PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

Monitoring strategies at phreatic wellfields: a 3D travel time approach.

Ground water quality networks for monitoring phreatic drinking water wellfields are generally established for two main purposes: (1) the short-term safeguarding of public water supply and (2) signaling and predicting future quality changes in the extracted ground water. Six monitoring configurations with different well locations and different screen depths and lengths were evaluated using a numerical model of the 3D ground water flow toward a partially penetrating pumping well in a phreatic aquifer. Travel times and breakthrough curves for observation and pumping wells were used to judge the effectiveness of different design configurations for three monitoring objectives: (1) early warning; (2) prediction of future quality changes; and (3) evaluation of protection measures inside a protection zone. Effectiveness was tested for scenarios with advective transport, first-order degradation, and linear sorption. It is shown that the location and especially the depth of the observation wells should be carefully chosen, taking into account the residence time from the surface to the observation well, the residual transit times to the extraction well, and the transformation and retardation rates. Shallow monitoring was most functional for a variety of objectives and conditions. The larger the degradation rates or retardation, the shallower should the monitoring be for effective early warning and prediction of future ground water quality. The general approach followed in the current study is applicable for many geohydrological situations, tuning specific monitoring objectives with residence times and residual transit times obtained from a site-specific ground water flow model.

Environmental Monitoring↗

Developing a long-term monitoring network under uncertain flowpaths.

A long-term monitoring well network is developed using complementary and simple approaches in conjunction with a stochastic ground water flow and transport model. The development is illustrated for a case study of a U.S. nuclear testing site (Shoal) that is undergoing environmental restoration. The network design builds on three different, yet complementary, tools for locating the monitoring wells with a main objective of detection monitoring. The first tool is applied to select potential siting horizons where monitoring wells could be located. The second tool is used to place monitoring wells in locations with high success probability. The success here is defined as the detection of migrating stochastic plumes before a certain mass percentage reaches a compliance boundary. The third tool is used to analyze detection efficiency of multiple combinations of three wells. Seventy-six different three-well networks are selected from 20 candidate locations and are evaluated for detection efficiency. From the 76 networks analyzed, 28 attain detection efficiency close to or above 70%. The results of the different analyses provide multiple alternatives for the locations of the three wells, which will become part of the long-term monitoring network at Shoal. A number of combinations are equally good, and the final choice will depend on practical considerations and future agreements between model sponsor and regulators.

Environmental Monitoring↗

Vascular access quality monitoring.

Access dysfunction presents a risk for haemodialysis patients and is costly for health care providers. Regular vascular access quality (VAQ) monitoring enables the detection of adverse access conditions early allowing timely interventions, which will presumably be less invasive, more successful and cheaper. This paper reviews all currently used assessment parameters: dynamic and static pressures, recirculation and blood flow through the access--and analyses pros and cons of each of them. Based on this overview it is concluded that access flow monitoring should be the method of choice, possibly combined with monitoring of another parameter to further enlarge diagnostic possibilities of the monitoring. The VAQ monitoring system developed and used currently in the author's dialysis centre is briefly described as an example. The issue of access flow related to haemodynamics is briefly mentioned. With the introduction of any VAQ monitoring system, one has to acknowledge a change in structure of interventions and that the demand for surgical procedures decreases with a concurrent increase in percutaneous interventions.

Arteriovenous Shunt, Surgical↗

On the need for monitor unit calculations as part of a beam commissioning methodology for a radiation treatment planning system.

This paper illustrates the need for validating the calculation of monitor units as part of the process of commissioning a photon beam model in a radiation treatment planning system. Examples are provided in which this validation identified subtle errors, either in the dose model or in the implementation of the dose algorithm. These errors would not have been detected if the commissioning process only compared relative dose distributions. A set of beam configurations, with varying field sizes, source-to-skin distances, wedges, and blocking, were established to validate monitor unit calculations for two different beam models in two different radiation treatment planning systems. Monitor units calculated using the treatment planning systems were compared with monitor units calculated from point dose calculations from tissue-maximum ratio (TMR) tables. When discrepancies occurred, the dose models and the code were analyzed to identify the causes of the discrepancies. Discrepancies in monitor unit calculations were both significant (up to 5%) and systematic. Analysis of the dose computation software found: (1) a coordinate system transformation error, (2) mishandling of dose-spread arrays, (3) differences between dose calculations in the commissioning software and the planning software, and (4) shortcomings in modeling of head scatter. Corrections were made in the beam calculation software or in the data sets to overcome these discrepancies. Consequently, we recommend incorporating validation of monitor unit calculations as part of a photon beam commissioning process.

Algorithms↗

Polysomnography and home documented monitoring of cardiorespiratory pattern.

Polysomnographic findings were compared with data obtained subsequently from home documented monitoring in order to study the diagnostic value of both techniques. Polysomnography was performed in 1274 infants born prematurely and in 422 patients admitted because of apparent life threatening events (ALTEs). In 72 of the infants, home documented monitoring of the cardiorespiratory pattern, including QRS complexes, was performed. Subsequent documented episodes of heart rate < 50 beats/min were considered as "serious life threatening events". It was confirmed that polysomnographic findings correlated well with subsequent events as registered by home documented monitoring. Especially in the ALTE group where both infants with and without abnormal polysomnography were home monitored, the single polysomnography significantly predicted subsequent life threatening events. Home documented monitoring of the cardiorespiratory pattern has a distinctive advantage over simple cardiorespiratory monitoring as a means to identify and document life threatening events, in addition to its value as a rescue device.

Apnea↗

Efficacy of perceptual versus heart rate monitoring in the development of endurance.

The purpose of this investigation was to compare the effectiveness of using ratings of perceived exertion (RPE) with heart rate in the monitoring of exercise intensity during aerobic dance instruction. Thirty-eight students who enrolled in aerobic dance classes used heart rate to monitor exercise intensity while 38 additional students used RPE to monitor exercise intensity during a 14-week course. Classes met twice a week for 50 min and all outside workouts were recorded. The groups did not differ with respect to the number of outside workouts. The dependent variable was endurance performance as measured by the distance run in 15 min. Data were analysed with a repeated measures analysis of variance (ANOVA) for multifactor experiments. There were significant trials (P less than 0.0001) and interaction (P less than 0.05) effects, and both groups improved significantly in endurance performance during 14 weeks of training. However, the group using RPE to monitor exercise intensity had a significantly greater gain in endurance. The heart rate group had a mean increase of 6% (166 m) whereas the RPE group increased 11% (274 m). It is concluded that during aerobic dance the monitoring of exercise intensity with RPE is associated with greater improvement in endurance than is heart rate monitoring.

Adult↗

Value of routine cardiac monitoring in the management of acute myocardial infarction outside a coronary care unit.

In a coronary care unit patients and electrocardiographic monitors are under almost continuous observation by trained personnel. This paper suggests that in a general medical ward without this facility routine cardiac monitoring with E.C.G. oscilloscopes is unlikely to lower the overall mortality from acute myocardial infarction. A mortality of 25% for acute myocardial infarction was the same for a hospital without a coronary care unit where monitoring was routinely performed and for two neighbouring hospitals which did not routinely use monitoring during the period of analysis.The need to train personnel in the recognition of E.C.G. monitor tracings and the difficulties associated with monitor alarm systems are emphasized.

Arrhythmias, Cardiac↗

Randomised controlled trial of intrapartum fetal heart rate monitoring.

OBJECTIVE: To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. DESIGN: Prospective randomised controlled trial. SETTING: Referral maternity hospital, Harare, Zimbabwe. SUBJECTS: 1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. INTERVENTIONS: Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. MAIN OUTCOME MEASURES: Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. RESULTS: Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. CONCLUSIONS: Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources.

Female↗

Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database.

OBJECTIVES: To investigate patterns of self monitoring of blood glucose concentration in diabetic patients who use insulin and to determine whether frequency of self monitoring is related to glycaemic control. SETTING: Diabetes database, Tayside, Scotland. SUBJECTS: Patients resident in Tayside in 1993-5 who were using insulin and were registered on the database and diagnosed with insulin dependent (type 1) or non-insulin dependent (type 2) diabetes before 1993. MAIN OUTCOME MEASURES: Number of glucose monitoring reagent strips dispensed (reagent strip uptake) derived from records of prescriptions. First recorded haemoglobin A1c concentration in the study period, and reagent strips dispensed in the previous 6 months. RESULTS: Among 807 patients with type 1 diabetes, 128 (16%) did not redeem any prescriptions for glucose monitoring reagent strips in the 3 year study period. Only 161 (20%) redeemed prescriptions for enough reagent strips to test glucose daily. The corresponding figures for the 790 patients with type 2 diabetes who used insulin were 162 (21%; no strips) and 131 (17%; daily tests). Reagent strip uptake was influenced both by age and by deprivation category. There was a direct relation between uptake and glycaemic control for 258 patients (with recorded haemoglobin A1c concentrations) with type 1 diabetes. In a linear regression model the decrease in haemoglobin A1c concentration for every extra 180 reagent strips dispensed was 0.7%. For the 290 patients with type 2 diabetes who used insulin there was no such relation. CONCLUSIONS: Self monitoring of blood glucose concentration is associated with improved glycaemic control in patients with type 1 diabetes. Regular self monitoring in patients with type 1 and type 2 diabetes is uncommon.

Age Factors↗

Measuring the costs and benefits of heart disease monitoring.

OBJECTIVE: To evaluate the costs and benefits of alternative systems of coronary heart disease monitoring in Scotland. DESIGN: An option appraisal was conducted to evaluate the costs and benefits of implementing a coronary heart disease monitoring system. This involved a review of existing Scottish datasets and relevant reports, specification of options, definition and weighting of benefit criteria by key stakeholders, assessment of options by experts, and costing of options. The options were assessed by 33 stakeholders (grouped as cardiologists, patient representatives, general practitioners, public health physicians, and policy makers), plus 13 topic experts. SETTING: Scotland (population 5.1 million). RESULTS: Between group mean benefit weights were: mortality rates and case fatality (10.6), quality of life (9.8), patient function (8.8), hospital activity (7.8), primary care activity (9.25), prescribing (5.72), socioeconomic impact (4.0), risk factors (7.4), prevalence (5.0), incidence (6.0), case registration (6.82), international comparability (4.2), breadth of coverage (8.8), and frequency (5.8). Differences between group weights were significant for prevalence (p = 0.048) and international comparability (p = 0.032). Four monitoring options were identified: a community epidemiology model, based on MONICA (monitoring trends and determinants in cardiovascular disease) study methodology applied to a series of eight representative communities, had the highest benefits, at an average annual discounted cost of approximately pound 360,000; models based on the Australian cardiovascular disease monitoring scheme and on enhanced routine data offered fewer benefits at discounted average annual costs ranging from pound 165,000 to pound 195,000; finally, a coronary heart disease registry modelled on the Scottish Cancer Registry scheme would have had fewer benefits and substantially higher costs than the other options. CONCLUSIONS: The most beneficial coronary heart disease monitoring system is the community epidemiology model, based on MONICA methodology. Option appraisal potentially offers an explicit and transparent methodology for evidence based policy development.

Coronary Disease↗

Monitoring participant safety in phase I and II interventional trials: options and controversies.

BACKGROUND: The need for phase I and II clinical trials to have a data and safety monitoring plan (DSMP) is widely accepted; however, whether and/or when these trials should also have oversight by a data and safety monitoring board (DSMB) is controversial. Monitoring requirements also depend on whether the study is funded by the National Institutes of Health, funded and/or monitored by the US Food and Drug Administration (FDA), or funded by industry. However, there is little guidance about when and how to constitute a DSMB for phase I and II clinical trials. OBJECTIVES: The objectives of this article are to suggest guidelines for when and how to constitute a DSMB for phase I and II studies and to highlight the similarities and differences between DSMBs monitoring phase I and II versus phase III clinical studies. We highlight the utility of these guidelines in the safety monitoring of a mechanism of disease-based study of inhaled nitric oxide for acute vaso-occlusive crisis in pediatric patients with sickle cell disease that was funded and regulated by the FDA. CONCLUSION: The goal of DSMPs regardless of the phase of the clinical trial is to protect participant safety and ensure the integrity and validity of the data. A DSMB can ensure that risks and data are evaluated in a timely, efficient, and unbiased manner. We describe "risk-based" guidelines to determine situations in which a DSMB may be an appropriate addition to a DSMP for phase I and II clinical trials. We also address the roles and responsibilities of the DSMB for these studies.

Anemia, Sickle Cell↗

Diagnostic accuracy of ambulatory ECG monitoring in ischemic heart disease.

Fifty patients with precordial pain were evaluated by 24 hour ambulatory ECG monitoring during normal everyday activities, and by coronary arteriography. The monitoring was regarded as positive if deviation of the ST segment of 1 mm or more from the resting pattern was observed, or if major T wave inversion occurred. Comparison of the results of the two tests showed a good correlation. Among the 32 patients with positive abnormalities on ECG monitoring, 28 had severe coronary disease (greater than 60% obstruction). Among the 18 patients with negative monitoring, only three had severe coronary disease. All seven patients with major T inversion had significant coronary obstruction. The type of chest pain and the resting ECG were less indicative of coronary pathology. The good correlation demonstrated between the ambulatory ECG monitoring and coronary arteriograms validates the monitoring as a reliable tool for uncovering latent ischemic heart disease (IHD) and for evaluation of patients with established IHD.

Adult↗

Prevalence of arrhythmias during 24-hour electrocardiographic monitoring and exercise testing in patients with obstructive and nonobstructive hypertrophic cardiomyopathy.

Many patients with hypertrophic cardiomyopathy die suddenly and unexpectedly, a significant number perhaps due to arrhythmia. Of 100 patients initially evaluated for signs or symptoms suggestive of heart disease or a family history of hypertrophic cardiomyopathy, 51 were selected solely because they met the echocardiographic criteria for the disease, and 49 patients were selected primarily because they had: 1) normal sinus rhythm despite left atrial enlargement, 2) a history of syncope, 3) a family history of premature death, or 4) a history of paroxysmal atrial fibrillation. All 100 patients were studied by 24-hour ambulatory electrocardiographic monitoring and 74 of them also underwent treadmill exercise testing. More than 50% of patients in repetitive ventricular premature depolarizations, including 19% who had ventricular tachycardia. Monitoring was superior to exercise testing for exposing these arrhythmias. Two patients experienced cardiac arrest within 2 months of monitoring; in each, monitoring had revealed ventricular tachycardia. Two patients with paroxysms of supraventricular tachycardia during monitoring developed fixed atrial fibrillation within 1 year. These preliminary observations suggest that monitoring may help identify patients at increased risk for significant arrhythmic events.

Adolescent↗

Prognostic importance of myocardial ischemia detected by ambulatory monitoring in patients with stable coronary artery disease.

To assess the relations of electrocardiographic measures of ischemia with the development of adverse coronary events, 86 patients with stable coronary artery disease and positive exercise tests for myocardial ischemia underwent ambulatory monitoring of the electrocardiogram. Monitoring was performed after withdrawal of antianginal medications, and prospective follow-up was obtained on routine medical care as prescribed by physicians who were unaware of monitor results. Forty-nine patients (57%) had a total of 426 episodes of ST segment depression; only 60 episodes (14%) were associated with symptoms of angina or an equivalent. During a mean follow-up of 12.5 +/- 7.5 months, there were two cardiac deaths, four myocardial infarctions, four hospitalizations for unstable angina, and 11 revascularization procedures required for new or worsening symptoms in 15 patients. All but one of these events (a hospitalization for unstable angina) occurred in the group of patients with ST segment depression on monitoring (p = 0.003). In multivariate analysis controlling for age, sex, and clinical descriptions of angina, the presence of ischemia on ambulatory monitoring was a significant predictor of outcome, while exercise test characteristics were not. Therefore, ischemia detected by ambulatory monitoring was common in patients with stable symptoms of coronary artery disease, and its presence identified a high-risk group for the development of subsequent unfavorable outcomes while on routine medical therapies.

Adult↗

Continuous intraoperative monitoring of middle cerebral artery blood flow velocities and electroencephalography during carotid endarterectomy. A comparison of the two methods to detect cerebral ischemia.

BACKGROUND AND PURPOSE: Intraoperative monitoring of brain function may influence the outcome of carotid endarterectomy (CEA). METHODS: We performed transcranial Doppler (TCD) monitoring of middle cerebral artery blood flow velocities (VMCAs) and eight-channel electroencephalographic (EEG) recording simultaneously in 82 patients undergoing CEA. Thiopental narcosis limited EEG interpretation in 11 patients, thus allowing direct comparison of both methods in 71 patients. RESULTS: There was a significant correlation between VMCA decrease and the frequency of EEG changes after carotid clamping (P < .001). Eight patients (11%) showed a VMCA decrease exceeding 60%, accompanied by EEG changes in 7 patients. Altogether, 16 patients (22%) showed severe or moderate EEG changes. Stenosis or occlusion of the contralateral carotid artery led to an increase of abnormal findings with both monitoring methods, which was, however, significant only for TCD (P < .05). Four patients (4.8%) suffered intraoperative transient ischemic attacks. In 3 of these patients, there were no abnormal findings with either of the methods. The events were thus unpredictable and probably of embolic origin. The fourth patient showed VMCA decrease to 0 and severe EEG changes. Nine patients had severe or moderate EEG changes without significant VMCA decrease and without complications. EEG monitoring alone in these would have led to unnecessary use of a shunt with the increased risk of embolism. CONCLUSION: EEG and TCD monitoring are complementary techniques. Their results showed a good overall correlation but with marked differences in the individual patient. TCD monitoring alone was sensitive enough to prevent ischemic intraoperative complications. EEG findings are of limited value when barbiturates are used.

Aged↗

Orbitofrontal cortex and social behavior: integrating self-monitoring and emotion-cognition interactions.

The role of the orbitofrontal cortex in social behavior remains a puzzle. Various theories of the social functions of the orbitofrontal cortex focus on the role of this area in either emotional processing or its involvement in online monitoring of behavior (i.e., self-monitoring). The present research attempts to integrate these two theories by examining whether improving the self-monitoring of patients with orbitofrontal damage is associated with the generation of emotions needed to guide interpersonal behavior. Patients with orbitofrontal damage, patients with lateral prefrontal damage, and healthy controls took part in an interpersonal task. After completing the task, participants' self-monitoring was increased by showing them a videotape of their task performance. In comparison to healthy controls and patients with lateral prefrontal damage, orbitofrontal damage was associated with objectively inappropriate social behavior. Although patients with orbitofrontal damage were aware of social norms of intimacy, they were unaware that their task performance violated these norms. The embarrassment typically associated with inappropriate social behavior was elicited in these patients only after their self-monitoring increased from viewing their videotaped performance. These findings suggest that damage to the orbitofrontal cortex impairs self-insight that may preclude the generation of helpful emotional information. The results highlight the role of the orbitofrontal cortex in the interplay of self-monitoring and emotional processing and suggest avenues for neurorehabilitation of patients with social deficits subsequent to orbitofrontal damage.

Adult↗

Recurrent laryngeal nerve monitoring during cricotracheal resection.

Cricotracheal resection has been advocated in the management of severe subglottic stenosis. One of the possible complications of this procedure is injury to the recurrent laryngeal nerve (RLN). We describe a new technique in which electrodes are placed directly through the thyroid cartilage to monitor the RLN intraoperatively. Nine cats' left vocal cords were monitored, and 3 cats had unilateral vocal cord injury postoperatively: 1 right cord and 2 left cords. Even though this technique was efficacious, our ability to monitor the RLNs was difficult secondary to difficulty interpreting the nerve monitor's wave morphologies. The future use of RLN nerve monitoring during cricotracheal resection will depend upon the ability to distinguish true stimulation from artifact. Monitoring of the RLN could be beneficial in patients with previous operations for subglottic stenosis.

Animals↗

Audiologic threshold monitoring of patients receiving ototoxic drugs. Preliminary report.

An effort was made to determine the efficacy of auditory threshold monitoring of patients receiving ototoxic drugs. Forty-four patients treated with either tobramycin or vancomycin for osteomyelitis were tested at the beginning of treatment, following treatment, and twice weekly during treatment when possible. All patients had renal function carefully monitored. Peak and trough drug levels were kept out of the toxic range throughout the study. In no patient did indisputable ototoxicity occur, and therefore, no conclusion about the most efficacious schedule for auditory monitoring of patients receiving ototoxic drugs was made, and what constitutes a significant intratherapeutic threshold shift is still in question. Until further data are collected, monitoring of renal function and peak and trough drug levels, as well as patient counseling, is recommended. Pretherapy and posttherapy auditory monitoring and intratherapeutic monitoring of high-risk patients and those who develop aural symptoms may prove beneficial.

Adolescent↗