PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Masseter Muscle”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

[Ultrasonography. Interpretation of physiologic structures of the neck and face].

Ultrasonography is one of the newest diagnostic methods for the visualization of pathologic conditions of the soft tissues of the human body. This method has an indication also for the localization and diagnosis of benign and malignant lesions in the head and neck area. This study was done in order to inform the dentist about this new and completely safe diagnostic method and also, to present the sonographic image of the physiologic structures in the head and neck area. Ultrasonography was performed in 20 persons who had a free past medical history and no sign of disease in the head and neck area. Attention was made in order to include in the study persons of all ages, of different weight and of both sexes in order to include any possible variation of the anatomic order. The examination was done with Aloka S.S.D.-280 L.S. ultrasound camera and the probe applied was the US - 5 MHz and connected with the Echo-Coupler ECM-1, which was used for the first time in Greece. Ultrasonographic examination was made in the submandibular, sublingual, parotid and neck region and the physiologic structures, which were studied, included the thyroid, the sternocleidomastoid muscle, the carotid artery and jugular vein, muscles of the submandibular area, the sublingual, submandibular and parotid salivary glands and the masseter muscle.

Carotid Arteries↗

Nocturnal masseter and suprahyoid muscle activity induced by wearing a bionator.

The purpose of this study was to examine the effect of a bionator on masseter and suprahyoid muscle activities during sleep. Ten healthy Japanese males (mean age: 26.3 years) participated in this study. Electromyographic (EMG) activities of the right masseter and bilateral suprahyoid muscles were recorded during sleep with and without a bionator. Although no significant changes were observed in the maximal EMG activities of these muscles, the maximal EMG activity of suprahyoid muscles tended to decrease while wearing the bionator. The number of events over 40% maximal voluntary contraction (MVC) tended to decrease in these muscles with a bionator, but these changes were not statistically significant. These findings indicate that there are no significant changes or there is only a tendency to decrease the activities of the masseter and suprahyoid muscles while wearing a bionator during sleep.

Activator Appliances↗

Involvement of reticular neurons located dorsal to the facial nucleus in activation of the jaw-closing muscle in rats.

The location of excitatory premotor neurons for jaw-closing motoneurons was examined by the use of electrical and chemical stimulation and extracellular single-unit recording techniques in the anesthetized rat. Single-pulse electrical stimulation of the supratrigeminal region (SupV) and the reticular formation dorsal to the facial nucleus (RdVII) elicited masseter EMG response at mean (+/-SD) latencies of 2.22 +/- 0.59 ms and 3.10 +/- 1.14 ms, respectively. Microinjection (0.1-0.3 microl) of glutamate (50 mM) or kainate (0.5-100 microM) into RdVII increased masseter nerve activity in artificially ventilated and immobilized rats by 30.2 +/- 40.5% and 50.7 +/- 46.8% compared to baseline values, respectively. Forty reticular neurons were antidromically activated by stimulation of the ipsilateral trigeminal motor nucleus (MoV). Twenty neurons were found in RdVII, and the remaining 20 neurons were located in SupV, or areas adjacent to SupV or RdVII. Eleven neurons in RdVII responded to at least either passive jaw opening or light pressure applied to the teeth or tongue. Nine neurons responded to passive jaw opening. Five of the nine neurons responded to multiple stimulus categories. A monosynaptic excitatory projection from one neuron in RdVII was detected by spike-triggered averaging of the rectified masseter nerve activity. We suggest that reticular neurons in RdVII are involved in increasing masseter muscle activity and that excitatory premotor neurons for masseter motoneurons are likely located in this area. RdVII could be an important candidate for controlling activity of jaw-closing muscles via peripheral inputs.

Action Potentials↗

Modulation of H reflexes in the forearm during voluntary teeth clenching in humans.

We investigated whether there is any modulation of the H reflex in the forearm during teeth clenching and how any correlation that may be found is modulated. The H reflexes of the flexor carpi radialis (FCR) and the extensor carpi radialis (ECR) muscles were evoked on the right side in five healthy adult volunteers. The H reflexes of the FCR and ECR muscles were facilitated in association with voluntary teeth clenching in a force-dependent manner ( r=0.46-0.663, P<0.05). The increase in amplitude of the H reflex of the FCR muscle associated with teeth clenching started before the onset of the EMG activity of the masseter muscle. The results of the present study demonstrate that oral motor activity exerts strong influences on the motor activity of the forearm.

Adult↗

Influences of periodontal and mandibular-joint receptors on reflex sensitivity of human jaw-closing muscles.

Reflex sensitivity from stimulating the chin or the dental arch of the mandible and the influences of periodontal and mandibular joint receptors on jaw muscles were investigated by experiments with and without anaesthesia. The findings showed that periodontal receptors exert an inhibitory influence on motoneural excitability of jaw-closing muscles and facilitate alpha-motoneurones of the digastric muscle and that the silent period following a jaw jerk is partly caused by inhibition of alpha-motoneurones of jaw-closing muscles due to activity of periodontal receptors. The ratio of reflex activity in temporal and masseter muscles appeared to depend on the position of the applied stimulus. The mandibular joint receptors appear to play a major part in distributing active muscle-force over these muscles.

Adult↗

Effects of NK433, a new centrally acting muscle relaxant, on masticatory muscle reflexes in rats.

The effects of (-)-(R)-2-methyl-3-(1-pyrrolidinyl)-4'- trifluoromethylpropiophenone monohydrochloride (NK433), a novel centrally acting muscle relaxant, on masticatory muscle reflexes were investigated in rats. NK433 inhibited the monosynaptic tonic vibration reflex of the masseter muscle and the polysynaptic tonic periodontal masseteric reflex. These reflexes are increased by gamma-motor activity. NK433 had a weak inhibitory effect on the polysynaptic jaw opening reflex evoked by electrical stimulation of the tooth pulp, which is little related with gamma-motor activity. Eperisone-HCl depressed the three types of masticatory muscle reflexes. When intravenously administered, eperisone-HCl was equipotent to NK433, but the effect of eperisone-HCl was shorter-lasting than that of NK433. The effect of intragastrically administered NK433 on the periodontal masseteric reflex was about three times stronger than that of eperisone-HCl. These results suggest that NK433 inhibits masticatory muscle reflexes controlled by the gamma-motor system and thus may ameliorate the temporomandibular joint syndrome in man.

Animals↗

Quantitative calculations of temporomandibular joint reaction forces--II. The importance of the direction of the jaw muscle forces.

The effect of error in determination of muscle force direction on quantitative calculation of the temporomandibular joint reaction force was investigated in a two-dimensional, two-muscle model. A computer program using the model incremented the direction of the temporalis and masseter muscle force vectors and generated a family of curves showing the relationship between muscle force direction and the direction and magnitude of the temporomandibular joint reaction force. The major effect of muscle force direction is its influence on the length of the muscle force moment arm. The analyses show that calculation of the joint reaction force is much more sensitive to errors in muscle force direction than to muscle force magnitude. Calculation of the magnitude of the joint reaction force is less sensitive to error than the calculation of joint reaction force direction. An error of 1 degree in muscle force direction could produce a 2 degrees error in joint force direction. No ideal location of the muscle force vectors was found. Vector positions that enhanced calculation of joint force magnitude increased the sensitivity to errors when calculating joint force direction. The difficulties of precisely determining muscle force directions are discussed. The present results indicate that a two-muscle model requires very precise determination of muscle force directions to reliably calculate the temporomandibular joint reaction forces.

Biomechanical Phenomena↗

Forces applied during laryngoscopy in children. Are volatile anaesthetics essential for suxamethonium induced muscle rigidity?

Increased masticatory muscle tone after administration of suxamethonium has been demonstrated in children when combined with volatile anaesthetics. Whether volatiles are a prerequisite for this phenomenon is not known. In this study upper airway muscle tone, including the tone of the masticatory muscles, was determined in 54 children (age range 2-15 years), anaesthetized with propofol, fentanyl and nitrous oxide and avoiding any use of volatiles. The children were either relaxed with suxamethonium (n = 26) or vecuronium (n = 28). The forces applied during laryngoscopy were used to quantify upper airway muscle tone and were significantly greater in the suxamethonium group than in the vecuronium group: maximally applied force was 25 N versus 21 N (P = 0.008), and mean applied force was 16 N versus 13 N (P = 0.006), respectively. The results of this study indicate that upper airway muscle tone increases after administration of suxamethonium in children independent of the presence of volatile anaesthetics. Moreover, increased muscle tone had no effect on the difficulty of laryngoscopy or the intubation conditions. Increased masseter muscle rigidity after suxamethonium could be due to the very unique characteristics of this muscle.

Adolescent↗

[Synchronization of electromyographic and cinematographic recordings. Applications to vertebrate biomechanics].

Synchronizing each frame of the cinema of a moving animal with the corresponding EMG of some muscles permits a precise interpretation of the variations of the electric potentials in that muscle with each phase of the movement. e.g. in the rabbit, three bundles of the masseter muscle function independently during the mastication; in the pigeon, electric potentials appear in both ilio-tibialis and biceps femoris muscles some frames before the actual raising of the leg, when the animal on its perch becomes out of balance.

Animals↗

Zygomaticomandibularis muscle.

The aim of this study was to elucidate the precise anatomy of the zygomaticomandibularis muscle through cadaveric dissection and magnetic resonance imaging (MRI). Five fresh human cadavers and 10 fixed cadavers were dissected. Nine preserved human cadavers were used for the MRI study. Four volunteers took MRIs of their head as well. Zygomaticomandibularis muscle was found in all the cadaveric specimens. It is a fan shaped muscle. The length of the muscle is 25.1 +/- 4.6 mm, and the width at the zygomatic arch is 16.6 +/- 4.2 mm. The thickness is approximately 4.8 +/- 1.9 mm. It originates from the deep layer of the deep temporal fascia approximately 1 cm above the zygomatic arch and is inserted into the superior border and outer surface of the mandible between the coronoid process and mandibular notch. The deepest layer of the masseter muscle covers the lateral surface of zygomaticomandibularis. We believe that this muscle functions as coordinator of the temporalis and masseter in mammals with strong masticatory power but is a degraded or rudimentary muscle in humans.

Cadaver↗

[Respondence to electricity in the muscles of rat's jaw].

15 male Wistar rats of 8 weeks old were used in this experment. After deeply anesthesia, the masseter muscles, digastric muscles, lateral pterygoid muscles were stimulated in the apartment that was made by us. The curves that express the relations of force-electronic stimulates were recorded and the constitutive equations of these muscles were given. When a single electronic signal stimulates the muscle, the respondence of the muscles can be expressed as F = A(e-alpha t - e-beta t) and the constant A, alpha, beta were determined. When the frequency of the electronic stimulation was higher than 3 Hz, the respondence was expressed as F = Ce-gamma/t + Dsin omega t and the constants C, D and gamma were determined. When the frequency of the electronic stimulation was thirty or higher, the tetanic convulsion occurred.

Animals↗

Length-tension relationships of masseter and digastric muscles of miniature swine during ontogeny.

At incremental whole muscle lengths, active isometric and passive elastic forces were recorded from the masseter and digastric muscles of anaesthetized miniature pigs (Hanford) weighing 2.0-20.0 kg. Wet muscle mass and maximum tetanic tension values for masseter exceed those for digastric and increase more rapidly with body mass (age). At any body mass, masseter exceeds digastric in the ratio of optimum length (that length at which maximum tetanic tension is produced) to in situ muscle length (that length which corresponds to the jaw in a closed position) and the proportion of passive tension comprising total (passive plus active) tension. Passive elastic tension begins to rise in masseter at lengths as short as 87% of optimum (in younger pigs). In digastric, passive tension is absent until the muscle is stretched to a length slightly longer than optimum in younger pigs but occurs at shorter lengths in older pigs. Contractile properties explain functional differences between masseter and digastric more clearly than they explain ontogenetic changes in either muscle. The behavioural transition from infant suckling to adult mastication of solid food is best characterized by a disproportionate increase in mass (and force) of the masseter, relative to digastric, and increased reliance upon active (rather than passive) tension.

Aging↗

Investigating the contamination of electroencephalograms by facial muscle electromyographic activity using matching pursuit.

It has been widely recognized and previously reported that electrical fields from facial muscle electromyographic (EMG) activity can contaminate the electroencephalogram (EEG), even when closely spaced, bipolar electrode configurations are used (personal observations). We suspected that EEG signals evoked in response to pressure changes in the upper airway may include EMG contamination subsequent to muscle reflexes triggered by the stimuli. We evaluated the potential contamination of the background EEG by voluntary activation of a facial muscle by obtaining simultaneous recordings in human subjects of the EEG (from Cz-C4) and masseter muscle EMG (from a bipolar surface electrode pair) before (quiet) and after voluntary tensing (VTen). Matching pursuit analysis permitted identification of different time-frequency patterns for each signal during the quiet period because the EMG signal has mostly atoms above 30 Hz compared to the EEG signal. However, the EEG showed periods of low-frequency activity unmatched in the EMG TF pattern below 30 Hz. During the tensing, most of the atoms of both the EEG and EMG shifted to the higher frequency regions above 100 Hz, making the separation difficult. These results further suggest that the matching pursuit method may not separate the background EEG from phasic EMG signals, both of which are nonstationary in nature.

Artifacts↗

Relationship between tubal function, craniofacial morphology and disorder of deglutition.

26 children without hearing impairment have been examined by otolaryngologists and orthodontists. According to the tubal function test in a pressure chamber they were classifed into a group with good and poor tubal function. The E.N.T. examination was unconclusive for a possible relationship between rhinological findings, mode of breathing, sinusitis, size of tonsils, nasal airway resistance and tubal function. Adenoids proved to be a mechanical impairment for active tubal function as stated by many authors. The cephalometric analysis of lateral head films combined with a static and dynamic-functional evaluation of tongue posture revealed significant differences between children with good and poor tubal function. Subjects with a vertical craniofacial growth pattern seem to be predisposed for poor tubal function. Analysing static tongue posture in children with poor tubal function the tongue lies more retracted in a backward position. The back of the tongue is flattened in relation to the palatal arch. In children with good tubal function there is a much closer contact between the back of tongue and the hard palate. Subjects with poor tubal function have an increased incidence of abnormal deglutition combined with tongue-thrust, teeth-apart swallowing, lack of sealing off the anterior oral cavity and contraction of the circumoral musculature. In children with good tubal function one can find the somatic type of swallowing that means no contractions of the circumoral muscles, no tongue-thrust during deglutition but contact of the molars and contraction of the masseter muscle.

Airway Resistance↗

The influence of altered working-side occlusal guidance on masticatory muscles and related jaw movement.

The effect of four different occlusal situations (group function, canine guidance, working side occlusal interference, and hyperbalancing occlusal interference) on EMG activity in jaw elevator muscles and related mandibular movement was investigated on 12 subjects. With a computer-based system, EMG and displacement signals were collected simultaneously during specific functional (unilateral chewing) and parafunctional tasks (mandibular gliding movements and various tooth clenching efforts) and analyzed quantitatively. When a naturally acquired group function was temporarily and artificially changed into a dominant canine guidance, a significant general reduction of elevator muscle activity was observed when subjects exerted full isometric tooth-clenching efforts in a lateral mandibular position. The original muscular coordination pattern (relative contraction from muscle to muscle) remained unaltered during this test. With respect to unilateral chewing, no significant alterations in the activity or coordination of the muscles occurred when an artificial canine guidance was introduced. Introduction of a hyperbalancing occlusal contact caused significant alterations in muscle activity and coordination during maximal tooth clenching in a lateral mandibular position. A marked shift of temporal muscle EMG activity toward the side of the interference and unchanged bilateral activity of the two masseter muscles were observed. The results suggest that canine-protected occlusions do not significantly alter muscle activity during mastication but significantly reduce muscle activity during parafunctional clenching. They also suggest that non-working side contacts dramatically alter the distribution of muscle activity during parafunctional clenching, and that this redistribution may affect the nature of reaction forces at the temporomandibular joints.

Adult↗

Trigeminal P2X3 receptor expression differs from dorsal root ganglion and is modulated by deep tissue inflammation.

The distribution and modulation of the P2X(3) receptor was studied in trigeminal ganglion neurons to provide insight into the role of ATP in craniofacial sensory mechanisms. Binding to the d-galactose specific lectin IB4 was found in 73% of P2X(3)-positive neurons while only 16% of IB4 neurons expressed P2X(3). Neurons expressing P2X(3) alone were significantly larger than IB4-or IB4/P2X(3)-positive neurons. Investigation of target-specificity revealed that 22% of trigeminal ganglion muscle afferent neurons were positive for P2X(3) versus 16% of cutaneous afferent neurons. Muscle P2X(3) afferents were significantly smaller than the overall muscle afferent population while P2X(3) cutaneous afferent neurons were not. Presumptive heteromeric (P2X(2/3)) muscle afferent neurons were also identified and comprised 77% of the P2X(3) muscle afferent population. Muscle afferent neurons co-expressed P2X(3) with either calcitonin gene-related peptide (15%) or substance P (4%). The number of P2X(3)-positive muscle afferent neurons significantly increased one and four days following complete Freund's adjuvant-induced masseter muscle inflammation, but significantly decreased after 12 days. These results indicate that within trigeminal ganglia: (1) the P2X(3) receptor is expressed in both small and medium-sized neurons; (2) the P2X(3) receptor is not exclusively expressed in IB4 neurons; (3) P2X(3) is co-expressed with neuropeptides; (4) differences in the proportion of cutaneous versus muscle P2X(3) afferents are not apparent. Trigeminal P2X(3) neurons therefore differ markedly from dorsal root ganglion P2X(3) afferents. This study also shows that deep tissue inflammation modulates expression of the P2X(3) receptor and thus may warrant exploration as a target for therapeutic intervention.

Animals↗

Ca2+ ATPase in Dutch warmblood foals compared with Na+, K+ ATPase: intermuscular differences and the effect of exercise.

We studied the effects of exercise without or with a subsequent period on pasture on Ca2+ ATPase concentration in foal skeletal muscle, and compared the results with those previously reported on Na+, K+ ATPase. Ca2+ ATPase was measured in homogenates as Ca2+-dependent steady-state phosphorylation from [gamma-32P]ATP. From day 7 after birth, 24 foals were divided into three groups: (i) staying in a box stall (Box); (ii) staying in a box stall with an exercise programme of an increasing number of sprints per day (Exercise); and (iii) staying on pasture (Pasture). Half of the foals (12 with four in each treatment group) were killed after 5 months. The remaining foals stayed on pasture until 11 months. In the 5-month Pasture group, Ca2+ ATPase concentration was 29.4 +/- 4.3 nmol/g wet weight (wt) (n = 4) in gluteus medius muscle, 25.2 +/- 3.3 nmol/g wet wt (n = 4) in semitendinosus muscle (both mixed fibre type), and 4.1 +/- 1.7 nmol/g wet wt (n = 3) in the slow masseter muscle. These values were not altered by exercise or by box rest. This was in contrast to the Na+, K+ ATPase concentration which was not different between the three muscles, but showed a 20% rise in gluteus medius and semitendinosus muscle after exercise. In the period from 5 to 11 months on pasture, there was no change in Ca2+ ATPase in any group. In conclusion, the Ca2+ ATPase concentration in foal muscle is around 6-fold higher in mixed fibres than in slow fibres. Furthermore, the enzyme is not up- or down-regulated by sprint exercise or subsequent rest.

Animals↗