PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92Linked to original sources

A finite element model of cell deformation during magnetic bead twisting.

Magnetic twisting cytometry probes mechanical properties of an adherent cell by applying a torque to a magnetic bead that is tightly bound to the cell surface. Here we have used a three-dimensional finite element model of cell deformation to compute the relationships between the applied torque and resulting bead rotation and lateral bead translation. From the analysis, we computed two coefficients that allow the cell elastic modulus to be estimated from measurements of either bead rotation or lateral bead translation, respectively, if the degree of bead embedding and the cell height are known. Although computed strains in proximity of the bead can be large, the relationships between applied torque and bead rotation or translation remain virtually linear up to bead rotations of 15 degrees, above which geometrical nonlinearities become significant. This appreciable linear range stands in contrast to the intrinsically nonlinear force-displacement relationship that is observed when cells are indented during atomic force microscopy. Finally, these computations support the idea that adhesive forces are sufficient to keep the bead firmly attached to the cell surface throughout the range of working torques.

Cell Adhesion↗

Development of hydroxyapatite bone scaffold for controlled drug release via poly(epsilon-caprolactone) and hydroxyapatite hybrid coatings.

A scaffold-coating design, the hydroxyapatite (HA) porous bone scaffold coated with poly(epsilon-)caprolactone (PCL) and HA powder hybrids, was developed for use as tissue-regeneration and controlled-release system. An antibiotic drug, tetracycline hydrochloride (TCH), was encapsulated within the hybrid coating layer through a dip-coating and solvent-casting method. Coating cycle and drug loading amount differed to control the level of drug-release rate. The HA scaffold framework, obtained by a polymeric foam reticulate method, exhibited a highly porous structure, with porosity and pore size of approximately 87% and 180 microm, respectively. The hybrid layer, consisting of PCL sheet and HA fine powders, was uniformly coated on the scaffold surface. The coating layer exhibited only PCL and HA phases and structures, revealing no chemical interaction among the coating components, as observed by X-ray diffraction (XRD) and Fourier-transform infrared (FTIR) analyses. The coated-HA scaffolds showed an effective stress distribution behavior in response to an applied load, as confirmed by the compressive stress-strain curve. The mechanical properties of the coated scaffolds were improved highly with coatings; the compressive strength and elastic modulus of the cyclic coated scaffolds were approximately 3-4 times, and the energy absorption were approximately 8 times, higher than those without coating. These improvements were attributed mainly to the shielding of framework flaws by a flexible coating layer and partially to the thicker stems (porosity reduction). The dissolution of the coated scaffolds in a phosphate-buffered saline (PBS) solution increased with incubation time. The drug was released sharply within the initial several hours ( approximately 2 h), but the rate decreased further, showing a sustained release. The release amount was well controlled via coating-cycle and initial drug loading amount, suggesting the effectiveness of the coating-scaffold design as a drug-delivery system.

Bone and Bones↗

Heterogeneity of the mechanical properties of demineralized bone.

Knowledge of the mechanical properties of the collagenous component of bone is required for composite modeling of bone tissue and for understanding the age- and disease-related reductions in the ductility and strength of bone. The overall goal of this study was to investigate the heterogeneity of the mechanical properties of demineralized bone which remains unexplained and may be due to differences in the collagen structure or organization or in experimental protocols. Uniaxial tension tests were conducted to measure the elastic and failure properties of demineralized human femoral (n = 10) and tibial (n = 13) and bovine humeral (n = 8) and tibial (n = 8) cortical bone. Elastic modulus differed between groups (p = 0.02), varying from 275 +/- 94 MPa (mean +/- SD) to 450 + 50 MPa. Similarly, ultimate stress varied across groups from 15 + 4.2 to 26 + 4.7 MPa (p = 0.03). No significant differences in strain-to-failure were observed between any groups in this study (pooled mean of 8.4 +/- 1.6%; p = 0.42). However, Bowman et al. (1996) reported an average ultimate strain of 12.3 +/- 0.5% for demineralized bovine humeral bone, nearly 40% higher than our value. Taken together, it follows that all the monotonic mechanical properties of demineralized bone can display substantial heterogeneity. Future studies directed at explaining such differences may therefore provide insight into aging and disease of bone tissue.

Aged↗

Viscoelasticity of anionic polymers and their mucociliary transport on the frog palate.

The influence of formulation variables on the rheology of polyanionic formulations and the relationships between viscoelastic properties and mucociliary transport rate were investigated. Polymeric samples were oscillated from 0.001 to 5 Hz using either a "cone and plate" or a "coaxial cylinder" measuring system. The mucociliary transport rates of polymeric samples were determined and compared movement of charcoal powder on the frog palate. For the linear polymeric solutions, sodium carboxymethylcellulose and sodium alginate, the elastic modulus (G') increased with increasing amplitudes during frequency scan. However, the G' or viscous modulus (G'') of partially cross-linked polyacrylic acid (cPAA) samples did not change significantly under oscillation. Both G' and G'' of cPAA samples were significantly influenced by the amount of salt present in the formulation. The rheology of 2% (w/w) cPAA in 90:10 (w/w) propylene glycol:alcohol changed from a viscous fluid to a coarse suspension after neutralization. The pH increased gradually when the nonaqueous formulation reacted with water and the maximum dynamic moduli were obtained after incorporating 20% (w/w) water in the formulation. A negative correlation was found between the G' of linear polyanionic samples and the relative transport rate. However, the lowest mucociliary transport rate was observed when the loss tangent (G''/G') was around 0.4-0.5.

Acrylic Resins↗

Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components.

This paper presents an analytical model of the cobalt-based alloy-ultra-high molecular weight polyethylene (UHMWPE) wear coupling. Based on a previous model in which the cup wear volume over a gait cycle (WG) was calculated under the simplifying assumption of an ideal rigid coupling, the current version proposes a more realistic wear simulation. All three components of the hip loading force were considered for the contact pressure calculation and all three components of the hip motion were taken into account for the sliding distance calculation. The contact pressure distribution was calculated on the basis of the Hertzian theory for the elastic contact of two bodies with non-conforming geometrical shapes. The wear factor was taken from hip simulator wear tests. The calculated WG is 67 x 10(-6) mm3 for a standard reference patient. The parametric model simulations show that WG increases linearly with the patient weight, femoral head diameter and surface roughness. It increases non-linearly to a maximum and decreases to an asymptotic value with increasing cup/head clearance and with cup isotropic elastic modulus. The cup orientation in the pelvis affects only slightly the total amount of WG whereas it is the dominant factor affecting the shape of the wear distribution. The iso-wear maps show paracentral patterns at low cup inclination angles and marginal patterns at higher inclination angles. The maximum wear depth is supero-posterior when the cup is in neutral alignment and supero-anterior at increasing anteversion angles. Complex patterns with a combination of paracentral and marginal wear were obtained at specific clearance values and cup orientations. The results of the simulations are discussed in relation to the wear distribution measured on the articular surface of 12 UHMWPE components retrieved from failed hip joint prostheses, after a period of in situ functioning.

Biomechanical Phenomena↗

A novel approach to observing articular cartilage deformation in vitro via magnetic resonance imaging.

The design of a pressure cell that compresses a cartilage specimen in one dimension within an imaging magnet is presented. One-dimensional projection images in a direction perpendicular to the articular surface of the cartilage specimen were used to generate a uniaxial confined deformation creep curve for normal and trypsin-degraded cartilage specimens during a continuous 0.690 MPa (100 psi) pressure application. The resulting curves are shown to fit a two time constant viscoelastic model well and also indicate that the elastic modulus of cartilage decreases and the deformation rate increases upon trypsin proteolysis. Furthermore, cartilage permeability is shown as a function of cartilage strain for both the normal and trypsin-degraded case. Several two-dimensional slice-selective images were collected both before and after 80 minutes of continuous compression. These images were used to evaluate the relative changes in the spin-lattice, T1, and spin-spin, T2, relaxation time constant maps for both normal and degraded cartilage specimens in response to compression. The results of this study demonstrate the utility of a novel, non-magnetic, cartilage compression device and also support the validity of a simple two-component rheological model of articular cartilage.

Animals↗

Development of a beta-type Ti-12Mo-5Ta alloy for biomedical applications: cytocompatibility and metallurgical aspects.

Ti-based biocompatible alloys are especially used for replacing failed hard tissue. Some of the most actively investigated materials for medical implants are the beta-Ti alloys, as they have a low elastic modulus (to inhibit bone resorption). They are alloyed with elements such as Nb, Ta, Zr, Mo, and Fe. We have prepared a new beta-Ti alloy that combines Ti with the non-toxic elements Ta and Mo using a vacuum arc-melting furnace and then annealed at 950 degrees C for one hour. The alloy was finally quenched in water at room temperature. The Ti-12Mo-5Ta alloy was characterised by X-ray diffraction, optical microscopy, SEM and EDS and found to have a body-centred-cubic structure (beta-type). It had a lower Young's modulus (about 74 GPa) than the classical alpha/beta Ti-6Al-4V alloy (120 GPa), while its Vickers hardness remained very high (about 303 HV). This makes it a good compromise for a use as a bone substitute. The cytocompatibility of samples of Ti-12Mo-5Ta and Ti-6Al-4V titanium alloys with various surface roughnesses was assessed in vitro using organotypic cultures of bone tissue and quantitative analyses of cell migration, proliferation and adhesion. Mechanically polished surfaces were prepared to produce unorientated residual polished grooves and cells grew to a particularly high density on the smoother Ti-12Mo-5Ta surface tested.

Animals↗

Bending and buckling of carbon nanotubes under large strain.

The curling of a graphitic sheet to form carbon nanotubes produces a class of materials that seem to have extraordinary electrical and mechanical properties. In particular, the high elastic modulus of the graphite sheets means that the nanotubes might be stiffer and stronger than any other known material, with beneficial consequences for their application in composite bulk materials and as individual elements of nanometre-scale devices and sensors. The mechanical properties are predicted to be sensitive to details of their structure and to the presence of defects, which means that measurements on individual nanotubes are essential to establish these properties. Here we show that multiwalled carbon nanotubes can be bent repeatedly through large angles using the tip of an atomic force microscope, without undergoing catastrophic failure. We observe a range of responses to this high-strain deformation, which together suggest that nanotubes are remarkably flexible and resilient.

Carbon↗

Erythrocyte deformability has no influence on the rate of erythrophagocytosis in vitro by autologous human monocytes/macrophages.

Erythrocytes with decreased deformability are known to be rapidly removed from the circulation by splenic macrophages. The exact mechanism is, however, not well understood. We have analysed the phagocytosis of less-deformable erythrocytes by macrophages in vitro. Human monocytes/macrophages were isolated from peripheral blood and cultured for a total time of 6 h at 37 degrees C with 5% CO2. Autologous erythrocytes of the rhesus positive donor were rigidified by heat treatment (47 degrees C for 1 h). The change in erythrocyte deformability was assessed with a filter aspiration technique; the membrane elastic modulus was found to be increased about 2.5-fold. For controls, untreated erythrocytes and erythrocytes incubated with anti-RhD-antibodies were prepared. The rate of phagocytosis during 2 h at 37 degrees C and 5% CO2 was 0.74 +/- 0.59 (erythrocytes per monocyte/macrophage) for controls, 3.58 +/- 2.72 for anti-RhD-loaded erythrocytes and 0.82 +/- 0.74 for heat-treated erythrocytes, respectively. We conclude that decreased erythrocytes deformability does not cause an increased rate of phagocytosis by monocytes/macrophages compared to normally deformable erythrocytes in our in vitro model. This suggests that the preferential removal of rigid cells in vivo is probably not a specific process, but is due to the increased splenic transit time of rigid erythrocytes and hence longer interaction time between erythrocytes and phagocytes.

Cells, Cultured↗

Mechanical properties of normal and mdx mouse sarcolemma: bearing on function of dystrophin.

The tensile strength of the muscle fibre surface membrane was estimated (1) from the suction required to burst membrane patches and (2) by aspiration of sarcolemmal vesicles into micropipettes of uniform bore. Each method gave an average value close to 60 microN cm-1 for the maximum tension sustainable by normal mouse sarcolemma and only slightly lower values for sarcolemma from mdx mice which lack dystrophin. The elastic modulus of area expansion, as measurable by pipette aspiration of sarcolemmal vesicles, was found to have an average value of 3160 microN cm-1 for normal and 2770 microN cm-1 for mdx mouse sarcolemma. The tensile strength of the sarcolemma is much too small for any differences in it to be the basis for the different osmotic behaviour of normal and mdx muscle fibres reported recently (Menke & Jockusch, 1991). By analogy with the better understood origin of the osmotic fragility of different types of red blood cells, the higher osmotic fragility of mdx muscle fibres is suggested to be of morphological origin. We postulate that dystrophin functions as an element of the submembrane cytoskeleton so as to maintain the normal folding which safeguards the sarcolemma against mechanical damage.

Animals↗

Human enamel erosion in constant composition citric acid solutions as a function of degree of saturation with respect to hydroxyapatite.

The objective of this study was to investigate human enamel erosion under constant composition conditions, as a function of solution degree of saturation (DS) with respect to hydroxyapatite. The experimental conditions were relevant to the initial stages of enamel erosion by soft drinks. Nanoindentation was used to compare enamel surface softening caused by a control mineral water and two citric acid solutions with DS = 0.000 and DS = 0.032, both having pH 3.30. Enamel hardness and reduced elastic modulus were measured after 0, 30, 60, 120, 300 and 600 s exposure. A statistically significant change in enamel hardness was detected after 30 s exposure to both citric acid solutions, indicating that nanoindentation is extremely sensitive to the initial stages of erosion. There was a statistically significant difference between the mechanical properties of enamel exposed to the two citric acid solutions after 30, 60 and 120 s. At these times, the solution with DS = 0.000 caused twice as much enamel softening as that with DS = 0.032. This demonstrates that it may be possible to design a soft drink with a low erosive potential and a good taste by a small change in DS, at a typical drink pH.

Beverages↗

Effects of orally administered drugs on dynamic viscoelasticity of human nasal mucus.

The effects of orally administered drugs on rheologic properties of nasal mucus were investigated in adult chronic sinusitis patients. The elastic modulus G' and the dynamic viscosity eta' of nasal mucus were determined by an oscillating sphere magnetic rheometer. Both G' and eta' values of the mucus before drug administration were much higher than optimal viscoelasticity for mucociliary transport. Norfloxacin, an antibacterial agent, reduced the G' but not the eta' of nasal mucus. Serratiopeptidase, a proteolytic enzyme, reduced eta' but did not reduce G'. S-carboxymethylcysteine, a blocked thiol derivative of cysteine, did not change either G' or eta'. L-cysteine ethyl ester hydrochloride, a sulfhydryl type of agent, reduced both G' and eta'. The results indicate that some of the orally administered mucokinetic agents can improve the abnormal rheologic properties of nasal mucus in chronic sinusitis.

Administration, Oral↗

A simple model describing the elastic properties of human umbilical arterial smooth muscle.

Elastic properties of cylindrical segments of 71 normal double and 4 single human umbilical arteries were studied. This specimen is rich in vascular smooth muscle in comparison with other great arteries. Outer diameter versus intraluminal pressure characteristic curves were taken with decreasing pressures in vitro in different contraction states. Tangential force and circumferential incremental elastic modulus were computed. A sum of 222 curves was analysed. The investigations showed that if we take tangential force and outer radius values measured at the same pressure levels but in different contraction states, then a similar proportional change in tangential force will induce a similar proportional passive change in the outer radius, to some extent independently of the degree of active tangential shortening of the segment. For example to induce a 10% passive decrease of the outer radius from values measured at 100 mm Hg intraluminal pressure, tangential force had to be decreased by 76.7 +/- 9.9% in single relaxed arteries, and by 79.6 +/- 0.8% in normal double relaxed segments. These values corresponded to intraluminal pressure levels of 26.4 +/- 4.9 mm Hg and 23.1 +/- 0.9 mm Hg, respectively. In 30% active spontaneous shortening to reach the same 10% passive decrease in outer radius from the value measured at 100 mm Hg, tangential force had to be decreased by 75.2 +/- 1.9% which corresponded to 29.6 +/- 20 mm Hg. The same values in 5-HT induced contraction, 30% active shortening were 76.7 +/- 2.0% and 28.4 +/- 2.6 mm Hg, respectively. In addition to the similarity of relative changes in tangential force, the pressure levels were to some extent also similar. These data suggest that elastic elements in the human umbilical arterial smooth muscle may be organized in such a way as to ensure similar prestretch of similar elastic elements at similar pressures independently of the degree of active shortening of the circumference.

Algorithms↗

Static indentation of anisotropic biomaterials using axially asymmetric indenters--a computational study.

Indentation has historically been used by biomechanicians to extract the small strain elastic or viscoelastic properties of biological tissues. Because of the axisymmetry of indenters used in these studies however, analysis of the results requires the assumption of material isotropy and often yields an "effective" elastic modulus. Since most biological tissues such as bone and myocardium are known to be anisotropic, the use of conventional indentation techniques for estimating material properties is therefore limited. The feasibility of using an axially asymmetric indenter to determine material directions and in-plane material properties for anisotropic tissue is explored here using finite element analysis. The load versus displacement curves as would be measured by an indenter depend on the orientation of the indenter cross section relative to the in-plane material axes, thus suggesting a method for determining the underlying material directions. Additionally, the stiffness of the tissue response to indentation is sensitive to the values of the in-plane anisotropic material properties and prestretches, and thus test results can be used to back out relevant constitutive parameters.

Anisotropy↗

Application of a glass fiber-reinforced composite material to clasps--the effects of immersion and repeated loading.

The aim of this study was to investigate the effects of water immersion and repeated loading on the mechanical properties of a glass fiber-reinforced composite (FRC) material. Measurements for three-point flexural tests were made at three different temperatures and cross-head speeds, while measurements for fatigue tests were made under three different loads in air or water at 37 degrees C after each cycle. The flexural strength and elastic modulus of the immersed specimens were significantly lower than those of the dry specimens at the same cross-head speed and temperature. On the whole, the values were inferior to those of metal. The deflection increased significantly as the load increased, but there were no significant differences between the values of dry and immersed specimens. With increasing load and number of cycles, the permanent deformation of both specimens increased significantly. The permanent deformation was similar to that of Co-Cr alloy. Based on the results of this study, it is recommended that more effort be devoted to exploring and devising shapes that would render FRC clasp arms with mechanical and physical properties that differ favorably from those of metal.

Analysis of Variance↗

Hydroxyapatite and gelatin composite foams processed via novel freeze-drying and crosslinking for use as temporary hard tissue scaffolds.

Hydroxyapatite (HA) and gelatin composites were fabricated in a foam type via a novel freeze-drying and crosslinking technique. The morphological and mechanical properties of and in vitro cellular responses to the foams were investigated. The HA powder was added at up to 30 wt % into the gelatin solution, and the mixtures were freeze-dried and further crosslinked. The pure gelatin foam had a well-developed pore configuration with porosity and pore size of approximately 90% and 400-500 microm, respectively. With HA addition, the porosity decreased and pore shape became more irregular. The HA particulates, in sizes of about 2-5 microm, were distributed within the gelatin network homogeneously and made the framework surface rougher. All the foams had high water absorption capacities, showing typical hydrogel characteristics, even though the HA addition decreased the degree of water absorption. The HA addition made the foam much stronger and stiffer (i.e., with increasing HA amount the foams sustained higher compressive stress and had higher elastic modulus in both dry and wet states). The osteoblast-like human osteosarcoma cells spread and grew actively on all the foams. The cell proliferation rate, quantified indirectly on the cells cultured on Ti discs coated with gelatin and gelatin-HA composites using MTT assay, exhibited an up-regulation with gelatin coating compared with bare Ti substrate, but a slight decrease on the composite coatings. However, the alkaline phosphatase activities expressed by the cells cultured on composites foams as well as their coatings on Ti discs were significantly enhanced compared with those on pure gelatin foam and coating. These findings suggest that the gelatin-HA composite foams have great potential for use as hard tissue regeneration scaffolds.

Animals↗

Mechanical characterization of an unusual elastic biomaterial from the egg capsules of marine snails (Busycon spp.).

Egg capsule material serves as a putative protection mechanism for developing snail embryos facing the perils of the marine environment. We conducted the first quantitative study of this acellular structural protein with the goals of characterizing its chemical and mechanical properties and the relationship of these properties to its biological protective function. We have found that this protein polymer exhibits long-range elasticity with an interesting recoverable yield evidenced by an order of magnitude decrease in elastic modulus (apparent failure) that begins at 3%-5% strain. This material differs significantly from other common structural proteins such as collagen and elastin in mechanical response to strain. Qualitative similarities in stress/strain behavior to keratin, another common structural protein, are more than coincidental when composition and detailed mechanical quantification are considered. This suggests the possibility of alpha-helical structure and matrix organization that might be similar in these two proteins. Indeed, the egg capsule protein may be closely related to vertebrate keratins such as intermediate filaments. We conclude that while this material's bimodal tensile properties may serve as useful protection against the impact loading egg capsules encounter in the intertidal zone, the full biological importance of these capsules is not known.

Amino Acids↗

Mechanical properties of an experimental soft lining material based on urethane oligomer.

The purpose of this study was to investigate the apparent viscosities and mechanical properties of two experimental light-curing soft lining materials (SLM-1 and SLM-2) based on soft-type urethane oligomers, as well as the shear bond strength and dye penetration between the denture base resin and the polymerized SLMs after storage in water. The apparent viscosities of SLM-1 and SLM-2 were 144.0-146.9 and 1.9 Pa x s respectively. After storage in water for two prescribed periods (one day and three months), the mechanical properties of the SLMs on the overall were 10.6-20.6 MPa for elastic modulus, 69.3-72.1 for hardness, and 3.8-4.0 MPa for adhesive strength. Tensile strength was observed to decrease after three months' storage in water, when compared to that after one-day storage (p < 0.01). Water sorption rates also differed significantly (p < 0.05)--namely 3.0 and 2.8 mg/cm2 for SLM-1 after one day and three months respectively, and 2.0 and 2.2 mg/cm2 for SLM-2. As for dye penetration, no infiltration was observed at the denture base resin-SLM interface after three months' storage. Based on the results of this study, it seemed like the SLMs possess many suitable properties for use with a new technique that we recently developed for preparing denture base resin and soft lining material.

Acrylic Resins↗