PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Pitch Perception”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

Spectral and temporal cues to pitch in noise-excited vocoder simulations of continuous-interleaved-sampling cochlear implants.

Four-band and single-band noise-excited vocoders were used in acoustic simulations to investigate spectral and temporal cues to melodic pitch in the output of a cochlear implant speech processor. Noise carriers were modulated by amplitude envelopes extracted by half-wave rectification and low-pass filtering at 32 or 400 Hz. The four-band, but not the single-band processors, may preserve spectral correlates of fundamental frequency (F0). Envelope smoothing at 400 Hz preserves temporal correlates of F0, which are eliminated with 32-Hz smoothing. Inputs to the processors were sawtooth frequency glides, in which spectral variation is completely determined by F0, or synthetic diphthongal vowel glides, whose spectral shape is dominated by varying formant resonances. Normal listeners labeled the direction of pitch movement of the processed stimuli. For processed sawtooth waves, purely temporal cues led to decreasing performance with increasing F0. With purely spectral cues, performance was above chance despite the limited spectral resolution of the processors. For processed diphthongs, performance with purely spectral cues was at chance, showing that spectral envelope changes due to formant movement obscured spectral cues to F0. Performance with temporal cues was poorer for diphthongs than for sawtooths, with very limited discrimination at higher F0. These data suggest that, for speech signals through a typical cochlear implant processor, spectral cues to pitch are likely to have limited utility, while temporal envelope cues may be useful only at low F0.

Adult↗

Psychophysical recovery from pulse-train forward masking in electric hearing.

Psychophysical pulse-train forward-masking (PTFM) recovery functions were measured in fifteen subjects with the Nucleus mini-22 cochlear implant and six subjects with the Clarion cochlear implant. Masker and probe stimuli were 500-Hz trains of 200- or 77-micros/phase biphasic current pulses. Electrode configurations were bipolar for Nucleus subjects and monopolar for Clarion subjects. Masker duration was 320 ms. Probe duration was either 10 ms or 30 ms. Recovery functions were measured for a high-level masker on a middle electrode in all 21 subjects, on apical and basal electrodes in 7 of the Nucleus and 3 of the Clarion subjects, and for multiple masker levels on the middle electrode in 8 Nucleus subjects and 6 Clarion subjects. Recovery functions were described by an exponential process in which threshold shift (in microA) decreased exponentially with increasing time delay between the offset of the masker pulse train and the offset of the probe pulse train. All but 3 of the 21 subjects demonstrated recovery time constants on a middle electrode that were less than 95 ms. The mean time constant for these 18 subjects was 54 ms (s.d. 17 ms). Three other subjects tested on three electrodes exhibited time constants larger than 95 ms from an apical electrode only. Growth-of-masking slopes depended upon time delay, as expected from an exponential recovery process, i.e., progressively shallower slopes were observed at time delays of 10 ms and 50 ms. Recovery of threshold shift (in microA) for PTFM in electrical hearing behaves inthe same way as recovery of threshold shift (in dB) for pure-tone forward masking in acoustic hearing. This supports the concept that linear microamps are the electrical equivalent of acoustic decibels. Recovery from PTFM was not related to speech recognition in a simple manner. Three subjects with prolonged PTFM recovery demonstrated poor speech scores. The remaining subjects with apparently normal PTFM recovery demonstrated speech scores ranging from poor to excellent. Findings suggest that normal PTFM recovery is only one of several factors associated with good speech recognition in cochlear-implant listeners. Comparisons of recovery curves for 10- and 30-ms probe durations in two subjects showed little or no temporal integration at time delays less than 95 ms where recovery functions have steep slopes. The same subjects exhibited large amounts of temporal integration at longer time delays where recovery slopes are more gradual. This suggests that probe detection depends primarily on detection of the final pulses in the probe stimulus and supports the use of offset-to-offset time delays for characterizing PTFM recovery in electric hearing.

Adult↗

Spectro-temporal processing in the envelope-frequency domain.

The frequency selectivity for amplitude modulation applied to tonal carriers and the role of beats between modulators in modulation masking were studied. Beats between the masker and signal modulation as well as intrinsic envelope fluctuations of narrow-band-noise modulators are characterized by fluctuations in the "second-order" envelope (referred to as the "venelope" in the following). In experiment 1, masked threshold patterns (MTPs), representing signal modulation threshold as a function of masker-modulation frequency, were obtained for signal-modulation frequencies of 4, 16, and 64 Hz in the presence of a narrow-band-noise masker modulation, both applied to the same sinusoidal carrier. Carrier frequencies of 1.4, 2.8, and 5.5 kHz were used. The shape and relative bandwidth of the MTPs were found to be independent of the signal-modulation frequency and the carrier frequency. Experiment 2 investigated the extent to which the detection of beats between signal and masker modulation is involved in tone-in-noise (TN), noise-in-tone (NT), and tone-in-tone (TT) modulation masking, whereby the TN condition was similar to the one used in the first experiment. A signal-modulation frequency of 64 Hz, applied to a 2.8-kHz carrier, was tested. Thresholds in the NT condition were always lower than in the TN condition, analogous to the masking effects known from corresponding experiments in the audio-frequency domain. TT masking conditions generally produced the lowest thresholds and were strongly influenced by the detection of beats between the signal and the masker modulation. In experiment 3, TT masked-threshold patterns were obtained in the presence of an additional sinusoidal masker at the beat frequency. Signal-modulation frequencies of 32, 64, and 128 Hz, applied to a 2.8-kHz carrier, were used. It was found that the presence of an additional modulation at the beat frequency hampered the subject's ability to detect the envelope beats and raised thresholds up to a level comparable to that found in the TN condition. The results of the current study suggest that (i) venelope fluctuations play a similar role in modulation masking as envelope fluctuations do in spectral masking, and (ii) envelope and venelope fluctuations are processed by a common mechanism. To interpret the empirical findings, a general model structure for the processing of envelope and venelope fluctuations is proposed.

Adult↗

Measuring hearing in the harbor seal (Phoca vitulina): comparison of behavioral and auditory brainstem response techniques.

Auditory brainstem response (ABR) and standard behavioral methods were compared by measuring in-air audiograms for an adult female harbor seal (Phoca vitulina). Behavioral audiograms were obtained using two techniques: the method of constant stimuli and the staircase method. Sensitivity was tested from 0.250 to 30 kHz. The seal showed good sensitivity from 6 to 12 kHz [best sensitivity 8.1 dB (re 20 microPa2 x s) RMS at 8 kHz]. The staircase method yielded thresholds that were lower by 10 dB on average than the method of constant stimuli. ABRs were recorded at 2, 4, 8, 16, and 22 kHz and showed a similar best range (8-16 kHz). ABR thresholds averaged 5.7 dB higher than behavioral thresholds at 2, 4, and 8 kHz. ABRs were at least 7 dB lower at 16 kHz, and approximately 3 dB higher at 22 kHz. The better sensitivity of ABRs at higher frequencies could have reflected differences in the seal's behavior during ABR testing and/or bandwidth characteristics of test stimuli. These results agree with comparisons of ABR and behavioral methods performed in other recent studies and indicate that ABR methods represent a good alternative for estimating hearing range and sensitivity in pinnipeds, particularly when time is a critical factor and animals are untrained.

Animals↗

A second, low-frequency mode of vibration in the intact mammalian cochlea.

The mammalian cochlea is a structure comprising a number of components connected by elastic elements. A mechanical system of this kind is expected to have multiple normal modes of oscillation and associated resonances. The guinea pig cochlear mechanics was probed using distortion components generated in the cochlea close to the place of overlap between two tones presented simultaneously. Otoacoustic emissions at frequencies of the distortion components were recorded in the ear canal. The phase behavior of the emissions reveals the presence of a nonlinear resonance at a frequency about a half octave below that of the high-frequency primary tone. The location of the resonance is level dependent and the resonance shifts to lower frequencies with increasing stimulus intensity. This resonance is thought to be associated with the tectorial membrane. The resonance tends to minimize input to the cochlear receptor cells at frequencies below the high-frequency primary and increases the dynamic load to the stereocilia of the receptor cells at the primary frequency when the tectorial membrane and reticular lamina move in counterphase.

Acoustic Stimulation↗

The balanced electromagnetic separation transducer a new bone conduction transducer.

Conventional bone conduction transducers, which are relatively large, suffer from poor performance at low frequencies. A new type of electro-dynamic transducer, the balanced electromagnetic separation transducer (BEST), was developed to improve the performance of the conventional transducers. By using a balanced suspension principle, the quadratic distortion forces, as well as the static forces between the vibrating parts, are principally counterbalanced. Both the distortion and the size of the transducer can therefore be considerably reduced. Moreover, the static and dynamic magnetic fluxes are separated, except in the air gap regions, giving a more efficient transducer. For example, in comparison with a conventional B71 transducer, a prototype of the BEST has: Lower total harmonic distortion (THD), by 20-25 dB, and improved sensitivity by 10-20 dB for 100 to 1000 Hz and by 2-10 dB for 1 to 10 kHz. From a clinical point of view, the BEST offers a chance to measure bone thresholds, at 250 and 500 Hz, which are reliable at hearing levels not possible before. For example, at 250 Hz the BEST has 23 dB higher sensitivity than the B71; the THD is improved from 61% (B71) to 3.3% (BEST) at 40 dB HL (ISO 389-3, 1994).

Audiometry, Pure-Tone↗

Informational masking caused by contralateral stimulation.

Although informational masking is thought to reflect central mechanisms, the effects are generally much stronger when the target and masker are presented to the same ear than when they are presented to different ears. However, the results of a recent study by Brungart and Simpson [J. Acoust. Soc. Am. 112, 2985-2995 (2002)] indicated that a speech masker that is presented contralateral to a speech signal can produce substantial amounts of informational masking when a second speech masker is played simultaneously in the same ear as the signal. In this study, we conducted a series of experiments that paralleled those of Brungart and Simpson but used a pure-tone signal and multitone informational maskers in a detection task. Both the signal and the maskers were played as sequences of short bursts in each observation interval. The maskers were arranged in two types of spectrotemporal patterns. One type of pattern, called "multiple-bursts same" (MBS), has previously been shown to produce very large amounts of informational masking while the other type of pattern, called "multiple-bursts different" (MBD), has been shown to produce very small amounts of informational masking. Several conditions of ipsilateral, contralateral, and combined presentation of these maskers were tested. The results showed that presentation of the MBS masker in the contralateral ear produced a substantial amount of informational masking when the MBD masker was simultaneously presented to the ipsilateral ear. The results supported the earlier findings of Brungart and Simpson indicating that listeners are unable to selectively focus their attention on a single ear in some complex dichotic listening conditions. These results suggest that this contralateral masking effect is not restricted to speech and may reflect more general limitations on processing capacity. Further, it was concluded that the magnitude of the contralateral masking effect was related both to the informational masking value of the contralateral masker and the complexity of the stimulus and/or task in the ear in which the signal was presented.

Adolescent↗

The effects of hearing loss on the contribution of high- and low-frequency speech information to speech understanding.

The speech understanding of persons with "flat" hearing loss (HI) was compared to a normal-hearing (NH) control group to examine how hearing loss affects the contribution of speech information in various frequency regions. Speech understanding in noise was assessed at multiple low- and high-pass filter cutoff frequencies. Noise levels were chosen to ensure that the noise, rather than quiet thresholds, determined audibility. The performance of HI subjects was compared to a NH group listening at the same signal-to-noise ratio and a comparable presentation level. Although absolute speech scores for the HI group were reduced, performance improvements as the speech and noise bandwidth increased were comparable between groups. These data suggest that the presence of hearing loss results in a uniform, rather than frequency-specific, deficit in the contribution of speech information. Measures of auditory thresholds in noise and speech intelligibility index (SII) calculations were also performed. These data suggest that differences in performance between the HI and NH groups are due primarily to audibility differences between groups. Measures of auditory thresholds in noise showed the "effective masking spectrum" of the noise was greater for the HI than the NH subjects.

Adult↗

Modulation masking in cochlear implant listeners: envelope versus tonotopic components.

It is hypothesized that channel-interaction in cochlear implant listeners as measured in a modulation-masking experiment would be influenced by both the tonotopic overlap between masker and signal as well as an interaction between their envelopes. Two experiments were conducted to measure the effects of maskers with noisy and steady-state envelopes on modulation detection by four adult Nucleus-22 cochlear implant listeners, as a function of tonotopic distance between the masker and the signal. In the first experiment, we measured detection thresholds for a 50-Hz modulation in the envelope of a 500-Hz carrier pulse train, in the presence of a masker stimulating regions basal and apical to, as well as overlapping with, the signal. The maskers had two kinds of envelopes: (i) amplitude-modulated by flat-spectrum noise (NAM) and (ii) steady-state (SS(peak)) at a level corresponding to the maximum of the noise fluctuation range. In general, modulation thresholds obtained in the presence of the NAM maskers significantly exceeded thresholds obtained with the corresponding SS(peak) maskers. The ratio p of the threshold modulation depth m obtained with the NAM masker to that obtained with the SS(peak) masker was defined as a conservative index of "envelope masking." In the second experiment, p was determined for two different tasks: the detection of modulation at 20 Hz and steady-state intensity increment detection. Compared to the 50-Hz modulation detection results, the ratio p was reduced for the 20-Hz modulation detection task and even more so for the steady-state increment detection task. It is concluded that channel-interaction can be significantly increased in cochlear implant listeners when dynamic stimuli are used in place of steady-state stimuli.

Adult↗

Diversity in noise-induced temporary hearing loss in otophysine fishes.

The effects of intense white noise (158 dB re 1 microPa for 12 and 24 h) on the hearing abilities of two otophysine fish species--the nonvocal goldfish Carassius auramus and the vocalizing catfish Pimelodus pictus--were investigated in relation to noise exposure duration. Hearing sensitivity was determined utilizing the auditory brainstem response (ABR) recording technique. Measurements in the frequency range between 0.2 and 4.0 kHz were conducted prior and directly after noise exposure as well as after 3, 7, and 14 days of recovery. Both species showed a significant loss of sensitivity (up to 26 dB in C. auratus and 32 dB in P. pictus) immediately after noise exposure, with the greatest hearing loss in the range of their most sensitive frequencies. Hearing loss differed between both species, and was more pronounced in the catfish. Exposure duration had no influence on hearing loss. Hearing thresholds of C. auratus recovered within three days, whereas those of P. pictus only returned to their initial values within 14 days after exposure in all but one frequency. The results indicate that hearing specialists are affected differently by noise exposure and that acoustic communication might be restricted in noisy habitats.

Acoustic Stimulation↗

Speech recognition under conditions of frequency-place compression and expansion.

In normal acoustic hearing the mapping of acoustic frequency information onto the appropriate cochlear place is a natural biological function, but in cochlear implants it is controlled by the speech processor. The cochlear tonotopic range of the implant is determined by the length and insertion depth of the electrode array. Conventional cochlear implant electrode arrays are designed for an insertion of 25 mm inside the round window and the active electrodes occupy 16 mm, which would place the electrodes in a cochlear region corresponding to an acoustic frequency range of 500-6000 Hz. However, some implant speech processors map an acoustic frequency range from 150 to 10000 Hz onto these electrodes. While this mapping preserves the entire range of acoustic frequency information, it also results in a compression of the tonotopic pattern of speech information delivered to the brain. The present study measured the effects of such a compression of frequency-to-place mapping on speech recognition using acoustic simulations. Also measured were the effects of an expansion of the frequency-to-place mapping, which produces an expanded representation of speech in the cochlea. Such an expanded representation might improve speech recognition by improving the relative spatial (tonotopic) resolution, like an "acoustic fovea." Phoneme and sentence recognition was measured as a function of linear (in terms of cochlear distance) frequency-place compression and expansion. These conditions were presented to normal-hearing listeners using a noise-band vocoder, simulating cochlear implant electrodes with different insertion depths and different number of electrode channels. The cochlear tonotopic range was held constant by employing the same noise carrier bands for each condition, while the analysis frequency range was either compressed or expanded relative to the carrier frequency range. For each condition, the result was compared to that of the perfect frequency-place match, where the carrier and the analysis bands were perfectly matched. Speech recognition in the matched conditions was generally better than any condition of frequency-place expansion and compression, even when the matched condition eliminated a considerable amount of acoustic information. This result suggests that speech recognition, at least without training, is dependent on the mapping of acoustic frequency information onto the appropriate cochlear place.

Adult↗

Transient emission suppression tuning curve attributes in relation to psychoacoustic threshold.

Ipsilateral suppression characteristics of transiently evoked otoacoustic emissions (TEOAEs) are described in relation to psychoacoustic threshold at 4000 Hz and the presence or absence of spontaneous otoacoustic emissions in 41 adults with normal hearing. TEOAE amplitudes were measured in response to 4000-Hz tonebursts presented in linear blocks at 40 and 50 dB SPL while puretone suppressors were introduced at a variety of frequencies and levels ipsilateral to and simultaneously with the tonebursts. Suppressors close to the toneburst frequency were most effective in decreasing the amplitude of the TEOAEs, while those more remote in frequency required significantly greater intensity for a similar amount of suppression. Consequently, characteristic tuning curve shapes were obtained. Tuning-curve tip levels were closely associated with the level of the toneburst and tip frequencies occurred at or above the toneburst frequency. Tuning-curve widths (Q10), however, varied significantly across subjects with similar psychoacoustic thresholds in quiet determined by a two-alternative forced-choice method. The results suggest that a portion of that variability may be explained by the presence or absence of spontaneous otoacoustic emissions in an individual ear.

Acoustic Stimulation↗

Examination of a linear model in an informational masking study.

When multitone maskers are used in a two-interval, forced choice experiment, the amount of masking is larger when the masker is randomly chosen on each presentation interval compared to on each trial (the same masker in the two listening intervals). These conditions are referred to as having within- versus between-trial randomization. If it is assumed that an observer's ultimate detection decision depends on a single decision variable (DV), it is probable that the DV's variance will be substantially larger in the within-trial randomization condition compared to the between-trial randomization condition. The goal of the current experiment is to evaluate the degree to which this stimulus-based change in DV variance can account for the difference in thresholds in the within-versus between-trial randomization conditions. Thresholds are measured for the detection of a tone added to a six-component masker in between- and within-trial randomization conditions. The slopes of the psychometric functions provide an estimate of the variance in the DV for the between- and within-trial randomization conditions. Additionally, a channel model is fitted to the psychophysical results in the within-trial randomization condition. The resulting model is then used to predict the value of the DV for each trial, and ultimately to estimate the proportion of the total variance in the within-trial randomization condition that is attributable to changes in maskers across intervals. The variance of the DV in the between-trial randomization condition accounted for approximately 65% of the total variance in the DV in the within-trial randomization condition. Stimulus-based interval-by-interval masker randomization accounted for approximately 20% of the total variance of the within-trial randomization DV. The remaining 15% of the DV variance in the within-trial randomization condition remained unaccounted for. This result is fairly stable whether the maskers are drawn from a small versus large pool of potential maskers.

Attention↗

Effects of simulated cochlear-implant processing on speech reception in fluctuating maskers.

This study investigated the effects of simulated cochlear-implant processing on speech reception in a variety of complex masking situations. Speech recognition was measured as a function of target-to-masker ratio, processing condition (4, 8, 24 channels, and unprocessed) and masker type (speech-shaped noise, amplitude-modulated speech-shaped noise, single male talker, and single female talker). The results showed that simulated implant processing was more detrimental to speech reception in fluctuating interference than in steady-state noise. Performance in the 24-channel processing condition was substantially poorer than in the unprocessed condition, despite the comparable representation of the spectral envelope. The detrimental effects of simulated implant processing in fluctuating maskers, even with large numbers of channels, may be due to the reduction in the pitch cues used in sound source segregation, which are normally carried by the peripherally resolved low-frequency harmonics and the temporal fine structure. The results suggest that using steady-state noise to test speech intelligibility may underestimate the difficulties experienced by cochlear-implant users in fluctuating acoustic backgrounds.

Acoustic Stimulation↗

Dichotic speech recognition in noise using reduced spectral cues.

It is generally accepted that the fusion of two speech signals presented dichotically is affected by the relative onset time. This study investigated the hypothesis that spectral resolution might be an additional factor influencing spectral fusion when the spectral information is split and presented dichotically to the two ears. To produce speech with varying degrees of spectral resolution, speech materials embedded in +5 dB S/N speech-shaped noise were processed through 6-12 channels and synthesized as a sum of sine waves. Two different methods of splitting the spectral information were investigated. In the first method, the odd-index channels were presented to one ear and the even-index channels to the other ear. In the second method the lower frequency channels were presented to one ear and the high-frequency channels to the other ear. Results indicated that spectral resolution did affect spectral fusion, and the effect differed across speech materials, with the sentences being affected the most. Sentences, processed through six or eight channels and presented dichotically in the low-high frequency condition were not fused as accurately as when presented monaurally. Sentences presented dichotically in the odd-even frequency condition were identified more accurately than when presented in the low-high condition.

Acoustic Stimulation↗

Auditory masking in three pinnipeds: aerial critical ratios and direct critical bandwidth measurements.

This study expands the limited understanding of pinniped aerial auditory masking and includes measurements at some of the relatively low frequencies predominant in many pinniped vocalizations. Behavioral techniques were used to obtain aerial critical ratios (CRs) within a hemianechoic chamber for a northern elephant seal (Mirounga angustirostris), a harbor seal (Phoca vitulina), and a California sea lion (Zalophus californianus). Simultaneous, octave-band noise maskers centered at seven test frequencies (0.2-8.0 kHz) were used to determine aerial CRs. Narrower and variable bandwidth masking noise was also used in order to obtain direct critical bandwidths (CBWs). The aerial CRs are very similar in magnitude and in frequency-specific differences (increasing gradually with test frequency) to underwater CRs for these subjects, demonstrating that pinniped cochlear processes are similar both in air and water. While, like most mammals, these pinniped subjects apparently lack specialization for enhanced detection of specific frequencies over masking noise, they consistently detect signals across a wide range of frequencies at relatively low signal-to-noise ratios. Direct CBWs are 3.2 to 14.2 times wider than estimated based on aerial CRs. The combined masking data are significant in terms of assessing aerial anthropogenic noise impacts, effective aerial communicative ranges, and amphibious aspects of pinniped cochlear mechanics.

Acoustic Stimulation↗

Audio-vocal responses to repetitive pitch-shift stimulation during a sustained vocalization: improvements in methodology for the pitch-shifting technique.

The pitch-shift reflex is a sophisticated system that produces a "compensatory" response in voice F0 that is opposite in direction to a change in voice pitch feedback (pitch-shift stimulus), thus correcting for the discrepancy between the intended voice F0 and the feedback pitch. In order to more fully exploit the pitch-shift reflex as a tool for studying the influence of sensory feedback mechanisms underlying voice control, the optimal characteristics of the pitch-shift stimulus must be understood. The present study was undertaken to assess the effects of altering the duration of the interstimulus interval (ISI) and the number of trials comprising an average on measures of the pitch-shift reflex. Pitch-shift stimuli were presented to vocalizing subjects with ISI of 5.0, 2.5, 1.0, and 0.5 s to determine if an increase in ISI altered response properties. With each ISI, measures of event-related averages of the first 10, 15, 20, or 30 pitch-shift reflex responses were compared to see if increases in the number of responses comprising an event-related average altered response properties. Measures of response latency, peak time, magnitude, and prevalence were obtained for all ISI and average conditions. While quantitative measures were similar across ISI and averaging conditions, we observed more instances of "non-responses" with averages of ten trials as well as at an ISI of 0.5 s. These findings suggest an ISI of 1.0 s and an average consisting of at least 15 trials produce optimal results. Future studies using these stimulus parameters may produce more reliable data due to the fivefold decrease in subject participation time and a concomitant decrease in fatigue, boredom, and inattention.

Algorithms↗

Outer hair cell piezoelectricity: frequency response enhancement and resonance behavior.

Stretching or compressing an outer hair cell alters its membrane potential and, conversely, changing the electrical potential alters its length. This bi-directional energy conversion takes place in the cell's lateral wall and resembles the direct and converse piezoelectric effects both qualitatively and quantitatively. A piezoelectric model of the lateral wall has been developed that is based on the electrical and material parameters of the lateral wall. An equivalent circuit for the outer hair cell that includes piezoelectricity shows a greater admittance at high frequencies than one containing only membrane resistance and capacitance. The model also predicts resonance at ultrasonic frequencies that is inversely proportional to cell length. These features suggest all mammals use outer hair cell piezoelectricity to support the high-frequency receptor potentials that drive electromotility. It is also possible that members of some mammalian orders use outer hair cell piezoelectric resonance in detecting species-specific vocalizations.

Animals↗