PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Stress and strain distribution within the intact femur: compression or bending?

The aim of this research was to test the hypothesis that the intact femur is loaded predominately in compression. The study was composed of two parts: a finite element analysis of the intact femur to assess if a compressive stress distribution could be achieved in the diaphyseal region of the femur using physiological muscle and joint contact forces; a simple radiological study to assess the in vivo deflections of the femur during one legged stance. The results of this investigation strongly support the hypothesis that the femur is loaded primarily in compression, and not bending as previously thought. The finite element analysis demonstrated that a compressive stress distribution in the diaphyseal femur can be achieved, producing a stress distribution which appears to be consistent with the femoral cross-sectional geometry. The finite element analysis also predicted that for a compressive load case there would be negligible deflections of the femoral head. The radiological study confirmed this, with no measurable in vivo deflection of the femur occurring during one legged stance.

Adult↗

Variable resolution electromagnetic tomography (VARETA) in evaluation of compression of cerebral arteries due to deep midline brain lesions.

BACKGROUND: Hemispheric tumors produced electroencephalographic (EEG) delta activity mainly due to deafferentation of cerebral cortex. In small, deep midline lesions that compressed cerebral arteries, the most important abnormality should have been in EEG theta band that selectively responded to brain ischemia. Frequency domain-variable resolution electromagnetic tomography (FD-VARETA) has been applied satisfactorily to the study of brain tumors, cerebral infarcts, and brain hemorrhages and was shown to localize areas of hypoperfusion. METHODS: Twelve patients with deep midline lesions compressing different cerebral arteries were studied. Computer tomography (CT) and/or magnetic resonance imaging (MRI) as well as quantitative EEG with source calculation in frequency domain were obtained. Brain electromagnetic tomographies (BETs) were calculated to evaluate localization and extension of functional abnormalities. RESULTS: Ten of twelve cases presented abnormal sources in theta band as main abnormal source. In only two cases was the main source in delta band, but these cases also had abnormal Z values in theta band. In four patients there were only abnormal values in theta range. Sources of abnormal theta activity were observed in regions irrigated by the arteries compressed. CONCLUSIONS: In deep midline lesions, compression of cerebral arteries producing relative ischemia may explain abnormal EEG sources in theta band. Patients with main source in theta band showed vascular compression and some patients exhibited vasogenic edema. Thus, theta might be due to relative ischemia produced by both hypoperfusion and edema. Once again, VARETA has found to be very useful in evaluation of functional abnormalities.

Adult↗

Blood loss after total hip replacement: a prospective randomized study between wound compression and drainage.

A randomized, controlled study compared the effects of wound compression with drainage after primary total hip arthroplasty. In 51 patients, an inflatable cuff was placed over the wound underneath a girdle (System Calmed, Calmed AB, Askim, Sweden). Control patients had wound drainage (n = 54). Preoperative and intraoperative variables did not differ between groups. Total blood loss was calculated using hemoglobin balance; with compression it was 1510 +/- 656 mL (mean +/- SD) and in controls 1695 +/- 712 mL (P = .13). However, less blood was transfused in the compression group (P = .05). Wound infection was seen in 2 patients with compression and in 3 controls. Deep venous thrombosis occurred in 3 controls. Wound discharge was more frequent in controls (19/54 vs 8/51; P = .04). Thus, wound compression had no obvious negative effects and reduced wound discharge and need for transfusion. It may replace drainage after total hip arthroplasty.

Adult↗

Large deformation compression induced crystallinity degradation of conventional and highly crosslinked UHMWPEs.

The effect of a large compressive plastic deformation on the melt temperature (Tm), lamellar thickness, crystallinity, and density of four UHMWPEs (two conventional and two highly crosslinked) was examined. The materials were prepared from a single batch of medical grade GUR 1050 resin (Ticona, Bayport, TX, USA). The two conventional UHMWPEs were as-received (virgin) and gamma radiation sterilized at 30 kGy in a nitrogen atmosphere (radiation sterilized). The two highly crosslinked UHMWPEs were each irradiated at 100 kGy and then post-processed with one of either two thermal treatments: annealing, which was done below the melt transition temperature (Tm), at 110 degrees C for 2h (110 degrees C-annealed); and, remelting, which was done above Tm, at 150 degrees C (150 degrees C-remelted). Differences in changes upon compression between the materials were examined using ANCOVA analyses. The 150 degrees C-remelted material showed a significant change in Tm and lamellar thickness upon compressive plastic deformation whereas the other three UHMWPE materials did not. However, all of the materials showed significantly decreased crystallinity and density upon compressive deformation. The findings of this study support that microstructural evolution during compressive deformation is a function of UHMWPE formulation, as affected by irradiation and post-irradiation heat treatment.

Biocompatible Materials↗

Specific volume and compressibility of human serum albumin-polyanion complexes.

The ultrasound velocimetry, densitometry, and differential scanning calorimetry have been used to study the formation of the complexes between human serum albumin (HSA) and polyanions heparin (HEP) and/or dextran sulfate (DS). The values of the ultrasound velocity and specific volume allowed us to determine the specific adiabatic compressibility, phi(K)/beta(0), which reflects the degree of volume compressibility of the complexes. We showed that in the presence of HEP and DS the adiabatic compressibility of HSA decreases with increasing concentration of polyanions. HEP more strongly interacts with HSA than DS. pH of electrolyte in the range 4.7-8.5 weakly affects the adiabatic compressibility. Changes of compressibility of HSA can be caused by increase of the hydration due to the formation of the HSA-polyanion complexes and due to partial unfolding of HSA. The HSA-polyanion interaction resulted in decrease of phase transition temperature of the protein. This evidences about protein destabilization in the presence of polyanions.

Calorimetry, Differential Scanning↗

Thrombosed vertebral artery aneurysm presenting with hemorrhage and bulbar compression: report of two cases.

Bulbar compression by vertebral artery (VA) aneurysm is extremely rare and only reported in a few cases. We report two cases with thrombosed VA aneurysm compressing medulla oblongata; one presented with bulbar apoplexy hemorrhage and the other with subarachnoid hemorrhage (SAH). A 61-year-old male (case 1) presented with consciousness disturbances, left hemiplegia, and subsequent respiratory arrest. He was subjected to controlled ventilation, and computed tomography (CT) scan showed bulbar hemorrhage. Magnetic resonance imaging (MRI) and digital subtraction angiogram (DSA) revealed fusiform right VA aneurysm with partial thrombosis and bulbar compression. Intra-aneurysmal embolization with Guglielmi detachable coils (GDCs) relieved his clinical symptom including respiratory disturbance. Three months after the onset, he remained moderately disabled. A 76-year-old male (case 2) presented with severe headache and subsequent respiratory disturbance. CT scan on admission showed subarachnoid hemorrhage with acute hydrocephalus. Ventricular drainage rapidly improved consciousness while respiratory disturbance persisted over several days. MRI and DSA suggested spontaneous thrombosis of the right VA dissection with bulbar compression. He showed gradual recovery of his respiration over a week. After ventriculo-peritoneal shunting, he was transferred with moderate disability. These results suggest that the elimination of the pulsatile effect of VA aneurysm adjacent to medulla oblongata can improve symptoms caused by aneurysm-related compression. Early diagnosis and appropriate treatment such as intra-aneurysmal embolization for ameliorating the blood flow inside the aneurysm can relieve mass effect and clinical symptoms.

Aged↗

ECG signal compression by multi-iteration EZW coding for different wavelets and thresholds.

The modified embedded zero-tree wavelet (MEZW) compression algorithm for the one-dimensional signal was originally derived for image compression based on Shapiro's EZW algorithm. It is revealed that the proposed codec is significantly more efficient in compression and in computation than previously proposed ECG compression schemes. The coder also attains exact bit rate control and generates a bit stream progressive in quality or rate. The EZW and MEZW algorithms apply the chosen threshold values or the expressions in order to specify that the significant transformed coefficients are greatly significant. Thus, two different threshold definitions, namely percentage and dyadic thresholds, are used, and they are applied for different wavelet types in biorthogonal and orthogonal classes. In detail, the MEZW and EZW algorithms results are quantitatively compared in terms of the compression ratio (CR) and percentage root mean square difference (PRD). Experiments are carried out on the selected records from the MIT-BIH arrhythmia database and an original ECG signal. It is observed that the MEZW algorithm shows a clear advantage in the CR achieved for a given PRD over the traditional EZW, and it gives better results for the biorthogonal wavelets than the orthogonal wavelets.

Algorithms↗

Compressibility of floating pellets with verapamil hydrochloride coated with dispersion Kollicoat SR 30 D.

The purpose of this study was to work out a method of compression of floating pellets with verapamil hydrochloride (VH) in a dose of 40 mg. It was assumed that this form should reside in the stomach floating for several hours and gradually release the drug in a controlled way. Compression of pellets into tablets, being a modern technological process, is much more perfect than enclosing them in a hard gelatin capsule. Kollicoat SR 30 D was selected for coating. In experiments three plasticizers were examined-propylene glycol, triethyl citrate and dibuthyl sebecate (all at concentration of 10%). It was found that VH release from pellets coated by the films of the same thickness (70 microm), however, containing plasticizers is considerably different. Pellets were prepared by wet granulation of powder mixture, spheronization of the granulated mass and coating of the cores with a sustained release film. Two kinds of cellulose, microcrystalline and powdered, and sodium hydrocarbonate were the main components of pellet core. Proper pellet coating film thickness, ensuring obtaining desirable VH release profile and flotation effect, was defined. X compositions of tablets with pellets were examined in order to obtain formulation, from which VH release would mostly approximate pellets before compressing. The best formulation was evaluated taking into account the effect of compression force an tablet hardness and friability, and pellet agglomeration and flotation. Tablet cross-section photographs were taken confirming necessary coating film thickness preventing their deformation caused by compressing into tablets.

Algorithms↗

The difficulty in the assessment of the compression behaviour of powder mixtures: Double layer tablets versus arithmetic additivity rule.

The weighted arithmetic mean from values of a feature derived from the individual components is often used to calculate the theoretically expected compression behaviour of powder mixtures if no interparticulate interactions between the components occur. Alternatively, simulated and experimental double layer tablets are presented. The suitability of the various methods to serve as a reference for the assessment of the compression behaviour of powder mixtures shall be compared. Narrow and similar sieve fractions of maltitol and metamizol were mixed in various ratios of true volumes. Constant total true volumes of the single substances, powder mixtures, and layered powders of the same composition were compressed on an eccentric tabletting machine to a constant maximum geometric mean punch force. In addition, the compression of double layer tablets was mathematically simulated from the dynamic relative density-force data of the pure materials. At a given momentary force, the relative density of a simulated double layered powder bed is given by the harmonic mean of the relative density values of the pure materials weighted by their true volume fractions. The results show that the total, the net, and the expansion work change indeed almost linearly with the true volume fraction of the components in the double layer tablets, with the consequence that the plasticity index (=net work/total workx100) proceeds non-linearly. The slope of the Heckel plot 'at pressure' and the apparent mean yield pressure obtained from these Heckel data are non-linearly related to the true volume fraction. If the weighted arithmetic mean is used to analyse the compression behaviour of the powder mixtures, results are obtained which are incompatible or even contradictory between interrelated features. On the other hand, the double layer model provides a consistent evaluation. A good agreement between the results of the experimental and the simulated double layer tablets is found.

Algorithms↗

Tensile stresses generated in pharmaceutical tablets by opposing compressive line loads.

The distribution of tensile stress, across the splitting plane, has been investigated for the case when circular and square tablets are subjected to opposing compressive line loads acting in the through thickness direction. This type of loading is referred to in the paper as axial compression. Analytical solutions for the two-dimensional problem of a rectangular strip have been used to investigate the variation of stress in the through thickness direction and to consider the effects of load spreading. Three-dimensional finite element analysis has been used to investigate the variation in stress across the diameter, or breadth, of the tablets. It is shown that the magnitude of the tensile stress varies significantly throughout and that load spreading has an important influence on the stress distribution in the through thickness direction. Experiments have been carried out with microcrystalline cellulose (Avicel PH102) material for circular and square tablets to determine their breaking loads when subjected to axial compression and diametral compression. The experimental results show higher breaking loads for the case of axial compression. It is concluded that the platen contact width must be known in order to evaluate the exact value of the tensile strength of the tablet material when applying this test procedure.

Algorithms↗

Cochlear compression in listeners with moderate sensorineural hearing loss.

Psychophysical estimates of basilar membrane (BM) responses suggest that normal-hearing (NH) listeners exhibit constant compression for tones at the characteristic frequency (CF) across the CF range from 250 to 8000 Hz. The frequency region over which compression occurs is broadest for low CFs. This study investigates the extent that these results differ for three hearing-impaired (HI) listeners with sensorineural hearing loss. Temporal masking curves (TMCs) were measured over a wide range of probe (500-8000 Hz) and masker frequencies (0.5-1.2 times the probe frequency). From these, estimated BM response functions were derived and compared with corresponding functions for NH listeners. Compressive responses for tones both at and below CF occur for the three HI ears across the CF range tested. The maximum amount of compression was uncorrelated with absolute threshold. It was close to normal for two of the three HI ears, but was either slightly (at CFs < or =1000 Hz) or considerably (at CFs > or =4000 Hz) reduced for the third ear. Results are interpreted in terms of the relative damage to inner and outer hair cells affecting each of the HI ears. Alternative interpretations for the results are also discussed, some of which cast doubts on the assumptions of the TMC-based method and other behavioral methods for estimating human BM compression.

Acoustic Stimulation↗

Mechanical compression affecting the thermal-induced conformational stability and denaturation temperature of human fibrinogen.

Thermal-induced conformational stability and changes in denaturation temperature of human fibrinogen (FBG) after different mechanical compressions were investigated by a simultaneous Fourier transform infrared microspectroscopy equipped with thermal analyzer (thermal FTIR microscopic system). The confocal Raman microspectroscopy was also applied to determine the thermal reversibility of solid FBG. FBG powder was pressed on one KBr pellet (1 KBr method) or sealed within two KBr pellets (2 KBr method) by different mechanical compressions. The result indicates that there was no marked difference in the thermal behavior for the solid FBG samples prepared by 1 KBr method in the heating process even under different mechanical compression pressures, in which the thermal-induced denaturation temperatures from native to denatured state were maintained constant at 66-67 degrees C. However, the denaturation temperature for the solid FBG samples prepared by 2 KBr method was shifted from 55 to 62 degrees C with the increase of mechanical compression pressure. A good linear correlation was also found between the denaturation temperature and mechanical compression pressure for FBG samples prepared by 2 KBr method. The solid FBG sample, whether prepared by 1 KBr or 2 KBr method, was also found to show the thermal-irreversible property.

Bromides↗

Compression of pellets coated with various aqueous polymer dispersions.

Pellets coated with a new aqueous polyvinyl acetate dispersion, Kollicoat SR 30 D, could be compressed into tablets without rupture of the coating providing unchanged release profiles. In contrast, the compression of pellets coated with the ethylcellulose dispersion, Aquacoat ECD 30, resulted in rupture of the coating and an increase in drug release. Plasticizer-free Kollicoat SR coatings were too brittle and ruptured during compression. The addition of only 10% w/w triethyl citrate as plasticizer improved the flexibility of the films significantly and allowed compaction of the pellets. The drug release was almost independent of the compression force and the pellet content of the tablets. The inclusion of various tabletting excipients slightly affected the drug release, primarily because of a different disintegration rate of the tablets. The core size of the starting pellets had no influence on the drug release. Pellets coated with the enteric polymer dispersion Kollicoat 30 D MAE 30 DP [poly(methacrylic acid, ethyl acrylate) 1:1] lost their enteric properties after compression because of the brittle properties of this enteric polymer. Coating of pellets with a mixture of Kollicoat MAE 30 DP and Kollicoat EMM 30 D [poly(ethyl acrylate, methyl methacrylate) 2:1] at a ratio of 70/30 and compaction of the pellets resulted in sufficient enteric properties.

Acrylic Resins↗

Compression and compaction properties of plasticised high molecular weight hydroxypropylmethylcellulose (HPMC) as a hydrophilic matrix carrier.

The compression and compaction properties of plasticised high molecular weight USP2208 HPMC were investigated with the aim of improving tablet formation in HPMC matrices. Experiments were conducted on binary polymer-plasticiser mixtures containing 17 wt.% plasticiser, and on a model hydrophilic matrix formulation. A selection of common plasticisers, propylene glycol (PG) glycerol (GLY), dibutyl sebacate (DBS) and triacetin (TRI), were chosen to provide a range of plasticisation efficiencies. T(g) values of binary mixtures determined by Dynamic Mechanical Thermal Analysis (DMTA) were in rank order PG>GLY>DBS>TRI>unplasticised HPMC. Mean yield pressure, strain rate sensitivity (SRS) and plastic compaction energy were measured during the compression process, and matrix properties were monitored by tensile strength and axial expansion post-compression. Compression of HPMC:PG binary mixtures resulted in a marked reduction in mean yield pressure and a significant increase in SRS, suggesting a classical plasticisation of HPMC analogous to that produced by water. The effect of PG was also reflected in matrix properties. At compression pressures below 70 MPa, compacts had greater tensile strength than those from native polymer, and over the range 35 and 70 MPa, lower plastic compaction values showed that less energy was required to produce the compacts. Axial expansion was also reduced. Above 70 MPa tensile strength was limited to 3 MPa. These results suggest a useful improvement of HPMC compaction and matrix properties by PG plasticisation, with lowering of T(g) resulting in improved deformation and internal bonding. These effects were also detectable in the model formulation containing a minimal polymer content for an HPMC matrix. Other plasticisers were largely ineffective, matrix strength was poor and axial expansion high. The hydrophobic plasticisers (DBS, TRI) reduced yield pressure substantially, but were poor plasticisers and showed compaction mechanisms that could be attributed to phase separation. The effect of different plasticisers suggests that the deformation characteristics of this HPMC in the solid state is dominated by hydroxyl mediated bonding, rather than by hydrophobic interactions between methoxyl-rich regions.

Chemistry, Pharmaceutical↗

Lower limb and abdominal compression bandages prevent progressive orthostatic hypotension in elderly persons: a randomized single-blind controlled study.

OBJECTIVES: This study sought to assess the efficacy of compression bandage of legs and abdomen in preventing hypotension and symptoms. BACKGROUND: Progressive orthostatic hypotension can occur in elderly people during standing. METHODS: Twenty-one patients (70 +/- 11 years) affected by symptomatic progressive orthostatic hypotension underwent 2 tilt-test procedures, with and without elastic bandage of the legs (compression pressure 40 to 60 mm Hg) and of the abdomen (compression pressure 20 to 30 mm Hg) in a randomized crossover fashion. Leg bandage was administered for 10 min and was followed by an additional abdominal bandage for a further 10 min. Symptoms were evaluated by a 7-item Specific Symptom Score (SSS) questionnaire before and after 1 month of therapy with elastic compression stockings of the legs (prescribed in all patients irrespective of the results of the tilt study). RESULTS: In the control arm, systolic blood pressure decreased from 125 +/- 18 mm Hg immediately after tilting to 112 +/- 25 mm Hg after 10 min of sham leg bandage and to 106 +/- 25 mm Hg after 20 min despite the addition of sham abdominal bandage. The corresponding values with active therapy were 129 +/- 19 mm Hg, 127 +/- 17 mm Hg (p = 0.003 vs. control), and 127 +/- 21 mm Hg (p = 0.002 vs. control). In the active arm, 90% of patients remained asymptomatic, versus 53% in the control arm (p = 0.02). During the month before evaluation, the mean SSS score was 35.2 +/- 12.1 with dizziness, weakness, and palpitations accounting for 64% of the total score. The SSS score decreased to 22.5 +/- 11.3 after 1 month of therapy (p = 0.01). CONCLUSIONS: Lower limb compression bandage is effective in avoiding orthostatic systolic blood pressure decrease and in reducing symptoms in elderly patients affected by progressive orthostatic hypotension.

Abdomen↗

Compressive nanomechanics of opposing aggrecan macromolecules.

In this study, we have measured the nanoscale compressive interactions between opposing aggrecan macromolecules in near-physiological conditions, in order to elucidate the molecular origins of tissue-level cartilage biomechanical behavior. Aggrecan molecules from fetal bovine epiphyseal cartilage were chemically end-grafted to planar substrates, standard nanosized atomic force microscopy (AFM) probe tips (R(tip) approximately 50 nm), and larger colloidal probe tips (R(tip) approximately 2.5 microm). To assess normal nanomechanical interaction forces between opposing aggrecan layers, substrates with microcontact printed aggrecan were imaged using contact mode AFM, and aggrecan layer height (and hence deformation) was measured as a function of solution ionic strength (IS) and applied normal load. Then, using high-resolution force spectroscopy, nanoscale compressive forces between opposing aggrecan on the tip and substrate were measured versus tip-substrate separation distance in 0.001-1M NaCl. Nanosized tips enabled measurement of the molecular stiffness of 2-4 aggrecan while colloidal tips probed the nanomechanical properties of larger assemblies (approximately 10(4) molecules). The compressive stiffness of aggrecan was much higher when using a densely packed colloidal tip than the stiffness measured for using the nanosized tip with a few aggrecan, demonstrating the importance of lateral interactions to the normal nanomechanical properties. The measured stress at 0.1M NaCl (near-physiological ionic strength) increased sharply at aggrecan densities under the tip of approximately 40 mg/ml (physiological densities are approximately 20-80 mg/ml), corresponding to an average inter-GAG spacing of 4-5 Debye lengths (4-5 nm); this characteristic spacing is consistent with the onset of significant electrostatic interactions between GAG chains of opposing aggrecan molecules. Comparison of nanomechanical data to the predictions of Poisson-Boltzmann-based models further elucidated the regimes over which electrostatic and nonelectrostatic interactions affect aggrecan stiffness in compression. The most important aspects of this study include: the incorporation of experiments at two different length scales, the use of microcontact printing to enable quantification of aggrecan deformation and the corresponding nanoscale compressive stress vs. strain curve, the use of tips of differing functionality to provide insights into the molecular mechanisms of deformation, and the comparison of experimental data to the predictions of three increasingly refined Poisson-Boltzmann (P-B)-based theoretical models for the electrostatic double layer component of the interaction.

Aggrecans↗

Mechanical response of bovine articular cartilage under dynamic unconfined compression loading at physiological stress levels.

OBJECTIVE: The objective of this study was to characterize the dynamic modulus and compressive strain magnitudes of bovine articular cartilage at physiological compressive stress levels and loading frequencies. DESIGN: Twelve distal femoral cartilage plugs (3mm in diameter) were loaded in a custom apparatus under load control, with a load amplitude up to 40 N and loading frequencies of 0.1, 1, 10 and 40 Hz, resulting in peak Cauchy stress amplitudes of 4.8 MPa (engineering stress 5.7 MPa). RESULTS: The equilibrium Young's modulus under a tare load of 0.4N was 0.49+/-0.10 MPa. In the limit of zero applied stress, the incremental dynamic modulus derived from the slope of the stress-strain curve increased from 14.6+/-6.9 MPa at 0.1 Hz to 28.7+/-7.8 MPa at 40 Hz. At 4 MPa of applied stress, the corresponding increase was from 48.2+/-13.5 MPa at 0.1 Hz to 64.8+/-13.0 MPa at 40 Hz. Peak compressive strain amplitudes varied from 15.8+/-3.4% at 0.1 Hz to 8.7+/-1.8% at 40 Hz. The phase angle decreased from 28.8 degrees +/-6.7 degrees at 0.1 Hz to-0.5 degrees +/-3.8 degrees at 40 Hz. DISCUSSION: These results are representative of the functional properties of articular cartilage under physiological load magnitudes and frequencies. The viscoelasticity and nonlinearity of the tissue helps to maintain the compressive strains below 20% under the physiological compressive stresses achieved in this study. These findings have implications for our understanding of cartilage metabolism and chondrocyte viability under various loading regimes. They also help establish guidelines for cartilage functional tissue engineering studies.

Animals↗

Combined effects of growth factors and static mechanical compression on meniscus explant biosynthesis.

OBJECTIVE: To compare the actions of fibroblast growth factor-basic (bFGF), insulin-like growth factor-I (IGF-I), platelet derived growth factor-AB (PDGF-AB), and transforming growth factor-beta 1 (TGF-beta1) on bovine meniscus tissue explants with and without static mechanical compression. DESIGN: Meniscus tissue explants were cultured in a serum-free environment supplemented with an individual growth factor (1) over a range of concentrations for 4 days, (2) at a single concentration for 2-14 days, and (3) at a single concentration for 4 days coupled with graded levels of static compression. Explants were analyzed for accumulation of newly synthesized proteoglycan and total protein as measured by 35S-sulfate and 3H-proline incorporation, respectively. RESULTS: Over the range of chosen concentrations, TGF-beta1 was the most potent stimulator of both protein and proteoglycan production, whereas bFGF was the least effective stimulator. Over a 2-week period for all four growth factors, the stimulation of proteoglycan production was sustained while there was no stimulation of protein production during this period. The superposition of static mechanical compression inhibited matrix production in the presence of each anabolic factor, with comparable inhibition relative to uncompressed controls for all factors. CONCLUSIONS: The growth factors chosen exhibited an anabolic effect on the meniscus tissue explants, encouraging matrix production and deposition. The addition of static mechanical compression produced comparable relative inhibition of matrix production for each growth factor, suggesting that static compression and growth factors may modulate meniscal fibrochondrocyte biosynthesis via distinct pathways.

Animals↗