Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients--a review of 1,039 cases.

BACKGROUND CONTEXT: Intraoperative somatosensory evoked potential (SSEP) monitoring has been shown to reduce the incidence of new postoperative neurological deficits in scoliosis surgery. However, its usefulness during cervical spine surgery remains a subject of debate. PURPOSE: To determine the utility of intraoperative SSEP monitoring in a specific patient population (those with cervical radiculopathy in the absence of myelopathy) who underwent anterior cervical discectomy and fusion (ACDF) surgery. STUDY DESIGN: Retrospective review. PATIENT SAMPLE: A total of 1,039 nonmyelopathic patients who underwent single or multilevel ACDF surgery. The control group (462 patients) did not have intraoperative SSEP monitoring, whereas the monitored group (577 patients) had continuous intraoperative SSEP monitoring performed. OUTCOME MEASURE: A new postoperative neurological deficit. METHODS: SSEP tracings were reviewed for all 577 patients in the monitored group and all significant signal changes were noted. Medical records were reviewed for all 1,039 patients to determine if any new neurological deficits developed in the immediate postoperative period. RESULTS: None of the patients in the control group had any new postoperative neurological deficits. In the monitored group there were six instances of transient SSEP changes (1 due to suspected carotid artery compression; 5 thought to be due to transient hypotension) which resolved with the appropriate intraoperative intervention (repositioning of retractors; raising the arterial blood pressure). Upon waking up from anesthesia, one patient in the monitored group had a new neurological deficit (partial central cord syndrome) despite normal intraoperative SSEP signals. CONCLUSIONS: ACDF appears to be a safe surgical procedure with a low incidence of iatrogenic neurological injury. Transient SSEP signal changes, which improved with intraoperative interventions, were not associated with new postoperative neurological deficits. An intraoperative neurological deficit is possible despite normal SSEP signals.

Adult↗

Compartment pressure monitoring during intramedullary fixation of tibial fractures.

Twenty-six legs in 25 patients were monitored prospectively for compartment pressures during intramedullary nailing of open and closed tibial shaft fractures. Twenty-three patients were treated within 24 hours of admission. Twenty-three unreamed and three reamed intramedullary rods were utilized. Compartment pressures were measured initially, following fracture reduction, and during reaming. Pressures were also measured at the completion of nailing with the ankle dorsiflexed and at rest (plantar flexed) to determine positional effects on compartment pressures. Nine fractures (35%) were found to have persistently elevated pressures (> 40 mm Hg) and underwent immediate four-compartment fasciotomy. The remaining group of 17 fractures (65%) was monitored throughout the intraoperative period. No patient monitored intraoperatively developed postoperative compartment syndrome.

Adolescent↗

Intraoperative somatosensory evoked potential monitoring during cervical spine corpectomy surgery: experience with 508 cases.

STUDY DESIGN: Retrospective review. OBJECTIVES: To review consecutive cases of cervical spine corpectomy surgery performed with intraoperative somatosensory-evoked potential (SSEP) monitoring. SUMMARY OF BACKGROUND DATA: There is controversy about the utility of SSEP monitoring during anterior cervical spine surgery. There is no study in the literature that has specifically evaluated the utility of SSEP monitoring for cervical spine corpectomy surgery. METHODS: Intraoperative SSEP tracings for 508 patients (average age, 55.7 years; 268 male, 240 female) who underwent anterior cervical fusion with single-level or multilevel corpectomies were reviewed. Intraoperative and postoperative records were analyzed to determine if any new neurologic deficits developed when the patients woke up from anesthesia. RESULTS: The overall incidence of a new postoperative neurologic deficit in this series of patients was 2.4% (11 with nerve root injury, 1 with quadriplegia). The incidence of significant SSEP changes was 5.3% (27 of 508 patients). The most common identifiable cause of SSEP changes was hypotension, and the most common neurologic deficit was deltoid (C5) weakness. One patient had irreversible SSEP changes, and he woke up with new-onset quadriplegia. The calculated sensitivity and specificity of intraoperative SSEP monitoring for detecting impending or resultant intraoperative iatrogenic neurologic injury were 77.1% and 100%, respectively. However, if the isolated nerve root injuries are removed from the analysis, then both the calculated sensitivity and the negative predictive values were 100%. CONCLUSIONS: Intraoperative SSEP monitoring can alert the surgeon to adverse iatrogenic intraoperative events with potential for neurologic injury. Most SSEP signal changes are reversible and do not result in a clinical deficit. Isolated nerve root injury appears to be the most common iatrogenic intraoperative injury during cervical spine corpectomy surgery.

Adult↗

[Spinal cord evoked potential].

Spinal cord evoked potentials (SCEPs) used as a technique for intraoperative neurophysiological monitoring can be divided into several groups depending on the stimulation method. SCEP evoked by direct motor cortex stimulation enables the recording of the descending volley passing through the corticospinal tract. Such potentials are termed D (direct)- and I (indirect)-waves. D-wave reflects the function of the corticospinal tract directly and is regarded as an appropriate parameter for the intraoperative monitoring of motor function. On the other hand, the corticospinal tract may be activated by transcranial stimulation and a potential similar to D-wave can be recorded from the spinal epidural space. Previous studies, however, indicated that the site of transcranial stimulation is around the lower level of the brainstem and the response includes the potentials coming from other neural tracts. In addition, the responses of SCEPs evoked by spinal cord and peripheral nerve stimulations are generally considered to reflect mainly the function of the deep sensory pathway. Therefore, SCEPs evoked by transcranial, spinal cord and peripheral nerve stimulations cannot be used as a parameter to monitor motor function directly. It is particularly important to know the characteristics of each SCEP and apply each potential to the most appropriate situation.

Evoked Potentials↗

[New development of surgical treatment for malignant brain tumors].

The most important prognosticator for malignant brain tumor patients is the degree of tumor removal. On the other hand, surgical removal should not induce aggravation of the patient performance status. In accordance with the result, surgical planning for glioma should be carefully considered. However, there is no standard guide for preoperative planning to date. However, there is no standard guide for preoperative planning to the present. We attempted to divide gliomas into 5 stages according to the difficulty of the surgery and analyzed the relation between the removal rate and each stage. The results demonstrated that the stage is correlated with the removal rate. This staging might contribute to standardization of glioma surgery. For surgical planning of tumors around the motor area, fiber tractography and magnetoencephalography should be very useful. As an intraoperative examination, monitoring of motor evoked potential is necessary to resect tumors around the motor area. For resection of tumors around the speech area, functional brain mapping under awake surgery is the most reliable method. In addition to these techniques for safe surgery, neuro-navigation and chemical navigation using 5-aminolevulinic acid are used to achieve of the maximum removal rate. Finally, development of preoperative examinations, microsurgical technique, and intraoperative monitoring enabled us to do safer and move sure surgery.

Astrocytoma↗

Recording of spinal somatosensory evoked potentials for intraoperative spinal cord monitoring.

The authors' experience with intradural and epidural recording of spinal somatosensory evoked potentials (SSEP's) during 26 cases of spinal surgery is described. The techniques of monitoring spinal cord function provided good quality SSEP waveforms in patients both with and without neurological deficits. The SSEP configuration and peak latencies remained stable for up to 5 hours during anesthesia with nitrous oxide, halothane, and fentanyl. Patterns of baseline SSEP's were characteristic of different spinal segments. Distortion and asymmetry of these baseline patterns were seen in several patients with spinal neoplasms. Loss of waveform components during surgery occurred with profound hypotension, overdistraction of the vertebral axis, dorsal midline myelotomy, and removal of intramedullary tumors. Persistent loss of waveform components was associated with an acquired neurological deficit. Fluctuations in the amplitude of the SSEP's were common but were not associated with postoperative neurological deficits. Spinal cord monitoring by means of SSEP recording would appear to be useful during extradural spinal surgery, but there are limitations associated with this technique during some types of intradural surgery.

Adolescent↗

Tympanic and transtympanic electrocochleography in acoustic neuroma and vestibular nerve section surgery.

Eighth nerve action potential (AP) amplitudes and latencies and cochlear microphonic (CM) amplitudes were compared using tympanic and transtympanic electrocochleography (ECOG) in two patient groups. Tympanic ECOG was performed with a wick electrode placed on the tympanic membrane (TM). Transtympanic ECOG was performed with a needle electrode placed on the promontory of the anesthetized patient. Eighteen subjects were tested by tympanic ECOG as part of a preoperative assessment for either acoustic neuroma removal or transection of the vestibular portion of the eighth cranial nerve. Surgery occurred within 1 week of the preoperative evaluation. Intraoperative auditory monitoring was performed using transtympanic ECOG. Baseline recordings were compared to the preoperative tympanic ECOG data. Stimuli were condensation and rarefaction clicks and tone bursts, presented by an insert earphone. As expected, the two methods resulted in essentially identical response latencies and large amplitude differences, although the response amplitudes were extremely variable. The AP amplitude and the CM amplitude did not increase by the same factor with the transtympanic (TT) electrode compared to the tympanic electrode. On comparison of preoperative and intraoperative response amplitudes with regard to stimulus polarity, tympanic electrocochleography appears to be a useful method of gathering preliminary information on the status of the patient's auditory system. In this study, tympanic ECOG was found to have some predictive value when trying to ascertain the best intraoperative monitoring situation.

Acoustic Stimulation↗

Impact of somatosensory evoked potential monitoring on cervical surgery.

Controversy still exists about the necessity of somatosensory evoked potential (SSEP) monitoring during cervical surgery. The purpose of this prospective study is to determine the impact of SSEP monitoring on anterior cervical surgery. Intraoperative SSEP monitoring was performed in 100 patients treated by an anterior cervical approach. The patients were divided into three groups according to their preoperative clinical condition. Somatosensory evoked potential monitoring was performed during five stages of the procedure: M1, after the induction of anesthesia; M2, during positioning; M3, during distraction of the intervertebral space; M4, throughout decompression; and M5, during graft placement. Normal SSEPs were obtained during M1 from all the patients in group 2. Pathologic SSEPs were recorded at M1 in 45 patients from group 1. No SSEPs were recorded at M1 in six patients in group 3. A deterioration of the SSEPs was observed in 35 patients during M2. Deteriorated SSEPs were observed during M3 in 14 patients. No deterioration of the SSEPs was recorded during M4. Intraoperative SSEP monitoring is easy to perform and helps to increase safety during anterior cervical surgery. Critical phases of the surgical procedure were identified and the surgical strategy was modified as a result of this study.

Cervical Vertebrae↗

Continuous transcranial Doppler ultrasonography and electroencephalography during carotid endarterectomy: a multimodal monitoring system to detect intraoperative ischemia.

Transcranial Doppler ultrasonography (TCD) and EEG monitoring during carotid endarterectomy provide continuous information on the electrical activity of the cerebral cortex, blood flow velocities in the ipsilateral middle cerebral artery, and the occurrence of microemboli. One hundred thirty carotid endarterectomies performed with TCD and EEG monitoring were studied prospectively. During cross-clamping of the carotid artery a high correlation was found between EEG asymmetry and reduction of blood flow velocity in the middle cerebral artery (p < 10(-6), Student's t test). Microemboli were detected in 80 patients during the operation. Although not statistically significant, this occurrence of microemboli was associated with signs and symptoms of intraoperative ischemia (p = 0.08, Fisher's exact test). In comparison with earlier studies, a tendency toward intraoperative stroke reduction was noted. Only one nondisabling intraoperative stroke occurred (0.8%). In addition to the EEG, TCD monitoring of hemodynamic changes and microemboli in the middle cerebral artery provides important information to the surgeon instantaneously. TCD monitoring of blood flow velocities and embolism during carotid endarterectomy may help to reduce the number and gravity of intraoperative stroke.

Adult↗

New technology and methodologies for intraoperative, perioperative, and intraprocedural monitoring of surgical and catheter interventions for congenital heart disease.

We review the new technology and methods available for support of intraoperative and intraprocedural imaging in the catheterization laboratory for surgical and interventional catheterization procedures in the treatment of congenital heart disease. The methods reviewed include miniaturized probes and new ways of using them perioperatively for cardiac imaging from transesophageal, substernal, and intracardiac imaging locations. The smaller and more versatile the probes, the better adapted they will be in providing methods to improve the outcomes in babies born with serious forms of congenital heart disease.

Cardiac Surgical Procedures↗

Axillary nerve monitoring during arthroscopic shoulder stabilization.

PURPOSE: This study evaluated the ability of a novel intraoperative neurophysiologic monitoring method used to locate the axillary nerve, predict relative capsule thickness, and identify impending injury to the axillary nerve during arthroscopic thermal capsulorrhaphy of the shoulder. TYPE OF STUDY: Prospective cohort study. METHODS: Twenty consecutive patients with glenohumeral instability were monitored prospectively during arthroscopic shoulder surgery. Axillary nerve mapping and relative capsule thickness estimates were recorded before the stabilization portion of the procedure. During labral repair and/or thermal capsulorrhaphy, continuous and spontaneous electromyography recorded nerve activity. In addition, trans-spinal motor-evoked potentials of the fourth and fifth cervical roots and brachial plexus electrical stimulation, provided real-time information about nerve integrity. RESULTS: Axillary nerve mapping and relative capsule thickness were recorded in all patients. Continuous axillary nerve monitoring was successfully performed in all patients. Eleven of the 20 patients underwent thermal capsulorrhaphy alone or in combination with arthroscopic labral repair. Nine patients underwent arthroscopic labral repair alone. In 4 of the 11 patients who underwent thermal capsulorrhaphy, excessive spontaneous neurotonic electromyographic activity was noted, thereby altering the pattern of heat application by the surgeon. In 1 of these 4 patients, a small increase in the motor latency was noted after the procedure but no clinical deficit was observed. There were no neuromonitoring or clinical neurologic changes observed in the labral repair group without thermal application. At last follow-up, no patient in either group had any clinical evidence of nerve injury or complications from neurophysiologic monitoring. CONCLUSIONS: We successfully evaluated the use of intraoperative nerve monitoring to identify axillary nerve position, capsule thickness, and provide real-time identification of impending nerve injury and function during shoulder thermal capsulorrhaphy. The use of intraoperative nerve monitoring altered the heat application technique in 4 of 11 patients and may have prevented nerve injury. LEVEL OF EVIDENCE: Level II, prospective cohort study.

Adolescent↗