PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Regional differences in mechanical properties between major arteries--an experimental study in sheep.

PURPOSE: To study possible differences in mechanical properties between central (abdominal aorta) and more peripheral (common carotid and common femoral) arteries validating an earlier non-invasive study in children showing that central arteries are more distensible than peripheral ones. As invasive blood pressure was needed, but ethically impossible to obtain in children in an experimental setting, an animal model was chosen. DESIGN: Open experimental study. SETTING: Animal laboratory at university hospital. MATERIAL AND METHODS: The pulsatile vessel wall movements of the abdominal aorta (AA), common femoral (CFA) and common carotid (CCA) artery of nine sheep were examined using an ultrasound phase-locked echo-tracking technique. Intra-arterial blood pressure was measured and pressure-diameter relations, pressure strain elastic modulus (Ep) and stiffness (beta) calculated. Distensibility was defined as the inverse of Ep and stiffness. RESULTS: The AA showed lower values for Ep and stiffness (beta) than the CFA (p = 0.002) and CCA (p = 0.006), i.e. the latter two vessels were stiffer. The pressure-diameter relations confirmed these differences and showed a non-linearity for all three vessels with increased stiffness above 70-90 mm Hg. CONCLUSION: This study on young animals supports earlier findings of differences in mechanical properties between central and more peripheral arteries seen in healthy children. As pathologies between these vessels differ, with dilatation of the abdominal aorta and occlusive disease in the more peripheral vessels, part of the explanation might be found in the mechanical properties of the healthy vessels, characterised here with the echo-tracking technique.

Animals↗

An initial investigation of photocurable three-dimensional lactic acid based scaffolds in a critical-sized cranial defect.

Degradable polymer networks formed by the photoinitiated polymerization of multifunctional monomers have great potential as in situ forming materials, especially for bone tissue engineering. In this study, one specific chemistry was analyzed with respect to bone formation in a critical-sized defect model with and without adsorbed osteoinductive growth factors present. The scaffolds degraded in approximately 8 months and possessed an elastic modulus similar to that of trabecular bone. A porous scaffold fabricated with approximately 80% porosity and pore diameters ranging from 45 to 150 mm was implanted in a critical-sized cranial defect in rats. When implanted alone, the scaffolds were filled primarily with fibrous tissue after 9 weeks with only mild inflammation at the defect site. When the scaffolds released osteoinductive growth factors, statistically more bone filled the scaffold. For instance, 65.8+/-9.4% (n=5) of the defects were filled with radiopaque tissue in the osteoinductive releasing scaffolds, whereas only 24.2+/-7.4% (n=5) of the defects were filled in the untreated defects 9 weeks after implantation. These results illustrate not only the benefits of delivering osteoinductive factors when developing synthetic bone grafts, but the potential of these materials for supporting the infiltration and development of bone in large defects.

Animals↗

Atomic force and total internal reflection fluorescence microscopy for the study of force transmission in endothelial cells.

This paper describes the combined use of atomic force microscopy (AFM) and total internal reflection fluorescence microscopy (TIRFM) to examine the transmission of force from the apical cell membrane to the basal cell membrane. A Bioscope AFM was mounted on an inverted microscope, the stage of which was configured for TIRFM imaging of fluorescently labeled human umbilical vein endothelial cells (HUVECs). Variable-angle TIRFM experiments were conducted to calibrate the coupling angle with the depth of penetration of the evanescent wave. A measure of cellular mechanical properties was obtained by collecting a set of force curves over the entire apical cell surface. A linear regression fit of the force-indentation curves to an elastic model yields an elastic modulus of 7.22 +/- 0. 46 kPa over the nucleus, 2.97 +/- 0.79 kPa over the cell body in proximity to the nucleus, and 1.27 +/- 0.36 kPa on the cell body near the edge. Stress transmission was investigated by imaging the response of the basal surface to localized force application over the apical surface. The focal contacts changed in position and contact area when forces of 0.3-0.5 nN were applied. There was a significant increase in focal contact area when the force was removed (p < 0.01) from the nucleus as compared to the contact area before force application. There was no significant change in focal contact coverage area before and after force application over the edge. The results suggest that cells transfer localized stress from the apical to the basal surface globally, resulting in rearrangement of contacts on the basal surface.

Biophysical Phenomena↗

Axial nonuniformity of geometric and mechanical properties of mouse aorta is increased during postnatal growth.

The hemodynamic conditions of aorta are relatively uniform prenatally and become more heterogeneous postnatally. Our objective was to quantify the heterogeneity of geometry and mechanical properties during growth and development. To accomplish this objective, we obtained a systematic set of data on the geometry and mechanical properties along the length of mouse aorta during postnatal development. C57BL/6 mice of ages 1-33 days were studied. The ascending aorta was cannulated in situ and preconditioned with several cyclic changes in pressure. We investigated the axial variations of geometry (diameter and length) and mechanical properties (stress-stain relation, elastic modulus and compliance) of the mouse aorta from the aortic valve to the common iliac. Our results show that the arterial blood pressure of mice increased from approximately 30 to 80 mmHg during the first 2 wk of life. The stretch ratio, diameter, wall (intima-media) thickness, and total lumen volume of mouse aorta increased with age. The aorta was transformed from a cylindrical tube at birth to a tapered structure during growth. Furthermore, we found the mechanical properties were fairly uniform along the length of the aorta at birth and become more nonuniform with age. We conclude that the rapid change of blood pressure and blood flow after birth alter the geometric and mechanical properties differentially along the length of the aorta. Hence, the axial nonuniformity of the aorta increases as the organ becomes more specialized during growth and development.

Aging↗

[The influence of the change in postburn erythrocyte membrane viscoelasticity on the regional myocardial blood flow].

OBJECTIVE: To explore the characteristics of the dynamic change in postburn erythrocyte membrane viscoelasticity and its influence on the regional myocardial blood flow. METHODS: Wistar rats inflicted with 30% TBSA III degree scalding on the back were employed as the model. The mechanical indices of erythrocytic membrane, such as elastic modulus and the coefficient of viscosity, were determined with micro-pipe sucking methods at preburn and 1, 3, 6, 12, 24 and 48 postburn hours (PBHs). The regional myocardial blood flow was simultaneously monitored with hydrogen clearance methods. RESULTS: The erythrocyte membrane viscoelasticity increased sharply at 3 PBH, reached the peak level at 6 PBH and decreased gradually thereafter to near normal level at 24 PBH. The regional myocardial blood flow decreased obviously at 1 PBH, it reached the lowest level at 6 PBH and bounced back to near normal level at 48 PBHs. The change in the viscoelasticity was significantly and negatively correlated to that of the regional myocardial blood flow. CONCLUSION: The deformability of postburn erythrocyte membrane decreased, leading to the decrease in the regional myocardial blood flow. This might be one of the important reasons of postburn myocardial injury.

Animals↗

Finite element analysis of thermo-debonding mechanism in dental composites.

Finite element method (FEM) has been extensively used for evaluating interfacial status inside biomaterials. This study using FEM was designed to evaluate the thermal stress behavior of a filler-matrix interface. The results were then compared to those of a previous study obtained by a laser thermoacoustic technique (LTAT). The experimental systems (75/25 Bis-GMA/TEGDMA resin reinforced with 0, 25, 50, and 75 wt% 8-microm silanized/unsilanized BaSiO6) as used in the previous study were modeled in this study. The established finite element models were based on coefficient of thermal expansion (CTE) Mismatch Phenomenon. The mechanical properties of the silane coupling agent, such as elastic modulus and thermal expansion coefficient used in the silanized model, were assumed to have optimal heat flux transfer. A third (imaginary) material was proposed to block the transfer of thermal stress between the filler and matrix in the unsilanized model. The thermal load simulation was based on steady-state thermal analysis. The results showed that: (1) The strain energy and interfacial shearing stress calculated from FEM validate the results from the previous LTAT study. (2) Comparing the stress distribution of silanized and unsilanized FEM models, the acoustic signals in LTAT study are mainly derived from debonding of the filler-matrix interface of silanized specimens, and from the matrix area of unsilanized specimens. Based on results to date, we conclude that the finite element method may be a powerful tool for exploring thermoacoustic mechanisms of dental composites.

Acoustics↗

Optimization of the bearing surface geometry of total knees.

Various design criteria were examined in combination to find the ideal geometry for a condylar knee replacement. The criteria were the contact stresses on the plastic, femoral-tibial size interchangeability, patella lever arm, laxity and stability and the amount of bone resection required. The variables were the radii of curvature of the femoral and tibial bearing surfaces in the sagittal and frontal planes. Metal toroidal indentors were loaded onto dished surfaces of UHMWPE covering a range of radii and the contact areas measured. Using elasticity equations, the apparent elastic modulus of UHMWPE ranged from 400 to 600 MPa for less conforming to closely conforming surfaces. Using a value of 600 MPa, contact stresses were predicted for a complete spectrum of radii of curvature. Finite element analysis was used to determine the stresses beneath the contact patches when different femoral-tibial sizes were interchanged. A computergraphics program was written to analyse the effects of flexion, rotation and femoral roll-back on the contact point locations. An influential variable was the sagittal curvature of the femoral component, notably the point of transition between the posterior curve of small radius and the distal curve of larger radius. This affected the patella lever arm, the stability, and the bone resection. Interchangeability was primarily dependent upon the relative frontal radii. Contact stresses and contact locations depended upon the combination of sagittal and frontal radii. The most suitable geometrical combinations overall were discussed.

Biomechanical Phenomena↗

Templated biomineralization on self-assembled protein fibers.

Biological mineralization of tissues in living organisms relies on proteins that preferentially nucleate minerals and control their growth. This process is often referred to as "templating," but this term has become generic, denoting various proposed mineral-organic interactions including both chemical and structural affinities. Here, we present an approach using self-assembled networks of elastin and fibronectin fibers, similar to the extracellular matrix. When induced onto negatively charged sulfonated polystyrene surfaces, these proteins form fiber networks of approximately 10-mum spacing, leaving open regions of disorganized protein between them. We introduce an atomic force microscopy-based technique to measure the elastic modulus of both structured and disorganized protein before and during calcium carbonate mineralization. Mineral-induced thickening and stiffening of the protein fibers during early stages of mineralization is clearly demonstrated, well before discrete mineral crystals are large enough to image by atomic force microscopy. Calcium carbonate stiffens the protein fibers selectively without affecting the regions between them, emphasizing interactions between the mineral and the organized protein fibers. Late-stage observations by optical microscopy and secondary ion mass spectroscopy reveal that Ca is concentrated along the protein fibers and that crystals form preferentially on the fiber crossings. We demonstrate that organized versus unstructured proteins can be assembled mere nanometers apart and probed in identical environments, where mineralization is proved to require the structural organization imposed by fibrillogenesis of the extracellular matrix.

Animals↗

Evaluation of the early stage of carotid atherosclerosis using the vascular response to nitroglycerin and high-resolution ultrasonography.

The purpose of this study was to determine whether the early stages of arterial atherosclerosis could be evaluated by the vascular response to nitroglycerin (NTG). The vascular elasticity of the common carotid artery (CCA) was evaluated at sites without atheromatous plaque using high-resolution ultrasonography before and after sublingular NTG administration. The vascular elasticity was expressed by vascular strain (VS) and pressure-strain elastic modulus (Ep). The study was performed in 9 normal young males (group N) and 52 patients who were suspected to have coronary artery disease (CAD). In group N, VS of the CCA increased from 9+/-2 to 13+/-4%, Ep decreased from 80+/-18 to 42+/-14 kPa (p<0.01) and systolic blood pressure (SBP) decreased from 116+/-8 to 109+/-8 mmHg (p<0.05) after NTG administration. Two different responses were observed in the patients. One group of patients (group A, n=27) showed similar responses to NTG as those of group N; that is, VS increased from 8+/-4 to 14+/-8%, Ep decreased from 115+/-64 to 57+/-31 kPa (p<0.01) and SBP decreased from 121+/-15 to 110+/-16 mmHg (p<0.05). In the other group (group B, n=25), in spite of SBP decreasing from 124+/-21 to 111+/-21 mmHg (p<0.05), VS decreased from 11+/-4 to 7+/-3% and Ep increased from 76+/-29 to 113+/-53 kPa (p<0.01). The prevalence and severity of CAD were lower in group A than in group B (33 vs 80%, 11 vs 60%, p<0.01, respectively). The prevalence of atheromatous plaque of the CCA was also lower in group A than in group B (4 vs 22%, p<0.01). These results revealed that the prevalence of carotid atheromatous plaque was highly correlated with that of CAD (p=0.001) and suggested that the vascular elasticity response of the CCA to NTG is highly associated with atherosclerotic changes of the artery and may be a useful method for detecting the early stages of atherosclerosis.

Administration, Sublingual↗

Relation of arterial structure and function to left ventricular geometric patterns in hypertensive adults.

OBJECTIVES: The present study sought to determine whether conduit artery structure and function vary according to the pattern of left ventricular adaptation to hypertension. BACKGROUND: Although left ventricular geometric pattern has been shown to predict cardiovascular events in hypertension, the arterial status in patients with the different patterns is unknown. METHODS: We evaluated arterial structure and function by carotid ultrasound and applanation tonometry in 271 unmedicated hypertensive patients classified by echocardiography as having normal ventricular geometry (n = 176), concentric remodeling (n = 54), concentric hypertrophy (n = 16) or eccentric hypertrophy (n = 25). RESULTS: All groups were similar in age, gender distribution and body size. Patients with concentric and eccentric hypertrophy had similar blood pressures (mean 173/100 and 171/99 mm Hg, respectively) and left ventricular mass, but compared with patients with normal left ventricular geometry and concentric remodeling, only those with concentric hypertrophy had increased arterial wall thickness (0.96 +/- 0.20 vs. 0.80 +/- 0.18 mm, p < 0.05), end-diastolic diameter (6.38 +/- 0.97 vs. 5.76 +/- 0.87 mm, p < 0.05), cross-sectional area (22.1 +/- 5.71 vs. 16.6 +/- 5.4 mm(1)2 p < 0.05) and elastic modulus (713 +/- 265 vs. 471 +/- 241 dynes/cm2 x 10(-5), p < 0.05). Patients with concentric remodeling and eccentric hypertrophy had similar values for these measures (0.85 +/- 0.22 and 0.89 +/- 0.21 mm, 5.67 +/- 0.77 and 6.04 +/- 0.44 mm, 17.2 +/- 5.4 and 19.7 +/- 5.9 mm2, 558 +/- 263 and 614 +/- 257 dynes/cm2 x 10(-6), respectively), despite lower systolic blood pressures in the former group (156/94 mm Hg, p < 0.001). The prevalence of plaque was comparable in patients with concentric (56%) and eccentric (42%) hypertrophy and significantly greater than that in patients [corrected] with normal geometry (21%). CONCLUSIONS: Among patients with generally mild, uncomplicated systemic hypertension, arterial structure and function are most abnormal when concentric left ventricular hypertrophy is present and may contribute to the more adverse outcome associated with this geometric pattern.

Adaptation, Physiological↗

Improved common carotid elasticity and intima-media thickness measurements from computer analysis of sequential ultrasound frames.

B-mode ultrasound has gained popularity as a non-invasive method for direct visualization of superficial vessels. With B-mode ultrasound, arterial stiffness can be directly measured since image acquisition of the arterial wall thickness and vessel diameter can be obtained simultaneously in a dynamic fashion throughout the cardiac cycle. Recently, a method was developed to measure carotid arterial diameter and intima-media thickness (IMT) from B-mode images that utilizes computerized edge tracking-multiframe image processing that automatically measures arterial diameter and IMT in multiple sequential frames spanning several cardiac cycles. To evaluate this method, replicate B-mode common carotid artery ultrasound examinations and blood pressure measurements were obtained in 24 subjects 1-2 weeks apart. Approximately 80 sequential frames spanning two cardiac cycles were analyzed from each ultrasound examination to obtain maximum arterial diameter (D(max)), minimum arterial diameter (D(min)), and IMT using a computerized edge detection method. The intraclass correlations of D(max), D(min), and IMT were 0.97-0.99 and the mean absolute difference for these measurements were 0.03-0.11 mm. The coefficient of variation for D(max) and D(min) were 1.28 and 1.18%, respectively. The intraclass correlation for several standard arterial stiffness indices, Peterson's elastic modulus, Young's modulus, arterial distensibility, compliance, and the beta stiffness index ranged between 0.84 and 0.89. Additionally, it was determined that averaging IMT over five frames centered at D(min) reduced single frame IMT measurement variability by 27% (P=0.005) compared with IMT measured from a single frame corresponding to D(min). Comparison of the phasic relationship of D(max) and D(min) measured from the B-mode ultrasound image with the simultaneously recorded electrocardiogram (ECG) signal in the 24 subjects, provided a more accurate method of frame selection for arterial diameter extrema independent of the ECG signal. The method of computerized edge detection-sequential multiframe image processing presented in this paper represents a technological advance for image analysis of B-mode ultrasound images of common carotid arterial dimensions that is highly reproducible and directly applicable to noninvasive imaging of atherosclerosis.

Aged↗

Measurement of local viscoelasticity and forces in living cells by magnetic tweezers.

We measured the viscoelastic properties of the cytoplasm of J774 macrophages with a recently developed microrheometer. Ferromagnetic beads (1.3 microm in diameter) were used to determine the local viscoelastic moduli. Step-force pulses were applied to the magnetic beads and the displacement was observed by single particle tracking. By analyzing the creep response curves in terms of a triphasic mechanical equivalent circuit, we measured the shear elastic modulus, the effective viscosities, and the strain relaxation time. The values of the shear modulus vary by more than an order of magnitude within the cell population (range, 20-735 Pa; average, 343 Pa) and by a factor of 2 within single cells. The effective viscosity of the cytoplasm exhibits a relatively sharp distribution about an average of eta = 210 Pa s (+/- 143 Pa s). We measured the displacement field generated by the local forces by observing the induced motion of nonmagnetic beads. Even at distances of the order of 1 microm, no induced motion was seen, suggesting that the cytoplasm is composed of clusters of densely packed and cross-linked filaments separated by soft regions. In another series of experiments we analyzed the magnetophoretic motion of the ferromagnetic beads at a constant magnetic force. Measuring the bead velocity parallel and perpendicular to the applied force showed that local active forces on the beads varied from 50 to 900 pN.

Animals↗

Characterization of polydimethacrylates and their composites by dynamic mechanical analysis.

The objective was to characterize, by dynamic mechanical analysis (DMA), the polymeric materials used to restore teeth and, in particular, to assign a glass transition temperature, Tg. Generally, in DMA work, Tg is taken as the temperature at which the internal damping, i.e., tan delta, has a maximum value. However, in the present work it was shown that the classical method of assigning Tg corresponds more closely to an assignment based on changes in elastic modulus. On this basis, a bis-GMA copolymer and a proprietary dental composite, both polymerized by exposure to light, were assigned Tg values of -25 degrees C and +10 degrees C, respectively. The composite had an even lower value, Tg = -10 degrees C, after saturation with water. The value of Tg can be increased considerably by treatments which are known to increase the degree of polymerization, i.e., by heating or by gamma-irradiation. The present findings imply that composites made by photopolymerization may undergo marked changes in mechanical state (becoming glassy, leathery, and rubbery) in the oral cavity, due to changes in temperature from about 0 degree C to 50 degrees C. It is not known which of these states would give best service properties, such as wear resistance, but in any case variation of properties in service would appear to be undesirable.

Bisphenol A-Glycidyl Methacrylate↗

Single-crystalline ceramic whisker-reinforced carboxylic acid-resin composites with fluoride release.

Currently available glass-ionomer, resin-modified glass-ionomer, and compomer materials have relatively low strength and toughness and, therefore, are inadequate for use in large stress-bearing posterior restorations. In the present study, ceramic single-crystalline whiskers were mixed with fluorosilicate glass particles and used as fillers to reinforce experimental carboxylic acid-resin composites. The carboxylic acid was a monofunctional methacryloxyethyl phthalate (MEP). Five mass fractions of whisker/(whisker + fluorosilicate glass), and corresponding resin (resin + MEP), were evaluated. Four control materials were also tested for comparison: a glass ionomer, a resin-modified glass ionomer, a compomer, and a hybrid composite resin. Flexural specimens were fabricated to measure the flexural strength, elastic modulus, and work-of-fracture (an indication of toughness). Fluoride release was measured by using a fluoride ion selective electrode. The properties of whisker composites depended on the whisker/(whisker + fluorosilicate glass) mass fraction. At a mass fraction of 0.8, the whisker composite had a flexural strength in MPa (mean +/- sd; n = 6) of 150 +/- 16, significantly higher than that of a glass ionomer (15 +/- 7) or a compomer control (89 +/- 18) (Tukey's multiple comparison test; family confidence coefficient = 0.95). Depending on the ratio of whisker:fluorosilicate glass, the whisker composites had a cumulative fluoride release up to 60% of that of a traditional glass ionomer. To conclude, combining ceramic whiskers and fluorosilicate glass in a carboxylic acid-resin matrix can result in fluoride-releasing composites with significantly improved mechanical properties.

Analysis of Variance↗

Lubrication and cartilage.

Mechanisms of lubrication of human synovial joints have been analysed in terms of the operating conditions of the joint, the synovial fluid and articular cartilage. In the hip and knee during a walking cycle the load may rise up to four times body weight. In the knee on dropping one metre the load may go up to 25 time body weight. The elastic modulus of cartilage is similar to that of the synthetic rubber of a car tyre. The cartilage surface is rough and in elderly specimens the centre line average is 2-75 mum. The friction force generated in reciprocating tests shows that both cartilage and synovial fluid are important in lubrication. The viscosity-shear rate relationships of normal synovial fluid show that it is non-Newtonian. Osteoarthrosic fluid is less so and rheumatoid fluid is more nearly Newtonian. Experiments with hip joints in a pendulum machine show that fluid film lubrication obtains at some phases of joint action. Boundary lubrication prevails under certain conditions and has been examined with a reciprocating friction machine. Digestion of hyaluronate does not alter the boundary lubrication, but trypsin digestion does. Surface active substances (lauryl sulphate and cetyl 3-ammonium bromide) give a lubricating ability similar to that of synovial fluid. The effectiveness of the two substances varies with pH.

Cartilage, Articular↗

Material properties of human infant skull and suture at high rates.

Clinicians are often faced with the challenging task of distinguishing between accidental and inflicted pediatric head trauma. There is currently a disparity in the anecdotal case study literature as to what kinds of injuries can occur in children from low height falls. There is also a paucity of material property data for pediatric skull and suture at rates similar to those expected in low height falls. We tested human infant (<1 year old) cranial bone and suture from 23 calveria in three-point bending and tension, respectively, at rates ranging from 1.2-2.8 m/sec. Donor age was found to have the largest influence on the elastic modulus and ultimate stress of cranial bone, with an increase in age increasing both material properties. In adults, cranial bone and suture have similar properties and the adult calveria deforms very little prior to fracture. In contrast, pediatric cranial bone is 35 times stiffer than pediatric cranial suture. In addition, pediatric cranial suture deforms 30 times more before failure than pediatric cranial bone and 243 times more than adult cranial bone. The large strains in the pediatric bone and suture result in a skullcase that can undergo dramatic shape changes before fracture, potentially causing substantial deformation in the brain. The sizeable difference between pediatric bone and suture material properties also underscores the crucial role that sutures play in the unique response of the pediatric head to impact in low height falls. These data provide necessary information to enhance our understanding of mechanisms of head injury in young children.

Aging↗

Mechanical properties, density and quantitative CT scan data of trabecular bone with and without metastases.

Pathologic fracture of the hip due to metastatic lesions in bone is a serious problem. This study examined the effect of metastatic lesions on the material properties and quantitative computed tomography (QCT) data of trabecular bone. Twelve distal femora were obtained, four with lytic and/or blastic metastatic lesions (group L), four without lesions but from donors who died from breast, prostate, or lung cancer (group NL), and four from donors with no cancer (group NC). Each specimen was CT scanned, and 56, 15x15x15-mm cubes of trabecular bone were cut. QCT density (rho(QCT)), compressive elastic modulus (E), compressive yield and ultimate strengths (S(y) and S(u)), and ash density (rho(ash)) of each cube were determined. Regression analysis was performed between rho(ash) and E, S(y), S(u) and rho(QCT), and analysis of covariance was used to identify differences between groups. Power relationships that did not depend on group (p >/= 0.1) were found between E and rho(ash) (0.74 </= r </= 0.84; p<0.001) and between strength (S(y) and S(u)) and rho(ash) (r >/= 0.94; p<0.001). rho(ash) was strongly related to rho(QCT) (r >/= 0.99; p<0.001). These results indicate that metastatic disease does not significantly impair the ability of QCT to provide an accurate and precise estimate of rho(ash) that can be used to estimate mechanical properties of trabecular bone with and without metastases.

Aged↗

Binding of avidin modified antibody to biotinylated metal supported membranes and liposomes changes the physical properties of lipid bilayer.

Various methods have been applied to study the physical properties of metal supported bilayer lipid membranes (s-BLM) and large unilamellar liposomes containing biotinylated phospholipids during the binding of IgG modified by avidin. Electrostriction method applied to s-BLM showed that addition of avidin-IgG (A-IgG) complex in a small concentration (0.2 mumol/l) resulted in an approximately twofold decrease of membrane capacitance, C, increase of elasticity modulus in direction perpendicular to the membrane plane, E perpendicular, by 5-20%, increase in intrinsic membrane potential, delta phi m, by approximately 30 mV, and an approximately 5-15% increase of the coefficient of dynamic viscosity, eta. The method of ultrasonic velocimetry showed that addition into the suspension of liposomes of unmodified IgG did not induce any changes in ultrasound velocity, while addition of A-IgG complex in a concentration range of 0-1 mumol/l led to an increase of the velocity number [u]. The plot of changes of [u] versus A-IgG concentration has a tendency to saturate at concentrations above 0.5 mumol/l, which suggests long-range interactions in the membrane induced by strong binding of A-IgG to the biotin sites on the membrane. Probably, this binding leads to a decrease of the coefficient of adiabatic compressibility of liposomes.

Avidin↗