PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

Feasibility and psychometrics of an ambulatory hot flash monitoring device.

OBJECTIVE: To assess the feasibility and psychometric properties of a lightweight, automated, ambulatory sternal skin conductance monitor to measure frequency of hot flashes (HFs) among breast cancer survivors (BCSs). DESIGN: A total of 19 postmenopausal BCSs and 5 premenopausal healthy comparison women participated by wearing the monitor for 24 h during their normal daily activities, including sleep. HFs were assessed using subjective (diaries, event markers) and objective (skin conductance) methods. RESULTS: Problems with subjective reporting of HFs were reported by 35% of BCSs. Technological problems and discomfort related to wearing the monitor were minimal. A total of 243 HFs were recorded using the skin conductance monitor by 17 BCSs and 5 premenopausal women (BCS group M = 13.4; range, 1-30). Subjective reporting of HFs was associated with a 31-33% false-positive rate. Skin conductance monitoring during waking hours was associated with a 30% false-negative rate. CONCLUSIONS: The monitor is a feasible method for objectively assessing HFs in BCSs. Data support continued use of sternal skin conductance as an objective measure of HF frequency. This technology should prove useful as an objective measure of HFs in future intervention research aimed at alleviating the symptom and improving quality of life among BCSs.

Adult↗

24-hour monitoring of intraocular pressure in glaucoma management: a retrospective review.

PURPOSE: Diurnal variation in intraocular pressure (IOP) is well recognized, yet important decisions in glaucoma management are frequently made after 1 or 2 IOP measurements. Twenty-four-hour monitoring of IOP may identify IOP variation and spikes. This study determined the value of 24-hour IOP monitoring in routine clinical practice. METHODS: Data were acquired retrospectively from case notes of 29 glaucoma patients sequentially admitted for 24-hour IOP monitoring while taking their established antiglaucoma therapy. RESULTS: While there was no difference between the mean clinic (office) and mean 24-hour IOP measurements, the peak IOP during 24-hour monitoring was on average 4.9 mm Hg higher than the peak clinic IOP (P<0.0001). In 4 (13.8%) patients, the peak IOP over 24 hours was at least 12 mm Hg higher than the clinic peak. Peak IOP values occurred outside normal office hours in 51.7% of patients. Twenty-four-hour IOP monitoring resulted in a change of clinical management in 23 (79.3%) patients, including 13 (44.8%) who were offered trabeculectomy. CONCLUSION: Twenty-four-hour monitoring of IOP frequently led to a change of glaucoma management by identifying IOP fluctuations and spikes. High IOP and wide diurnal IOP variation are considered major risk factors for glaucoma progression, and standard clinic follow-up evaluations failed to identify these phenomena.

Adult↗

Limitations of current validation protocols for home blood pressure monitors for individual patients.

BACKGROUND: Automatic blood pressure monitoring conducted at home is increasingly used in the diagnosis and management of hypertension. We assessed the adequacy of existing British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) validation standards for automatic blood pressure monitoring devices. SUBJECT AND METHODS: A theoretical study and an empirical test are presented to estimate the proportion of persons for whom a blood pressure monitor validated according to existing BHS and AAMI standards would be inaccurate. RESULTS: The results suggest that a major limitation of both protocols is the lack of attention given to the number of individual patients for whom a monitor may be inaccurate. A blood pressure monitor that meets the AAMI and BHS validation criteria may report blood pressures in error by more than 5 mmHg for more than half of the people. CONCLUSIONS: A validation standard that does not take account of the person-effects on error will lead to a substantial proportion of persons using self-monitors that are systematically inaccurate for that person.

Blood Pressure Determination↗

Factors associated with probability of patient rejecting a repeat 24 h ambulatory blood pressure monitoring, despite recommendation by the physician.

OBJECTIVE: The aim of our study was to find out factors associated with patient acceptance of repeat 24 h ambulatory blood pressure monitoring (ABPM) using the Mobil-O-Graph ambulatory blood pressure monitor. METHODS: Six hundred and fifty patients had ABPM performed between July 1999 and Oct 2000. Following 24 h ABPM patients were asked to complete 13-item questionnaire. RESULTS: Ninety-five percent of the patients were willing to have 24 h ABPM repeated. There was no relation to patient's refusal to further ABPM with gender, age, height, weight, BMI, arm circumference, clinic blood pressure or 24 h ABPM profile. Patients were unlikely to have 24 h ABPM repeated if they found the monitor heavy and cumbersome (68%), if the monitor interfered with sleep (45%), or if they were so disturbed by the 24 h ABPM that they considered switching the monitor off (93%). CONCLUSIONS: Most patients were willing to have repeat ABPM using the Mobil-O-Graph and reported few problems with monitor noise, heaviness and interference with sleep. These factors however still remain significant and need more technological attention and innovation from the manufacturers.

Aged↗

Prediction of long-term facial nerve outcomes with intraoperative nerve monitoring.

OBJECTIVE: Evaluate the utility of a statistical equation using two independent intraoperative monitoring parameters in predicting long-term facial nerve function. STUDY DESIGN: Retrospective case review. SETTING: Tertiary care hospital. PATIENTS: Sixty patients undergoing resection of vestibular schwannomas with intraoperative facial nerve monitoring at a single institution. INTERVENTION: All patients underwent microsurgical resection of vestibular schwannomas with the use of intraoperative cranial nerve monitoring. MAIN OUTCOME MEASURE: Final facial nerve outcome measured using the House-Brackmann scale at least 6 months after microsurgical resection. RESULTS: Five out of 60 (8.3%) patients demonstrated significant long-term weakness (i.e., House-Brackmann grade III or worse). Intraoperative monitoring parameters (proximal stimulation threshold, proximal-to-distal response amplitude ratio) were accurate in predicting increased risk of long-term facial nerve dysfunction when used in a logistic regression model. A Student's t test confirmed the equation result was statistically significant in differentiating long-term facial nerve outcomes. CONCLUSION: Patients with immediate weakness are at higher risk of having long-term poor facial nerve function. The use of intraoperative monitoring parameters was reliable in predicting facial nerve outcomes. Patients with permanent facial nerve dysfunction often require rehabilitative procedures. The ability to predict facial nerve outcomes with intraoperative monitoring may allow early rehabilitative procedures to improve quality of life and prevent ocular complications.

Adult↗

The 2003 Carl A Moyer Award: real-time metabolic monitors, ischemia-reperfusion, titration endpoints, and ultraprecise burn resuscitation.

Real-time metabolic monitoring of varied vascular beds provides the raw data necessary to conduct ultraprecise burn shock resuscitation based on second-by-second assessment of regional tissue perfusion. It also illustrates shortcomings of current clinical practices. Arterial base deficit was continuously monitored during 11 clinical resuscitations of patients suffering burn shock using a Paratrend monitor. Separately, in a 30% TBSA rat burn model (N = 70), three Paratrend monitors simultaneously recorded arterial blood gas and tissue pCO2 of the burn wound and colonic mucosa during resuscitation at 0, 2, 4, 6, and 8 ml/kg/%TBSA. Paratrend data were analyzed in conjunction with previously reported laser Doppler images of actual burn wound capillary perfusion. With current clinical therapy, continuous monitoring of arterial base deficit revealed repetitive cycles of resolution/worsening/resolution during burn shock resuscitation. In the rat model, tissue pCO2 in both burn wounds and splanchnic circulation differed depending on the rate of fluid resuscitation (P <.01 between sham and 0 ml/kg/%TBSA and between 2 ml/kg/%TBSA and 4 ml/kg/%TBSA). Burn wound pCO2 values correlated well with laser Doppler determination of actual capillary perfusion (rho = -.48, P <.01). The following conclusions were reached: 1). Gratuitous and repetitive ischemia-reperfusion-ischemia cycles plague current clinical therapy as demonstrated by numerous "false starts" in the resolution of arterial base deficit; 2). in a rat model, real-time monitoring of burn wound and splanchnic pCO2 demonstrate a dose-response relationship with rate of fluid administration; and 3). burn wound and splanchnic pCO2 are highly correlated with direct measurement of burn wound capillary perfusion by laser Doppler imager. Either technique can serve as a resuscitation endpoint for real-time feedback-controlled ultraprecise resuscitation.

Acid-Base Equilibrium↗

Cord monitoring changes and segmental vessel ligation in the "at risk" cord during anterior spinal deformity surgery.

STUDY DESIGN: Retrospective analysis of all cases of anterior spinal deformity surgery that had intraoperative spinal cord monitoring (somatosensory-evoked potentials, SSEPs). OBJECTIVES: The prime purpose of this study was to determine the incidence of significant SSEP changes in patients undergoing anterior spinal deformity surgery. A secondary objective was to ascertain if patients with "cords at risk" were more likely to produce significant intraoperative SSEP changes and what proportion of these changes resulted in postoperative neurological deficit. SUMMARY OF BACKGROUND DATA: There is anecdotal evidence to suggest that patients with intraspinal abnormalities are at greater risk of postoperative neurological deficit after spinal deformity surgery. To date, there have been no studies detailing this risk and how it relates to the type of surgery performed. This is a question of increasing relevance with the modern trend towards more anterior scoliosis correction and instrumentation. Recent reports have suggested a low incidence of neurological complication with anterior deformity procedures. There is controversy as to whether SSEP monitoring is required for these anterior procedures and whether soft clamping of segmental vessels before their division is a necessary precaution. METHOD: This study is a chart review of all patients who had an anterior deformity operation between 1990 and 2001. Those patients who had a complete data set (preoperative magnetic resonance imaging scan, patient and procedural documentation, and adequate intraoperative SSEP traces) were included in this study. A significant SSEP change was correlated with the type of procedure performed, whether that patient had a "cord at risk" (CAR) and the degree of postoperative neurological deficit if present. RESULTS: During the study period, 871 patients underwent elective anterior spinal deformity surgery. Ninety five (11%) patients had intraspinal abnormalities on magnetic resonance imaging. From this group, 27 (3%) were termed CAR. Twenty six (3%) patients had significant change in the intraoperative SSEP monitoring. Seventeen (2% total) occurred in the CAR group and nine (1% of total) in the normal cord group. There were five patients (0.6%) with significant postoperative neurological deficits, four (0.5%) in the CAR group, and one (0.1%) in the normal cord group. These patients had also demonstrated changes in their SSEPs. The sensitivity of SSEP monitoring for the whole series was 100%, specificity 97.5%, the positive predictive value was 19% and the negative predictive value was 100%. The CAR group was significantly more likely to have significant SSEP changes during any operation and was more likely to have postoperative paresis. CONCLUSION: Patients with identified cords at risk should undergo spinal cord monitoring (SSEP) if they undergo anterior spinal deformity surgery. Soft clamping of segmental vessels is indicated with cord monitoring to prevent the risk of postoperative neurological sequelae.

Adolescent↗

Somatosensory evoked potential monitoring during anterior cervical discectomy and fusion.

STUDY DESIGN: A retrospective, multicenter clinical review was conducted. OBJECTIVE: To examine our experience using somatosensory evoked potential (SSEP) monitoring during anterior cervical discectomy and fusion (ACDF) to determine if monitoring of the spinal cord with SSEPs was helpful in identifying reversible causes of neurologic impairment while performing the procedure. SUMMARY OF BACKGROUND DATA: Recent studies have strongly supported the use of SSEP monitoring during complicated and upper-cervical spine surgery. METHODS: The complete medical records of 163 patients who underwent ACDF, and who were monitored with SSEPs during the procedure between 1995 and 2002 were retrospectively reviewed. A single observer who was uninvolved with patient care abstracted these medical records. Demographic data, length of symptoms, workers' compensation status, primary diagnosis, preoperative neurologic status, number of levels fused, bone graft type, implants used, SSEP findings, postoperative neurologic status, complications, and recovery from complications were recorded. Final neurologic status was determined through phone contact with patients or outpatient charts of patients who could not be contacted personally. RESULTS: There were 3 false positive (1.8%) intraoperative SSEP findings in which SSEP changes intraoperatively did not reflect a neurologic deterioration after surgery. There was 1 false negative (0.6%) in which a new neurologic deficit occurred after surgery, despite no change in SSEP amplitudes during the operation. There were 2 true negatives (1.2%) in which SSEP monitoring showed a preexisting neurologic deficit, which did not change during the operation. CONCLUSION: In no instance were positive SSEP findings clinically useful in alerting the surgeon to potential intraoperative complications. Intraoperative SSEP monitoring is not helpful to the surgeon when performing routine ACDF. Additionally, ACDF is a safe procedure with a low rate of neurologic complications.

Adolescent↗

Spinal cord monitoring in scoliosis surgery using an epidural electrode. Results of a prospective, consecutive series of 191 cases.

STUDY DESIGN: Retrospective analysis of a prospectively accrued series of 191 consecutive patients who underwent intraoperative neurophysiologic monitoring during scoliosis corrective surgery. OBJECTIVES: To compare the monitoring outcome of idiopathic and neuromuscular scoliosis. To demonstrate the usefulness of the epidural electrode. To report sensitivity and specificity of the monitoring method employed at a single institution. SUMMARY OF BACKGROUND DATA: Reports in the literature emphasized the difficulty to obtain data in neuromuscular patients. Multimodality spinal cord monitoring has been recommended. Despite their still debated composition, neurogenic motor-evoked potentials have proven their validity in clinical practice. METHODS: Somatosensory and neurogenic evoked potentials were attempted in all patients presenting for scoliosis correction between 1999 and 2005. Study patients were divided into 3 groups: group 1, idiopathic; group 2, neuromuscular; and group 3, miscellaneous origins. RESULTS: The use of the epidural electrode demonstrated significant usefulness in the ability of monitoring otherwise nonmonitored patients, especially in group 2. Inability to obtain any evoked potentials occurred in 4 cases (2.1%). Five cases were found to be true positives. An adapted and rapid intervention permitted to avoid new postoperative deficit in all cases. There was no instance of false-negative data. The overall method sensitivity was 100%, and specificity was 52.69%. CONCLUSIONS: The use of a single epidural electrode allowing somatosensory evoked potentials recording and spinal cord stimulation alternately is a safe and valid method of intraoperative monitoring.

Adolescent↗

Molecular diagnostics of injury and repair responses in critical illness: what is the future of "monitoring" in the intensive care unit?

OBJECTIVE: To identify potential future means of monitoring injury and repair in critical illness. DESIGN: Review of the literature. RESULTS: Critically ill patients are monitored extensively and intensively by such means as hemodynamics, laboratory values, and radiologic studies. In general, however, the goal of monitoring has been to measure the degree of injury and to prevent further injury, rather than to measure repair. Measures of repair have been limited to phenotypic end points such as return of organ function, as measured by blood chemistry. In this article, I examine how it may be possible in the future to monitor the progress of repair using genomic and proteomic biomarkers. These types of monitors would enable clinicians to control the healing environment using real time, rapid biomarkers, and sophisticated techniques to target therapy to the patient's current inflammatory state, taking into account the genetic makeup of the patient and his or her likely response to a given drug. CONCLUSIONS: The rapidly evolving sciences of genomics, proteomics, computational biology, and complex system theory can be used a) to model critical illness; b) to model adaptive and maladaptive responses to critical illness; c) to tailor treatments to create an ideal inflammatory environment for repair and regeneration, taking into account the individual genetic contribution; and d) to monitor the progress of repair. The major obstacles to reaching these goals are technological, and experience suggests that they will be overcome.

Adaptation, Physiological↗

Clinical pharmacokinetic monitoring of itraconazole is warranted in only a subset of patients.

Itraconazole is a synthetic triazole antifungal agent that is commonly used in the prophylaxis and treatment of fungal infection. A role for itraconazole drug monitoring has been suggested previously; however, the advent of new formulations and increased clinical evidence may aid in further defining this role. Consequently, we have used a previously published decision-making algorithm to determine whether clinical pharmacokinetic monitoring of itraconazole is warranted. First, itraconazole has proven efficacy for the prophylaxis and treatment of fungal infection in immunocompromised individuals such as neutropenic cancer, human immunodeficiency virus (HIV), and solid organ transplant patients. Several assays have been developed to quantify itraconazole and its main metabolite in patient plasma. Measurement of these plasma drug levels in many clinical studies has resulted in no clear definition of a relationship between concentration and efficacy. However, limited evidence suggests a correlation between itraconazole levels greater than 250 or 500 ng/mL and increased efficacy. Clinical monitoring of efficacy is difficult because of the challenges in diagnosis of fungal infections and nonspecific clinical symptoms associated with fungal infections. Pharmacokinetic studies of itraconazole indicate that significant inter- and intrapatient variability exists in both healthy and immunocompromised patient populations, although subpopulations such as neutropenic cancer and HIV patients appear to require more drug than their healthy counterparts to attain similar drug levels. A therapeutic range has not been defined for itraconazole, but because of its relatively minimal side effects, a narrow range is unlikely. Drug interactions can occur with itraconazole because it is both an inhibitor and substrate of the cytochrome P450 3A4 (CYP3A4) enzyme and P-glycoprotein transporter systems. Protein binding alterations could also lead to differences in drug effect. Last, the duration of treatment of prophylaxis is significantly long to propose a potential benefit from drug monitoring. From weighing the available evidence, it appears that itraconazole drug level monitoring would provide more information on efficacy than clinical judgment alone in a subset of patients. Immunosuppressed patients requiring preventative therapy who have suspected poor absorption, are on concomitant enzyme inducers, or are suspected to be noncompliant would have the greatest benefit from itraconazole drug monitoring.

Antifungal Agents↗

The role of therapeutic monitoring of everolimus in solid organ transplantation.

Everolimus is a novel proliferation signal inhibitor used in immunosuppressive therapies for the prevention of acute and chronic rejection. A role for everolimus drug monitoring has been suggested because of the potential for improving efficacy and reducing adverse effects. Everolimus has proven efficacy for prevention of rejection in adult de novo renal and cardiac transplant recipients. Similar effects have been shown in pediatric renal transplant patients. Several analytic methods are available to quantify everolimus concentrations. A good relationship exists between everolimus concentration and pharmacological response. Mere clinical monitoring of efficacy is insufficient because clinical presentations of graft rejection vary for each patient and are nonspecific. Thus, the authors have used a previously published 9-step decision-making algorithm to evaluate the utility of therapeutic drug monitoring for everolimus. The recommended therapeutic range for everolimus is a trough concentration of 3 to 8 ng/mL, as concentrations over 3 ng/mL have been associated with a decreased incidence of rejection, and concentrations >8 ng/mL with increased toxicity. Everolimus exhibits interindividual pharmacokinetic variability. African American patients have higher apparent clearance, whereas patients with hepatic dysfunction or those on concomitant medications with potent cytochrome P450 (CYP) 3A4 inhibitor or inducer properties have lower or higher apparent clearance, respectively. Solid organ transplant recipients will likely be maintained on immunosuppressant therapy for the life of the graft and/or recipient and thus are likely to benefit from clinical pharmacokinetic monitoring. Based on the available evidence, therapeutic drug monitoring for everolimus may provide additional information on efficacy and safety than sound clinical judgment alone. Patients on everolimus who have problems with absorption, who take concurrent cytochrome P450 inhibitors or inducers, or are noncompliant will attain the greatest benefit from drug monitoring.

Area Under Curve↗

Nerve monitoring and stimulation during endoscopic neck surgery in the pig.

OBJECTIVES: To determine the feasibility of recurrent laryngeal nerve monitoring and stimulation during endoscopic neck surgery in an animal model. STUDY DESIGN: Prospective, nonrandomized experimental investigation in a porcine model. METHODS: Bilateral recurrent laryngeal nerve monitoring and stimulation was accomplished during endoscopic neck surgery in five domestic pigs. Each pig was intubated with an electromyography endotracheal tube. Recurrent laryngeal nerve function was monitored throughout the endoscopic neck surgery with a nerve integrity monitor system. An endoscopic surgical pocket was created in the neck using blunt dissection followed by low-pressure carbon dioxide insufflation. Under direct endoscopic visualization, the trachea, thyroid gland, and associated vasculature were identified. The recurrent laryngeal nerve was identified on each side of the animal and was successfully stimulated with a monopolar stimulator probe. RESULTS: Ten of ten recurrent laryngeal nerves were successfully monitored and stimulated. No significant complications were encountered during the procedures. CONCLUSIONS: Recurrent laryngeal nerve monitoring and stimulation may be successfully accomplished during endoscopic neck surgery.

Animals↗

Metabolomics in monitoring kidney transplants.

PURPOSE OF REVIEW: The success of any given kidney transplant is closely tied to the ability to monitor patients and responsively change their medications. Transplant monitoring is still, however, dependent on relatively old technologies: serum creatinine levels, urine output, blood pressure, blood glucose and histopathology of biopsy samples. These older technologies do not offer sufficient specificity, sensitivity, or accuracy to allow appropriate and timely interventions. Using the tools of genomics, proteomics and metabolomics new biomarkers are being found that may greatly improve transplant monitoring and significantly enhance graft survival. This review describes the basic principles of metabolomics and summarizes a number of recent developments in the use of metabolite biomarkers and metabolomics to monitor kidney transplants. RECENT FINDINGS: Changes in the concentration profiles of a number of small molecule metabolites found in either blood or urine can be used to localize organ damage, identify organs at risk of rejection, assess organs suffering from ischemia-repurfusion injury or identify organs that have been damaged by immunosuppressive drugs. SUMMARY: The application of metabolomics to kidney transplant monitoring is still very much in its infancy. Nevertheless, there are a number of easily measured metabolites in both urine and serum that can provide reliable indications of organ function, organ injury, and immunosuppressive drug toxicity. As the field matures, metabolomics may eventually lead to the development of rapid, inexpensive and noninvasive approaches to assist clinicians in monitoring kidney transplants.

Biomarkers↗

Novel monitoring techniques for use with procedural sedation.

PURPOSE OF REVIEW: A variety of pharmacologic agents used for procedural sedation in children to reduce pain and anxiety may produce respiratory depression and hypotension. Although standard monitoring guidelines include oxygen saturation, this measurement is limited as a guide to respiratory function. This review discusses two new monitoring techniques recently introduced to the pediatric emergency department that facilitate procedural sedation and reduce potential adverse effects of the medications administered. RECENT FINDINGS: Capnography via an end-tidal carbon dioxide monitor measures carbon dioxide concentrations during ventilation. This measurement is independent of oxygen saturation and thereby aids the clinician in identifying hypoventilation and apnea in the sedated patient at an earlier stage than conventional monitoring. The bispectral index monitor objectively measures the depth of sedation by analyzing electroencephalogram signals from a cutaneous probe. This tool enables the physician to titrate sedative medications to a desired effect and thereby reduce the risks associated with oversedation. SUMMARY: Studies have illustrated the use of both devices as adjuncts to current standard monitoring of children in the outpatient setting. These modalities will facilitate the efficacy of procedural sedation in children and improve safety by enabling early recognition of hypoventilation and by reducing the risk of oversedation in children undergoing procedural sedation.

Capnography↗

Frequency of intracranial pressure monitoring in infants and young toddlers with traumatic brain injury.

OBJECTIVE: To examine the use of intracranial pressure monitors and treatments for elevated intracranial pressure in brain-injured children of <2 yrs of age and compare them with the recently published management guidelines. DESIGN: Prospective, population-based study. SETTING: All pediatric intensive care units in the state of North Carolina. PATIENTS: All patients of <24 months of age admitted to a pediatric intensive care unit with a traumatic brain injury between January 2000 and December 2001. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Use of intracranial pressure monitoring devices and treatments for elevated intracranial pressure were measured. There were 136 children admitted to a pediatric intensive care unit with brain injury. A total of 54 (39.7%) had an admission Glasgow Coma Score of < or =8, and 80% were infants. Thirty-three percent of children with a Glasgow Coma Score of < or =8 received monitoring. Hyperosmolar therapy was the most frequently used treatment (57.1%). Treatment for elevated intracranial pressure was more common in, but not limited to, children with monitors. Logistic-regression modeling showed that children of < or =12 months of age had an odds ratio of 0.2 (95% confidence interval, 0.1-0.6) of receiving a monitor compared with children aged 12-24 months. CONCLUSIONS: Brain injury in young children may lead to many years of lost quality of life. The utility of monitoring intracranial pressure in infants has not been well established, which may be a reason for its low use. As most infants with traumatic brain injury survive, high-quality studies with neurodevelopmental measures as the primary outcome are urgently needed to document best practice in this subpopulation.

Age Factors↗

Comparison of cardiac outputs of major burn patients undergoing extensive early escharectomy: esophageal Doppler monitor versus thermodilution pulmonary artery catheter.

BACKGROUND: After major burn injury, severe hemodynamic fluctuations occur in a relatively short time, requiring invasive hemodynamic monitoring. The noninvasive esophageal Doppler monitor offers an alternative to the pulmonary artery catheter. This study compares the cardiac output of the esophageal Doppler monitor with that of a pulmonary artery catheter during the large volume shifts seen in extensive early escharectomy. METHODS: This study recruited 20 critically ill, major burn patients scheduled for elective early escharectomy. A thermodilution pulmonary artery catheter and esophageal Doppler monitor probes were inserted to measure cardiac output simultaneously at regular intervals. The results were analyzed by simple linear regression and Bland and Altman plots. RESULTS: The analysis included 92 data pairs from 20 patients, most of whom were critically ill with major burns. Escharectomy caused large intraoperative fluid shifts. The cardiac output of the esophageal Doppler monitor correlated moderately well with the cardiac output of the pulmonary artery, although it showed a mean of 15% less than the output of the pulmonary artery catheter. The mean bias was 0.77 L/minute, and the limits of agreement were +/-2.74 L/min. CONCLUSIONS: For major burn patients undergoing early escharectomy, the esophageal Doppler monitor allows changes in hemodynamics to be followed, but does not accurately measure the absolute values of cardiac output.

Adult↗

Multimodal brain monitoring in the neurological intensive care unit: where does continuous EEG fit in?

Continuous EEG (cEEG) is a vital component of patient monitoring in the neurologic intensive care unit, allowing the intensivist to diagnose nonconvulsive seizure activity. Though still in its infancy, Fourier-transformed cEEG data are also increasingly being used in ICUs to monitor global cerebral activity and cortical function. In conjunction with other components of multimodality neurologic monitoring, including intracranial pressure, cerebral blood flow, brain tissue oxygen tension monitoring, transcranial Doppler, and microdialysis monitoring, cEEG provides unique data regarding the electrical activity of the brain. The main challenge for clinicians and researchers will be to understand how these different aspects of multimodality monitoring relate to each other, and how physiologic variables such as blood pressure, osmolality, and temperature can be manipulated to optimize cerebral function and tissue survival in the setting of acute injury.

Brain↗