PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Development of a compact home health monitor for telemedicine.

A compact and easy-to-use home health monitor was developed. A palm-size health monitor contained a finger probe as sensor unit. In the finger probe, light from a light emitting diode (LED) array was illuminated on a finger nail bed, and transmitted light was measured to obtain photoplethysmography (PPG) signals. Hematocrit, pulse, respiration rate, and saturated oxygen in arterial blood (SpO(2)) were measured simultaneously from PPGs using five different wavelengths: 569, 660, 805, 904, and 975 nm. To predict hematocrit, a dedicated algorithm was used based on scattering theory of red blood cells using these wavelengths. Preliminary clinical tests showed that the achieved percent errors were +/- 8.2% for hematocrit when tested with 549 persons (N = 549). Digital filtering techniques were used to extract respiratory information from a single PPG signal. SpO(2) was predicted on the basis of the ratio of the wavelengths 660 nm and 940 nm. The accuracies were within clinically acceptable errors. In addition, the compact home health monitor included a blood pressure monitoring unit. For convenient and simultaneous measurement with the other previously mentioned signals, blood pressure was measured on a finger. An air cuff was installed on the same finger where PPGs were measured. Achieved mean differences were +/- 3.8 mmHg for systole and +/- 5.1 mmHg for diastole. One can use the palm-size monitor simply by inserting a finger into the home health monitor that is suitable for telemedicine.

Home Care Services↗

Characteristics of urinary incontinence in elderly patients studied by 24-hour monitoring and urodynamic testing.

Characteristics of urinary incontinence have been studied in 100 elderly incontinent patients using invasive video-urodynamics and noninvasive 24-h monitoring of incontinence, fluid intake, voiding and residual urine. Incontinence was of the urge type in 51 patients, including 24 with reduced bladder sensation. Noninvasive 24-h monitoring showed satisfactory reproducibility and high sensitivity (88%) for detecting urine loss. Urodynamically proven urge incontinence, especially in combination with reduced sensation, and recent bacteriuria were associated with severe urine loss on 24-h monitoring. On 24-h monitoring, urine output was significantly larger at night and nocturia was common. In urge incontinence urine loss was predominantly nocturnal and the amount depended significantly on the previous evening's fluid intake and on nocturia. Noninvasive 24-h monitoring showed that post-void residual was common and was often largest in the early morning. It also yielded many free-voiding flow curves. Normal flow curves with small residual urine make dysfunction of voiding itself unlikely. Thus noninvasive monitoring provides information about incontinence and voiding that is suitable for designing intervention and management strategies. Invasive testing may be necessary however to confirm the urodynamic type of incontinence or suspected voiding dysfunction.

Aged↗

A comparison of two ambulatory blood pressure monitors, the Del Mar Avionics Pressurometer IV and the Spacelabs 90202.

The purpose of this study was to evaluate the accuracy of two noninvasive ambulatory blood pressure (BP) monitors, the new Del Mar Avionics Pressurometer IV (PIV) and the second generation Spacelabs 90202. Two sets of comparisons were made between two trained observers and the monitors on 17 normotensive and 28 hypertensive subjects. The result of the first comparison showed that the average difference between observers and the PIV was 1.2/-2.2 mm Hg for systolic and diastolic BP. Comparisons of both monitors to the observers showed differences of 0.9/1.0 mm Hg for the PIV and 0.3/0.8 mm Hg for the 90202 (systolic/diastolic). Correlations between the average observer reading and the monitors over both sets of comparisons ranged from 0.90 (diastolic 90202 vs observer) to 0.98 (systolic PIV vs observer). The percentage of readings within 5 mm Hg between observer and monitor over all comparisons ranged from a low of 68% (90202, systolic and diastolic) to a high of 83% (PIV, diastolic). In general, both devices are satisfactory and reliable machines for ambulatory BP monitoring, but each has a slightly different bias compared to auscultatory readings.

Adult↗

Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy.

BACKGROUND: Intraoperative ischaemia during carotid cross-clamping in patients undergoing carotid endarterectomy (CEA) is a major complication and prompt recognition of insufficient collateral blood supply is crucial. Electroencephalogram (EEG) is believed to be one of the useful forms of monitoring cerebrovascular insufficiency during CEA. The aim of this study was to evaluate the utility of bispectral index (BIS) monitoring, a processed EEG parameter, for the reliable detection of intraoperative cerebral ischaemia during awake CEA. METHODS: We monitored 52 patients continuously with the BIS monitor together with assessment of neurological function (contralateral upper and lower limb strength and the verbal component of the Glasgow Coma Scale for speech) in patients undergoing awake CEA. RESULTS: Overall mean BIS value in all patients was 96 (SD 2.9). In five patients who showed clinical evidence of cortical ischaemia during carotid cross-clamping, there was no change in the original range of BIS values throughout the procedure (96.7 [3.2]). In one patient BIS values decreased to 38 about 5 min after the incision and recovered within the next 10 min. The mean BIS value in the remaining 46 patients who did not develop clinical signs of ischaemia was 95.4 (2.6). Three cases are presented which demonstrate the inability of the BIS monitor to detect cerebral ischaemia. CONCLUSIONS: Lack of correlation of BIS with the signs of cerebral ischaemia during CEA makes it unreliable for detection of cerebrovascular insufficiency. We conclude that awake neurological testing is the preferred method of monitoring in these patients.

Aged↗

Monitoring in the field.

This review looks at the challenges faced when monitoring patients in the field environment. It is considered from the perspective of the UK Defence Medical Services and their experiences over the past 20 yr. The lessons learned are applicable to many other circumstances where a high standard of care, for a large spectrum of patients, is to be delivered in the most inhospitable conditions. The environmental influences on monitoring equipment such as extremes of heat, cold and altitude must be considered and dealt with. Minimal monitoring standards required by professional bodies have to be undertaken, but there is a need to exceed them to compensate for the untoward effects of hostile environments. Patient and machine variables monitored and their relative importance in the field are also explored. Varying field locations are illustrated and the types of monitoring required to care for patients in different areas of field units are discussed. Patient transfers and the particular difficulties encountered in the military context are also reviewed. Undertaking aeromedical evacuation is one of the most challenging environments in the field and the solutions required to undertake it are explored. These considerations are used to propose design requirements necessary to provide appropriate monitoring in all other field conditions. The standards set for carriage of equipment in the air and the testing required allowing compliance with the regulations in force in the UK, are outlined. Finally the importance of practitioner training to undertake these roles in the field is discussed.

Air Ambulances↗

Skin conductance monitoring compared with Bispectral Index to assess emergence from total i.v. anaesthesia using propofol and remifentanil.

BACKGROUND: Arousal after sevoflurane anaesthesia has been detectable by monitoring changes in skin conductance (SC) with similar accuracy as monitoring Bispectral Index (BIS). As SC monitoring detects changes in sympathetic tone, the measurements might be confounded by the sympatholytic properties of propofol, a component of total i.v. anaesthesia (TIVA). Therefore in this study, monitoring of SC during emergence from TIVA was compared with the monitoring of BIS. METHODS: Twenty-five patients undergoing plastic surgery were investigated. The number of fluctuations of SC per second (NFSC), BIS and haemodynamic variables [systolic blood pressure (SBP) and heart rate (HR)] were recorded simultaneously. The performance of the monitoring devices in distinguishing between the clinical states 'steady-state anaesthesia', 'first clinical reaction' and 'extubation' were compared using the method of prediction probability (Pk) calculation. RESULTS: BIS((R)) showed the best performance in distinguishing between 'steady-state anaesthesia' and 'first reaction' (Pk BIS 0.99 vs NFSC 0.80; P<0.01), and 'steady-state anaesthesia' and 'extubation' (Pk BIS) 1.00 vs NFSC 0.91; P<0.05); the time from first change of BIS or NFSC to a first clinical reaction was significantly longer for NFSC (median BIS 135 s vs NFSC 191 s; P<0.05). BIS and NFSC performed better in distinguishing between the investigated clinical states than SBP and HR. CONCLUSIONS: In this study, BIS was found to predict arousal with a higher probability but slower response times than NFSC in patients waking after TIVA.

Adult↗

Detection of spontaneous episodes in post-infarction angina. Comparison between CCU and Holter monitoring.

The objects of this study are: to evaluate the incidence of early post-infarction angina in patients who developed transmural infarction (Q-AMI) or sub-endocardial infarction (no Q-AMI) during hospitalization; to compare data obtained from patients monitored in Coronary Care Unit (CCU) with those obtained from Holter monitoring. The 107 patients under study (55 with Q-AMI and 52 with no Q-AMI) presented the acute event on average 7.4 and 5.1 days after admittance in the CCU, respectively. A history of angina was present in all except 1 patient with Q-AMI and in all with no Q-AMI. After AMI the angina disappeared in 22 of the patients with Q-AMI and in 31 with no Q-AMI, while it continued in 33 and 21 of these patients, respectively. Twenty-one patients underwent ECG recording according to the Holter technique while in CCU, for an average of 4.4 days before and 5.2 days after the onset of AMI. The comparative analysis of the results obtained from the CCU and from Holter monitoring shows that the CCU greatly underestimates the number of ischaemic episodes, even when pain is present (4.5 episodes per patient per day before AMI and 2 after, versus 13.7 and 6.8 with Holter monitoring). The number of ventricular arrhythmias also seemed lower when analysing data from CCU monitoring. These data demonstrate the importance of Holter monitoring, even in patients admitted to a CCU, for a precise evaluation of the ischaemic and arrhythmic phenomena.

Adult↗

Unreliability of conventional visual electrocardiographic monitoring for detection of transient ST segment changes in a coronary care unit.

Visual monitoring at the central station of coronary care units (CCUs) may not adequately assess the presence and frequency of transient asymptomatic ST segment changes in patients with unstable angina. We have performed continuous 24-h electrocardiographic recordings over a total period of 50 days in 10 patients admitted to our CCU with frequent attacks of angina at rest. Over the corresponding period, at the central monitoring station (6 beds), the nursing-staff detected only 31 transient ischaemic episodes (27 with ST elevation, 4 with depression, 9 of which were asymptomatic). By contrast the retrospective analogue analysis of tapes identified 213 ischaemic episodes: 143 with ST elevation (greater than or equal to 0.2 mV) and 70 with ST depression (greater than or equal to 0.2 mV); usual CCU monitoring failed to report changes during 13 episodes (8 with ST elevation, 5 with depression) accompanied by anginal pain. When the tapes were played back in real time on a CCU monitoring scope, a cardiologist (who had the option of interrupting the play-back whenever tired) recognized 48% of the episodes when presented in groups of 4 and randomly positioned on the screen together with 2 other electrocardiographic tracings not related to the study; he recognized 92% of the episodes when only one ECG was presented on the screen. Thus conventional visual monitoring in a CCU considerably underestimates the incidence of transient ischaemic ST segment changes, some of which were accompanied by pain. This low rate of detection is the result of the presentation on the central monitoring station of several ECGs and of fatigue.

Adult↗

Family acceptance of home apnea monitors.

Home monitoring for apnea patients has been called a stressful situation for family members. A 28-item questionnaire was used to ascertain the impact of home monitoring on the families of children with infantile apnea. Forty of 71 families returned the questionnaire. The majority of respondents felt the stress of home monitoring to be minimal (42.5%) to moderate (37.5%). All respondents favored home monitoring with 80% of parents reporting that the monitor had alerted them to at least one significant apnea or bradycardia episode during the first month of use. Half of parents reported more than five significant alarms in the first month of use. Financial hardship on the family was reported to be minimal. A few parents related significant strain on marital and other sibling-parent relationships. Concerns most commonly voiced were mechanical problems (70%), difficulty in locating qualified and willing babysitters (62.5%), and desire for more concrete information from the physician regarding the child's medical problem (40.0%). These results confirm good acceptance of home monitors by the family and offer direction in dealing with the families' primary concerns.

Family↗

Common peroneal nerve stimulation for neuromuscular monitoring: evaluation in awake volunteers and anesthetized patients.

UNLABELLED: The study was conducted in two parts. First, evoked responses to common peroneal nerve stimulation at four electrode positions were tested in 25 awake volunteers. The initial threshold stimulus current (ITS) (minimal current producing dorsiflexion or eversion of the ankle joint and great toe) and the supramaximal stimulus current (SMS) (the point at which further increases in current did not produce increases in twitch tension) were defined. SMS was not reliably achieved using electrodes at each side of the fibular head. However, an exploratory electrode accurately located the nerve and enabled SMS in all volunteers (SMS/ITS = 3.4). Second, 16 anesthetized, paralyzed patients were studied. The common peroneal and ulnar nerves were stimulated simultaneously. Evoked tension was recorded at the adductor pollicis using a force transducer and at the great toe by a blinded observer. Reversal was given when the train-of-four count at the great toe reached four. Onset times were longer, and median posttetanic counts were greater, at the great toe compared with the adductor pollicis. Time from reversal to train-of-four ratio = 0.7 at the adductor pollicis was 207+/-160 s. We conclude that neuromuscular monitoring at the common peroneal nerve was not equivalent to monitoring at the ulnar nerve. IMPLICATIONS: Accurate neuromuscular monitoring is important for patient safety. We studied the accuracy of monitoring at the common peroneal nerve in volunteers and patients. An exploratory electrode accurately located the common peroneal nerve. Monitoring at the common peroneal nerve was not equivalent to monitoring at the ulnar nerve in patients.

Adult↗

Intraoperative monitoring in neuroanesthesia: a national comparison between two surveys in Germany in 1991 and 1997. Scientific Neuroanesthesia Research Group of the German Society of Anesthesia and Intensive Care Medicine.

UNLABELLED: Two surveys initiated by the Neuroanesthesia Research Group of the German Society of Anesthesia and Intensive Care Medicine examined the practice of intraoperative monitoring during intracranial procedures in Germany in 1991 and 1997. Questionnaires were mailed to departments that were registered members of the German Society of Anesthesia and Intensive Care Medicine and that provided neuroanesthesia service on a routine basis in 1991. In 1997, the survey was repeated in the 1991 respondents. In 1991, 68 departments and in 1997, 44 departments returned completed questionnaires, indicating a response rate of 87% for 1991 and of 65% for 1997. Compared with 1991, the standards for monitoring, such as surveillance of oxygenation, ventilation, circulation, and body temperature, were universally applied in adult and pediatric patients in 1997. Overall, there was a 20% increase in neuromuscular blockade monitoring and in the use of electroencephalography and evoked potentials in 1997 compared with 1991. Further brain-specific monitoring was rarely provided in 1997. Overall, jugular venous oximetry was used in 20% and transcranial Doppler ultrasonography in 15% of responding hospitals. To detect venous air embolism in sitting patients, 75% of all responding hospitals used precordial Doppler ultrasonography in both years, whereas transesophageal echocardiography was more often used in 1997 (38%) as compared with 1991 (17%). IMPLICATIONS: Standards of anesthetic monitoring were surveyed in neuroanesthesia in Germany in 1991 and 1997. Central nervous system monitoring was not the standard of practice.

Adult↗

Role of monitoring devices in prevention of anesthetic mishaps: a closed claims analysis.

Anesthesiologist-reviewers examined 1,175 anesthetic-related closed malpractice claims from 17 professional liability insurance companies. The claims were filed between 1974 and 1988. The reviewers were asked to determine if the negative outcome was preventable by proper use of additional monitoring devices available at the time of the review even if not available at the time the incident occurred, and if so, which devices could have been preventative. In 1,097 cases sufficient information was available to make a judgment regarding preventability of the morbidity or mortality by application of additional monitoring devices. It was determined that 31.5% of the negative outcomes could have been prevented by application of additional monitors. Using the insurance industry's scale of 0 (no injury) to 9 (death), the median severity of injury for incidents deemed preventable was 9 compared with 5 for those deemed not preventable (P less than 0.01, scale detailed in text). The severity of injury scores were the same for preventable mishaps occurring during regional or general anesthesia, suggesting that additional monitoring devices may be equally efficacious in preventing serious negative outcomes during either regional or general anesthesia. The judgements or settlements of the incidents judged preventable by additional monitoring were 11 times more costly (P less than 0.01) than those mishaps not judged preventable. The monitors determined by the reviewers to be most useful in mishap prevention were pulse oximetry plus capnometry. Applied together, these two technologies were considered potentially preventative in 93% of the preventable mishaps.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia↗

Does the use of electroencephalographic bispectral index or auditory evoked potential index monitoring facilitate recovery after desflurane anesthesia in the ambulatory setting?

BACKGROUND: Analogous to the Bispectral Index (BIS) monitor, the auditory evoked potential monitor provides an electroencephalographic-derived index (AAI), which is alleged to correlate with the central nervous system depressant effects of anesthetic drugs. This clinical study was designed to test the hypothesis that intraoperative cerebral monitoring guided by either the BIS or the AAI value would facilitate recovery from general anesthesia compared with standard clinical monitoring practices alone in the ambulatory setting. METHODS: Sixty consenting outpatients undergoing gynecologic laparoscopic surgery were randomly assigned to one of three study groups: (1) control (standard practice), (2) BIS guided, or (3) AAI guided. Anesthesia was induced with 1.5-2.5 mg/kg propofol and 1-1.5 microg/kg fentanyl given intravenously. Desflurane, 3%, in combination with 60% nitrous oxide in oxygen was administered for maintenance of general anesthesia. In the control group, the inspired desflurane concentration was varied based on standard clinical signs. In the BIS- and AAI-guided groups, the inspired desflurane concentrations were titrated to maintain BIS and AAI values in targeted ranges of 50-60 and 15-25, respectively. BIS and AAI values, hemodynamic variables, and the end-tidal desflurane concentration were recorded at 5-min intervals during the maintenance period. The emergence times and recovery times to achieve specific clinical endpoints were recorded at 1- to 10-min intervals. The White fast-track and modified Aldrete recovery scores were assessed on arrival in the PACU, and the quality of recovery score was evaluated at the time of discharge home. RESULTS: A positive correlation was found between the AAI and BIS values during the maintenance period. The average BIS and AAI values (mean +/- SD) during the maintenance period were significantly lower in the control group (BIS, 41 +/- 10; AAI, 11 +/- 6) compared with the BIS-guided (BIS, 57 +/- 14; AAI, +/- 11) and AAI-guided (BIS, 55 +/- 12; AAI, 20 +/- 10) groups. The end-tidal desflurane concentration was significantly reduced in the BIS-guided (2.7 +/- 0.9%) and AAI-guided (2.6 +/- 0.9%) groups compared with the control group (3.6 +/- 1.5%). The awakening (eye-opening) and discharge times were significantly shorter in the BIS-guided (7 +/- 3 and 132 +/- 39 min, respectively) and AAI-guided (6 +/- 2 and 128 +/- 39 min, respectively) groups compared with the control group (9 +/- 4 and 195 +/- 57 min, respectively). More importantly, the median [range] quality of recovery scores was significantly higher in the BIS-guided (18 [17-18]) and AAI-guided (18 [17-18]) groups when compared with the control group (16 [10-18]). CONCLUSION: Compared with standard anesthesia monitoring practice, adjunctive use of auditory evoked potential and BIS monitoring can improve titration of desflurane during general anesthesia, leading to an improved recovery profile after ambulatory surgery.

Adult↗

Use of a monitor muscle flap in buried free forearm flap transfer.

The free forearm flap is a reliable and versatile tool in head and neck reconstruction. However, the patency of the microvascular anastomosis is difficult to monitor when the flap is buried in the reconstruction of the esophagus or orbital floor. We used a portion of forearm muscle on a branch of the radial artery and vein as a monitor flap. After the free forearm flap transfer, the monitor muscle flap was placed externally through a small skin incision. Flap viability was assessed by observing the color of the bleeding elicited from the muscle flap. Monitor muscle flaps are raised easily during elevation of the forearm flap. This technique was used successfully in 5 patients. This monitoring method provides a simple and reliable assessment of viability when direct monitoring of the forearm flap is not possible.

Aged↗

Immunologic monitoring of cancer vaccine therapy: results of a workshop sponsored by the Society for Biological Therapy.

The Society for Biological Therapy held a Workshop last fall devoted to immune monitoring for cancer immunotherapy trials. Participants included members of the academic and pharmaceutical communities as well as the National Cancer Institute and the Food and Drug Administration. Discussion focused on the relative merits and appropriate use of various immune monitoring tools. Six breakout groups dealt with assays of T-cell function, serologic and proliferation assays to assess B cell and T helper cell activity, and enzyme-linked immunospot assay, tetramer, cytokine flow cytometry, and reverse transcription polymerase chain reaction assays of T-cell immunity. General conclusions included: (1) future vaccine studies should be designed to determine whether T-cell dysfunction (tumor-specific and nonspecific) correlated with clinical outcome; (2) tetramer-based assays yield quantitative but not functional data (3) enzyme-linked immunospot assays have the lowest limit of detection (4) cytokine flow cytometry have a higher limit of detection than enzyme-linked immunospot assay, but offer the advantages of speed and the ability to identify subsets of reactive cells; (5) antibody tests are simple and accurate and should be incorporated to a greater extent in monitoring plans; (6) proliferation assays are imprecise and should not be emphasized in future studies; (7) the reverse transcription polymerase chain reaction assay is a promising research approach that is not ready for widespread application; and (8)there is a critical need to validate these assays as surrogates for vaccine potency and clinical effect. Current data and opinion support the use of a functional assay like the enzyme-linked immunospot assay or cytokine flow cytometry in combination with a quantitative assay like tetramers for immune monitoring. At present, assays appear to be most useful as measures of vaccine potency. Careful immune monitoring in association with larger scale clinical trials ultimately may enable the correlation of monitoring results with clinical benefit.

Animals↗

Continuous transcutaneous oxygen monitoring in the critically ill neonate. A controlled clinical trial.

Ten neonates with respiratory distress requiring mechanical ventilation and supplemental oxygen were studied during a continuous 24-h period to determine the value of continuous transcutaneous oxygen (PtcO2) monitoring. All 10 infants were continuously monitored during the study with a Clark-type skin electrode (Litton) and 5 of the 10 also had a catheter-tip oxygen electrode in place in the umbilical artery to measure umbilical artery O2 (PuaO2). The results of these two forms of monitoring were not available for the care of the infant during the study period. Hypoxia, as defined by a PO2 of less than 50 torr, occurred for an average of 237 +/- 51 min/24 h from continuous PtcO2 monitoring as compared with 146 +/- 33 min/24 h by estimation from arterial blood gas (PaO2) (p less than 0.05). Hyperoxia, a PO2 of greater than 75 torr, occurred 69 +/- 16 min/24 h in the continuous group and 113 +/- 26 min/24 h from PaO2 estimations. Severe hypoxia, a PO2 of less than 30 torr, was not observed from PaO2 estimations, but was seen for an average 32 +/- 15 min/24 h from the PtcO2 monitoring. These latter differences were not significant. Correlation between PaO2 and PtcO2 values (r = 0.93) was greater than the correlation between PaO2 and PuaO2 (r = 0.81). PtcO2 = 19.7 +/- 0.74 X PuaO2, and the correlation coefficient between PtcO2 and PuaO2 was 0.64. Continuous oxygen monitoring revealed significantly longer periods of hypoxia than that observed from blood gas estimations alone and its use in the low birth weight infant should result in more rational ventilatory therapy and in fewer episodes of hypoxia.

Blood Gas Analysis↗

Volume monitor for mechanical ventilation in the hyperbaric chamber.

Treatment of critically ill patients requiring ventilatory support and hemodynamic monitoring in the hyperbaric medicine department is a frequent occurrence. We provide mechanical ventilation principally with the Penlon Oxford ventilator; however, its simple design lacks volume, rate, and disconnect monitors. Therefore, we combined the ventilator with the Ohmeda volume monitor, a pulmonary function monitor for adult and pediatric use that gives reliable, accurate measurements of tidal volume, rate, and minute ventilation. The Ohmeda unit is easily adaptable to the Penlon ventilator, and may also be used to monitor respiratory function in the spontaneously breathing patient. To our knowledge, this is the only battery-driven monitor on the market that provides rate, volume, apnea, and minute ventilation within the same unit. It should be used as an adjunct to the Penlon Oxford ventilator in the hyperbaric chamber.

Equipment Design↗

Value of routine pressure monitoring system changes after 72 hours of continuous use.

OBJECTIVE: To assess the infection potential of not routinely changing invasive monitoring kits and associated plasticware. DESIGN: A prospective, observational study of microbiological contamination of a cohort of pressure monitoring infusion systems. SETTING: Adult intensive care units in a university tertiary care center. PATIENTS: Patients who had invasively monitored arterial, central venous, or pulmonary artery catheters in place for > or = 96 hrs without a change to the system were entered into the study. INTERVENTIONS: Fluid samples were obtained from the proximal stopcock of the monitoring kits every 24 hrs, beginning with a sample at 72 hrs and continuing until either the plasticware or catheter was changed or discontinued. Fluid samples were placed in tryptic soy broth and spread on blood agar plates within 24 hrs. MEASUREMENTS AND MAIN RESULTS: Of 451 intervals in which the system remained unviolated for > or = 96 hrs except for sampling, no positive cultures were found. Of the 333 monitoring kits/lines in the study, four cultures became positive within 48 hrs of a violation of the system (flush bag change). Positive cultures were obtained from two different patients, one patient having positive fluid cultures from arterial, central venous, and pulmonary arterial kits. This bacterial growth would not have been eliminated with routine system changes as it occurred within a 48-hr timeframe. CONCLUSIONS: Invasive hemodynamic pressure monitoring systems including tubing and plasticware need not be changed routinely as these changes may cause a higher incidence of contamination due to increased violations of the systems.

Adult↗