PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Repeatability and Reproducibility”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

Topographical reproducibility of small scotoma using computerised dynamic fixation target.

The computer assisted dynamic fixation technique uses the patient's eye movements to locate the test stimulus in the central visual field in relation to a randomly meandering fixation target. The patient looks at the moving fixation target on a high resolution monitor and tries to keep it inside a circle using a joystick. The stimuli are presented at predetermined locations in a seemingly random manner and the awareness of the stimuli is registered by the patient pressing the joystick button. That novel fixation maintenance technique has been combined with suprathreshold static light offset (dark-on-bright-light decrement) stimuli created on a cathode ray tube and used in mapping of the physiological blind spot in 10 healthy eyes. Each eye was examined twice with the same test program in order to document the repeatability of the results. On two consective tests, the physiological blind spot measured an average of 5.7 degrees horizontally and 6.4 degrees vertically, using 15% (17 dB) contrast, 16 mm2, single intensity offset stimuli. The moving eye method and the light offset stimuli, on repeated testing, yielded an average topographical reproducibility rate of 73% in mapping of the scotomas, with an average of 1.4 degrees and 0.6 degree variability in the vertical and horizontal dimensions of the blind spot respectively.

Adult↗

Assessment of microsatellite instability in urine in the detection of transitional-cell carcinoma of the bladder.

Loss of heterozygosity (LOH) and alterations in microsatellite DNA markers have been reported in bladder-cancer tumors. We have studied, in a blinded fashion, using PCR-based microsatellite analysis, genetic alterations of cells exfoliated in urine of 59 Caucasian patients and control patients; 31 with initially confirmed bladder transitional-cell carcinoma (TCC), 17 with signs and symptoms suggestive of bladder cancer, 6 control patients who underwent renal transplantation, and 5 control patients with urolithiasis. Microsatellite analysis of cells exfoliated in the urine allowed the diagnosis of 83% (10/12) of patients with bladder TCC recurrence confirmed by cystoscopy, while 100% of patients followed up for transitional-cell carcinoma of the bladder for up to 12 months without evidence of tumor recurrence upon routine cystoscopy showed no microsatellite alterations. None of the patients without neoplasia (negative controls) had any microsatellite alterations, whereas all patients who underwent renal transplantation had additional new alleles corresponding to contamination with donor's renal and urothelial cells (positive controls). No control patients had any evidence of transitional-cell carcinoma by cystoscopy. Our results provide objective evidence that non-invasive molecular detection of bladder TCC by microsatellite analysis is reproducible with a sensitivity of 83% and a specificity of 100% in Caucasian patients. This non-invasive procedure represents a potential clinical tool for the detection and the screening of bladder TCC.

Adult↗

[In vivo dosimetry and radiographic confirmation in radiotherapy of Hodgkin's lymphoma].

In September 1991 a protocol for quality control of large shaped irradiation fields was started in our department. In vivo dosimetry with semiconductor detectors was used to measure the absorbed dose and patient positioning was checked with portal films weekly. First, we set a computed dosimetric system yielding dosimetric values in real time and allowing their easy storage. Then, we calibrated the diodes and determined the correction factors for each of them outside standard conditions. Entrance dose, exit dose and midline dose were measured in 62 patients undergoing supradiaphragmatic radiation therapy for Hodgkin's lymphoma. The exist dose was measured weekly to assess treatment repeatability. High agreement was observed between measured and calculated doses; repeatability was also high, since only 6% of exit dose measurements exceeded 5% of the first determination. In 33 patients portal films were obtained in the first treatment session, and thereafter weekly, to assess mispositioning relative to simulation (reproducibility) and from one session to another (repeatability). A small systematic error was detected in both longitudinal (x = -3 mm; SD = 3.7 mm) and transverse (x = -2 mm; SD = 3.4 mm) directions. Statistically significant errors (> 6 mm) were observed in 14% of patients. Reproducibility was excellent. The protocol reported on in this paper not only helps avoid systematic dosimetric and/or positioning errors in the patients, but also helps identify the main causes of uncertainty and thus remove them.

Hodgkin Disease↗

Reproducibility of LC-MS-based protein identification.

Traditional analysis of liquid chromatography-mass spectrometry (LC-MS) data, typically performed by reviewing chromatograms and the corresponding mass spectra, is both time-consuming and difficult. Detailed data analysis is therefore often omitted in proteomics applications. When analysing multiple proteomics samples, it is usually only the final list of identified proteins that is reviewed. This may lead to unnecessarily complex or even contradictory results because the content of the list of identified proteins depends heavily on the conditions for triggering the collection of tandem mass spectra. Small changes in the signal intensity of a peptide in different LC-MS experiments can lead to the collection of a tandem mass spectrum in one experiment but not in another. Also, the quality of the tandem mass spectrometry experiments can vary, leading to successful identification in some cases but not in others. Using a novel image analysis approach, it is possible to achieve repeat analysis with a very high reproducibility by matching peptides across different LC-MS experiments using the retention time and parent mass over charge (m/z). It is also easy to confirm the final result visually. This approach has been investigated by using tryptic digests of integral membrane proteins from organelle-enriched fractions from Arabidopsis thaliana and it has been demonstrated that very highly reproducible, consistent, and reliable LC-MS data interpretation can be made.

Arabidopsis↗

Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy.

PURPOSE: To measure the intrabreath-hold liver motion and the intrafraction and interfraction reproducibility of liver position relative to vertebral bodies using an active breathing coordinator (ABC) in patients with unresectable liver cancer treated with hypofractionated stereotactic body radiation therapy (SBRT). METHODS: Tolerability of ABC and organ motion during ABC was assessed using kV fluoroscopy in 34 patients. For patients treated with ABC, repeat breath-hold CT scans in the ABC breath-hold position were acquired at simulation to estimate the volumetric intrafraction reproducibility of the liver relative to the vertebral bodies. In addition, preceding each radiation therapy fraction, with the liver immobilized using ABC, repeat anteroposterior (AP) megavoltage verification images were obtained. Off-line alignments were completed to determine intrafraction reproducibility (from repeat images obtained before one treatment) and interfraction reproducibility (from comparisons of the final image for each fraction with the AP) of diaphragm position relative to vertebral bodies. For each image set, the vertebral bodies were aligned, and the resultant craniocaudal (CC) offset in diaphragm position was measured. Liver position during ABC was also evaluated from kV fluoroscopy acquired at the time of simulation, kV fluoroscopy at the time of treatment, and from MV beam's-eye view movie loops acquired during treatment. RESULTS: Twenty-one of 34 patients were screened to be suitable for ABC. The average free breathing range of these patients was 13 mm (range, 5-1 mm). Fluoroscopy revealed that the average maximal diaphragm motion during ABC breath-hold was 1.4 mm (range, 0-3.4 mm). The MV treatment movie loops confirmed diaphragm stability during treatment. For a measure of intrafraction reproducibility, an analysis of 36 repeat ABC computed tomography (CT) scans in 14 patients was conducted. The average mean difference in the liver surface position was -0.9 mm, -0.5 mm, and 0.2 mm in the CC, AP, and medial-lateral (ML) directions, with a standard deviation of 1.5 mm, 1.5 mm, and 1.5 mm, respectively. Ninety-five percent of the liver surface had an absolute differences in position between repeat ABC CT scans of less than 4.1 mm, 3.3 mm, and 3.3 mm in the CC, AP, and ML directions, respectively. Analysis of 257 MV AP images from patients treated using ABC revealed an average intrafraction CC reproducibility (sigma) of diaphragm relative to vertebral bodies of 1.5 mm (range, 0.6-3.9 mm). The average interfraction CC reproducibility (sigma) was 3.4 mm (range, 1.5-7.9 mm), indicating less day-to-day reproducibility of diaphragm position relative to vertebral bodies. The average absolute intra and interfraction CC offset in diaphragm position relative to vertebral bodies was 1.7 and 3.7 mm, respectively, with 86% of intrafraction and 54% of interfraction absolute offsets 3.0 mm or less. CONCLUSIONS: Intrafraction reproducibility of liver position using ABC is good in the majority of screened patients. However, interfraction reproducibility is worse, suggesting a need for image guidance.

Adult↗

Reproducibility of the head-up tilt test results in children with vasovagal syncope.

BACKGROUND: This prospective study aims to investigate the reproducibility of HUTT results in children with typical history of vasovagal syncope. METHODS: Between October 1996 and October 1999, 58 children with a history of typical vasovagal syncope attacks were evaluated with head up tilt test (HUTT). The table was tilted to 60 degrees and the patients were monitored for heart rate and blood pressure changes during 45 min. No provocative agents were used. The test was repeated a week later at a similar setting. RESULTS: Of 58 patients, 39 had positive and 19 had negative response during the initial test. During the second test, the positive response was reproduced in 29 cases (50%), and the negative response was reproduced in 16 cases (28%). Ten patients (17%) with an initial positive test had a negative second test. A negative test became positive only in three patients (5%). There were 12 vasodepressor, four cardioinhibitor and 23 mixed responses among the initial tests. Only in four patients did the type of the response change from vasodepressor to a mixed type during the second test. The reproducibility of a positive tilt test was 74.4% (29/39), the negative tilt test was 84.2% (16/19), and the overall reproducibility of the HUTT was 77.6% (45/58). CONCLUSIONS: Unprovoked HUTT in children is reproducible when repeated on different days and similar settings and the results are comparable to the ones with adult patients.

Adolescent↗

Programmed electrical stimulation in Brugada syndrome: how reproducible are the results?

INTRODUCTION: Inducibility of ventricular arrhythmias at programmed electrical stimulation (PES) ranges between 50% and 80% of patients with Brugada syndrome. However, the variety of PES protocols and the lack of data relative to a control group or to ventricular arrhythmia reproducibility contribute to a still undefined interpretation of PES outcome in Brugada syndrome. METHODS AND RESULTS: Twenty-one patients with Brugada syndrome (18 men and 3 women; mean age 34 years; 9/21 symptomatic; 8/21 with SCN5A gene mutation) underwent a PES protocol from two right ventricular sites. The endpoint was PES protocol completion or induction of sustained or reproducible (>6 consecutive inductions) nonsustained (>6 beats) fast ventricular arrhythmia. In 17 of 21 patients with Brugada syndrome, PES was repeated 2 months later to test ventricular arrhythmia reproducibility. Twenty-five healthy patients (17 men; mean age 36 years) formed the control group. In patients with Brugada syndrome, ventricular arrhythmia inducibility rate at PES was high (18/21 patients [85%]) and increased with protocol aggressiveness, independent of clinical presentation. In control subjects, no ventricular arrhythmias were induced. Among patients with Brugada syndrome, 14 (82%) of 17 patients remained inducible at a second PES. CONCLUSION: In our experience, ventricular arrhythmia inducibility in patients with Brugada syndrome, at variance with healthy controls, is high and does not correlate with clinical presentation. PES inducibility is deeply influenced by the protocol used. PES outcome is reproducible at a mid-term follow-up mainly if a categorical endpoint (inducible vs noninducible) is used. The need to assess the predictive value of specific PES protocols in targeted studies is widely emerging and is confirmed by our results.

Adult↗

Within-subject reproducibility of near-infrared spectroscopy signals in sensorimotor activation after 6 months.

Near-infrared spectroscopy (NIRS) can measure the product of the optical path length and the concentration change in oxygenated hemoglobin (DeltaC'oxy), deoxygenated hemoglobin (DeltaC'deoxy), and their sum (DeltaC'total) in the human cerebral cortex, and it has been used for noninvasive investigation of human brain functions. We evaluate the within-subject reproducibility of the NIRS signals by repeated measurement of the sensorimotor cortex in healthy adults taken over a period of about 6 months using near-infrared (NIR) topography. The maximum signal amplitudes and the location of activation centers are compared between two sessions for each subject. The signal amplitudes vary between sessions and no consistent tendency in the changes is found among subjects. However, the distance between the activation centers identified in two sessions is relatively small, within 20 mm on average across subjects, which is comparable to the smallest distance between measurement positions in the NIR topography (21 mm). Moreover, within-subject comparisons of signal time courses show high correlation coefficients (>0.8) between the two sessions. This result, demonstrating a high within-subject reproducibility of the temporal information in NIRS signals, particularly contributes to the development of a new application of NIRS.

Adult↗

Effect of digital filtering on the measurement of the depth of proximal caries under different exposure conditions.

PURPOSE: To compare different image processing modes (filters) on the reproducibility and accuracy of the assessment of proximal carious lesions viewed in direct digital radiographs. Variables studied were exposure time and tissue scatter radiation. METHODS: Standardized direct digital radiographs of 50 extracted teeth were obtained and 44 areas of proximal caries were detected histologically. Four radiographs were obtained of each tooth using a charge coupled device sensor. Two radiographs were obtained with and two without tissue scatter radiation equivalent (TSRE) each of them at normal exposure time (0.06 second) and underexposed (0.01 second). On each of the 200 radiographs, the central depth (CD) of each carious lesion was measured at 21-fold magnification both on the unchanged image and after use of two different filters (median, median plus inversion). All measurements were repeated after 1 week to estimate reproducibility. Histometric CD assessments provided a gold standard for comparison with the radiographic measurements (accuracy). RESULTS: Whereas reproducibility was not influenced significantly by any of the investigated parameters, defect type and exposure time influenced the overall accuracy of CD measurements. Basic digital filtering of radiographic images failed to result in statistically significant improvement of the accuracy of CD measurements.

Dental Caries↗

Iterative reconstruction based on median root prior in quantification of myocardial blood flow and oxygen metabolism.

UNLABELLED: The aim of this study was to compare reproducibility and accuracy of two reconstruction methods in quantification of myocardial blood flow and oxygen metabolism with 15O-labeled tracers and PET. A new iterative Bayesian reconstruction method based on median root prior (MRP) was compared with filtered backprojection (FBP) reconstruction method, which is traditionally used for image reconstruction in PET studies. METHODS: Regional myocardial blood flow (rMBF), oxygen extraction fraction (rOEF) and myocardial metabolic rate of oxygen consumption (rMMRO2) were quantified from images reconstructed in 27 subjects using both MRP and FBP methods. For each subject, regions of interest (ROIs) were drawn on the lateral, anterior and septal regions on four planes. To test reproducibility, the ROI drawing procedure was repeated. By using two sets of ROIs, variability was evaluated from images reconstructed with the MRP and the FBP methods. RESULTS: Correlation coefficients of mean values of rMBF, rOEF and rMMRO2 were significantly higher in the images reconstructed with the MRP reconstruction method compared with the images reconstructed with the FBP method (rMBF: MRP r = 0.896 versus FBP r = 0.737, P < 0.001; rOEF: 0.915 versus 0.855, P < 0.001; rMMRO2: 0.954 versus 0.885, P < 0.001). Coefficient of variation for each parameter was significantly lower in MRP images than in FBP images (rMBF: MRP 23.5% +/- 11.3% versus FBP 30.1% +/- 14.7%, P < 0.001; rOEF: 21.0% +/- 11.1% versus 32.1% +/- 19.8%, P < 0.001; rMMRO2: 23.1% +/- 13.2% versus 30.3% +/- 19.1%, P < 0.001). CONCLUSION: The MRP reconstruction method provides higher reproducibility and lower variability in the quantitative myocardial parameters when compared with the FBP method. This study shows that the new MRP reconstruction method improves accuracy and stability of clinical quantification of myocardial blood flow and oxygen metabolism with 15O and PET.

Adult↗

Limited performance of quantitative assessment of myocardial function by thallium-201 gated myocardial single-photon emission tomography.

We investigated the reproducibility between thallium-201 and technetium-99m methoxyisobutylisonitrile (MIBI) gated single-photon emission tomography (SPET) for the assessment of indices of myocardial function such as end-diastolic and end-systolic volume (EDV, ESV), ejection fraction (EF) and wall motion. Rest 201Tl (111 MBq) gated SPET was sequentially performed twice in 20 patients. Rest 201Tl gated SPET and rest 99mTc-MIBI (370 MBq) gated SPET were performed 24 h apart in 40 patients. Wall motion was graded using the surface display of the Cedars quantitative gated SPET (QGS) software. EDV, ESV and EF were also measured using the QGS software. The reproducibility of functional assessment on rest 201Tl gated SPET was compared with that on 99mTc-MIBI gated SPET, and also with that between 201Tl gated SPET and 99mTc-MIBI gated SPET performed on the next day. The two standard deviation (2 SD) values for EDV, ESV and EF on the Bland-Altman plot were 29 ml, 19 ml and 12%, respectively, on repeated 201Tl gated SPET, compared with 14 ml, 11 ml and 5.3% on repeated 99mTc-MIBI gated SPET. The correlations were good (r=0.96, 0.97 and 0.87) between the two measurements of EDV, ESV and EF on repeated rest studies with 201Tl and 99mTc-MIBI gated SPET. However, Bland-Altman analysis revealed that the 2 SD values between the two measurements were 31 ml, 23 ml and 12%. We were able to score the wall motion in all cases using the 3D surface display of the QGS on 201Tl gated SPET. The kappa value of the wall motion grade on the repeated 201Tl study was 0.35, while that of the wall motion grade on the repeated 99mTc-MIBI study was 0.76. The kappa value was 0.49 for grading of wall motion on repeated rest studies with 201Tl and 99mTc-MIBI. In conclusion, QGS helped determine EDV, ESV, EF and wall motion on 201Tl gated SPET. Because the EDV, ESV and EF were less reproducible on repeated 201Tl gated SPET or on 201Tl gated SPET and 99mTc-MIBI gated SPET on the next day than on repeated 99mTc-MIBI gated SPET, functional measurement on 201Tl gated SPET did not seem to be interchangeable with that on 99mTc-MIBI gated SPET.

Coronary Disease↗

Evaluation of an optical instrument for objective assessment of oral mucosal erythema.

This study evaluated the sensitivity and reproducibility of an optical instrument, the Erythema Meter, for quantifying erythema of palatal mucosa. The instrument is based on the principle that haemoglobin in the vasculature selectively absorbs green light but has little effect on red light and allows derivation of an 'erythema index'. Non-clinical investigations were carried out by taking a series of Erythema Meter readings from each colour block on a red check-standard used by graphic artists for colour reproduction. For clinical assessment, 20 dentate patients with healthy palatal mucosa and 40 complete denture wearers (20 with denture stomatitis and 20 with healthy palatal mucosa) were enrolled, and palatal erythema determined both visually and using the Erythema Meter. Two weeks later the Erythema Meter readings for the 40 patients with healthy palatal mucosa were repeated, to allow assessment of the reproducibility of the Erythema Meter scores. The median erythema index was 12 (range 2-38) for dentate patients with healthy palatal mucosa and 5 (range 0-29) for denture wearers with healthy palatal mucosa. For denture stomatitis patients the median erythema index was 95 (range 36-117). The overall reproducibility coefficient was 88%. Visual scoring correlated poorly with the Erythema Meter scores for those with moderate degrees of erythema. The Erythema Meter provides an objective and reproducible means of measuring the degree of erythema of the palatal mucosa.

Adolescent↗

Characterization of Klason lignins by reversed-phase high-performance liquid chromatography using wide-pore octadecylsilica and stepwise gradients of dimethylformamide in water.

RP-HPLC using stepwise gradients of N,N-dimethylformamide (DMF) in a phosphate-buffered (pH 3.00) aqueous mobile phase and a wide-pore (30 nm) octadecylsilica column has been applied to the analysis of a variety of lignins--organocell lignin, dioxane lignin, Björkman lignin, and Klason lignins from both softwoods and hardwoods, respectively, in order to demonstrate the usefulness of the approach for their characterization. Tandem combination of spectrophotometric diode array detection and fluorimetric detection was used to acquire more detailed information about the chromatographic behavior of lignins. The results show that a ten-step gradient can reveal distinct features of lignins and humic substances. Combination of good solvating properties of DMF for lignins together with a wide-pore RP sorbent improves surface interactions of the analytes and suppresses the influence of size exclusion effects. Thus it provides reproducibility of characterization profiles and robustness of the method. The calculated repeatability of the retention time of selected peaks was +/- 0.46% RSD. The reproducibility of the data within one week (set of seven data) was +/- 1.1% RSD. These data are also representative of the other well-shaped peaks of analyzed substances.

Buffers↗

Intra- and inter-radiation therapist reproducibility of daily isocenter verification using prostatic fiducial markers.

BACKGROUND: We sought to determine the intra- and inter-radiation therapist reproducibility of a previously established matching technique for daily verification and correction of isocenter position relative to intraprostatic fiducial markers (FM). MATERIALS AND METHODS: With the patient in the treatment position, anterior-posterior and left lateral electronic images are acquired on an amorphous silicon flat panel electronic portal imaging device. After each portal image is acquired, the therapist manually translates and aligns the fiducial markers in the image to the marker contours on the digitally reconstructed radiograph. The distances between the planned and actual isocenter location is displayed. In order to determine the reproducibility of this technique, four therapists repeated and recorded this operation two separate times on 20 previously acquired portal image datasets from two patients. The data were analyzed to obtain the mean variability in the distances measured between and within observers. RESULTS: The mean and median intra-observer variability ranged from 0.4 to 0.7 mm and 0.3 to 0.6 mm respectively with a standard deviation of 0.4 to 1.0 mm. Inter-observer results were similar with a mean variability of 0.9 mm, a median of 0.6 mm, and a standard deviation of 0.7 mm. When using a 5 mm threshold, only 0.5% of treatments will undergo a table shift due to intra or inter-observer error, increasing to an error rate of 2.4% if this threshold were reduced to 3 mm. CONCLUSION: We have found high reproducibility with a previously established method for daily verification and correction of isocenter position relative to prostatic fiducial markers using electronic portal imaging.

Equipment Design↗

Quantitative determination of heme for forensic characterization of bacillus spores using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

A quantitative method was developed for the determination of heme (ferriprotoporphyrin IX) using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). The method was designed for forensic characterization of the use of blood agar in preparation of Bacillus spores. An alkali wash of 0.3 M ammonium hydroxide was used to solubilize heme from spore samples. The wash was concentrated and analyzed by MALDI-TOFMS. Experimental parameters were optimized to obtain the best signal intensity, maximize signal reproducibility, and improve day-to-day repeatability of the measurement. Sinapinic acid was found to be the best matrix. A sandwich sample preparation protocol was determined to increase the shot-to-shot and point-to-point reproducibility of the measurement. Cobalt(III) protoporphyrin was used as an internal standard and the analyte/internal standard ratio responses from solutions of known concentrations were used to construct a calibration curve (R(2) = 0.993). Limits of detection and quantitation for heme were calculated to be approximately 0.4 (200 fmol) and 0.8 microM (400 fmol), respectively. Spore samples prepared on blood agar and nonblood agar were analyzed using the method. Heme was detected at a concentration of approximately 0.3 ng/mg of spore on samples prepared on blood agar and purified by extensive washing. Heme was not detected on spore samples prepared without blood.

Agar↗

Semi-automated digital image analysis of patellofemoral joint space width from lateral knee radiographs.

OBJECTIVE: To design a semi-automated program to measure minimum patellofemoral joint space width (JSW) using standing lateral view radiographs. DESIGN: Lateral patellofemoral knee radiographs were obtained from 35 asymptomatic subjects. The radiographs were analyzed to report both the repeatability of the image analysis program and the reproducibility of JSW measurements within a 2 week period. The results were also compared with manual measurements done by an experienced musculoskeletal radiologist. RESULTS: The image analysis program was shown to have an excellent coefficient of repeatability of 0.18 and 0.23 mm for intra- and inter-observer measurements respectively. The manual method measured a greater minimum JSW than the automated method. Reproducibility between days was comparable to other published results, but was less satisfactory for both manual and semi-automated measurements. The image analysis program had an inter-day coefficient of repeatability of 1.24 mm, which was lower than 1.66 mm for the manual method. CONCLUSIONS: A repeatable semi-automated method for measurement of the patellofemoral JSW from radiographs has been developed. The method is more accurate than manual measurements. However, the between-day reproducibility is higher than the intra-day reproducibility. Further investigation of the protocol for obtaining sequential lateral knee radiographs is needed in order to reduce the between-day variability.

Adult↗

Bone mineral density in healthy normal women and reproducibility of measurements in spine and hip using dual-energy X-ray absorptiometry.

Bone mineral density (BMD) using dual-energy X-ray absorptiometry (DEXA) has been measured in 394 healthy normal women. BMD is highest at the end of the 3rd decade and declines from 45 to 75 years by 0.0095 g/cm2/year in the lumbar spine and by 0.0052-0.0078 g/cm2/year in the upper femur depending on the site. BMD appears to increase in the 8th decade. Reproducibility (coefficient of variation (CV) of repeated measurements) was lowest in the lumbar spine (1.45%) and highest in Ward's triangle (4.29%). CV was not influenced by age at any site and by osteoporosis only in the femoral neck. BMD increased from L2 to L4 but the increase could not wholly be accounted for by the size of the vertebra, suggesting that the posterior elements were contributing to the observed increase of bone density.

Absorptiometry, Photon↗

Diurnal changes in plasma lipoproteins of free-living healthy men consuming a standard diet.

Although it is well established that plasma lipoproteins are involved in atherogenesis, most patients with coronary heart disease have normal or nearly normal fasting plasma lipid and lipoprotein levels. As most of the human life is spent in the fed state we elected to investigate the changes occurring in plasma lipids and lipoproteins during normal daily activities. We studied 12 healthy, normolipidemic and non-obese subjects on a standard diet divided into three meals and three snacks. This method was found to be accurate and reproducible in four subjects who underwent repeated studies. The major diurnal changes were observed in plasma triglyceride level and in the composition of plasma lipoproteins. The degree and pattern of these changes differed among subjects but was specific and constant for each individual. The extent of these diurnal changes, which correlated positively with fasting plasma triglyceride and inversely with plasma HDL2 levels, may play an important role in the pathogenesis of atherosclerosis.

Activities of Daily Living↗