PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “parameter optimization”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91Linked to original sources

Analysis of myocardial time-activity curves of 123I-heptadecanoic acid. I. Curve fitting.

Myocardial time-activity curves can be described by two or more parameters. To establish the optimal curve fitting method 33 myocardial time-activity curves were analyzed with different curve fitting methods: monoexponential, biexponential and monoexponential plus constant. A background correction was not applied. Biexponential curve fitting resulted in redundancy of parameters. Optimal curve fitting was obtained with monoexponential plus constant. The constant represents the background activity together with the stored radiolabelled lipids and the half-time value represents the wash-out of radioiodide from the myocardium. A strong relation was found between the constant and the half-time value: small errors in the determination of the constant (background activity) resulted in considerable errors of the half-time value. It is concluded that optimal analysis of a myocardial time-activity curve can be performed with a monoexponential plus constant without earlier correction for background activity.

Coronary Disease↗

Efficient new method for extraction and isolation of three flavonoids from Patrinia villosa Juss. by supercritical fluid extraction and high-speed counter-current chromatography.

Supercritical fluid extraction (SFE) of orotinin, orotinin-5-methyl ether and licoagrochalcone B from Patrinia villosa was performed. The optimization of parameters including pressure, temperature, modifier and sample particle size on yield was carried out using an analytical-scale SFE system. The process was then scaled up by 100 times using a preparative SFE system under the optimized conditions of 25 MPa, 45 degrees C, a sample particle size 40-60 mesh and modified CO2 with 20% methanol. The yield of the preparative SFE was 2.82% (crude extract I) and the combined yield of orotinin, orotinin-5-methyl ether and licoagrochalcone B was 0.82 mg/g of dry sample mass. Then the crude extract I was re-dissolved in methanol and methanol soluble fraction (crude extract II, 0.17%) was obtained, which was successfully isolated and separated by a preparative high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (5:6:6:6, v/v/v/v) by increasing the flow-rate of the mobile phase stepwise from 1.0 to 2.0 ml/min after 3 h. The target compounds isolated and purified by HSCCC were analyzed by high performance liquid chromatography. The separation produced total of 38.2 mg of orotinin at 99.2% purity, 19.8 mg of orotinin-5-methyl ether at 98.5% purity and 21.5 mg of licoagrochalcone B at 97.6% purity from 400 mg of the crude extract in a one-step separation. The recoveries of orotinin, orotinin-5-methyl ether and licoagrochalcone B were 91.1, 91.6 and 90.3%, respectively, and the chemical structure identification was carried out by UV, IR, MS, 1H NMR and 13C NMR.

Chromatography, Supercritical Fluid↗

Esophageal incisions repair by CO2 laser soldering.

PURPOSE: This study evaluated the feasibility of fiberoptic CO2 laser soldering for the repair of esophageal injuries under tight temperature feedback control in an animal model. Healing was compared to conventional suture closure. MATERIALS AND METHODS: A CO2 soldering system equipped with infrared transmitting silver halide fibers was used. The soldered tissue temperature was monitored continuously, and laser power was adjusted to provide constant temperature. The procedure was done with 50% bovine serum albumin solder. Longitudinal incisions measuring 8 to 10 mm were made under general anesthesia in the cervical esophagus of 25 rats. Twenty rats (group I) underwent laser tissue bonding; 8 of which were tested in a preliminary study to determine optimal laser parameters. In the remaining 5 rats (group II, controls), closure was performed with 1 layer of 6/0 Vicryl sutures. The rats were sacrificed 2, 3, 4, and 6 weeks postoperatively, and the esophagus was examined histologically. RESULTS: Optimal temperature was found to be 65 to 70 degrees C and optimal exposure time, 150 to 200 seconds. Laser soldering was successful in 9 of the 12 rats (75%) treated under optimal settings; suturing was successful in 4 of the 5 control rats (80%). There were no significant differences between the groups in healing or complication rates. CONCLUSIONS: These results indicate that the CO2 laser soldering technique is a valid option for the correction of esophageal tears or incisions in rats. The confirmation and extension of these findings in further studies with larger animals may ultimately lead to the routine in vivo use of temperature-controlled laser repair for the esophagus and other organs. This method lends itself to endoscopic bonding of tissues.

Animals↗

Adaptive configuring of radial basis function network by hybrid particle swarm algorithm for QSAR studies of organic compounds.

The configuring of a radial basis function network (RBFN) consists of selecting the network parameters (centers and widths in RBF units and weights between the hidden and output layers) and network architecture. The issues of suboptimum and overfitting, however, often occur in RBFN configuring. This paper presented a hybrid particle swarm optimization (HPSO) algorithm to simultaneously search the optimal network structure and parameters involved in the RBFN (HPSORBFN) with an ellipsoidal Gaussian function as a basis function. The continuous version of PSO was used for parameter training, while the modified discrete PSO was employed to determine the appropriate network topology. The proposed HPSORBFN algorithm was applied to modeling the inhibitory activities of substituted bis[(acridine-4-carboxamide)propyl]methylamines to murine P388 leukemia cells and the bioactivities of COX-2 inhibitors. The results were compared with those obtained from RBFNs with the parameters optimized by continuous PSO and by conventionally RBFN training the algorithm for a fixed network topology, indicating that the HPSO was competent for RBFN configuring in that it converged quickly toward the optimal solution and avoided overfitting.

Algorithms↗

Selecting antibacterials for outpatient parenteral antimicrobial therapy : pharmacokinetic-pharmacodynamic considerations.

Some infectious diseases require management with parenteral therapy, although the patient may not need hospitalisation. Consequently, the administration of intravenous antimicrobials in a home or infusion clinic setting has now become commonplace. Outpatient parenteral antimicrobial therapy (OPAT) is considered safe, therapeutically effective and economical. A broad range of infections can be successfully managed with OPAT, although this form of treatment is unnecessary when oral therapy can be used. Many antimicrobials can be employed for OPAT and the choice of agent(s) and regimen should be based upon sound clinical and microbiological evidence. Assessments of cost and convenience should be made subsequent to these primary treatment outcome determinants. When designing an OPAT treatment regimen, the pharmacokinetic and pharmacodynamic characteristics of the individual agents should also be considered. Pharmacokinetics (PK) is the study of the time course of absorption, distribution, metabolism and elimination of drugs (what the body does to the drug). Clinical pharmacokinetic monitoring has been used to overcome the pharmacokinetic variability of antimicrobials and enable individualised dosing regimens that attain desirable antimicrobial serum concentrations. Pharmacodynamics (PD) is the study of the relationship between the serum concentration of a drug and the clinical response observed in a patient (what the drug does to the body). By combining pharmacokinetic properties (peak [C(max)] or trough [C(min)] serum concentrations, half-life, area under the curve) and pharmacodynamic properties (susceptibility results, minimum inhibitory concentrations [MIC] or minimum bactericidal concentrations [MBC], bactericidal or bacteriostatic killing, post-antibiotic effects), unique PK/PD parameters or indices (t > MIC, C(max)/MIC, AUC(24)/MIC) can be defined. Depending on the killing characteristics of a given class of antimicrobials (concentration-dependent or time-dependent), specific PK/PD parameters may predict in vitro bacterial eradication rates and correlate with in vivo microbiologic and clinical cures. An understanding of these principles will enable the clinician to vary dosing schemes and design individualised dosing regimens to achieve optimal PK/PD parameters and potentially improve patient outcomes. This paper will review basic principles of useful PK/PD parameters for various classes of antimicrobials as they may relate to OPAT. In summary, OPAT has become an important treatment option for the management of infectious diseases in the community setting. To optimise treatment course outcomes, pharmacokinetic and pharmacodynamic properties of the individual agents should be carefully considered when designing OPAT treatment regimens.

Ambulatory Care↗

Optimization of radiosurgery treatment planning via mixed integer programming.

An automated optimization algorithm based on mixed integer programming techniques is presented for generating high-quality treatment plans for LINAC radiosurgery treatment. The physical planning in radiosurgery treatment involves selecting among a large collection of beams with different physical parameters an optimal beam configuration (geometries and intensities) to deliver the clinically prescribed radiation dose to the tumor volume while sparing the nearby critical structure and normal tissue. The proposed mixed integer programming models incorporate strict dose restrictions on tumor volume, and constraints on the desired number of beams, isocenters, couch angles, and gantry angles. The model seeks to deliver full prescription dose coverage and uniform radiation dose to the tumor volume while minimizing the excess radiation to the periphery normal tissue. In particular, it ensures that proximal normal tissues receive minimal dose via rapid dose fall-off. Preliminary numerical tests on a single patient case indicate that this approach can produce exceptionally high-quality plans in a fraction of the time required using the procedure currently employed by clinicians. The resulting plans provide highly uniform prescription dose to the tumor volume while drastically reducing the irradiation received by the proximal critical normal tissue.

Aged↗

[Extraction optimization study of flavonoids from Humulus lupulus].

OBJECTIVE: To optimize extracting parameters of flavonoids from Humulus lupulus. METHOD: Based on the single factors test on ethanol concentration, material and solvent ratio, extracting temperature and extracting time, orthogonal test was performed and the best combination was confirmed. RESULT: With the optimized technology, the maximal extracting amount of flavonoids from H. lupulus was 78 mg x g(-1). CONCLUSION: The optimal techniques obtained are 45% ethanol extracting at 60 degrees C with material and solvent ratio 1:25 for 90 min.

Ethanol↗

Chiral stationary phases in HPLC for the stereoselective determination of methadone.

An extensive study of the behavior of three chiral stationary phases (CSP) is presented for the stereoselective determination of methadone. The following chromatographic columns were selected: a cellulose, Chiralcel OJ; a modified cyclodextrin. Cyclobond I 2000 RSP, and a protein, Chiral-AGP. Retention factors, enantioselectivity, efficiency, and resolution were tested by modifying the composition of the mobile phase as well as the temperature. The mechanism for the chiral recognition of methadone on each support was discussed. Optimal chromatographic parameters were obtained for the three supports tested, and methadone enantiomers were separated in less than 20 minutes. The cellulose-based column gave the best resolution, but this CSP was not adapted to clinical analyses of methadone. Under optimized conditions, the cyclodextrin- and protein-based columns allowed an excellent separation of methadone enantiomers, but no interference with the primary metabolite was found only with Chiral-AGP.

Chromatography, High Pressure Liquid↗

Multiple-echo proton spectroscopic imaging using time domain parametric spectral analysis.

A multiple-echo MR spectroscopic imaging (MRSI) method is presented that enables improved metabolite imaging in the presence of local field inhomogeneities and measurement of transverse relaxation parameters. Short echo spacing is used to maximize signal energy from inhomogeneously line-broadened resonances, and time domain parametric spectral analysis of the entire echo train is used to obtain sufficient spectral resolution from the shortened sampling periods. Optimal sequence parameters for 1H MRSI are determined by computer simulation, and performance is compared with conventional single-echo acquisition using phantom studies at a field strength of 4.7 T. A preliminary example for use at 1.5 T is also presented using phantom and human brain MRSI studies. This technique is shown to offer improved performance relative to single-echo MRSI for imaging of metabolites with shortened T2* values due to the presence of local field inhomogeneities. Additional advantages are the intrinsic measurement of metabolite T2 values and determination of metabolite integrals without T2 weighting, thereby facilitating quantitative metabolite imaging.

Aspartic Acid↗

Adapting the dialysis unit to increased hematocrit levels.

Recombinant human erythropoietin (epoetin) therapy had a significant impact on the practice of nephrology before its widespread use in the dialysis arena. Since then, a number of long-term studies have provided physicians with parameters for optimizing therapeutic response and patient outcomes with epoetin therapy. Fears of accelerated hypertension syndromes or increased fistula clotting are recognized as largely unfounded. There is a marked improvement in well-being, as measured by both subjective and objective parameters, as the level of anemia is reduced. Fortunately, epoetin was recognized early as essential therapy in patients on dialysis and thus was reimbursed by the Health Care Financing Administration (HCFA) and other payers, albeit through various methods of payment. Why is it, then, that hematocrit levels are still averaging approximately 30%? Perhaps the basic concern that all practitioners share is the potential for increased morbidity at "higher" hematocrit levels. Increased access clotting was not reported in the recently completed Epogen (Epoetin alfa; Amgen Inc, Thousand Oaks, CA) phase IV postmarketing study. Needle size, however, needs to be considered, because higher blood flow rates accompanied by higher hematocrit levels may lead to increased hemolysis. The venous needle size is especially important in patients who experience large weight gains. It is important to keep these issues in mind as one decides on an appropriate hematocrit level for a given patient. Hull and Eschbach reviewed postdialysis data from patients with naturally occurring high hematocrit levels and found no major changes in hematocrit level, thus alleviating the concern of significant postdialysis inspissation as a common cause for fistula clotting.

Adult↗

Using quality measures to facilitate allele calling in high-throughput genotyping.

Currently, the main limitation in high-throughput microsatellite genotyping is the required manual editing of allele calls. Even though programs for automated allele calling have been available for several years, they have limited capability because accurate data could only be assured by manual inspection of the electropherograms for confirmation. Here we describe the development of a parametric approach to allele call quality control that eliminates much of the time required for manual editing of the data. This approach was implemented in an editing tool, Decode-GT, that works downstream of the allele calling program, TrueAllele (TA). Decode-GT reads the output data from TA, displays the underlying electropherograms for the genotypes, and sorts the allele calls into three categories: good, bad, and ambiguous. It discards the bad calls, accepts the good calls, and suggests that the user inspect the ambiguous calls, thereby reducing dependence on manual editing. For the categorization we use the following parameters: (1) the quality value for each allele call from TrueAllele; (2) the peak height of the alleles; and (3) the size of the peak shift needed to move peaks into the nearest bin. Here we report how we optimized the parameters such that the size of the ambiguous category was minimized, and both the number of miscalled genotypes in the good category and the useable genotypes in the bad category were negligible. This approach reduces the manual editing time and results in <1% miscalls.

Algorithms↗

A comparison of two injection protocols using helical and dynamic acquisitions in CT examinations of the pancreas.

OBJECTIVE: The patterns of pancreatic enhancement and their relation to various injection parameters remain largely unknown. The purpose of this study was twofold: to compare pancreatic enhancement obtained after high and low rates of i.v. injection of contrast medium and to compare image quality between helical and dynamic sequential CT examinations of the pancreas using optimized scanning parameters. SUBJECTS AND METHODS: One hundred patients were randomly allocated to undergo either a helical CT (HC) acquisition after contrast injection at 6 ml/sec or a dynamic sequential CT (DS) acquisition after contrast injection at 2 ml/sec. Both ionic and nonionic contrast material were used in each group. Pancreatic attenuation values were measured on each section in each patient and averaged for each group. Image quality and visualization of anatomic landmarks were scored by two independent reviewers who were blinded to the acquisition technique. RESULTS: Mean pancreatic enhancement was higher in the HC (61 +/- 17 H) than in the DS group (54 +/- 17 H) (p < .05). Peak pancreatic enhancement was similar in the HC (74 +/- 19 H) and DS (74 +/- 17 H) groups. In the HC group, the optimal pancreatic enhancement index was 47% versus 35% for the DS group. The time to peak enhancement was 39 sec in the HC group and 71 sec in the DS group. The optimal scanning interval was 13 sec in the HC group versus 21 sec in the DS group. Image quality was not significantly different between the protocols, but misregistration and motion artifacts were fewer on HC examinations. CONCLUSION: Overall pancreatic enhancement was higher in the HC group, but the faster rate of injection did not increase the peak pancreatic enhancement and decreased the optimal scanning interval (the interval of time during which pancreatic enhancement was greater than 60 H). Image quality was similar with both protocols.

Adult↗

The inverse problem of electrocardiography: a solution in terms of single- and double-layer sources of the epicardial surface.

An approach to the inverse problem of electrocardiography that involves an estimation of the electric potentials (double-layer equivalent sources) on the heart's epicardial surface from the electrocardiographic potentials that are measurable on the body surface has received considerable attention. This report deals with a heretofore unexplored extension of this approach, one that yields, in addition to the electric potentials on the epicardial surface, the normal components of their gradients (single-layer equivalent sources). We show that this formulation has at least three advantages over the formulation in term of epicardial potentials alone: (1) single-layer equivalent sources, which reflect the flow of current across the epicardial surface, are well suited for the imaging of regional ischemia and infarction; (2) the transfer matrix linking the epicardial and body-surface potentials for this formulation is less ill conditioned than that for the formulation in terms of potentials alone; (3) the input vector for inverse calculations consists of spatially filtered (rather that directly measured and therefore noise) body-surface potentials. To establish the feasibility of this new formulation of the inverse problem and to compare it with the formulation in terms of potentials alone, we used a realistically shaped boundary-element model of human torso. By calculating singular values less ill conditioned. We then directly calculated epicardial and body-surface potentials for a single dipole located centrally and for three simultaneously active dipoles located eccentrically in the torso's heart region and used these results to test three methods that are prerequisites of a successful inverse solution: Tikhonov regularization, linearly constrained least squares, and an L-curve method. The feasibility of the new formulation was demonstrated by the fact that the method based on the linearly constrained least squares improved on overregularized Tikhonov solutions over a wide range of regularization parameters, and it yielded solutions that were more accurate than the best-possible Tikhonov solutions. Moreover, the L-curve solution procedure, which requires no a priori information about the solution, yielded slightly underregularized, but accurate, estimates for the optimal regularization parameter and the corresponding best-possible Tikhonov solution. Our results also showed that replacing--in the interest computational economy--quadrature formulas for the planar triangles with various approximate formulas for the nodes of the model reduces the accuracy of the inverse solution.

Electrocardiography↗

Optimum tool handle diameter for a cylinder grip.

The ideal diameter for a tool handle for males and females has been determined using an existing biomechanical model of the hand validated in previous works. The model estimates a 33-mm optimum diameter tool handle for the general population (males and females). When the optimum diameter for a tool handle is selected, the muscles exert the minimum force needed to hold the tool and perform gripping activities. Optimal handle design reduces the force required for gripping a tool, protects the underlying joint structures, and reduces the risk of developing cumulative trauma associated with repetitive task requiring high grip forces and awkward postures. This article provides a design parameter for optimal tool diameter to aid the therapist in the selection of assistive devices, built-up handles, or for the fabrication of a tool handle.

Biomechanical Phenomena↗

Gene expression and antitumor effect following im electroporation delivery of human interferon alpha 2 gene.

AIM: To investigate the gene expression and antitumor effect following im electroporation delivery of human interferon alpha 2 (hIFN-alpha 2) gene. METHODS: The pcD2/hIFN-alpha 2 was injected into the middle of the quadriceps muscle of female BALB/c mice or the leukemia-bearing female BALB/c nude mice, and then electroporation was given to the injection site. Optimal electrical parameters and the efficiency of gene transfer was studied with hIFN-alpha 2 ELISA kit. The HL-60 tumor model in BALB/c nude mice was used to investigate therapeutic effects of im electroporation delivery of pcD2/hIFN-alpha 2. RESULTS: The optimal conditions for the electric pulses were as follows: voltage at 200 V/cm; pulse duration at 40 ms per pulse; number of pulse at 6 pulses and frequency at 1 Hz. Under optimal conditions, the serum hIFN-alpha 2 levels in electroporation group (160 microg/L+/-31 microg/L) were 45-fold higher than those of nonelectroporation group (3.6 microg/L+/-1.6 microg/L, P<0.01). The growth of leukemia was inhibited more obviously and the survival time of the leukemia-bearing nude mice was prolonged after im electroporation delivery of pcD2/hIFN-alpha 2 100 microg or 200 microg. CONCLUSION: Electroporation was an efficient method for the delivery of plasmid DNA and im electroporation delivery of pcD2/hIFN-alpha 2 was effective in treating leukemia.

Animals↗

Estimating structural properties of trabecular bone from gray-level low-resolution images.

In this paper the relationship between three-dimensional histomorphometric parameters derived from microCT and MRI images of distal radius trabecular bone samples is studied. microFE analysis of the trabecular samples is performed and Young's modulus for cranio-caudal direction is calculated. Most of the MRI and microCT parameters correlate significantly with, respectively, MRI and microCT estimates of bone volume fraction. For some of the parameters strong correlation between microCT and MRI results is also observed. However, in these cases there simultaneously exists correlation between: microCT parameter and microCT bone volume fraction; microCT and MRI bone volume fraction; MRI bone volume fraction and MRI parameter. It is found that, comparing to bone volume fraction, histomorphometric information derived from binarized MRI images does not improve estimation of the Young's modulus of trabecular bone samples (calculated for "gold standard" microCT data). Thus a novel method of "optimal paths" analysis of gray-level MRI images is introduced. "Optimal paths" parameters improve estimation of the Young's modulus of trabecular bone samples. They also provide surrogate, gray-level image-based measure of trabecular thickness.

Aged↗

Magnetization transfer imaging in vivo of the rat brain at 4.7 T: interpretation using a binary spin-bath model with a superLorentzian lineshape.

Proton magnetization transfer contrast (MTC) imaging, using continuous wave off-resonance irradiation, was performed on the rat brain in vivo at 4.7 Tesla. The observed MTC was studied in three different brain regions: the corpus callosum, the basal ganglia, and the temporal lobe. By systematically varying the offset frequency and the amplitude of the RF irradiation, the observed signal intensities for each region of interest were modeled using a system including free water and a pool of protons with restricted motions (R. M. Henkelman, X. Huang, Q. Xiang, G. J. Stanisz, SD Swanson, M. J. Bronskill, Magn. Res. Med. 29, 759 (1993)). Most of the relaxation parameters of both proton pools remained fairly constant for the three regions of interest, with a T2 value of about 9 micros for the immobilized protons, whereas the rate of exchange increased significantly from the temporal lobe to the corpus callosum. The optimal acquisition parameters for the improved MTC under steady-state saturation were found to be 2-10 kHz offset frequency and 500-800 Hz RF irradiation amplitude. Conversely, an irradiation amplitude of 3 kHz at an offset frequency of 12 kHz is required to minimize the direct effect of off-resonance irradiation. Such an approach could be extended to human brain imaging with the aim of characterizing tissue-specific disease.

Animals↗

[Dynamics of motor components of optokinetic nystagmus during exposure of the vestibular apparatus to angular accelerations].

The effect of angular accelerations on the optokinetic nystagmus was studied on 25 test subjects using a special vestibulo-optokinetic trainer rotated according to five programs and electrooculography. Angular accelerations were found to induce indirectly changes in the amplitude and time of the optokinetic nystagmus via the vestibular apparatus. Optimization of parameters of the optokinetic nystagmus was reflected in the criterion of positive difference + delta between angular velocities of the slow component of the nystagmus and optokinetic stimuli. It is postulated that the criterion + delta is a necessary factor in the organization of optimal time relations between optokinetic stimuli and central processes that are responsible for the final result--sensory image of movement.

Acceleration↗