PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring, Intraoperative”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Facial nerve outcome after acoustic neuroma surgery: a study from the era of cranial nerve monitoring.

The introduction of intraoperative cranial nerve monitoring in posterior fossa surgery has greatly aided the surgeon in identification and anatomic preservation of cranial nerves. As a result, the long-term function of the facial nerve continues to improve after removal of acoustic neuroma. Herein, we report our long-term (1 year or greater) facial nerve outcome in 129 patients who underwent surgical removal of their acoustic neuromas with the aid of intraoperative neurophysiologic monitoring between 1986 and 1990. The facial nerve was anatomically preserved in 99.2% of the patients, and 90% of all the patients had grade 1 or 2 facial nerve function 1 year after surgery. Long-term facial function was inversely correlated with the size of tumor (chi-squared, p < 0.02) and was not related to the side of tumor, the age and sex of the patient, or the surgical approach. In a comparison among tumor groups matched for size, no statistically significant difference in facial nerve outcome between the translabyrinthine and retrosigmoid approaches was detected. The proximal facial nerve stimulation threshold at the end of surgical removal was predictive of long-term facial nerve function (analysis of variance, p < 0.02). At 1 year, 98% (87 of 89) of the patients with electrical thresholds of 0.2 V or less had grade 1 or 2 facial nerve function compared with only 50% (8 of 16) of those with thresholds between 0.21 and 0.6 V. In the era of cranial nerve monitoring, patients can be better advised about long-term facial nerve outcome after surgical intervention. Preoperatively, the size of the tumor is the most critical factor in predicting long-term facial function. Postoperatively, the proximal seventh nerve stimulation threshold at the end of the surgical procedure can be used as one prognostic measure of long-term facial nerve function.

Adult↗

Application of artificial neural networks as an indicator of awareness with recall during general anaesthesia.

OBJECTIVE: Awareness with recall is a rare but serious complication of general anaesthesia with an incidence ranging from 0.1%-0.7%. In the absence of a reliable depth-of-anaesthesia monitor, attempts have been made to predict awareness from intraoperative haemodynamic monitoring data, with little success. Artificial neural networks can sometimes detect relationships between input and output variables even when conventional methods fail. Therefore, we subjected standard intraoperative monitoring data to both artificial neural models and conventional statistical methods in an attempt to predict awareness with recall. METHODS: Anaesthesia records from 33 patients with awareness and 510 patients without awareness were collected. Summary data (mean, maximum, and minimum) of end-tidal carbon dioxide concentration, arterial blood oxygen saturation, systolic and diastolic blood pressure, and heart rate were calculated for each patient. These data were subjected to an analysis by artificial neural networks and by Poisson regression. RESULTS: The two best neural models both had sensitivity and specificity of 23% and 98%, respectively. The models have high specificity, and in view of the low incidence of awareness, a high negative predictive value. The prediction probabilities P(k) (SE) for the best neural models were 0.66 (0.08) and 0.60 (0.10), respectively. In the Poisson regression, there were significant differences in systolic and diastolic blood pressures and heart rate between patients with and without awareness. CONCLUSIONS: A prediction indicating awareness by the network is very suggestive of true awareness and recall. Blood pressure and heart rate are significantly higher on average in patients with awareness than in patients without. In an individual patient, however, none of our artificial neural models can detect awareness sufficiently reliably.

Adult↗

Evaluation of intraoperative somatosensory-evoked potential monitoring during 100 cervical operations.

Continuous intraoperative somatosensory-evoked potential monitoring during scoliosis surgery, along with improved instrumentation techniques, has contributed to the reduction of neurologic injury from 4-6.9% to 0-0.7%. To assess whether somatosensory-evoked potential monitoring might play a similar role in cervical surgery, the authors compared the morbidity and mortality rates associated with 218 patients who were not monitored and were operated on between 1985-1989 with those found in 100 consecutive somatosensory-evoked potential monitored procedures done from 1989-1991. The cervical procedures were conducted for disc disease, stenosis, spondylosis, and ossification of the posterior longitudinal ligament. Eight of 218 unmonitored patients became quadriplegic (3.7%) and 1 died (0.5%); no instances of quadriplegia and no deaths were encountered among the 100 monitored patients. The reduction of neurologic deficit was attributed in part to early somatosensory-evoked potential detection of vascular or mechanical compromise of the spinal cord or nerve roots and to the immediate alteration of anesthetic or surgical technique in response to somatosensory-evoked potential changes, i.e., reversal of systemic or "relative" hypotension, adjustment of operative position, release of distraction, and cessation of manipulation. Continuous intraoperative somatosensory-evoked potential monitoring also was a practical tool in monitoring cervical surgery.

Cervical Vertebrae↗

Initial experience of peroperative electrocochleography monitoring in stapedectomy.

Clinical experience of intraoperative ECochG monitoring during stapes surgery is reported. Selected surgical phases have been taken into consideration, laying particular stress on the phase corresponding to the opening of the labyrinthine spaces. Compound action potential (CAP) amplitude and latency showed, a supposed, an inversely proportional relationship in most of the cases. Abnormal findings were also recorded in some patients, thus giving rise to different electrophysiological hypotheses. A proposal for an "in vivo" model for the study of the electrophysiological changes due to the opening of labyrinthine spaces is made.

Adult↗

Electrophysiological monitoring of neural functions during neurosurgery.

The intraoperative evoked potential monitoring has become indispensable in patients at risk for neurologic damages during surgery. This review presents the principal clinical indications for intraoperative monitoring of sensory and motor functions of spinal cord as well as of the auditory, facial and optic nerves and of brain functions during cerebrovascular surgery.

Cerebral Cortex↗

Effect of stimulus pulse duration on intraoperative somatosensory evoked potential (SEP) monitoring.

The effect of the stimulus duration on the amplitude and latency of intraoperative somatosensory evoked potential (SEP) was studied in 30 patients with idiopathic scoliosis undergoing surgery. Constant current square-wave electrical stimulation was applied to the posterior tibial nerve at a rate of 5.1 Hz. The effects of both the pulse duration and the stimulus current density on the intraoperative SEP were evaluated. Amplitudes and latencies of SEP were analyzed by one-way parametric analysis of variance. SEP signal recording was found to be difficult if the stimulus duration was less than 0.05 ms. The stimulus duration had no significant effect on the latencies of the SEP, but the amplitude of the SEP showed significant changes with differing stimulus durations. The SEP amplitudes were found with significant increases in pulse durations less than 0.3 ms. Stimulus pulse duration has a significant effect on SEP amplitude, and this should be taken into consideration during intraoperative SEP monitoring. A pulse duration of 0.3 ms is recommended for SEP using posterior tibial nerve stimulation.

Adolescent↗

Intraoperative somatosensory evoked potential monitoring predicts peripheral nerve injury during cardiac surgery.

BACKGROUND: Brachial plexus injury may occur without obvious cause in patients undergoing cardiac surgery. To determine whether such peripheral nerve injury can be predicted intraoperatively, we monitored somatosensory evoked potentials (SEPs) from bilateral median and ulnar nerves in 30 patients undergoing coronary artery bypass surgery. METHODS: SEPs were analyzed for changes during central venous cannulation and during use of the Favoloro and Canadian self-retaining sternal retractors, events hereto implicated in brachial plexus injury. Brachial plexus injury was evaluated during physical examination in the postoperative period by an individual blinded to results of SEP monitoring. RESULTS: Central venous cannulation was associated with transient changes in SEPs in four patients (13%). These changes occurred intermittently during insertion of the cannula but completely resolved within 5 min. Postoperative neurologic deficits did not occur in these cases. Use of the Canadian and Favoloro retractors was associated with significant changes in 21 patients (70%). In 16 of these, waveforms reverted toward baseline levels intraoperatively and were not associated with postoperative neurologic deficits. Five patients demonstrated a neurologic deficit postoperatively. In each of these, SEP change associated with use of surgical retractors persisted to the end of surgery compared to the immediate pre-bypass period. CONCLUSION: Intraoperative upper extremity SEPs may be used to predict peripheral nerve injury occurring during cardiac surgery.

Brachial Plexus↗

Spinal cord monitoring in scoliosis surgery using an epidural electrode. Results of a prospective, consecutive series of 191 cases.

STUDY DESIGN: Retrospective analysis of a prospectively accrued series of 191 consecutive patients who underwent intraoperative neurophysiologic monitoring during scoliosis corrective surgery. OBJECTIVES: To compare the monitoring outcome of idiopathic and neuromuscular scoliosis. To demonstrate the usefulness of the epidural electrode. To report sensitivity and specificity of the monitoring method employed at a single institution. SUMMARY OF BACKGROUND DATA: Reports in the literature emphasized the difficulty to obtain data in neuromuscular patients. Multimodality spinal cord monitoring has been recommended. Despite their still debated composition, neurogenic motor-evoked potentials have proven their validity in clinical practice. METHODS: Somatosensory and neurogenic evoked potentials were attempted in all patients presenting for scoliosis correction between 1999 and 2005. Study patients were divided into 3 groups: group 1, idiopathic; group 2, neuromuscular; and group 3, miscellaneous origins. RESULTS: The use of the epidural electrode demonstrated significant usefulness in the ability of monitoring otherwise nonmonitored patients, especially in group 2. Inability to obtain any evoked potentials occurred in 4 cases (2.1%). Five cases were found to be true positives. An adapted and rapid intervention permitted to avoid new postoperative deficit in all cases. There was no instance of false-negative data. The overall method sensitivity was 100%, and specificity was 52.69%. CONCLUSIONS: The use of a single epidural electrode allowing somatosensory evoked potentials recording and spinal cord stimulation alternately is a safe and valid method of intraoperative monitoring.

Adolescent↗

Pitfalls of intraoperative quick parathyroid hormone monitoring and gamma probe localization in surgery for primary hyperparathyroidism.

HYPOTHESIS: Intraoperative quick parathyroid hormone (qPTH) monitoring and gamma probe (GP) localization greatly aid the surgeon. DESIGN: Prospective case series of patients undergoing parathyroidectomy (PTX) with preoperative localization studies, operative data (including intraoperative qPTH values and GP localization), and outcomes. Follow-up was complete (mean, 4.2 months). SETTING: University teaching hospital. PATIENTS: We studied 57 consecutive patients with primary hyperparathyroidism from December 1, 1999, through November 30, 2000. Of these, 51 underwent first-time PTX, and 6, reoperative PTX (rePTX). MAIN OUTCOME MEASURES: Cure rate and morbidity after PTX or rePTX; sensitivity and accuracy of preoperative localization studies; prediction of cure from results of qPTH monitoring (comparing Nichols [>50% fall from the highest baseline level and lower than the lowest baseline] or normal-limit [>50% fall from first baseline level and lower than upper limit of the reference range] criteria); and value of GP localization. RESULTS: Patients were cured in 50 (98%) of 51 PTX and 6 (100%) of 6 rePTX for single adenomas (n = 49), double adenomas (n = 4), and multigland hyperplasia (n = 3). Nichols criteria for qPTH monitoring correctly categorized 45 (92%) of 49 cured single adenomas 10 minutes after excision. Only 35 (71%) of these adenomas were correctly categorized as cured by means of the normal-limit criteria. In double adenomas, both sets of criteria in the 10-minute samples indicated unresected glands in only 2 of 4 cases. Preoperative sestamibi parathyroid scans correctly localized 38 (76%) of 50 single adenomas. The GP was used in 54 of 57 cases. All adenomas measured greater than 20% of background ex vivo, but 6 thyroid nodules also measured greater than 20% ex vivo. In double adenomas, the GP helped locate the second adenoma in only 1 of 4 cases. The GP was graded as crucial in 2 cases with dense scar (both rePTX), helpful in 12 (22%) of 54 cases (particularly in retroesophageal glands), confirmatory in 32 (59%), and not helpful in 8 (15%). The GP helped localize 3 (43%) of 7 glands not seen on sestamibi parathyroid scans. CONCLUSIONS: Intraoperative qPTH monitoring confirmed cure in most cases. For single adenomas, use of the Nichols criteria for qPTH assessment allowed more accurate and faster confirmation than the normal-limit criteria. The GP was less useful but was crucial in 2 rePTX cases; it was not specific for parathyroid tissue. Both techniques have potential pitfalls that could result in surgical failure.

Adenoma↗

[Protocol of intraoperative neurophysiological spinal cord monitoring].

INTRODUCTION: The consequences derived from medullar harm caused during several spinal cord surgical interventions can often be catastrophic for the patient, even more taking into consideration that many of them are young. DEVELOPMENT: This problem is observed specially at interventions of spinal malformations (kyphoscoliosis), but also during other surgical techniques like fractures, degenerations, spinal tumors and aortic lesions. The use of somatosensory evoked potentials (SEP) began at late 70's, as a method to monitorize spinal cord function during surgery; years later, motor evoked potentials (MEP) joined this option, giving us direct information about the functioning of posterior spinothalamic tract (posterior column) and lateral corticospinal tract (pyramidal tract), respectively. This has motivated that, although the degree of surgical difficulty and complexity of spinal instrumentation have raised, the actual percentage of neurological complications derived from them has decreased. CONCLUSIONS: This article describes the intraoperative spinal cord monitoring protocol followed at Hospital Clínico San Carlos of Madrid, Spain, which includes the making of SEP and MEP, the latest according to the translaminar stimulation technique.

Evoked Potentials, Motor↗

Is intraoperative echocardiography a useful monitor in the operating room?

Few cardiac surgeons or anesthesiologists would argue with the view that intraoperative echocardiography, both transesophageal and epicardial, has become an important diagnostic tool. Specific diagnostic applications primarily involve valve reconstruction and replacement, as well as complex congenital heart disease repairs. Routine echocardiographic monitoring in cardiac operations is, however, controversial. Three specific modalities may benefit from this technology. Aortic root scanning before cannulation/proximal coronary anastomoses using surface echocardiography is one. Areas with significant atherosclerosis can be identified and manipulation avoided. Another is quantification of global left-ventricular function using transesophageal echocardiography. This method may have specific relevance to patients requiring mechanical circulatory assistance. Using echocardiography to monitor ischemic regional wall-motion abnormalities and using the findings to predict an unfavorable outcome is a third suggested use for perioperative monitoring in cardiac surgery.

Cardiac Surgical Procedures↗

Results of electroencephalographic monitoring during 369 consecutive carotid artery revascularizations.

A continuous intraoperative EEG monitoring was performed in 369 consecutive carotid artery revascularizations (CARs) (321 patients) to minimize the intraoperative neurological morbidity. There were 227 carotid endarterectomies and patch graft angioplasty (198 patients), 79 carotid eversion endarterectomies (70 patients) and 58 internal carotid artery reimplantations into the common carotid artery (48 patients). Indications for CARs were TIAs (141, 43.9%), amaurosis fugax (60, 18.6%) and fixed or partial nonprogressing stroke (14, 4.3%). One hundred and six patients (33.1%) were asymptomatic. EEG abnormalities consistent with cerebral ischemia occurred in 97 (26.3%) operations. The indwelling shunt (IS) was used in 73 cases; in the remaining 24 (24.7%), IS was not used on purpose because the surgical procedure was carried out successfully within 5-6 min after the appearance of EEG changes. All patients awoke from the anesthesia without any neurological deficit. Five patients presented with a major stroke within postoperative day 1 and 2, and 1 patient died on postoperative day 10. In 2 of these cases, the intraoperative EEG monitoring was absolutely normal and the IS was not used: the carotid occlusion was due to technical errors. The most striking finding of this series is the absence of false-negative results in continuous EEG monitoring. EEG monitoring appears an available and useful method for the detection of cerebral ischemia secondary to carotid cross-clamping and contributes to put at zero the intraoperative complications of the surgical procedure.

Adult↗

Evaluation of intraoperative nerve-monitoring during insertion of an iliosacral implant in an animal model.

BACKGROUND: The use of continuous electromyographic and somatosensory-evoked-potential monitoring systems has been advocated to assist in avoiding nerve-root injury during operations on the pelvic ring. More recently, it was suggested that stimulus-evoked electromyographic monitoring may further decrease the risk of iatrogenic nerve-root injury during posterior pelvic fixation by enabling the surgeon to determine the actual distance of an implant from a nerve root. The purpose of the current study was to evaluate the relative efficacy of these three methods of monitoring for minimizing the risk of neural injury during the placement of iliosacral implants. METHODS: While the function of the first sacral nerve root was monitored with the use of stimulus-evoked electromyographic, continuous electromyographic, and somatosensory-evoked-potential monitoring techniques, a 2.0-millimeter stainless-steel Kirschner wire was progressively inserted, guided by a high-speed computerized tomographic scanner, into the first sacral body of seventeen hemipelves in nine dogs. The end point was contact with the nerve as demonstrated by the computerized tomographic images. It was expected that this end point would be heralded by a burst of spontaneous electromyographic activity and an abnormal somatosensory-evoked-potential signal. Anatomical dissection at the completion of the study documented the final position of the Kirschner wire. RESULTS: Anatomical dissection demonstrated compression or penetration of the nerve root in sixteen of the seventeen specimens. A spontaneous burst of electromyographic activity was not recorded for any specimen on continuous electromyographic monitoring; this finding was significantly different from what had been expected (p<0.001). Because of technical problems, somatosensory evoked potentials could be recorded for only twelve hemipelves that had nerve-root compression or penetration, and abnormal somatosensory evoked potentials were recorded for only one of the twelve; this finding was significantly different from what had been expected (p<0.001). A total of 113 stimulus-evoked electromyographic data points were obtained. The correlation coefficient for the relationship between the current threshold recorded with stimulus-evoked electromyographic monitoring and the distance of the wire from the nerve was 0.801 (p<0.001). The actual measured current thresholds were of an observed proportion not different from what had been expected (p = 0.48). CONCLUSIONS: Continuous electromyographic and somatosensory-evoked-potential monitoring techniques failed to indicate contact with the nerve root reliably in this animal model. However, stimulus-evoked electromyographic monitoring consistently provided reliable information indicating the proximity of the implant to the nerve root.

Animals↗

[Prospective comparison of functional magnetic resonance imaging and intraoperative motor evoked potential monitoring for cortical mapping of primary motor areas].

OBJECTIVE: To compare the relation between the preoperative functional magnetic resonance imaging (fMRI) with blood oxygen level dependent (BOLD) technique and intraoperative motor evoked potential (MEP) monitoring for cortical mapping of primary motor cortex in patients with tumors near the central area. And to determine whether non-invasive preoperative fMRI can provide results equivalent to those achieved with the invasive neurosurgical "gold standard". METHODS: A prospective study of 16 patients with various pathological tumors of the central area was conducted. Preoperative fMRI scans using the BOLD contrast technique in each patient were performed. An activation scan was achieved by using a motor task paradigm, which consisted of simple flexion-extension finger movements and finger-to-thumb touching in a repeating pattern. The anatomical structure was delineated by the T(1)-weighted three-dimensional fast spoiled gradient recalled sequence (3D/FSPGR) immediately afterward. The BOLD images were overlaid on the T(1)-weighted 3D/FSPGR images, and then co-registered to the neuronavigation system. The fMRI activations were documented by using a neuronavigation system in sequence, and compared to standardized intraoperative MEP monitoring, which included direct cortical electrical stimulation (DCES) or transcranial cortical electrical stimulation (TCES) or their combination. The compound muscle action potentials of forearm flexor and hand muscle responses were recorded during either TCES or DCES. Two techniques were compared to determine the accuracy for cortical mapping of primary motor areas with fMRI. RESULTS: Overall, the intraoperative MEP monitoring showed good correlation with fMRI activation in 92.3% of cases. The coincidence rate, however, was 100.0% between TCES and fMRI, and 66.7% between DCES and fMRI respectively. There was no statistically difference between two cortical mapping techniques, chi-square test of paired comparison of enumeration data, P < 0.01. CONCLUSION: BOLD fMRI was a high sensitive and reliable technique to locate the position of the primary motor areas and their spatial relation with adjacent tumor, especially for the presurgical planning in patients with central area brain tumor.

Adolescent↗

Time-dependent changes in median nerve sensory amplitude after local anesthetic administration and tourniquet application.

Indirect visualization, as used in several newer mini-open and endoscopic carpal tunnel release (CTR) procedures, may increase the possibility of nerve injury in some cases. Intraoperative neural monitoring may be used to evaluate nerve location and integrity. In the study reported here, we assessed the feasibility of intraoperative neural monitoring by systematically exploring the effect of local anesthetic and tourniquet on median sensory amplitude. Results for 30 median nerves (7 symptomatic) showed that sensory amplitude decreased, on average, 54% with lidocaine injection, 15% with tourniquet application, and 47% with the combination. Sensory amplitudes of 9 of 10 nerves were still above 1.0 microV 15 minutes after anesthetic administration and tourniquet application. Study results demonstrate that intraoperative monitoring, using the amplitude of the median sensory nerve response, is viable under CTR conditions.

Action Potentials↗

Proximal segment positioning in bilateral sagittal split osteotomy: intraoperative dynamic positioning and monitoring by sonography.

PURPOSE: Most methods of condylar positioning merely maintain the preoperative condyle-fossa relationship and therefore produce similar prevalences of postoperative dysfunction. This study evaluates dynamic proximal segment positioning by intraoperative sonography versus the splint and plate technique discussed in a previous issue. PATIENTS AND METHODS: Condylar positioning was monitored by sonography alone in 30 bimaxillary operated patients (14 Angle Class II, 16 Class III), the control group had a splint and plate positioning in 23 patients (9 Angle Class II, 14 Class III). The clinical dysfunction index, prevalence of condylar translation, and disc dislocation were compared preoperatively and at 1, 6, and 12 months postoperatively. RESULTS: The postoperative range of motion did not disclose statistically significant differences between study and control group (Pearson's proportionality index r = 0.78, 2-way analysis of variance: P <.4, F = 4.4, alpha =.05 significance level). Sonographic placement allowed dynamic intraoperative monitoring of the condylar position and required an average of 5 minutes compared with 25 minutes for conventional positioning. Postoperative dysfunction prevalence was reduced 89% for Class II and 100% in Class III in the study group versus 50% for Class II and 100% for Class III in the control group (r = 0.45, P <.3, F = 9.3). Prevalence of disc dislocation was reduced 76% in Class II and 80% in Class III patients in the study group and 50% of Class II and 100% of Class III in the control group (r = 0.7, P <.48, F = 9.2). CONCLUSIONS: Comparable postoperative reduction of condylar translation and recovery, dysfunction, and disc dislocation was seen with use of both methods in a 1-year follow-up. The new technique allowed intraoperative real-time monitoring and dynamic correction and was safe, easier, and faster than conventional plate positioning.

Adolescent↗