PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “THROMBOPLASTIN”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95Linked to original sources

Preoperative evaluation of hemostasis in patients with congenital heart disease.

The incidence of abnormal results of coagulation tests and the risks for postoperative hemorrhage were assessed in 235 patients with congenital heart disease. Preoperatively, the prothrombin time, partial thromboplastin time, activated partial thromboplastin time, thrombin time, or platelet count was abnormal in 45 of the 235 patients (19%), a significantly higher incidence than that expected in a normal population (P less than 0.002). Prolonged values for the prothrombin time or the partial thromboplastin time or activated partial thromboplastin time were seen most frequently. Further evaluation in eight of the patients with prolonged prothrombin time or partial thromboplastin or activated partial thromboplastin time showed decreased levels of either factor VII or IX in six of them, suggesting that impaired vitamin K-dependent carboxylation is commonly present. Normal results of preoperative coagulation tests do not exclude the presence of a major bleeding diathesis (von Willebrand's disease was later diagnosed in a patient with such findings). The use of blood products during subsequent cardiac operations was not significantly different in patients with normal or abnormal test results. Two of the three patients who required reoperation and were found to have a nonsurgical cause of bleeding had abnormalities in two or more of the preoperative coagulation tests. This finding suggests that abnormal results of preoperative coagulation tests may be predictive of defective hemostasis in the postoperative period.

Adolescent↗

Effect of plasma pooling on the International Sensitivity Index of prothrombin time systems.

Guidelines set by the World Health Organization (WHO) state that in order to calibrate a prothrombin time system for International Sensitivity Index (ISI), freshly prepared specimens from 20 normal individuals and 60 patients receiving coumarin are required. These numbers are required to obtain a precise value of the calibration line slope when there is considerable scatter of individual data about the regression line. The scatter can be reduced by pooling individual plasma samples. In the present study, four pooled plasmas were prepared, one from 20 normal individuals and three from three groups of 30 patients receiving treatment with long-term oral anticoagulants. Prothrombin times were determined with four thromboplastins, HepatoQuick (rabbit thromboplastin combined with adsorbed plasma), Recombiplastin (recombinant human thromboplastin), Thromborel-S (human placenta), and Thromboplastin-C Plus (rabbit brain). Calibration line slopes were calculated for the six possible combinations of thromboplastins using the set of all individual plasma samples and the set of four pooled plasmas. In most comparisons, the WHO calibration model was appropriate, i.e. the line calculated for the patients' samples passed through the mean of the normals. The calibration line slopes obtained with the set of four pooled plasmas did not differ by more than 5% from the corresponding slopes calculated with the original individual plasmas. For some combinations of thromboplastins non-linear relations were observed both with the individual plasmas and with the pooled plasmas. We conclude that pooling individual plasmas does not significantly change the calibration relation between prothrombin times determined with the original individual plasmas. Freshly pooled plasmas can be used to determine the ISI of prothrombin time systems with an acceptable degree of precision.

Anticoagulants↗

Investigation of genotype-dependent differences in factor V activity as well as response to activated protein C by application of different methods.

Coagulation factor V has been at the centre of investigation for several years. In addition to factor V Leiden, various other polymorphisms are becoming the object of interest. Different results have been published about the association of the HR2 haplotype with decreased factor V levels and with reduced response to activated protein C (APC). Due to the central position of factor V in the clotting process, its activity can be determined in both thromboplastin-based and activated partial thromboplastin time (aPTT)-based assays. A multitude of assays are known for the determination of APC response. The aim of our study was to investigate whether different methods disclose genotype-dependent differences in factor V activity as well as APC response. Three wild-type carriers, three carriers homozygous for the R2 allele (4070G), and three carriers homozygous for the G allele (2391G, 2663G, 2684G, 2863G) were investigated. For each individual plasma sample, the factor V activity was determined using 12 different reagent combinations of three different thromboplastins, three different aPTT reagents, and two different factor V deficient plasma sources. The determination of factor V activity in the thromboplastin system revealed differences between the genotypes. These differences were independent of the thromboplastin reagent and the factor V-deficient plasma. The aPTT system exhibited a dependency on the aPTT reagent and the factor V-deficient plasma. Analysis of APC response disclosed genomic differences in specific test systems only. One type of assay could be more appropriate than other types in dependence of the position of genomic variations. Therefore, the applied assay is an important influential factor in investigations of functional consequences of genomic variations.

Alleles↗

Effects of DX-9065a, an orally active, newly synthesized and specific inhibitor of factor Xa, against experimental disseminated intravascular coagulation in rats.

We investigated the protective effects of DX-9065a, an orally active, newly synthesized and specific inhibitor of factor Xa, against two kinds of experimental disseminated intravascular coagulation (DIC) in rats. Endotoxin-induced experimental DIC was induced by a 4-h sustained infusion of endotoxin at a dose of 100 mg/kg. Thromboplastin-induced experimental DIC was induced by a bolus injection of thromboplastin at a dose of 150 mg/kg. The rats were orally administered DX-9065a at 10, 30 or 100 mg/kg 30 min before endotoxin or thromboplastin injection. In both DIC models, DX-9065a showed a protective effect against DIC, at all doses and in all parameters, including fibrin/fibrinogen degradation products (FDP), fibrinogen level, prothrombin time, activated partial thromboplastin time, platelet count and the number of renal glomeruli with fibrin thrombi. When DX-9065a was orally administrated at 100 mg/kg without endotoxin or thromboplastin, no significant changes were seen in hemostatic parameters except PT and APTT, and no fibrin thrombi or abnormal bleeding were seen in renal specimens. These findings suggest that the new oral anti-Xa drug, DX-9065a, has an effect in reducing the severity of DIC. However, further dose-finding and safety studies of this drug have still to be assessed.

Administration, Oral↗

An evaluation of several laboratory tests and test combinations in the detection of lupus anticoagulant.

The laboratory assessment of the lupus anticoagulant, a factor frequently associated with venous and arterial thrombosis, recurrent miscarriages and abortions, is not straightforward, as indicated by the variety of tests proposed and the different results obtained. On account of the marked variability and heterogeneity of lupus anticoagulant among patients, no single test or reagent will identify all patients with lupus anticoagulant, and a panel of several tests has to be used. This is time consuming and increases the workload of the laboratory. The aim of this study was to assess the minimum number of tests necessary for the satisfactory identification of the patient with lupus anticoagulant. Our study confirms that lupus anticoagulant may be present in a significant number of patients with normal routine activated partial thromboplastin time, a test which therefore cannot be used as the sole criterion for identifying patients suspected of having lupus anticoagulant. In contrast all patients who had positive results in at least one test could be detected (100% sensitivity) with two combinations of tests: (1) dilute activated partial thromboplastin time and Kaolin clotting time and (2) dilute activated partial thromboplastin time and tissue thromboplastin inhibition test. Since the latter inhibition test has been reported to give a high number of false-positive or negative results, we suggest the combination of dilute activated partial thromboplastin time and Kaolin clotting time as the standard pair of tests for the screening of suspected lupus anticoagulant patients.

Antiphospholipid Syndrome↗

Monitoring anticoagulation following intracoronary procedures: which method?

We have assessed bedside kits for monitoring the activated partial thromboplastin time and the activated clotting time by comparing them with laboratory activated partial thromboplastin time values. To determine the accuracy of anticoagulation we have concurrently measured the plasma heparin concentrations, and plasma prothrombin fragment F1 + 2 concentrations. Serial samples were taken from patients undergoing elective percutaneous transluminal coronary angioplasty (n = 14). Readings were taken pre-procedure, 30 min after administration of a heparin bolus (10,000 U) and 1, 2 and 3 h after commencement of a constant heparin infusion (15 U/kg/h) postprocedure. Activated partial thromboplastin time results obtained with the bedside kit compared reliably with laboratory values (r = 0.8), were rapidly available and were reflected by appropriate changes in prothrombin fragment F1 + 2 and heparin concentrations. However, the relationship between activated partial thromboplastin time values and activated clotting time was less precise (r = 0.59). Therefore, for routine and frequent monitoring of anticoagulation with heparin, a bedside activated partial thromboplastin time kit provides adequate control of therapy but in instances were particularly tight control of anticoagulation is required, use of prothrombin fragment F1 + 2 concentrations may be more appropriate.

Angioplasty, Balloon, Coronary↗

An international collaborative study on the INR calibration of freeze-dried reference plasmas.

A study was carried out to calibrate potential European Reference Plasmas for prothrombin time (PT) standardization. The International Normalized Ratio (INR) values of three freeze-dried candidate plasmas (one pooled normal and two pools from anticoagulated patients) were determined in 20 laboratories using six thromboplastin reagents comprising three International Reference Thromboplastins (human, rabbit and bovine), two recombinant human reagents and one placental human reagent. Interlaboratory variability of INR estimation was low with geometric coefficients of variation (gcv) <10% except in one case. Significant differences in mean INR were found between the different thromboplastins with lowest INR values found with the bovine reagent. INR values from the International rabbit and human reagents differed by <6% and were combined to give proposed assigned INR values. Significant differences in INR estimates from four thromboplastins of human origin may indicate that single assigned INR values are not applicable for use with all thromboplastin reagents. Field trials to assess the validity of single assigned INR values in clinical practice are required.

Animals↗

The value of plasma calibrants in correcting coagulometer effects on international normalized ratios. An international multicenter study.

A study of lyophilized plasma calibrants in correcting for coagulometer effects on International Normalized Ratios (INR) has been conducted in an international survey. Prothrombin times were performed with the calibrants on 2 "common" thromboplastins and in-house thromboplastins in 3 brands of coagulometer at 37 centers. The International Sensitivity Indices (ISI) of 95 local systems with the calibrants were derived. The "true" INR of 10 test plasmas from warfarin-treated patients were established centrally using thromboplastin International Reference Preparations (IRP). International Normalized Ratios of these plasmas for each center were calculated using both the manufacturers' stated and the local ISI. The mean deviation of the 95 systems from the "true" INR of the warfarin plasmas was +14.4% with the manufacturers' ISI, but reduced to +1.04% with the local ISI. Local ISI determination with the calibrants avoids many of the difficulties of conventional thromboplastin calibrations. Plasmas from patients on warfarin and parallel manual PT with thromboplastin IRP are not required.

Blood Coagulation Tests↗

Characterization and comparison of immune-depleted and hereditary factor-VII-deficient plasmas as substrate plasmas for factor VII assays.

The functional activity of coagulation factors usually is determined using bioassays dependent on substrate plasmas deficient in the factor being measured. These are obtained most often from patients with hereditary deficiency and are frequently poorly characterized. The authors characterized seven commercially available hereditary Factor-VII-deficient substrate plasmas in terms of Factor VII activity and antigen level, and then compared them with a Factor-VII-deficient plasma prepared by immunoadsorption. All of the hereditary Factor-VII-deficient plasmas contained significant quantities of Factor VII antigen (120-217 ng/mL; normal, 250-600 ng/mL). One of the commercial substrate plasmas showed significant factor VII coagulant activity with a human thromboplastin. The sensitivity of the Factor VII assay system was dependent on both the source of Factor-VII-deficient plasma and the origin of the thromboplastins; human thromboplastin was more sensitive than rabbit thromboplastin, and immune-depleted plasma gave the most sensitive assay with each thromboplastin. These results indicate that immunoadsorbed plasma may be a superior reagent for coagulation factor assays.

Blood Coagulation Tests↗

Recombinant hirudin as a periprocedural antithrombotic in coronary angioplasty for unstable angina pectoris.

Percutaneous transluminal coronary angioplasty is often complicated by thrombotic abrupt vessel closure in patients with unstable angina pectoris. The present multicentre trial was performed to determine the feasibility of two-dose regimens of recombinant hirudin (r-hirudin) compared to standard heparin in patients undergoing coronary angioplasty for unstable angina, and to investigate the effects of the different treatment regimen on markers of coagulation activation. At five participating centres, 61 patients were randomly enrolled in one of two sequential groups of r-hirudin (group 1: 0.3 mg.kg-1 i.v. bolus, 0.12 mg.kg-1.h-1 i.v. infusion; 21 patients; group 2: 0.5 mg.kg-1 i.v. bolus, 0.24 mg.kg-1.h-1 i.v. infusion; 19 patients) or in a heparin control group (150 IU.kg-1 i.v. bolus, 20 IU.kg-1.h-1 i.v. infusion; 21 patients). Antithrombotic therapy was started immediately before coronary angioplasty and continued for 24 h. This was followed by a low-dose anticoagulant infusion for another 24 h (r-hirudin: 0.04 mg . kg-1 . h-1; heparin: 7 IU . kg-1 . h-1). Activated partial thromboplastin time, r-hirudin plasma concentrations by both immunological and functional assay, thrombin-hirudin complex, thrombin-antithrombin III complex, soluble fibrin, and prothrombin fragment 1 + 2 were closely monitored. The median partial thromboplastin time prolongations at 24 h vs baseline were found to be 1.9-fold and 2.3-fold in r-hirudin group 1 and dose group 2, respectively, and 3.0-fold in the heparin group. There was a dose-dependent correlation between partial thromboplastin time and the r-hirudin plasma levels (r = 0.61). In five of 21 patients of dose group 1, three of 19 patients of dose group 2, and 10/21 patients of the heparin group, partial thromboplastin time values exceeding the predefined target range prompted an interruption of the infusion. One major bleeding complication occurred in dose group 2. The functional assay for the estimation of r-hirudin plasma concentrations showed excellent correlations to the immunological technique (r = 0.99). Differences between the thrombin-hirudin complex levels could not be observed. Increased concentrations of thrombin-antithrombin III complex, soluble fibrin, and prothrombin fragment 1 + 2 were seen 4-8 h after coronary angioplasty and after reduction of the high-dose therapy in dose group 1 when compared with dose group 2 and the heparin group, respectively. Based on coagulation tests the present study showed the feasibility of a periprocedural antithrombotic regimen with r-hirudin for patients undergoing coronary angioplasty for unstable angina. In addition to the partial thromboplastin time the determination of r-hirudin plasma levels by a chromogenic substrate assay considerably improves the monitoring of therapy. The lower dose r-hirudin regimen seems to be suboptimal as periprocedural anticoagulation in coronary angioplasty patients as indicated by markers of thrombin generation and thrombin activity.

Adult↗

A new animal model of venous thrombosis in rats with low flow conditions in the venous blood stream.

The aims of the present investigation were to develop a new venous thrombosis animal model with low flow conditions in the venous blood stream and then evaluate this model for testing new anticoagulants. In this model, the vena cava of rats was narrowed with a Doppler flow probe, blood flow velocity continuously recorded and thrombus formation initiated by thromboplastin infusion. Sixty-five minutes following thromboplastin infusion the animals were sacrificed and the following parameters measured: thrombus wet weight, fibrinopeptide A (FpA), activated partial thromboplastin time and platelet number. The new model was evaluated with aspirin, a PGI2 mimetic, heparin and a soluble thrombomodulin analogue. Without thromboplastin infusion no thrombus formation or reduction of blood flow was observed. Controls receiving thromboplastin infusion developed a thrombus, blood flow was arrested, platelet number decreased and FpA was elevated. In contrast, animals pretreated with anticoagulants maintained a residual flow, while thrombus weight, thrombocytopenia and FpA elevation were reduced. The antiplatelet agents were not effective. This study demonstrates that, under low flow conditions, only a combination of blood flow reduction with a hypercoagulable state results in venous thrombus formation. This improved model of venous thrombosis more closely resembles the clinical situation and is applicable for testing anticoagulants.

Animals↗

Standardization of factor VII/activated factor VII measurement in plasma of patients treated with recombinant factor activated VII.

To improve the standardization of the factor VII clotting activity (FVII:C) assay in patients treated with recombinant activated factor VII (rFVIIa), we conducted a multicentre study on plasma samples from four patients with haemophilia A, before and at various times after injection of a single dose of rFVIIa. FVII:C and prothrombin time were measured with the methods and reagents routinely used in each laboratory. Strong inter-laboratory variability of FVII:C values was found. The main source of variability was the type of thromboplastin. FVII:C values measured using rabbit thromboplastin were very close to activated factor VII clotting activity values (FVIIa:C) measured with a commercial assay (Staclot VIIa-TF). FVII:C values obtained with human placental thromboplastin were about three times lower than those obtained with rabbit and recombinant thromboplastins, and with the FVIIa:C assay. There was a good relationship between FVIIa:C and activated factor VII antigen values measured using a commercial immunoassay (Imubind FVIIa ELISA). In conclusion, rFVIIa at pharmacological concentrations can be easily monitored on the basis of FVII:C, using rabbit and probably also recombinant thromboplastin; equivalent results are obtained with a specific activated factor VII bioassay.

Animals↗

Are coagulation studies on blood sampled from arterial lines valid?

Coagulation tests were performed on two venous blood samples and two blood samples from arterial lines taken from 79 patients on an intensive care unit. For the first arterial sample the discard volume was 4.5 ml and for the second arterial sample the discard volume was 16 ml. From each pair of venous samples a mean venous coagulation value was calculated. There were statistically significant differences between arterial and venous results and between the two arterial samples for activated partial thromboplastin time and thrombin time assays but not for prothrombin time, reptilase time and fibrinogen assays. However, these differences were sufficiently small to be of little clinical significance. The bias for the difference in activated partial thromboplastin time values between the first arterial sample and the venous sample was +1.24 s (limits of agreement: -4.39 to +6.87 s) and between the second arterial sample and the venous sample the bias was +0.89 s (limits of agreement: -3.25 to +5.03 s). Only 3.8% of first arterial samples and 1.3% of second arterial samples produced activated partial thromboplastin time values that were more than 10% longer than the corresponding venous values. No heparin was detectable in these arterial samples using a heparin assay (< 0.02 iu.ml-1). The differences between arterial and venous activated partial thromboplastin times were slightly but not significantly greater in subgroups of patients with moderately or severely deranged coagulation compared with a group with normal coagulation. We conclude that samples from arterial lines provide valid activated partial thromboplastin time results using a discard volume of either 4.5 ml or 16 ml.

Adult↗

The activity state of factor VII in plasma: two pathways for the cold promoted activation of factor VII.

The apparent amount of factor VII as determined in a one-stage test depends on the type of thromboplastin used: bovine thromboplastin only reacts with human factor VIIa whereas human thromboplastin interacts with unactivated human factor VII as well. Therefore the ratio factor VII activity as measured with bovine thromboplastin divided by the factor VII activity as assessed with human thromboplastin reflects the state of activation of factor VII in plasma. This approach was used to study the process of cold promoted factor VII activation and the involvement of different clotting factors therein. It could be shown that cold promoted activation does not occur in the absence of factors II and XII and is reduced for about 50% in factor IX deficient plasma. The other coagulation factors have a minor influence on the process. The results indicate that the cold promoted factor VII activation is the result of activation by both activated contact products and thrombin.

Adult↗

Blood plasma coagulation studied by surface plasmon resonance.

A surface plasmon resonance (SPR) apparatus was used to investigate blood plasma coagulation in real time as a function of thromboplastin and heparin concentrations. The response curves were analyzed by curve fitting to a sigmoid curve equation, followed by extraction of the time constant. Clotting activation by thromboplastin resulted in increased time constant, as compared to spontaneously clotted plasma, in a dose dependent way. Addition of heparin to the thromboplastin-activated plasma counteracted this effect. Atomic force microscopy (AFM) pictures of sensor surfaces dried after completed clotting, revealed differences in fibrin network structures as a function of thromboplastin concentration, and the fiber thickness increased with decreased thromboplastin concentration. The physical reason for the SPR signal observed is ambiguous and is therefore discussed. However, the results summarized in the plots and the fibrin network properties observed by AFM correlate well with present common methods used to analyze blood coagulation.

Anticoagulants↗

Circadian changes in anticoagulant effect of heparin infused at a constant rate.

Six patients with venous thromboembolism were treated with heparin, administered intravenously by a constant infusion pump. The initial daily dose of heparin was adjusted to keep the activated partial thromboplastin time, sampled at 0800, between 1.5 and 2.5 times the control level. Once that level was obtained, this dose was kept constant. Anticoagulation was thereafter measured, every four hours for 48 hours, by activated partial thromboplastin time, thrombin time, and coagulation factor Xa inhibition assay. The results of all three coagulation tests showed a circadian variation in the six patients. Maximum values were achieved at night and minimum values in the morning. These circadian variations were reproduced for two consecutive days. Differences between night and morning values reached almost 50% for activated partial thromboplastin time, 60% for thrombin time, and 40% for factor Xa inhibition assay. This circadian variation resulted from two rhythms, a circadian rhythm lasting 24 hours and an ultradian rhythm lasting 12 hours, which were detected by cosinor analysis for each coagulation test (p less than 0.01). A circadian rhythm was detected individually in most of the patients for each coagulation test (p less than 0.05). All patients had a nocturnal peak in activated partial thromboplastin time on both days. In four patients this peak exceeded the upper desired limit of activated partial thromboplastin time. These rhythms should be taken into account when evaluating the dosage of heparin to be administered.

Aged↗

The importance of "like to like" ISI calibrations with freeze dried plasmas. European Concerted Action on Anticoagulation.

AIM: To assess reliability of like to like and cross species calibrations using two types of certified freeze dried plasma calibrants--artificially depleted of vitamin K clotting factors, and from coumarin treated patients. METHODS: Six ECAA national control laboratories provided certified values for the freeze dried plasmas in terms of the human plain international reference preparation (IRP) (BCT/441) with the manual prothrombin time technique. Eight other ECAA national laboratories determined international sensitivity index (ISI) values in full fresh plasma same species and cross species WHO calibrations against a low ISI human IRP (BCT/441) of the ECAA low ISI human thromboplastin and high ISI ECAA rabbit thromboplastin. Parallel calibrations were performed using the certified values. RESULTS: Calibrations on fresh plasmas of the human ECAA reference thromboplastin (stated ISI = 0.95) gave ISI of 0.957 against the human IRP and 1.66 against the rabbit IRP. The ECAA rabbit (stated ISI = 1.67) gave an identical value on the fresh plasma calibration v the human IRP. With freeze dried depleted plasmas certified in terms of the human IRP, the ISI of the ECAA human was 1.01, but the ECAA rabbit (stated ISI = 1.67) gave a low ISI of 1.47. The freeze dried coumarin plasmas gave an ISI of 0.943 for the ECAA human but only 1.493 for the ECAA rabbit. CONCLUSIONS: Fresh plasmas give reliable ISI when calibrating thromboplastins in same species and cross species calibrations. Freeze dried plasmas certified in terms of a single IRP, whether artificially depleted or of coumarin plasma origin, cannot be used for calibration of dissimilar thromboplastins.

Anticoagulants↗

The international normalized ratio (INR) for monitoring warfarin therapy: reliability and relation to other monitoring methods.

OBJECTIVE: To enhance understanding of the reliability of the international normalized ratio (INR) for monitoring warfarin therapy and its relation to other monitoring techniques. DESIGN: Prospective cohort study. SETTING: A university hospital. PATIENTS: 79 patients attending an anticoagulation clinic. MEASUREMENTS: International normalized ratios obtained with a portable capillary monitor (Coumatrak) and the following from a simultaneous plasma sample: INRs from prothrombin times done with six thromboplastins, prothrombin-proconvertin (P&P) test activity, specific prothrombin activity, and native prothrombin antigen. RESULTS: Converting to INRs failed to standardize prothrombin time results obtained with high- and low-sensitivity thromboplastins. Coumatrak INRs correlated best with INRs obtained with high-sensitivity thromboplastins. The INR range of 2.0 to 3.0 corresponded to a P&P range of 30% to 13%, a native plasma prothrombin antigen range of 56 to 24 micrograms/mL, and a specific prothrombin activity range of 43% to 21%. CONCLUSIONS: Low-sensitivity thromboplastins may give erroneously high INRs in the upper therapeutic range. Plasma prothrombin times should be done with a high-sensitivity thromboplastin, particularly in patients maintained at the upper limit of the therapeutic range. An INR so obtained correlated well with an INR obtained with a portable capillary blood monitor.

Autoantigens↗