PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Rheological properties of PLGA film-based implants: correlation with polymer degradation and SPf66 antimalaric synthetic peptide release.

This paper reports on the rheological properties of poly(D,L-lactic-co-glycolic acid) polymers (PLGA) dispersions used to form films and of the implants prepared by compression of SPf66 antimalaric peptide between several films, before application and during drug release. 25% PLGA (M(w)=48,000Da) dispersions in dichloromethane showed viscous Newtonian behaviour, being easy flowing and adaptable to the moulds. Evolution of viscoelastic properties, polymer molecular weight, and SPf66 release pattern from the implants immersed in various media was evaluated. Oscillatory shear test showed that freshly prepared implants have an elastic modulus, G', greater than the viscous modulus, G", being both practically independent of angular frequency. After 6 weeks immersion in a pH 7.4 phosphate buffer, G' and G" increased in almost one order of magnitude, despite of a significant polymer degradation. Polymer molecular weight decreased slowly during the first 10 days of immersion (a similar pattern was obtained at pHs 2 and 7.4) and then the degradation process accelerated (degradation index on day 7 equals to 0.89, and on day 14 equals to 16.5). SPf66 release profile followed a pattern similar to that of the polymer degradation index. These observations are explained in terms of changes in polymer structure and conformation that happen in the implant.

Absorbable Implants↗

Variations in coupled water, viscoelastic properties, and film thickness of a Mefp-1 protein film during adsorption and cross-linking: a quartz crystal microbalance with dissipation monitoring, ellipsometry, and surface plasmon resonance study.

We have measured the time-resolved adsorption kinetics of the mussel adhesive protein (Mefp-1) on a nonpolar, methyl-terminated (thiolated) gold surface, using three independent techniques: quartz crystal microbalance with dissipation monitoring (QCM-D), surface plasmon resonance, and ellipsometry. The QCM-D and ellipsometry data shows that, after adsorption to saturation of Mefp-1, cross-linking of the protein layer using NaIO4 transforms it from an extended (approximately 20 nm), water-rich, and hydrogel-like state to a much thinner (approximately 5 nm), compact, and less water-rich state. Furthermore, we show how quantitative data about the thickness, shear elastic modulus, and shear viscosity of the protein film can be obtained with the QCM-D technique, even beyond the Sauerbrey regime, if frequency (f) and energy dissipation (D) measurements measured at multiple harmonics are combined with theoretical simulations using a Voight-based viscoelastic model. The modeling result was confirmed by substituting H2O for D2O. As expected, the D2O substitution does not influence the actual adsorption behavior, but resulted in expected differences in the estimated effective density and shear viscosity. These results provide new insight and understanding about the adsorption kinetics and crosslinking behavior of Mefp-1. They also demonstrate how the above three techniques complement each other for biomolecule adsorption studies.

Adsorption↗

Modeling and measuring the elastic properties of an archaeal surface, the sheath of Methanospirillum hungatei, and the implication of methane production.

We describe a technique for probing the elastic properties of biological membranes by using an atomic force microscope (AFM) tip to press the biological material into a groove in a solid surface. A simple model is developed to relate the applied force and observed depression distance to the elastic modulus of the material. A measurement on the proteinaceous sheath of the archaebacterium Methanospirillum hungatei GP1 gave a Young's modulus of 2 x 10(10) to 4 x 10(10) N/m2. The measurements suggested that the maximum sustainable tension in the sheath was 3.5 to 5 N/m. This finding implied a maximum possible internal pressure for the bacterium of between 300 and 400 atm. Since the cell membrane and S-layer (wall) which surround each cell should be freely permeable to methane and since we demonstrate that the sheath undergoes creep (expansion) with pressure increase, it is possible that the sheath acts as a pressure regulator by stretching, allowing the gas to escape only after a certain pressure is reached. This creep would increase the permeability of the sheath to diffusible substances.

Archaea↗

Relationship between ultrasound assessment of arterial wall properties and blood pressure.

Physical properties of an artery can be described in terms of stiffness, distensibility, and compliance. Changes in these properties can predict atherosclerosis disease, but it is necessary to identify an index that is independent of changes in blood pressure. We measured common carotid artery diameter and pulsatile change with an ultrasonic phase-locked, echo-tracking system in 7 subjects whose mean brachial blood pressure had varied 15 mm Hg or more within a month. Patients taking antihypertensive agents were excluded from the study. We measured changes in arterial diameter (n = 41) at least four times during the study period and calculated the pressure-strain elastic modulus (Ep), distensibility coefficient (DC), cross-sectional compliance (CC) and stiffness parameter (beta) from inner diameter, its pulsatile change, and blood pressure. The correlation coefficients of mean blood pressure with each index are as follows: Ep, 0.53; DC, 0.58; CC, 0.63; beta, 0.21. When mean blood pressure increased 1 mm Hg, the change in each index at 100 mm Hg was as follows: Ep, 1.48 +/- 1.30%; DC, -1.05 +/- 0.97%; CC, -0.69 +/- 0.90%; beta, 0.45 +/- 1.11%. Among the four indices that measure the properties of the arterial walls, stiffness parameter beta was the least dependent on blood pressure. Thus, it appears to have usefulness as an index of arterial wall sclerosis.

Aged↗

The effect of dilution on plasma coagulation kinetics determined by thrombelastography is dependent on antithrombin activity and mode of activation.

Hemodilution-associated hypercoagulability has been the focus of several investigations because significant morbidity and mortality have been associated with perioperative thrombophilia. Because most investigations implicate imbalances in procoagulant/anticoagulant activity as the etiology of hemodilution-associated hypercoagulability, we determined the effects of dilution on coagulation kinetics and clot strength with thrombelastography (TEG(R)). Control plasma (+/-celite activation) and antithrombin (AT)-deficient (<10% activity) plasma were diluted 0%, 10%, 20%, and 30% with saline. TEG(R) variables measured included time to clot initiation (reaction time, R), speed of clot propagation (angle, alpha), and clot strength (amplitude, A; or shear elastic modulus, G). Dilution of control plasma (10%-30%) resulted in a significant (P < 0.05) 16% decrease in R values, no change in alpha values, and decrease in A and G values. AT-deficient plasma had significantly smaller R values compared with control, and dilution did not change R values in AT-deficient plasma. Celite activation eliminated dilution-associated changes in R values in control plasma but resulted in linear decreases (R(2) = 0.88-0.96, P < 0.0001) in alpha, A, and G in response to dilution. Thus, our data indirectly support the concept that decreases in AT activity cause dilution-mediated hypercoagulability in plasma. Finally, celite activation permits quantification of dilution with TEG.

Antithrombins↗

Effects of short-term immobilization versus continuous passive motion on the biomechanical and biochemical properties of the rabbit tendon.

Little work has been done on the effect that continuous passive motion (CPM) may have on maintaining the mechanical and biochemical characteristics of tendons deprived of normal load-bearing stimuli. This study compared changes in mechanical properties and collagen concentrations of the tibialis anterior tendon between two groups of rabbits: control animals that received no treatment and experimental animals that received CPM to one ankle and immobilization to the other. Treatment duration was three weeks. Mechanical testing yielded values for elastic modulus, stiffness, stress, strain, and strain energy density at linear and maximum loads. Hydroxyproline concentrations were measured to determine tendon collagen content. Findings indicated that cyclic tensile loading of tendons by CPM lessened the harmful effects of immobilization. Linear load and stress for CPM and control tendons were similar, while the same measures for immobilized tendons were 16% and 25% less than control tendons. Ultimate strength of the control tendons, however, exceeded CPM tendons by 16% and immobilized tendons by 20%. Hydroxyproline levels were comparable for the CPM, control, and immobilized tissues. For a short duration (three weeks), CPM reduced the detrimental effects of immobilization in the tendon, primarily in the linear-load region.

Animals↗

Pulmonary artery smooth muscle activation attenuates arterial dysfunction during acute pulmonary hypertension.

Acute pulmonary hypertension (PH) may arise with or without an increase in vascular smooth muscle (VSM) tone. Our objective was to determine how VSM activation affects both the conduit (CF) and wall buffering (BF) functions of the pulmonary artery (PA) during acute PH states. PA instantaneous flow, pressure, and diameter of six sheep were recorded during normal pressure (CTL) and different states of acute PH: 1) passively induced by PA mechanical occlusion (PPH); 2) actively induced by intravenous administration of phenylephrine (APH); and 3) a combination of both (APPH). To evaluate the direct effect of VSM activation, isobaric (PPH vs. APH) and isometric (CTL vs. APPH) analyses were performed. We calculated the local BF from the elastic (EPD) and viscous (etaPD) indexes as etaPD/EPD and the characteristic impedance (ZC) from pressure and flow to evaluate CF as 1/ZC. We also calculated the absolute and normalized cross-sectional pulsatility (PCS and NPCS, respectively), the dynamic compliance (CDYN), the cross-sectional distensibility (DCS), and the pressure-strain elastic modulus (EP). The isobaric analysis showed increase of CF, BF, and etaPD (P < 0.01) and decrease of EPD (P < 0.05) during APH in respect to PPH (concomitant with isobaric VSM activation-induced vasoconstriction, P < 0.01). The isometric analysis showed increase of E(PD) and etaPD (P < 0.01), nonsignificant difference in BF (even in the presence of a significant mean PA pressure rise, from 14 (SD 6) to 25 (SD 8) mmHg, P < 0.01), and decrease in CF (P < 0.01) during APPH respect to CTL. Mechanical occlusions (PPH and APPH) reduced BF (P < 0.01) and increased EPD (P < 0.05) with regard to their previous steady states (CTL and APH). Nonsignificant differences were found in EPD between PPH and APPH. VSM activation (APH and APPH) increased etaPD (P < 0.01) respect to their previous passive states (CTL and PPH), but no significant differences were found within similar levels of VSM activation. In conclusion, VSM plays a relevant role in main pulmonary artery function during acute pulmonary hypertension, because isobaric vasoconstriction induced by VSM activation improves both BF and CF, mainly due to the increase in etaPD concomitant with the arterial compliance. CDYN and DCS were the more pertinent clinical indexes of arterial elasticity. Additionally, the etaPD-mediated preservation of the BF could be evaluated by the geometric related indexes (PCS and NPCS), which appear to be qualitative markers of arterial wall viscosity status.

Acute Disease↗

Postfailure compressive behavior of tibial trabecular bone in three anatomic directions.

To obtain information describing the postfailure behavior of human proximal tibial trabecular bone, cube specimens of bone were mechanically tested in compression beyond the point of failure. Tests were performed in the three anatomic directions, plots of stress versus strain were obtained, and measures to describe the stress-strain relations before, during, and after failure were defined. These measures included elastic modulus, strength, postfailure slope, strain during maximum stress, and first postfailure minimum stress. For each anatomic direction, analyses were performed to correlate these parameters with ash density. Each of these measures was significantly correlated with ash density at the p < 0.05 level for all test directions, except for postfailure slope, which was correlated in the mediolateral and superior-inferior directions, and strain during maximum stress, which was correlated only in the superior-inferior direction. The data from this study enable trilinear stress-strain relations to be estimated for proximal tibial trabecular bone of various densities, and can serve as a first step toward modeling the behavior of trabecular bone before, during, and after failure.

Adult↗

Hindlimb unloading alters ligament healing.

We investigated the hypothesis that hindlimb unloading inhibits healing in fibrous connective tissue such as ligament. Male rats were assigned to 3- and 7-wk treatment groups with three subgroups each: sham control, ambulatory healing, and hindlimb-suspended healing. Ambulatory and suspended animals underwent surgical rupture of their medial collateral ligaments, whereas sham surgeries were performed on control animals. After 3 or 7 wk, mechanical and/or morphological properties were measured in ligament, muscle, and bone. During mechanical testing, most suspended ligaments failed in the scar region, indicating the greatest impairment was to ligament and not to bone-ligament insertion. Ligament testing revealed significant reductions in maximum force, ultimate stress, elastic modulus, and low-load properties in suspended animals. In addition, femoral mineral density, femoral strength, gastrocnemius mass, and tibialis anterior mass were significantly reduced. Microscopy revealed abnormal scar formation and cell distribution in suspended ligaments with extracellular matrix discontinuities and voids between misaligned, but well-formed, collagen fiber bundles. Hence, stress levels from ambulation appear unnecessary for formation of fiber bundles yet required for collagen to form structurally competent continuous fibers. Results support our hypothesis that hindlimb unloading impairs healing of fibrous connective tissue. In addition, this study provides compelling morphological evidence explaining the altered structure-function relationship in load-deprived healing connective tissue.

Animals↗

Processing and properties of strong and non-rigid calcium phosphate cement.

A calcium phosphate cement (CPC) sets to form hydroxyapatite and has been used in dental and craniofacial applications. However, when CPC was used in periodontal repair, tooth mobility resulted in the fracture and exfoliation of the brittle implants. The aim of this study was to develop CPC-chitosan lactate composites with higher strength and increased strain before failure. It was hypothesized that the incorporation of chitosan lactate would render CPC non-rigid with improved properties. Two-way ANOVA showed significant effects of chitosan lactate and powder:liquid ratio (p < 0.001) on flexural strength, strain-at-peak-load, work-of-fracture, and elastic modulus. At powder:liquid = 2, the strength (mean +/- SD; n = 6) at 20% chitosan lactate was 15.7 +/- 1.3 MPa, higher than 4.9 +/- 1.4 MPa of CPC without chitosan lactate. At powder:liquid = 1, the strain-at-peak-load was 0.2% for CPC without chitosan lactate; it increased to 15.8% for CPC containing 15% chitosan lactate. The work-of-fracture was increased by more than ten times. The novel strong and non-rigid CPC may provide compliance for tooth mobility without fracturing the implant, and may also extend the use of CPC into the repair of larger defects in stress-bearing locations.

Analysis of Variance↗

Intradermal injection of autologous dermal fibroblasts improves wound healing in irradiated skin.

BACKGROUND: Despite its well-recognized benefits in the management of several solid tumors, the use of radiotherapy prior to surgery is associated with a high incidence of significant surgical wound healing complications. Radiation-induced damage to dermal fibroblasts has been proposed as an important cause. We hypothesized that the introduction of normal, unirradiated fibroblasts into previously irradiated skin would enhance healing of the subsequent surgical wound. MATERIALS AND METHODS: Four groups of wounds were examined in female Wistar rats: (1) unirradiated skin (n = 10), (2) irradiated skin injected with tissue culture medium alone (n = 17), (3) irradiated skin injected with autologous dermal fibroblasts (n = 17), and (4) irradiated skin injected with irradiated autologous dermal fibroblasts (n = 7). Wounds were evaluated biomechanically and histologically. RESULTS: The biomechanical values of breaking load, ultimate tensile strength, elastic modulus, and toughness were significantly greater in the irradiated wounds injected with fibroblasts than those injected with medium only. These cell-injected wounds did not perform as well biomechanically as those in unirradiated skin. Irradiating the cells prior to injection resulted in biomechanical results no better than those in medium-injected wounds. CONCLUSIONS: These results demonstrate that injection of normal, unirradiated fibroblasts significantly improves healing of the irradiated surgical wound. These cells are likely better able to respond to the proliferative, migratory, and synthetic demands of the wound healing environment, as injection of irradiated cells has an equivalent effect on healing as injection of medium alone.

Animals↗

Fast setting calcium phosphate-chitosan scaffold: mechanical properties and biocompatibility.

Calcium phosphate cement (CPC) sets in situ to form hydroxyapatite and is highly promising for a wide range of clinical applications. However, its low strength limits its use to only non-stress applications, and its lack of macroporosity hinders cell infiltration, bone ingrowth and implant fixation. The aim of this study was to develop strong and macroporous CPC scaffolds by incorporating chitosan and water-soluble mannitol, and to examine the biocompatibility of the new graft with an osteoblast cell line and an enzymatic assay. Two-way ANOVA identified significant effects on mechanical properties from chitosan reinforcement and powder:liquid ratio (p<0.001). The flexural strength of CPC-chitosan composite at a powder:liquid ratio of 2 was (13.6+/-1.2) MPa, which was significantly higher than (3.2+/-0.6) MPa for CPC control without chitosan (Tukey's at 0.95). At a powder:liquid ratio of 3.5, CPC-chitosan had a strength of (25.3+/-2.9) MPa, which was significantly higher than (10.4+/-1.7) MPa for CPC control. The scaffolds possessed total pore volume fractions ranging from 42.0% to 80.0%, and macroporosity up to 65.5%. At total porosities of 52.2-75.2%, the scaffold had strength and elastic modulus values similar to those of sintered porous hydroxyapatite and cancellous bone. Osteoblast mouse cells (MC3T3-E1) were able to adhere, spread and proliferate on CPC-chitosan specimens. The cells, which ranged from about 20 to 50 microm including the cytoplasmic extensions, infiltrated into the 165-271 microm macropores of the scaffold. In summary, substantial reinforcement and macroporosity were imparted to a moldable, fast-setting, biocompatible, and resorbable hydroxyapatite graft. The highly porous scaffold may facilitate bone ingrowth and implant fixation in vivo. In addition, the two to three times increase in strength may help extend the use of CPC to larger repairs in moderately stress-bearing locations.

Absorbable Implants↗

Mechanical properties of oxygenated red blood cells in sickle cell (HbSS) disease.

Little data exist for the mechanical properties of individual irreversible or reversible sickle cells (ISC and RSC, respectively), nor is the process of ISC formation well understood. For oxygenated ISC and density-fractionated RSC, we have used micropipette techniques to measure cell surface area (SA) and volume (V), membrane shear elastic modulus (mu), time constant for viscoelastic shape recovery (tc), and hence to calculate membrane surface viscosity (eta = mu X tc). Volume loss associated with increasing cell density was accompanied by a proportionately smaller surface area decrease; SA/V ratio thus increased for denser cells, with ISC having the highest values. Membrane area loss by fragmentation must thus be accompanied by an accelerated decrease in cell volume. ISC had relatively rigid membranes (mu 130% above normal controls) and tc close to normal values, so that their effective membrane viscosity was more than double control. RSC had viscoelastic properties close to control, but showed wider variation between sickle cell donors and within samples. Measurements on density-separated RSC showed that, on average, mu was nearly constant, but that tc was longer for the densest cells, with their eta approaching ISC levels. A small subpopulation of RSC were found that had mu close to ISC values. Hypotonically swollen ISC (with internal hemoglobin concentration decreased to normal levels) retained their increased membrane stiffness but had markedly decreased tc, so that their eta approached normal values. The results show that elevated hemoglobin concentration influences the viscoelastic behavior of ISC and RSC, but that an irreversible change in membrane elasticity also occurs for ISC. These data suggest that ISC formation occurs via a two-stage process: (1) accelerated volume loss leading to increased cytoplasmic and effective membrane viscosity; (2) a sharp rise in membrane rigidity, presumably linked to membrane structural alteration.

Adolescent↗

Biomechanical impact of aluminum accumulation on the pre- and post-yield behavior of rat cortical bone.

In order to analyze the effects on whole-bone behavior of aluminum accumulation, 14 rats, aged 90 days, received i.p. doses of 27 mg/day of elemental Al, as Al(OH)3, during 26 weeks, while 14 rats remained as controls. Their femur diaphyses were studied tomographically by peripheral quantitative computed tomography (pQCT) and mechanically tested in bending. The load/deformation curves obtained allowed distinction between effects observed during the linearly elastic (Hookean) and nonlinear (non-Hookean, or plastic) behaviors of bones before and after the yield point, respectively. Treatment reduced the cortical bone mineralization (volumetric bone mineral density [BMD], -2%; P < 0.01), with a negative impact on the bending stiffness (Young's elastic modulus) and the yield stress of cortical bone (-18% and -13%; P < 0.05). Despite the absence of any cortical mass increase (cross-sectional area), improved spatial distribution of cortical tissue concerning anterior-posterior bending stress (cross-sectional moment of inertia, 10%; P < 0.05) occurred through a modulation of modeling drifts. Up to the yield point, neither the structural strength (load supported), the strain, nor the structural stiffness (load/deformation ratio) of the diaphyses were affected. This suggests an adaptive response of bone geometry to the impairment of bone material stiffness. However, Al intoxication significantly reduced the ultimate load and the post-yield fraction of that load (-6% and -27%; P < 0.05). This suggests that the proposed, adaptive response could have improved bone design so as to make it adequate for maintaining a normal pre-yield diaphyseal stiffness and strength according to the bone mechanostat theory, but not so as to provide complete protection of the diaphyseal post-yield (and ultimate) strength. Although a relative inhibition of bone formation could not be discarded, an Al-induced impairment of the bone ability to resist loads beyond the yield point could have caused the unusual disparity observed between effects on bone (elastic) stiffness and (ultimate) strength. In addition, to explain the unusual finding, these results suggest that little-studied microstructural factors (spatial arrangement of elements within the mineralized tissue) affecting the post-yield behavior of cortical bone, regardless of bone mineralization in these and other conditions, ought to be further investigated in specifically designed studies as a novel, promising resource in skeletal research.

Aluminum↗

Visco-elastic deformation of dental porcelain and porcelain-metal compatibility.

A computer simulation using a visco-elastic stress analysis was conducted to clarify the effect of the heating rate on deformation temperature of dental porcelain during firing. In this simulation, the following temperature-dependent factors were incorporated: elastic modulus, viscosity, and coefficient of thermal expansion. The cooling/heating rate dependencies of both the glass-transition temperature and the temperature distribution in the slab were also included. Thermal expansion curves of porcelain with an applied load at various heating rates were computed. Effects of the applied stress and the heating rate on the deformation temperature of porcelain were revealed. The results suggest that the temperature where the incompatibility stress develops in the porcelain-fused-to-metal strips during cooling can be estimated closely from the deformation point of the heating curve of the porcelain with an applied stress of about 1.2 approximately 3.1 MPa. A method for measuring temperature dependence of viscosity as represented by an Arrhenius equation is proposed.

Computer Simulation↗

Transient and residual stresses in dental porcelains as affected by cooling rates.

The development of either transient or residual stress in a slab of dental porcelain during cooling was simulated by use of a super-computer. The temperature dependences of the elastic modulus, the thermal expansion coefficient, and the shear viscosity, and the cooling rate dependence of the glass transition temperature, Tg, were considered in this calculation. Internal stress and viscoelastic creep were computed for several cooling rates. Calculated results display stress profiles which agree reasonably well with reported measured profiles in quenched, tempered glasses. The calculated residual surface stress, sigma, could be fit by the following empirical formula, sigma = kl2(q/q0)n, q is the cooling rate, q0 is a reference cooling rate and l is the half-thickness of the porcelain. The method by which residual stress develops is also discussed. This discussion suggests a method for strengthening of the porcelain by the development of high-compressive residual stress on the surface.

Computer Simulation↗

Fracture properties of composite and glass ionomer dental restorative materials.

The double-torsion technique has been used to determine critical stress intensity factor (K1c) values for a range of composites and glass ionomer cements used in restorative dentistry. From these values and determined elastic modulus (E) and tensile strength (sigma T) values, two other fracture properties: G1c, the critical strain energy release rate and a0, the inherent flaw size, have been evaluated. Glass ionomers have low K1c and high a0 values, coarse particle composites high K1c and high a0 values, microfine materials low K1c and low a0 values and fine particle composites medium to high K1c values and medium to low a0 values. Light curing materials have K1c values according to their group but tend to have lower a0 values than their chemically curing analogues. Glass ionomers have very low G1c values; however, there is no significant difference between the G1c values of the composite groups. The K1c and a0 values have been used to predict relative performance of the materials in highly stressed restorations and wear.

Dental Materials↗

Stiffness, compliance, elasticity and force generation of outer hair cells.

Isolated outer hair cells (OHCs) were partially sucked into especially designed cell capillaries allowing an experimental reconstitution of the cells' electroanatomy. The experimental approach separated the apical from the basolateral parts of the cells thus forming an artificial scala media and scala tympani. Resistance between both was 121 +/- 42 M omega. A sequence of negative and positive pressures was applied to the basal cell pole allowing "pulling" or "pushing" of the sensory cell investigated. The resulting length changes together with the known pressures allowed the estimation of an actual longitudinal compliance of 354 +/- 35 m/N. Following "pulling" OHCs tended to resume their initial shape after the force had ceased to be effective indicating elastic distortions. The calculated elasticity modulus of OHCs amounted to 6.1 +/- 3.4 kN/m2. From this data an actual longitudinal whole cell stiffness of OHCs of 3 x 10(-3) N/m was calculated. Ultrasound scanning of immobilized OHCs identified the cuticular plate (CP) and a central core between CP and basal cell pole as structures contributing to the cells' acoustic stiffness. Changes of the potential differences between the artificial scala media and scala tympani resulted in active length changes following the command voltage with a slope of delta 1/(1 x U) = 0.055 V-1. Assuming the validity of Hooke's law, the force generation associated with the active length changes can be calculated since the compliance is known.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗