensing Techniques↗

Developing a biosensor for estrogens in water samples: study of the real-time response of live cells of the estrogen-sensitive yeast strain RMY/ER-ERE using fluorescence microscopy.

Using a fluorescein di-beta-D-galactopyranoside (FDG) substrate we show that in live cells of an estrogen-sensitive yeast strain RMY/ER-ERE with human estrogen receptor (ERalpha) gene and the lacZ gene which encodes beta-galactosidase, the uptake of 17beta-estradiol (E2) and the subsequent production of beta-galactosidase enzyme occur quite rapidly, with maximal enzyme-catalyzed product formation evident after about 30 min of exposure to E2. This finding which agrees with the well-known rates of enzyme-catalyzed reactions could have implications for shortening the duration of environmental sample screening and monitoring regimes using yeast-based estrogen assays, and the development of biosensors for environmental estrogens to complement quantification methods.

Biological Assay↗

Carbon nanotube/cobalt hexacyanoferrate nanoparticle-biopolymer system for the fabrication of biosensors.

Cobalt hexacyanoferrate nanoparticles (CoNP) can be easily prepared by mixing hexacyanoferrate and cobalt chloride solution at room temperature. The nanoparticles were solubilized in aqueous solution of a biopolymer chitosan (CHIT). With the introduction of carbon nanotubes (CNT), the CoNP-CNT-CHIT system formed shows synergy between CNT and CoNP with the significant improvement of redox activity of CoNP due to the excellent electron-transfer ability of CNT. The CoNP-CNT-CHIT film modified glassy carbon electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. In particular, with the introduction of CNT, it amplified the H2O2 sensitivity by approximately 70 times compared to film of CoNP-CHIT. With the immobilization of glucose oxidase onto the electrode surface using glutaric dialdehyde, a biosensor that responds sensitively to glucose has been constructed. In pH 6.98 phosphate buffer, interference free determination of glucose has been realized at -0.2V versus saturated calomel electrode (SCE) with a linear range from 0.01 to 10 mM and response time<10s. The detection limit was 5 microM glucose (S/N=3).

Biocompatible Materials↗

Automatic fermentation control based on a real-time in situ SIRE biosensor regulated glucose feed.

Monitoring and regulation of fermentations is of a paramount industrial and academic importance in order to keep conditions optimal during the entire process. Established techniques employed today include HPLC and spectrophotometry, which both have the disadvantage that broth samples have to be drawn from the fermentor and that they often require sample pre-treatment. The objectives of this study was to design and evaluate a software controlled automatic real-time SIRE biosensor connected to a glucose feed solution pump for in situ based monitoring and regulation of the glucose concentration during a yeast fermentation process. The maximal frequency for the measuring-regulation cycles was 30/h. A 10 mM mean glucose concentration level was successfully maintained within +/-0.013 mM during 60 min fermentations at various concentrations of yeast (10, 20, 40 and 80g/l). The on/off-regulator used caused some expected fluctuations (oscillations) of the glucose concentration around the mean value (+/-0.12 mM at 10 g/l, +/-0.26 mM at 20 g/l, +/-0.51 mM at 40 g/l, and +/-0.99 mM at 80 g/l). A 7-h fermentation process (10 mM glucose and 20 g/l yeast) was successfully monitored and regulated. The obtained measuring data were found to be 8.5-22.9% lower than data obtained with a commercially available spectrophotometric kit. The difference increased linearly (-0.26 mM/h), during the fermentation process and indicated that some clogging of the in situ positioned probe occurred. The speed and the automatisation adaptability of the presented device suggest advantages compared to established techniques.

Biosensing Techniques↗

Piezoelectric biosensor using olfactory receptor protein expressed in Escherichia coli.

An olfactory receptor protein of C. elegans, ODR-10, was expressed in Escherichia coli as a fusion protein, with GST and 6x His-tag. The expression of the target protein was analyzed by SDS-PAGE and Western blot, and was confirmed to be expressed at the membrane fraction of the host E. coli. The surface of a quartz crystal microbalance (QCM) was coated with crude membrane extracts, containing the expressed receptor protein, and the interaction between the olfactory receptor and various odorant molecules examined. Compared with other odorants, diacetyl (2,3-butanedione), known as a natural ligand for the ODR-10 receptor, interacted most strongly with the expressed protein. Various concentrations of diacetyl were applied to the expressed ODR-10 receptor, and the response of the QCM showed a linear relationship to the logarithmic value of the odorant concentration. This piezoelectric biosensor system, using olfactory receptor proteins expressed in E. coli, can be used in diagnostics, toxic chemical detection and the quality control of food.

Animals↗

Indirect competitive immunoassay for detection of aflatoxin B1 in corn and nut products using the array biosensor.

Because of the potential health risks of aflatoxin B1 (AFB1), it is essential to monitor the level of this mycotoxin in a variety of foods. An indirect competitive immunoassay has been developed using the NRL array biosensor, offering rapid, sensitive detection and quantification of AFB1 in buffer, corn and nut products. AFB1-spiked foods were extracted with methanol and Cy5-anti-AFB1 added to the resulting sample. The extracted sample/antibody mix was passed over a waveguide surface patterned with immobilized AFB1. The resulting fluorescence signal decreased as the concentration of AFB1 in the sample increased. The limit of detection for AFB1 in buffer, 0.3 ng/ml, was found to increase to between 1.5 and 5.1 ng/g and 0.6 and 1.4 ng/g when measured in various corn and nut products, respectively.

Aflatoxin B1↗

Dependence of the response of an amperometric biosensor formed in a micro flow channel on structural and conditional parameters.

Comprehensive analysis of the behavior of an amperometric biosensor incorporated in a micro flow channel was conducted by changing the structural and conditional parameters. The device used in the characterization consisted of a thin-film three-electrode system and a silicone rubber flow channel. An enzyme, glucose oxidase, was immobilized either at the bottom of the silicone rubber flow channel or on the electrode substrate. The flow rate, concentration, position of the immobilized enzyme, and channel height were changed, and the changes in the output current and the conversion efficiency were examined. When the flow rate and/or the channel height decreased, the output current and the conversion efficiency significantly increased. The conversion efficiency also increased by decreasing the concentration. The tendency of the flow dependence was reversed when the position of the immobilized enzyme was changed from the silicone rubber side to the electrode substrate. In addition, the influence of l-ascorbic acid was reduced by placing additional working electrodes in the upper stream. l-Ascorbic acid was eliminated more effectively as the flow rate decreased and the area of the working electrode for elimination increased.

Biosensing Techniques↗

Sensitive determination of ciprofloxacin and norfloxacin in biological fluids using an enzymatic rotating biosensor.

The high sensitivity that can be attained using an enzymatic system and mediated by catechol has been verified by on-line interfacing of a rotating biosensor and continuous-flow/stopped-flow/continuous-flow processing. Horseradish peroxidase, HRP, [EC 1.11.1.7], immobilized on a rotating disk, in the presence of hydrogen peroxide catalyzed the oxidation of catechol, whose back electrochemical reduction was detected on glassy carbon electrode surface at -200mV. Thus, when ciprofloxacin (CF) or norfloxacin (NF) was added to the solution, these piperazine-containing compounds participate in Michael addition reactions with catechol to form the corresponding aminoquinone derivative, decreasing the peak current obtained in proportion with the increase of its concentration. CF was used as the model piperazine-containing compound for the study. The influence of indicator composition on the nature of the analytical response has been assessed through examining the electrochemical properties of three derivatives. Interference by electroactive species (ascorbate, urate, and tyrosine) and other physiological constituents (cysteine, glutathione) has also been assessed.

Biosensing Techniques↗