PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Isometric”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92Linked to original sources

Relevance of the EMG/grip relationship in isometric anisotonic conditions.

The aim of the present study was to develop a relationship to evaluate grip force using the electromyogram (EMG) in isometric anisotonic conditions. The EMGs of the flexor digitorum superficialis (FDS) and the extensor digitorum (ED) were recorded in 3 flexion-extension positions of the wrist (30 degrees flexion, 30 degrees extension, and 60 degrees extension) associated with 3 positions of the forearm (70 degrees pronation, prono-supination, and 70 degrees supination). For each position, the participants had to follow linear ramp targets (2 rates of increase and decrease) displayed on an oscilloscope. The results show the best fit is a quadratic type force-EMG relationship. Some aspects such as the rate of force variation and the forearm and wrist positions are then discussed along with the limitations of the relationship.

Cumulative Trauma Disorders↗

Isometric pull-push strengths in workspace: 1. Strength profiles.

The isometric pull and push strength profiles of males and females were determined in seated and standing positions in the workspace. The strongest pull strength location was at extreme reach vertically above the shoulder for both males and females. The greatest pull strength of 400 Newtons (N) for males was recorded in the seated and standing positions. Females' pull strengths in the seated and standing positions were 222 and 244 N, respectively. The strongest push strength was always at the maximum reach at the overhead location. Males' maximum push strength was 227 N in the seated position and 251 N in the standing position. Females' maximum push strength was 96 N in the seated position and 140 N in the standing position. On the average the strength in the standing position was 79% of the seated position. The push strength was 71% of the pull strength and females were 56% as strong as males.

Adult↗

Isometric pull-push strengths in workspace: 2. Analysis of spatial factors.

The effect of reach levels, horizontal angles and vertical angles on isometric pull and push strengths of males and females in standing and seated positions was determined. The effect of reach levels on strength varied as a consequence of force direction, working position and gender. Reach level has a significant effect on women's pull strength in the seated position and on push strength in the standing position. The strength value was significantly greater in the extreme reach than in maximum or normal reach. Vertical angle phi had a significant effect on strength consistently in all cases. Strength values increased significantly with the increase of phi angles from 0 degrees to 45 degrees to 90 degrees. The horizontal angle theta had a significant influence only on the pull strength of standing and seated men and standing women (not seated woman). The maximum strength was significantly greater at theta = 90 degrees.

Adult↗

Maximum voluntary isometric contraction: investigation of reliability and learning effect.

Maximum Voluntary Isometric Contraction (MVIC) is a standardised, objective and sensitive tool for the measurement of muscle strength. The purpose of this study was to investigate different aspects of reliability of MVIC and to determine if a learning effect existed in a relatively new user of the system. Two clinical investigators participated in the study. The inter- and intra-rater reliability of MVIC of 11 muscle groups was tested on healthy subjects (n=35). Intra-class correlation co-efficients (ICCs) were calculated and the statistical methods described by Bland and Altman were applied to the data. ICCs were higher for the more experienced investigator and a learning effect was demonstrated in a relatively new user of the system. Inter-rater reliability was acceptable but lower than intra-rater reliability. Upper limb tests generally yielded higher ICCs and lower ranges of error. The ICC was similar regardless of whether the maximum or average of the two values was taken in a single session. Utilising the statistical methods proposed by Bland and Altman allows estimation of the magnitude of error of MVIC and gives additional information to the ICC. These methods may be useful in the training of investigators and in clinical interpretation of MVIC values.

Adaptation, Physiological↗

Myosin heavy chain isoform expression: influence on isoinertial and isometric performance.

Thirty-six healthy men with varying degrees of physical training background performed maximal-effort isometric and isoinertial knee extensor actions, with relative loads equal to 40% and 70% of one-repetition maximum. Force, velocity, and power were derived from force and linear position transducers at 500 Hz. Biopsies were taken from the vastus lateralis and analyzed by SDS-PAGE for relative myosin heavy chain (MHC) content. Relative MHC IIx content was included in a regression model, and explained variance noted. Relative MHC I content was subsequently added to the regression model to determine what, if any, additional variance was explained beyond that of MHC IIx. Results indicated that no relationship (r = 0.0 to 0.1) exists between the relative expression of MHC isoforms from the vastus lateralis and isometric/isoinertial performance in a population with diverse training backgrounds. Lack of nervous system adaptations in the untrained subjects in the study possibly attenuates the significant relationship between MHC and in-vivo muscle performance previously established in trained populations.

Adult↗

Evaluation of grip strength with a sustained maximal isometric contraction for 6 and 10 seconds.

The grip strength in which subjects sustained a maximal isometric contraction for 6 seconds (the 6-second test) was compared with that for 10 seconds (the 10-second test) to clarify a reliable sustained grip strength test procedure. Fifty healthy students (22+/-4 years, 25 men and 25 women) participated in this study. Strength was measured continuously by the Dexter (Cedaron Medical Inc.). The maximal grip strength, the peak time, and the momentary strength every second during a trial were evaluated. For both tests, the reliable maximal strength and a typical strength-time curve consisting of an early peak time and a decrease in the strength after the peak gradually over time were obtained. In the 6-second test, the momentary strength after 5 seconds that was 82+/-10 approximately 87+/-7% of the peak strength showed good reliability. This variable may be effective in assessing the ability to sustain maximal grip strength.

Adolescent↗

Electrical impedance of muscle during isometric contraction.

Non-invasive measurements of the 50 kHz impedance of the anterior forearm show that the resistance and reactance increase under voluntary isometric contraction of the finger flexor muscles. The relationship between impedance and force is nonlinear, dependent on the type of test, the history of prior exercise, and the health status of the subject. Nevertheless, useful dynamic response parameters betaR = deltaR/R0deltaF and betax = deltaX/X0deltaF can be defined, typically a few hundredths of a per cent per newton. Evidence is presented for the view that these effects reflect dominantly physiological as opposed to morphological changes in the muscle. In particular, (a) the impedance changes many milliseconds before the force is generated, (b) betaR and betaX change substantially during a series of repetitions of the same exercise, and (c) the impedance does not return to its original value following relaxation of the muscle. Supporting data are presented for six healthy men and women, with ages ranging from 19 to 70 years. A preliminary study of patients with various neuromuscular diseases was also performed, amongst whom marked quantitative and qualitative contrasts with the healthy group were found. Further research aimed at assessing the clinical potential of such measurements is discussed, as are studies to elucidate the underlying mechanisms for the impedance changes. We propose the name 'dynamic electrical impedance myography' for this new technique.

Aged↗

Short-term synchrony of motor unit discharge during weak isometric contraction in Parkinson's disease.

Short-term synchrony between the discharges of motor units has been assessed in Parkinson's disease (PD) and normal man. The discharges of single motor units were recorded in the extensor digitorum communis (EDC) muscle of the forearm or the tibialis anterior (TA) muscle of the leg during weak, voluntary isometric contraction. Short-term synchrony was defined as a narrow peak (total width less than 25 ms) in cross-correlograms constructed from the discharges of pairs of motor units. There was no difference in the incidence of short-term synchrony between PD and normal age-matched subjects for either the EDC or TA muscle. On average, 60% of pairs of motor units exhibited synchrony, but this varied between 0% and 100% for both groups. The amount of short-term synchrony was assessed as the probability (above chance) of discharge of one motor unit with respect to the other. In TA, but not EDC, this index was greater for PD than for normal subjects. The high indices of synchrony in TA in PD were not related to lower discharge rates of motor units. Parkinson's disease subjects, but not normal subjects, also showed broad correlations that were invariably associated with periodic discharges in the range 4-6 Hz. In some instances, a peak of short-term synchrony was observed superimposed on the broad correlation. The periodic correlograms were often associated with overt tremor which accompanied the contraction. Motor units occasionally discharged paired impulses (doublet discharges) with short interspike intervals of 5-15 ms (normal and PD) or, as a more persistent feature in PD, longer interspike doublets (20-60 ms) associated with periodic synchrony (4-6 Hz). The abnormal discharge characteristics of motor units are discussed in relation to the bulbospinal control of presynaptic drive to motor neurons in PD.

Adult↗

Plasma norepinephrine responses to posture and isometric exercise increase with age in the absence of obesity.

This study examines the effects of age on plasma norepinephrine (NE) responses to upright posture and isometric handgrip exercise in nonobese men. Increasing age was associated with increased basal levels of plasma NE as well as increased NE responses to upright posture. These results suggest that aging affects sympathetic system activity by mechanisms largely independent of the increasing adiposity generally associated with aging.

Adult↗

Reliability of isometric hip abductor torques during examiner- and belt-resisted tests.

The purposes of this study were to determine the test-retest reliability of isometric hip abductor torques in elderly females, to compare two assessment protocols, and to compare the performances of elderly and young females. Twenty elderly and 20 young women were tested on two occasions. During the examiner-resisted test the examiner provided the resistance, and during the belt-resisted test the subject's contralateral leg provided the resistance while the examiner positioned the dynamometer. A four-way ANOVA indicated no occasion effects (p greater than .05). Within each group, similar torques were produced by both legs (p greater than .05). Test-retest intraclass reliability coefficients were good-to-high, ranging from 0.84 to 0.98 for the eight combinations of group-method-leg. The elderly females produced 61% of the torques produced by young females (p less than .01), and the examiner-resisted method produced 65% of the torques produced using the belt-resisted method (p less than .01). The belt-resisted method required less physical effort on the part of the tester, provided greater stabilization of the pelvis, and was preferred by 95% of the subjects.

Adult↗

Isometric contractile properties of single myofibrils of rabbit skeletal muscle.

The isometric contractile properties of single myofibrils of rabbit skeletal muscle were studied at various sarcomere lengths. Single myofibrils were suspended between the tips of one rigid and one flexible glass microneedle, and their force production was determined by detecting the bending of the flexible microneedle photo-electronically. The active force vs. sarcomere length relation had an ascending limb (0.7-2.25 micron), a plateau (2.25-2.5 micron), and a descending limb (2.5-3.8 micron), which was similar to that of frog skeletal muscle. The passive force became increasingly apparent beyond a sarcomere length of 2.4 micron. These results can reasonably be explained based on the sliding filament mechanism by assuming the sarcomere geometry of rabbit muscle. The plateau, with a produced force of about 256 kN/m2, and the linear decline of force in the descending limb of the single myofibrils were essentially the same as those for frog muscle fibers. However, the slope of the force decline in the ascending limb was far steeper than that for frog muscle. This suggests that internal elements of sarcomeres are different between rabbit and frog muscles.

Animals↗

Effects of the asymmetric tonic neck reflex and high-frequency muscle vibration on isometric wrist extension strength in normal adults.

The effects of the asymmetric tonic neck reflex and high-frequency muscle vibration on isometric wrist extension strength were studied in 150 normal, right-handed adults between the ages of 18 and 40. Subjects were randomly assigned to one of five groups. From data collected from two control groups, we determined any confounding effects of fatigue, experimental learning, or weight of the vibrator in contact with the skin surface overlying the wrist extensor muscle bellies. From measurements taken from three experimental groups, we determined the individual and combined effects of the asymmetric tonic neck reflex and vibration. The reflex was elicited with active head rotation. Strength significantly increased with active head rotation toward the extending wrist; active head rotation away from the wrist significantly decreased strength. Vibration of the extensor surface of the forearm with the head in neutral significantly increased strength. The combination of active head rotation toward the extending wrist and vibration of the extensor surface resulted in a greater increase in strength than did either technique individually.

Adolescent↗

Decreased isometric knee flexion torque with hip extension in hemiparetic patients.

I measured the 90-degree isometric knee flexion torque of 12 hemiparetic patients while they performed unilateral knee flexion in sitting and supine positions. The measurements were taken to clarify why hemiparetic patients have difficulty flexing their involved knees when their involved hip is extended. The patients generated more torque in the sitting position than in the supine position and more torque on their nonparetic side than on their paretic side. The ratio of supine-to-sitting knee flexion torque did not differ significantly between sides. This finding suggests that hemiparetic patients do not have relatively greater difficulty generating knee flexion torque on their involved side with the hip extended than with the hip flexed. Recommendations for assessment and treatment are made with this finding in mind.

Adult↗

Effect of electrical stimulation current frequencies on isometric knee extension torque.

The purpose of this study was to compare the isometric knee extension torques of male and female subjects during maximal voluntary contractions (MVCs), electrical stimulation only, and electrical stimulation superimposed onto MVCs at electrical stimulation current frequencies of 20, 50, and 100 Hz. An asymmetrical, bidirectional, nonionizing waveform of 1-msec pulse duration was delivered through the femoral nerve and the superficial quadriceps femoris muscles at maximally tolerated intensity for each subject. The male subjects (n = 20) demonstrated significantly greater absolute torques under all contraction conditions than did the female subjects (n = 20) (p less than .01); when the torques were expressed as a percentage of each subject's MVC torque, however, no significant differences were observed between the sexes. Overall, the superimposed contractions at 50 and 100 Hz and the MVCs had similar torque values, all being significantly greater than the torque values produced by electrical stimulation only at frequencies of 20, 50, and 100 Hz and by the superimposed contractions at 20 Hz. Superimposing electrical stimulation onto MVCs did not result in greater torques than those produced by the MVCs alone. The three most effective contraction conditions, in terms of subject comfort (minimal discomfort) and increased torque, were the superimposed contractions at 50 and 100 Hz and MVCs alone, all of which involved a voluntary component.

Adolescent↗

Effect of inherent muscle length on isometric plantar flexion torque in healthy women.

This study investigated the relationship between inherent muscle length and torque production in 59 healthy women. We recorded nondominant ankle range-of-motion values for each subject. These values were partitioned into quartiles for two knee positions. Women with "loose" plantar flexor muscles comprised the first quartile, and those with "tight" plantar flexor muscles the fourth quartile. Tight- and loose-muscle groups were established for the 0-degree (fully extended) and 90-degree (flexed) knee test positions for data analysis. Torque measurements were obtained using an isokinetic testing apparatus. We asked each subject to perform a maximal isometric (static) plantar flexion contraction at each of three ankle positions: 7 degrees of dorsiflexion (angle A), 0 degrees or neutral (angle B), and 30 degrees of plantar flexion (angle C). Data analysis was performed using an analysis of variance for repeated measures. Results indicated that torque produced by the tight-muscle groups was significantly greater than the torque produced by the loose-muscle groups at both knee positions (p less than .05). Additionally, the ankle ROM data obtained suggest normative data different from those currently prevalent in the literature. Findings of this study may prove valuable in the rehabilitation of ankle injuries and could be beneficial especially to physical therapists in understanding more about normal ankle function.

Adolescent↗

Comparison of maximal isometric hip abductor muscle torques between hip sides.

A posturally induced "stretch weakness" of the right hip abductor muscles has been reported in many healthy right-handed persons in the literature. The purpose of this study was to test for differences in the maximal isometric hip abduction torque produced between hip sides across multiple hip abduction angles. The torques were measured on 40 healthy right-handed individuals using a specialized torque-testing table at hip abduction angles of -10, 0, 10, 20, 30, and 40 degrees. Statistical analysis of the results did not demonstrate a specific "weakness" of the right hip abductor muscles at the hip angle used to clinically test them. The results, however, did demonstrate statistically significant differences in the torque-hip angle slopes across hip sides. We hypothesized that these slope differences may result from muscle adaptation to lengths imposed by standing posture. We discuss how manual muscle testing procedures may bias the likelihood of encountering stretch weakness in muscles that are habitually maintained at near-maximal elongation.

Adult↗

The application of generalizability theory to reliability assessment: an illustration using isometric force measurements.

BACKGROUND AND PURPOSE: The objective of this study was to examine the potential use of the generalizability theory for assessing reliability of muscle force measurements in clinical applications. Reliability is expressed in terms of standard error of measurement (SEM) and the indexes derived from the SEM. Using generalizability theory, potential sources of measurement error can be recognized and estimated. SUBJECTS: Ten healthy women, aged 23 to 47 years (means = 29.5, SD = 7.1), participated in the study. METHODS: The method is illustrated by presenting a pilot study. Repeated measurements of maximal isometric knee extension force were carried out by two therapists. The time interval between measurement occasions was 1 week. A functional prototype of a hand-held dynamometer was used, and measurements were carried out according to standardized test protocols. RESULTS: Relatively important sources of measurement error were associated with interaction effects between subject and therapist as well as with interactions including the factor occasion. The SEM of the net knee moment was estimated for various hypothetical applications of the dynamometer. CONCLUSION AND DISCUSSION: It is concluded that the SEM, the corresponding confidence interval, and the smallest detectable difference are practical measures for expressing reliability of measurements on an individual. Generalizability theory is a powerful tool for estimating the magnitude of multiple sources of measurement error and for assessing the reliability of measurements tailored to specific clinical applications.

Adult↗

The effect of near-maximal isometric stress on the presence and amplitude of fourth heart sounds.

Near-maximal isometric exercise (IHG) was employed to provoke new, or alter pre-existing fourth heart sounds (S4s) in ambulatory middle-aged normal subjects (N), hypertensive patients (HHD), and patients with coronary disease (CAD). S4 amplitudes and systolic time intervals (STIs) were measured blindly. No subjects without a resting S4 developed a new S4 during IHG. Increases and decreases of pre-existing S4 provoked by IHG were not statistically different among all groups. Among subjects matched for presence of S4, STIs during IHG showed significant shortening of the ejection time index and prolongation of Q-Im in the HHD group only. When the subjects who increased a resting S4 during IHG were compared with the subjects who decreased their resting S4 during IHG there were no significant differences in the responses of STIs. Thus, in these ambulatory, hypertensive patients, coronary patients, and normal subjects, near-maximal IHG did not induce new S4s and had variable effects on pre-existing S4s. Neither type of S4-response could be associated with corresponding changes in systolic time intervals.

Aged↗