PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Understanding computerized EEG monitoring in the intensive care unit.

Computerized EEG (CEEG) monitoring has recently been introduced to intensive care units (ICU). Unlike the intermittent assessment using coma scales, CEEG monitoring provides continuous information about a patients' neurological condition. Patient status can be monitored more accurately with CEEG. The use of CEEG monitoring has been proposed for those patients who may experience a decline in cerebral blood flow related to increased intracranial pressure (ICP) or other ischemic events. CEEG is also used in status epilepticus, non-convulsive seizures, metabolic disorders, intracerebral tumors and all etiologies of coma. The goal of continuous CEEG monitoring is to recognize a decline in a patient's condition before physical signs and symptoms are present. The neuroscience nurse participates in the assessment of the EEG recording as well as in evaluating therapy. This article introduces the neuroscience nurse to the basic terminology, rationale for use and clinical application for continuous computerized EEG monitoring.

Brain Damage, Chronic↗

An open architecture patient monitoring system using standard technologies.

Computer-aided bedside patient monitoring is applied in areas where real-time vital function analysis takes place. Modern bedside monitoring requires not only the networking of bedside monitors with a central monitor but also other standard communication interfaces. In this paper, a novel approach to patient monitoring is introduced. A patient monitoring system was developed and implemented based on an existing industry standard communication network, using standard hardware components and software technologies. The open architecture system design offers scalability, standard interfaces, and flexible signal interpretation possibilities.

Computers↗

Clinical comparison of three different anaesthetic depth monitors during cardiopulmonary bypass.

The lack of a gold standard complicates the evaluation and comparison of anaesthetic depth monitors. This randomised study compares three different depth-of-anaesthesia monitors during cardiopulmonary bypass (CPB) at 34 degrees C with fentanyl/propofol anaesthesia adjusted clinically and blinded to the monitors. Coronary artery bypass grafting patients (n = 21) were randomly assigned to all three possible paired combinations of three monitors: Bispectral Index (Aspect Medical), AAI auditory evoked potential (Danmeter), Entropy (Datex-Ohmeda). Indices were manually recorded every 5 min during CPB. Agreement between paired indices was classified as good, non-, or disagreement. Anaesthesia was classed as adequate, inadequate, or excessive according to recommended index values. Of the 255 paired indices recorded, 62% showed good agreement, 33% showed non-agreement, and 5% showed disagreement. Using good agreement between two monitors as a gold standard, a quarter of the measurements indicate inappropriate anaesthetic depth monitoring during CPB with clinically titrated anaesthetic depth.

Adult↗

A randomised controlled trial of the effect of continuous electronic physiological monitoring on the adverse event rate in high risk medical and surgical patients.

We conducted a randomised controlled trial of mandated five-channel physiological monitoring vs standard care, in acute medical and surgical wards in a single UK teaching hospital. In all, 402 high-risk medical and surgical patients were studied. The primary outcome was the proportion of patients experiencing one or more major adverse events, including urgent staff calls, changes to higher care levels, cardiac arrests or death, in 96 h following randomisation. Secondary outcomes were the proportion of patients requiring acute treatment changes, and the 30-day and hospital mortality. In the 96 h following randomisation, 113 (56%) patients in the monitored arm and 116 (58%) in the control arm (OR 0.94, 95% CI 0.63-1.40, p = 0.76) had a major event. An acute change in treatment was necessary in 107 (53%) monitored patients and 101 (50%) control patients (OR 0.55, 95% CI 0.87-1.29). Thirty-four (17%) monitored patients and 35 (17%) control patients died within 30 days. Thirteen patients in the control group received full five-channel monitoring at the request of the ward staff. We conclude that mandated electronic vital signs monitoring in high risk medical and surgical patients has no effect on adverse events or mortality.

Adult↗

Continuous non-invasive end-tidal CO2 monitoring in pediatric inpatients with diabetic ketoacidosis.

INTRODUCTION: Pediatric inpatients with diabetic ketoacidosis (DKA) are routinely subjected to frequent blood draws in order to closely monitor degree of acidosis and response to therapy. The typical level of acidosis monitoring is less than ideal, however, because of the high cost and invasiveness of frequent blood labs. Previous studies have validated end-tidal carbon dioxide (EtCO2) monitoring in the emergency department (ED) for varying periods of time. We extend these findings to the inpatient portion of the hospitalization during which the majority of blood tests are sent. METHODS: All patients admitted to an intermediate care unit in (InCU) a large children's hospital were fitted with an appropriately sized oral/nasal cannula capable of sensing EtCO2. Laboratory studies were obtained according to hospital clinical practice guidelines. In a retrospective analysis, EtCO2 values were correlated with serum total CO2 (stCO2), venous pH (vpH), venous pCO2 (vpCO2), and calculated bicarbonate from venous blood gas (vHCO3-). RESULTS: A total of 78 consecutive episodes of DKA in 72 patients aged 1-21 yr were monitored for 3-38 h with both capnography and laboratory testing, producing 334 comparisons. Initial values were as follows, reported as median (range): stCO2, 11 (4-22) mmol/L; vpH, 7.281 (6.998-7.441); vpCO2, 28.85 (9.3-43.3) mmHg; and vHCO3-, 14 (3-25) mmol/L. EtCO2 was correlated well with stCO2 (r = 0.84, p < 0.001), vHCO3- (r = 0.84, p < 0.001), and vpCO2 (r = 0.79, p < 0.001). CONCLUSIONS: These data support the findings of previous studies limited to ED populations and suggest that non-invasive EtCO2 monitoring is a valuable and reliable tool to continuously follow acidosis in the setting of the acutely ill pediatric patient with DKA. Continuous EtCO2 monitoring offers the practitioner an early warning system for unexpected changes in acidosis that augments the utility of intermittent blood gas determinations.

Adolescent↗

Intraoperative measurement of activated partial thromboplastin time and prothrombin time with a new compact monitor.

A prospective study was conducted to evaluate a new compact portable coagulation monitor (Ciba-Corning Biotrack 512 Monitor), which enables the clinician to perform instantaneous activated partial thromboplastin time (APTT) and prothrombin time (PT). 126 patients scheduled for heparinized and nonheparinized vascular surgery, and gynaecological surgery, were included. A drop of capillary or venous whole blood was applied in disposable cartridges to successively perform APTT and PT, and the results of the tests were compared with conventional laboratory methods, performed in two different laboratories (Lab. A and B). Comparisons between Lab. A. and Lab. B. enables determination of the bias, precision, and percent of outliers (patients whose values differed more than 20%) in conventional methods. The reference value was defined as the mean of Lab. A. and Lab. B. values. For PT, there were no statistical differences between the capillary and venous samples performed with the portable monitor, and the reference value, for the bias, the precision and the proportion of outliers. For APTT, there were no statistical differences between the capillary and venous samples performed with the portable monitor, and the reference value, for the bias and the precision. The percent of outliers, however, was significantly greater with the venous sample of the compact monitor than with the reference (48 versus 22%), and even if it did not reach the statistical significance (P = 0.07) it was also higher with the capillary sample performed with the Ciba Monitor than with the reference (33%).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Comparison of long-term monitoring and standard cystometry in chronic retention of urine.

Twenty-eight men with chronic retention of urine were investigated by means of a standard medium fill cystometrogram and by long-term monitoring of bladder pressure whilst the bladder filled naturally. Effective cystometric capacity was greater in each patient during standard cystometry (297 +/- 180 ml) than during long-term monitoring (99 +/- 100 ml; P less than 0.002). The incidence of detrusor instability was also greater during long-term monitoring than during standard cystometry (P less than 0.01). During filling, the detrusor pressure increased significantly both in standard cystometry (27.9 +/- 22.8 cmH2O; P less than 0.002) and in long-term monitoring (4.9 +/- 6.5 cmH2O; P less than 0.002). The detrusor pressure rise during filling was significantly greater during the standard cystometrogram than during long-term monitoring (P less than 0.002). Even when the detrusor pressure rise was corrected to take account of the different cystometric capacities this difference persisted (P less than 0.05). High end filling pressures are common in men with chronic retention investigated by means of a standard cystometrogram but are not observed during long-term monitoring. Such high pressures are probably due to the unphysiological rates of filling and the large volumes of fluid instilled during standard cystometry.

Aged↗

Ambulatory monitoring of the ST segment in diabetic men with and without peripheral neuropathy.

To assess whether myocardial ischaemia is more common in diabetic patients with neuropathy, 24-hour ambulatory monitoring of the ST segment was performed on 27 diabetic men without peripheral neuropathy and in 28 with neuropathy. The patients were matched for age 54 +/- 7 years (mean +/- SD) versus 54 +/- 7 years and for duration of diabetes (16 +/- 9 years versus 16 +/- 12 years). None had clinical evidence of heart disease. Episodes of ST segment depression were seen during ambulatory monitoring in 12 diabetics (22%) but were not more common in patients with peripheral neuropathy. Four of the 13 diabetics with autonomic neuropathy had ST depression during ambulatory monitoring. During a median follow-up period of 50 months, four patients developed clinical heart disease. Three of these patients had shown ST depression during ambulatory monitoring. ST depression during ambulatory monitoring is common in diabetic men without cardiac symptoms but is not related to the presence of peripheral neuropathy. Diabetics with ST depression during ambulatory monitoring are at increased risk of developing heart disease in subsequent years.

Coronary Disease↗

Home glucose monitoring in type 2 diabetes: is it a waste of time?

A cross-sectional study to assess home glucose monitoring practices was conducted in 200 non-insulin-treated diabetic patients consecutively attending our hospital clinic. Of the 200, 97 (48%) patients (Group 1) regularly monitored urine (n = 74), blood (n = 19) or both (n = 4); 103 (52%) patients (Group 2) performed no home monitoring. The two groups were similar in terms of age, sex, duration of diabetes and type of treatment. The prevalence of diabetic complications was also closely comparable and only peripheral neuropathy differed between the groups, being more common in Group 1 (n = 12) than Group 2 (n = 4); p < 0.05. There was also no significant difference between the HbA1 concentration (mean +/- SD) in Group 1 (9.7 +/- 2.2%) and Group 2 (9.4 +/- 2.0%). The mean frequency of home monitoring was four tests weekly, but only 21 (22%) kept a written record and 60 (62%) would never alter their treatment on the basis of their results. Almost a third of patients could not interpret the results of monitoring or give the normal range of values. Home glucose monitoring, particularly of urine, is widely practised in Type 2 diabetes, at considerable overall expense. However, convincing evidence of its value in helping patients improve their blood glucose control or preventing the complications of the disease is lacking.

Blood Glucose↗

Sick day management using blood 3-hydroxybutyrate (3-OHB) compared with urine ketone monitoring reduces hospital visits in young people with T1DM: a randomized clinical trial.

AIMS: Diabetic ketoacidosis (DKA), a life-threatening acute complication of Type 1 diabetes, may be preventable with frequent monitoring of glycaemia and ketosis along with timely supplemental insulin. This prospective, two-centre study assessed sick day management using blood 3-hydroxybutyrate (3-OHB) monitoring compared with traditional urine ketone testing, aimed at averting emergency assessment and hospitalization. METHODS: One hundred and twenty-three children, adolescents and young adults, aged 3-22 years, and their families received sick day education. Participants were randomized to receive either a blood glucose monitor that also measures blood 3-OHB (blood ketone group, n = 62) or a monitor plus urine ketone strips (urine ketone group, n = 61). All were encouraged to check glucose levels > or = 3 times daily and to check ketones during acute illness or stress, when glucose levels were consistently elevated (> or = 13.9 mmol/l on two consecutive readings), or when symptoms of DKA were present. Frequency of sick days, hyperglycaemia, ketosis, and hospitalization/emergency assessment were ascertained prospectively for 6 months. RESULTS: There were 578 sick days during 21,548 days of follow-up. Participants in the blood ketone group checked ketones significantly more during sick days (276 of 304 episodes, 90.8%) than participants in the urine ketone group (168 of 274 episodes, 61.3%) (P < 0.001). The incidence of hospitalization/emergency assessment was significantly lower in the blood ketone group (38/100 patient-years) compared with the urine ketone group (75/100 patient-years) (P = 0.05). CONCLUSIONS: Blood ketone monitoring during sick days appears acceptable to and preferred by young people with Type 1 diabetes. Routine implementation of blood 3-OHB monitoring for the management of sick days and impending DKA can potentially reduce hospitalization/emergency assessment compared with urine ketone testing and offers potential cost savings.

3-Hydroxybutyric Acid↗

A multicenter randomized controlled trial on the clinical impact of therapeutic drug monitoring in patients with newly diagnosed epilepsy. The Italian TDM Study Group in Epilepsy.

PURPOSE: To assess the clinical impact of monitoring serum concentrations of antiepileptic drugs (AEDs) in patients with newly diagnosed epilepsy. METHODS: One-hundred eighty patients with partial or idiopathic generalized nonabsence epilepsy, aged 6 to 65 years, requiring initiation of treatment with carbamazepine (CBZ), valproate (VPA), phenytoin (PHT), phenobarbital (PB), or primidone (PRM) were randomly allocated to two groups according to an open, prospective parallel-group design. In one group, dosage was adjusted to achieve serum AED concentration within a target range (10-20 microg/ml for PHT, 15-40 microg/ml for PB, 4-11 microg/ml for CBZ, and 40-100 microg/ml for VPA), whereas in the other group, dosage was adjusted on clinical grounds. Patients were followed up for 24 months or until a change in therapeutic strategy was clinically indicated. RESULTS: Baseline characteristics did not differ between the two groups. Most patients with partial epilepsy were treated with CBZ, whereas generalized epilepsies were most commonly managed with PB or VPA. PHT was used only in a small minority of patients. A total of 116 patients completed 2-year follow-up, and there were no differences in exit rate from any cause between the monitored group and the control group. The proportion of assessable patients with mean serum drug levels outside the target range (mostly below range) during the first 6 months of the study was 8% in the monitored group compared with 25% in the control group (p < 0.01). There were no significant differences between the monitored group and the control group with respect to patients achieving 12-month remission (60% vs. 61%), patients remaining seizure free since initiation of treatment (38% vs. 41%), and time to first seizure or 12-month remission. Frequency of adverse effects was almost identical in the two groups. CONCLUSIONS: Only a small minority of patients were treated with PHT, the drug for which serum concentration measurements are most likely to be useful. With the AEDs most commonly used in this study, early implementation of serum AED level monitoring did not improve overall therapeutic outcome. and the majority of patients could be satisfactorily treated by adjusting dose on clinical grounds. Monitoring the serum levels of these drugs in selected patients and in special situations is likely to be more rewarding than routine measurements in a large clinic population.

Adolescent↗

Measurement of drug compliance by continuous electronic monitoring: a pilot study in elderly patients discharged from hospital.

OBJECTIVE: A pilot study to assess patient compliance with medication by using a new measurement technique, continuous electronic monitoring. DESIGN: Survey. Compliance monitors were provided to eligible patients at discharge from the hospital to measure drug intake behavior prospectively for a period of 3 weeks. SETTING: Ambulant patient care after discharge from a geriatric hospital, Krankenhaus Bethanien, which is affiliated with the University Clinic, Heidelberg. PATIENTS: A consecutive convenience sample of 18 independently living elderly patients (median age 76 years) completed the study. The patients were on maintenance therapy with cardiac glycosides and/or potassium-sparing diuretics prescribed to be taken once daily. INTERVENTION: The monitoring method provides information about patients' real timing of drug use by continuously recording date and time of openings and closings of the medication containers (monitors). In addition to a standard measure, the percentage of prescribed doses taken, information about regularity of drug use is obtained. RESULTS: Compliance, percentage of prescribed doses taken, was remarkably variable; it ranged from 24% to 100%, 95% CI: 62%-84%. Mean compliance declined from the first to the third week after discharge, 85% vs 69%, 95% CI: 74%-95% and 56%-81%, respectively (P < 0.05). Omissions of doses, the predominant pattern of non-compliance, were observed in 17 of 18 patients. Regularity of dose timing, as defined by the number of interdose intervals within 24 h +/- 15%, varied from 10% to 100%, 95% CI: 46%-76%. CONCLUSIONS: Continuous electronic monitoring revealed highly variable compliance in patients prescribed maintenance therapy. Even with a once-daily regimen, persistent and high compliance cannot be assumed. The monitoring technique may be of great value to research and, possibly, to practical therapeutic management.

Aged↗

Retrofitting technology to nursing: the case of electronic fetal monitoring.

OBJECTIVES: To describe how nurses put electronic fetal monitoring to use in the 1960s and 1970s and the dilemmas this caused. DESIGN: Social history. RESULTS: Nurses used electronic fetal monitoring to improve the watchful and comfort care of childbearing women, and they saw it as validating nursing. They retrofitted, or worked to reconcile machine monitoring with natural, prepared, and participative childbirth, and with attentive and embodied nursing. CONCLUSION: Electronic fetal monitoring was another in a long line of technological innovations that fell to nurses to put into use and to make work. The remarkably rapid way electronic fetal monitoring became routine in the United States depended, in large part, on the articulation work of nurses. However, like all such work, what nurses did to make electronic fetal monitoring work for patients, physicians, hospitals, and manufacturers was largely invisible. Retrofitting efforts often entail unrecognized innovation and risks for nursing.

Diffusion of Innovation↗

Wireless pH monitoring in patients with non-cardiac chest pain.

OBJECTIVES: Gastroesophageal reflux disease (GERD) is an important cause of non-cardiac chest pain (NCCP), and its detection can require ambulatory pH monitoring. The purpose of this study was to determine the advantages of a wireless ambulatory pH monitoring system and 2 days of recording in diagnosing GERD in NCCP patients. METHODS: Results from ambulatory pH studies using the BRAVO capsule were reviewed from 62 subjects referred for evaluation of NCCP after non-diagnostic response to proton pump inhibitor therapy. Acid exposure time (AET) and symptom-reflux association tests were calculated after 1 day of recording and compared to the final outcome from the 2-day study. RESULTS: Extending the recording time increased the number of subjects having elevated AET from 16 after 1 day to 22 after 2 days of recording, a 9.7% gain in subjects (95% CI 4.6-19.6%). The number of chest pain episodes doubled from 1 to 2 days, and 4 subjects (7.3%) developed symptoms only on the second day of monitoring. Statistically significant reflux-symptom association probabilities surfaced in an additional 13 subjects (21.0%; 95% CI 12.7-32.7%) by the conclusion of the 2-day study. The effect primarily was to identify significant associations in patients with lower proportions of reflux-associated symptoms. Taken together, 19.4% (95% CI 11.5-30.9%) of the subject group gained meaningful information suggesting a reflux diagnosis by extending the pH monitoring time to 2 days. CONCLUSIONS: Extending monitoring to 2 days with a wireless pH monitoring system increases the detection of GERD in a clinically significant proportion of patients with NCCP.

Adult↗

Technology review: Esophageal impedance monitoring.

Intraluminal impedance monitoring is a new technique that can be used to detect the flow of liquids and gas through hollow viscera. In combination with manometry, it is used for esophageal function testing and while manometry provides information on contractile activity, impedance provides information on esophageal bolus transit. This is especially useful in patients with nonobstructive dysphagia. However, impedance monitoring appears to be less suitable for the evaluation of patients with achalasia. When used in combination with esophageal pH monitoring, impedance monitoring makes gastroesophageal reflux monitoring more complete because it allows recognition of both acidic and weakly acidic reflux episodes. The results of several studies suggest that impedance-pH monitoring is useful in the evaluation of patients with PPI-resistant typical reflux symptoms, chronic unexplained cough, excessive belching, and rumination.

Electric Impedance↗

A pilot trial of BIS monitoring for procedural sedation in the emergency department.

OBJECTIVE: Procedural sedation is common in the ED. However, there is no objective physiologic parameter available to monitor a patient's conscious state. The Bispectral Index (BIS) monitor has been validated as an objective measure of depth of anaesthesia. We studied the BIS monitor for this role in procedural sedation. METHODS: A prospective, observational study with convenience sampling of adult patients in ED who underwent procedural sedation. Patients were treated according to standard practice and sedated as determined by the treating physician. Treating physicians were blinded to the BIS value. BIS values were recorded and compared to the Observer's Assessment of Alertness/Sedation Scale (OAAS). Upon recovery, patients were asked about recall of events while they were sedated. RESULTS: Twelve patients were enrolled and 110 paired readings from 11 patients (7 male) were obtained. It was not possible to obtain readings from one patient. The mean age was 58 years (range 20-94). The Spearman correlation between BIS and OAAS was 0.027 (95% CI -0.582-0.617). For the three patients who received propofol, the correlation was 1.0. There were no episodes of explicit recall of events during the period of sedation. CONCLUSIONS: BIS monitoring is feasible in the ED. Our small study suggests that there is a poor correlation between BIS values and the OAAS scale. Larger studies are required to further explore this relationship. Further developments in brain monitoring technology are also needed before this form of monitoring becomes clinically useful for procedural sedation.

Adult↗

Evaluation of ground water monitoring network by principal component analysis.

Principal component analysis is a data reduction technique used to identify the important components or factors that explain most of the variance of a system. This technique was extended to evaluating a ground water monitoring network where the variables are monitoring wells. The objective was to identify monitoring wells that are important in predicting the dynamic variation in potentiometric head at a location. The technique is demonstrated through an application to the monitoring network of the Bangkok area. Principal component analysis was carried out for all the monitoring wells of the aquifer, and a ranking scheme based on the frequency of occurrence of a particular well as principal well was developed. The decision maker with budget constraints can now opt to monitor principal wells which can adequately capture the potentiometric head variation in the aquifer. This was evaluated by comparing the observed potentiometric head distribution using data from all available wells and wells selected using the ranking scheme as a guideline.

Data Interpretation, Statistical↗

Monitoring well interception with fractures in clayey till.

When using monitoring wells for investigation of contaminant sources in clayey till, there is a high risk that fractures may cause mobile contaminants to bypass the monitoring wells. This paper indicates that the probability of interception between monitoring wells and hydraulic conductive fractures is often significantly less than 50%. Based on a field experiment and application of a calibrated discrete fracture matrix diffusion numerical model (FRAC3Dvs), the paper also evaluates pesticide-monitoring results for different positions of monitoring well screen relative to fractures. For well screens situated 0.25 and 2 m from a conductive fracture, the first concentrations of the pesticide metabolite (2,6 dichlorobenzamide, "BAM") would be measured two years and 18 years, respectively, after the contaminant had been transported into an underlying aquifer. In this way, underlying aquifers may be subjected to contamination by downward moving contamination without being observed in monitoring wells in the till.

Aluminum Silicates↗