PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94Linked to original sources

Reduction of arteriosclerotic nanoplaque formation and size by fluvastatin in a receptor-based biosensor model.

Proteoheparan sulfate can be adsorbed onto a methylated silica surface in a monomolecular layer via its transmembrane hydrophobic protein core domain. Due to electrostatic repulsion, its anionic glycosaminoglycan side chains are stretched out into the blood substitute solution, thereby representing a receptor site for specific lipoprotein binding through basic amino acid-rich residues within their apolipoproteins. The binding process was studied by ellipsometric techniques suggesting that HDL has a high binding affinity and a protective effect on interfacial heparan sulfate proteoglycan layers with respect to LDL and Ca(2+) complexation. LDL was found to be deposited strongly at the proteoheparan sulfate-coated surface, particularly in the presence of Ca(2+), apparently through complex formation 'proteoglycan-low density lipoprotein-calcium'. This ternary complex build-up may be interpreted as arteriosclerotic nanoplaque formation on the molecular level responsible for the arteriosclerotic primary lesion. In a receptor-based biosensor application, this system was tested on its reliability to unveil possible acute pleiotropic effects of the lipid lowering drug fluvastatin. The VLDL/IDL/LDL and VLDL/IDL/LDL/HDL plasma fractions from a high risk patient with dyslipoproteinaemia and type 2 diabetes mellitus showed the start of arteriosclerotic nanoplaque formation at a normal blood Ca(2+) concentration, with a strong increase at higher Ca(2+) concentrations. Nanoplaque formation and size of the HDL-containing lipid fraction remained well below that of the LDL-containing lipid fraction. Fluvastatin, whether applied acutely to the patient (one single 80 mg slow release matrix tablet) or in a 2-month medication regimen, markedly slowed down this process of ternary aggregational nanoplaque build-up and substantially inhibited nanoplaque size development at all Ca(2+) concentrations used. The acute action gave no significant change in lipid concentrations of the patient. Furthermore, after nanoplaque generation, fluvastatin, similar to HDL, was able to reduce nanoplaque formation and size. These immediate effects of fluvastatin have to be taken into consideration when interpreting the clinical outcome of long-term studies.

Adsorption↗

Detection of human apolipoprotein E genotypes by DNA biosensors coupled with PCR.

Apolipoprotein E (apoE) is an important constituent of several plasma lipoproteins and has been associated with the risk of developing cardiovascular diseases and in familiar type III hyperlipoproteinemia. We developed new procedures for the detection of apolipoprotein E polymorphism in human blood based on coupling DNA electrochemical or piezoelectric sensors with polymerase chain reaction (PCR). The electrochemical sensor was obtained by immobilizing single-stranded oligonucleotides onto graphite screen-printed electrodes by adsorption at controlled potential. The hybridization reaction that occurred on the electrode surface was evidenced by chronopotentiometric stripping analysis-using daunomycin as indicator. In the piezoelectric sensor, biotinylated 23-mer probes were immobilized on the streptavidin-coated gold surface of a quartz crystal; streptavidin was covalently bound to the thiol/dextran modified gold surface. The hybridization of the immobilized probes with complementary and mismatched DNA was investigated. With the use of two different probes, it was possible to investigate both positions in which apoE polymorphism takes place and consequently, to distinguish the different genotypes. The procedure was validated with both kinds of biosensor with a reference method based on polyacrilamide gel electrophoresis.

Apolipoproteins E↗

Analysis of the fine specificity of Tn-binding proteins using synthetic glycopeptide epitopes and a biosensor based on surface plasmon resonance spectroscopy.

Using synthetic Tn (GalNAc-O-Ser/Thr) glycopeptide models and a biosensor based on surface plasmon resonance spectroscopy we have determined that isolectin B4 from Vicia villosa (VVLB4) binds to one Tn determinant whereas the anti-Tn monoclonal antibodies 83D4 and MLS128 require at least two Tn residues for recognition. When an unglycosylated amino acid is introduced between the Tn residues, both antibodies do not bind. MLS128 affinity was higher on a glycopeptide with three consecutive Tn residues. These results indicate that Tn residues organized in clusters are essential for the binding of these antibodies and indicate a different Tn recognition pattern for VVLB4.

Animals↗

Effect of receptor phosphorylation on the binding between IRS-1 and IGF-1R as revealed by surface plasmon resonance biosensor.

A receptor binding assay based on the surface plasmon resonance (SPR) biosensor technique was developed to study the interaction between insulin-like growth factor-1 receptor (IGF-1R) and its intracellular substrate protein insulin receptor substrate-1 (IRS-1). The sensor surface was modified with anti-IGF-1R (alpha-subunit) monoclonal antibodies for the capturing of the receptor-containing membrane fragments from cell lysates. The IGF-1R was successfully immobilized on the sensor surface with binding capability for its intracellular substrates. SPR measurements showed that the tyrosine phosphorylation of IGF-1R induced by its extracellular ligand insulin-like growth factor-1 caused the receptor to bind with IRS-1 10 times faster than the unactivated receptor. As a result, the affinity constants of IRS-1 to phosphorylated and unphosphorylated IGF-1R were (8.06+/-5.18)x10(9) M(-1) and (9.81+/-4.61)x10(8) M(-1), respectively.

3T3 Cells↗

Measurement of cytoplasmic copper, silver, and gold with a lux biosensor shows copper and silver, but not gold, efflux by the CopA ATPase of Escherichia coli.

Copper, silver, gold and other heavy metals are potentially toxic to cells. Copper is also essential and cellular levels must be carefully controlled. In contrast, there is no known biological role for silver or gold and they have not been recognized as metals that are under homeostatic control. Using a luminescent biosensor based of the Vibrio fischeri lux gene cluster under the control of the Escherichia coli copA promoter/CueR metal-responsive regulator, we could show that in E. coli, cytoplasmic copper and silver, but not gold, are regulated by the CopA ATPase, the major copper efflux pump.

Adenosine Triphosphatases↗

Biosensors.

This review introduces biosensors as analytical devices that respond selectively to analytes in appropriate samples and convert their concentrations into electrical signals via a combination of a biological recognition system and a suitable transducer. The last decade has seen dramatic advances in the design of sensor configurations, the marriage of biological systems with modern monolithic silicon and optical technologies, the development of effective electron-exchange systems and the introduction of direct immunosensors.

Animals↗

Analysis of the interaction between monoclonal antibodies and human hemoglobin (native and cross-linked) using a surface plasmon resonance (SPR) biosensor.

To develop a stable immuno-assay system for quantification of human hemoglobin (Hb), the interaction between various antibodies and Hb was studied using a surface plasmon resonance (SPR) biosensor in the BIAcore equipment (Amersham Pharmacia Biotech) with an immobilized anti-Hb antibody sensor chip. When polyclonal antibodies were used, the immuno-reactivity of purified and commercially available Hb decreased drastically with incubation times up to 14 h. This instability of immuno-reactivity of Hb is attributable to the conformational changes in Hb induced by oxidation. On the other hand, of the sixteen monoclonal antibodies tested, four antibodies (MSU-102, -103, -106 and -115) were found to maintain their immuno-reactivities at least up to 24 h. During long-term storage, however, the immuno-reactivity of Hb with these monoclonal antibodies decreased significantly. The chemical betabeta-cross-linking of Hb was effectively able to stabilize the structure of Hb and immuno-reactivity with monoclonal antibodies such as MSU-103 for periods at least up to 70 days. Therefore, the combination of specific monoclonal antibodies such as MSU-103 and a betabeta-cross-linked Hb standard could be used for the quantification of Hb.

Antibodies, Monoclonal↗

Assessment of synthetic peptides for hepatitis A diagnosis using biosensor technology.

In the present work we demonstrate the application of a commercial biosensor instrument (BIACORE 1000, Biacore AB, Uppsala) for the detection of antibodies against the hepatitis A virus (HAV) in human serum samples using linear and branched synthetic peptides related to the VP3 capsid protein of HAV. We also studied the conformation of the synthetic peptides by circular dichroism (CD) in order to analyse the changes in secondary structure of the constructs that could influence their recognition by antibodies. Linear and dimeric VP3(110-121) multiple antigen peptides (MAP) were the most sensitive and appropriate for serological studies of serum from HAV infected patients using BIACORE. Immobilization of tetrameric MAPs via amine groups apparently failed to preserve the active conformation of the peptide epitope since it led to lower antibody binding compared to linear and dimeric peptides. The CD analysis showed that the tetrameric MAP constructs tend to adopt a beta-sheet structure due to intermolecular aggregation, which limits epitope accessibility. Our results demonstrate the value of biospecific interaction analysis technology using synthetic peptides for the diagnosis of acute hepatitis A.

Amino Acid Sequence↗

Development and validation of a biosensor-based immunoassay for progesterone in bovine milk.

We have developed a rapid automated immunoassay, using the BIACORE surface plasmon resonance (SPR) biosensor, to measure progesterone in bovine milk. The assay was designed as an inhibition assay with progesterone covalently immobilised to the carboxymethyl dextran matrix of a CM5 sensor chip. A fixed amount of monoclonal anti-progesterone antibody 39C5H7 was mixed 9:1 with the sample and the amount of free antibody was then determined using biomolecular interaction analysis (BIA) by injection of the mixture over the immobilised progesterone sensor surface. The assay was designed to cover the concentration range 0.5 to 50 ng/ml. The limit of detection (LOD) was 3.56 ng/ml. Reproducibility of the assay was very good with both intra-assay and inter-assay coefficients of variation <5%. As results become available within minutes of injection and the procedure involves fully automated instrumentation, we believe that this BIA assay for progesterone in milk could be used in-line in the milking parlour and, thus, provide an important tool for reproductive management of dairy cattle to detect heat and predict pregnancy.

Animals↗

Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor.

The performance of the fluorescent dye Alexa Fluor 647 (AF647) was explored as an alternative to Cy5 for immunoassays on the RAPTOR, a fiber optic biosensor. The RAPTOR performs sandwich fluoroimmunoassays on the surface of small polystyrene optical waveguides for analyte detection. Fluorescence and immunoassay data were examined at various dye-to-protein (D/P) ratios for both Cy5 and Alexa Fluor 647. Primarily, due to the self-quenching characteristics of Cy5, Alexa Fluor 647 is substantially more effective in fluoroimmunoassays, yielding over twice the signal for any given analyte concentration. Alexa Fluor 647 can be attached to antibodies at higher ratios, D/P=6, before self-quenching begins to limit the dye's effectiveness. Furthermore, while Alexa Fluor 647 becomes quenched at high dye-to-protein ratios, D/P=9, the net fluorescence yield reaches a maximum, as opposed to Cy5-labeled proteins, which become nearly nonfluorescent at high labeling ratios, D/P> or =6. The limitations of Cy5 were elucidated with an immunoassay for ricin, while the advantages of Alexa Fluor 647 were demonstrated in both direct binding assays as well as in a sandwich immunoassay for staphylococcal enterotoxin B.

Antibodies↗

Kinetic analysis of interactions between bispecific monoclonal antibodies and immobilized antigens using a resonant mirror biosensor.

A resonant mirror biosensor (IAsys) protocol is described for the comparative kinetic analysis of the ability of monoclonal antibodies (Mabs) and bispecific antibodies (Babs) to bind immobilized antigens. The protocol has been optimized and validated using the panel of affinity-purified antibodies, including two parental Mabs, one specific to human immunoglobulin G (hIgG) and another specific to horseradish peroxidase (HRP), and a Bab derived thereof by cell fusion (anti-hIgG/HRP Bab). The real-time kinetic analysis of antigen-antibody interactions using this protocol allows to demonstrate the differences in the avidity of bivalently binding Mabs and monovalent Babs. As shown in our previous study [J. Immunol. Methods 261 (2002) 103], the observed equilibrium association constants (Kass) determined by IAsys using this protocol yield figures almost overlapping with those obtained by solid-phase radioimmunoassay (RIA). The described protocol is suited for the investigation of the effects of valency on the binding properties of antibodies. It also may be applied for the selection of Mabs and Babs with desired features, for different fields of application.

Animals↗

Biosensors for marine pollution research, monitoring and control.

Measurement of ecological, climatic and anthropogenic changes underpins the formulation of effective management strategies for sustainable use and protection of the marine environment. Sensors are traditionally used in marine studies to determine physical parameters, but there is increasing demand for real-time information about chemical and biological parameters. These parameters are currently measured in samples collected at sea and subsequently analysed in the laboratory. Biosensors fuse the exquisite sensitivity and specificity of living systems with the processing power of microelectronics to deliver simple, inexpensive measurement systems for use in the field or deployment in situ. While their potential for use in the marine environment is enormous, much published work to date has focussed on applications in freshwater and wastewater. Marine applications pose a substantial challenge in the robustness required for remote application, but recent developments in portable medical devices and receptor design suggest that these demands can now be realistically tackled.

Animals↗

An algal biosensor for the monitoring of water toxicity in estuarine environments.

An algal biosensor for toxicity assessment of estuarine waters is proposed. The sensor was obtained by coupling a suited algal bioreceptor (the cyanobacterium Spirulina subsalsa) to an amperometric gas diffusion electrode. The analytical device allows the monitoring of the evolution of photosynthetic O2 and the detection of alterations due to toxic effects caused by environmental pollutants present in the medium. Four chemical species representative of three main different classes of pollutants (heavy metals, triazinic herbicides, carbamate insecticides) were tested at different concentrations using a standardized natural water as experimental medium. In all the cases a toxic response was detected (i.e. a dose-related inhibition of photosynthetic activity was recorded) with good reproducibility.

Bacterial Proteins↗

Methane microprofiles in a sewage biofilm determined with a microscale biosensor.

Microprofiles of the methane concentration in a 3.5-mm-thick sewage outlet biofilm were measured at high spatial and temporal resolution using a microscale biosensor for methane. In the freshly collected biofilm, methane was building up to a concentration of 175 mumol l-1 at 3 mm depth with a total methanogenesis of 0.14 mumol m-2 s-1, as compared to an aerobic respiration (including methane oxidation) of 0.80 mumol m-2 s-1. A model biofilm was established by homogenisation of an in situ biofilm and 12 days of incubation with surplus sodium acetate. The homogenised biofilm was able to maintain 50% of the methanogenic activity in the absence of external electron donor. Oxygen had only a minor effect on the methane production, but aerobic respiration consumed a substantial part of the produced methane and was thus an important control on methane export from the biofilm. A concentration of 2 mmol l-1 nitrate was shown to inhibit methanogenesis only in the upper layer of the biofilm, whereas a further addition of 2 mmol l-1 sulphate inhibited methanogenesis in the entire biofilm. The study demonstrated the power of the methane microsensor in the study of microhabitats with concurrent production and consumption of methane.

Bacteria↗

The use of the mitochondrial transmembrane electric potential as an effective biosensor in ecotoxicological research.

In this work, the mitochondrial transmembrane electric potential (delta psi) of isolated mitochondria was used to evaluate the toxicity of some chemicals (endosulfan, 3,4-dichloroaniline, parathion, tributyltin and cadmium) and wastewater. Mitochondria were isolated from rat liver, and the delta psi measured in a suitable assay medium, using a sensitive tetraphenylphosphonium (TPP+) electrode. The test substance was pre-incubated in a rotenone-containing medium during 3 min with 1.0 mg of mitochondrial protein. Mitochondria were energised with succinate and after the establishment of a constant maximal potential ADP was added to induce the phosphorylative cycle. Chosen endpoints were the membrane potential from mitochondria oxidising succinate and the depolarisation induced by ADP. After the appropriate transformations the EC50 (effective concentration) was calculated for each toxicant. Even very low concentrations of a toxicant were able to affect the delta psi, thus showing its suitability as a biosensor in ecotoxicology and results were reproducible between tests. The utilisation of delta psi in screening tests of pure substances and wastewater seems to be very effective and can be carried out routinely.

Aniline Compounds↗

Analysis of microbial communities with electrochemical microsensors and microscale biosensors.

Electrochemical microsensors for O2, pH, H2S, H2, and N2O are now available commercially, thus it has become a relatively simple task to analyze the microenvironment in stratified microbial communities for several chemical species. In addition, sensors are available for the physical parameters diffusivity and flow, and based on knowledge about both transport processes and microdistribution of chemistry, it becomes possible to calculate the spatial distribution and local rates of transformations, such as aerobic respiration or denitrification. As compared to other advanced techniques, microsensor equipment is inexpensive. For example, it is possible to start working with oxygen microsensors with an investment of only about 5000 dollars. Construction of one's own microsensors is only recommended for the very dedicated user, but the investment here is mainly in terms of man-hours as the equipment is simple and inexpensive. By establishing a microsensor construction facility, it is possible to work with short-lived sensors such as ion-selective microsensors for H+, NO2(-), NO3(-), Ca2+, and CO3(-) based on ion exchangers and with microscale biosensors for NO(x)-, NO2(-), CH4, and volatile fatty acids based on immobilized bacteria.

Bacteria↗

Issues underlying use of biosensors to measure metal bioavailability.

Heavy metal-mediated toxicity in the environment is dependent on bioavailable metal concentrations both internal and external to microbial cells. Both internal and external metal bioavailability are influenced by multiple factors in the soil environment. External factors include pH, redox potential, ionic strength, organic matter and clay content. The internal bioavailable metal concentration is dependent on both the aforementioned external factors, as well as metal uptake and efflux activities that are specific for each microorganism. The metal-specific biosensors discussed in this article can be used to measure internal metal bioavailability.

Biological Assay↗

Revelation of ternary complexes between redox partners in cytochrome P450-containing monooxygenase systems by the optical biosensor method.

Formation of binary and ternary complexes in the water-soluble cytochrome P450cam (P450cam)-containing as well as in the membrane P4502B4(2B4)- and the mixed P450scc-containing monooxygenase systems was investigated in real time by the 'resonant mirror' optical biosensor method. It was shown that the inter-protein electron transfer occurs not only during complex formation but also upon random collision--as was the case with the d-Fp/d-b5 pair (2B4 system). Binary complexes may be either facilitative to electron transfer (electron-transfer complexes) or prohibitive to it (non-productive complexes). Although the binary PdR/Pd and P450cam/Pd complex formation (within the P450cam-system) as well as the binary AdR/Ad and P450scc/Ad complex formation (within the P450scc-system) does occur, the lifetimes of these complexes formed are several orders of magnitude higher than the time required for realization of a complete hydroxylation cycle. At the same time, the lifetimes of the ternary PdR/Pd/P450cam and AdR/Ad/P450scc complexes are sufficient to permit the realization of a complete hydroxylation cycle in either of these systems. For the membrane P450 2B4 system, the formation of both the binary (Fp/2B4 and 2B4/b5) and ternary (Fp/2B4/b5) complexes was registered. The lifetimes of the binary Fp/2B4 and the ternary Fp/2B4/b5 complexes are sufficient for realization of a complete hydroxylation cycle in each of them.

Biosensing Techniques↗