PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Flow Cytometry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96Linked to original sources

Interphase cell flow cytometry as a means of monitoring genomic size in normal and neoplastoid cell cultures.

The DNA specific fluorescence of mass cultures and clones derived from human skin and bladder tumor tissue was assayed by flow cytometry. In order to detect and quantitate small fluorescence intensity changes, cytogenetically defined triploid or diploid human fibroblast strains were cocultivated, harvested, and stained with the cell strain of unknown karyotype. The triploid standard (derived from human abortus tissue) proved chromosomally unstable at high passage level. Fifteen male, female, and 45,X strains displayed target-to-standard cell fluorescence ratios commensurate with their respective chromosome constitutions. Interstrain variation was highest among the 45,X strains, although mosaicism could not be detected by conventional cytogenetics. Interclonal fluorescence variation was two- to ten-fold higher among the tumor-derived clones tested. Chromosome counts and subcloning experiments indicate that this increased fluorescence variation is due to genome size variation. The clonal evolution of genome size differences was observed in subclones of chromosomally divergent parental clones. These observations suggest that well controlled flow cytometry can adequately resolve subtle degrees of genome size variation in cultivated human cells. The technique is especially suited for monitoring genome size changes in cultivated tumor cells.

Cell Separation↗

Potential use of flow cytometry in toxicity studies with microalgae.

Cytotoxic effects of aquatic pollutants on microalgae are very heterogeneous, and they are influenced by environmental conditions and the test species. Stress produced by copper or paraquat addition to the culture medium of two microalgae was analysed by flow cytometry. Parameters assayed were: cell volume, chlorophyll a fluorescence and cell viability. The variety of results obtained in the present study reveals that flow cytometry is a useful tool in the toxicity tests with microalgae, both marine and freshwater species, and for different kind of pollutants.

Cell Division↗

Structural mapping of immunoglobulin subclasses using multiplexed bead flow cytometry.

Monoclonal hybridomas secrete immunoglobulin molecules with a single specificity and distinct class/subclass structure. The determination of immunoglobulin structure can be used to facilitate hybridoma colony management and predict monoclonality. In this report, we used multiplexed bead flow cytometry to define hybridoma class/subclass. The assay was sufficiently sensitive to detect 50 ng/mL of antibody. The multiplexed bead assay efficiently defined traditional class/subclass determinants as well as more subtle patterns of crossreactivity. Further, the assay was combined with Poisson statistics to provide a numerical estimate of hybridoma monoclonality. The sensitivity and flexibility of this approach suggests the utility of multiplexed bead flow cytometry in the early management of immunoglobulin-secreting hybridomas.

Animals↗

Phenotypic analysis of plasma cells in bone marrow using flow cytometry in AL amyloidosis.

AL amyloidosis is an intractable disease resulting from a plasma cell dyscrasia which has a wide clinical spectrum. To investigate the phenotype of plasma cells in the bone marrow, a flow cytometric analysis was carried out in 10 patients with this disease (mean age, 57.8 +/- 7.9 years) and controls with M-protein (positive controls, n = 4) and without it (negative controls, n = 8). All patients were shown to have either A kappa- or A lambda-immunoreactive amyloid deposits on the biopsied tissues. On flow cytometry CD38++CD19+CD56- cells (polyclonal plasma cells) showed no significant difference between patients (0.59 +/- 0.37%) and either negative (2.25 +/- 2.84%) or positive controls (0.38 +/- 0.20%), while CD38++CD19-CD56+ cells (monoclonal plasma cells) showed a significantly higher level in the patients (1.34 +/- 1.54%) than in either negative (0.041 +/- 0.004%, p < 0.005) or positive controls (0.11 +/- 0.09%, p < 0.05). With respect to maturation of plasma cells, five of the patients (50%), three of the positive controls (75%) and all of the negative controls showed a dominant proliferation of mature subtype (CD45+MPC-1+CD49e- or CD45+MPC-1+CD49e+). Immature (CD45+MPC-1- or CD45-MPC-1-) and intermediate (CD45-MPC-1+CD49e-) subtypes were dominantly present in the bone marrow in 2 and 3 patients, respectively. In AL amyloidosis monoclonal plasma cells producing M-protein can be easily and reliably detected in the bone marrow by flow cytometry. This analysis might provide plasma cell phenotypic markers useful for assessing the prognosis and for monitoring the response to treatment.

ADP-ribosyl Cyclase↗

Rapid identification and detection of parasitized human red cells by automated flow cytometry.

Rapid and reliable identification of various human red cells parasites is important in many chemotherapeutic and immunologic studies. Because manual microscopic counting is tedious and imprecise, we have developed a simple diagnostic procedure for the automated flow cytometric detection of in vitro infected red cells, using a nucleic acid-binding fluorescent dye, acridine orange. Human malaria (Plasmodium falciparum)-infected red cells from continuous human erythrocyte culture were incubated at room temperature in acridine orange stain for 5 min after which the samples were analyzed by flow cytometry. Since mature red cells contain no DNA, infected red cells were identified with a distinct fluorescent signal. A total of 200,000 cells per sample were counted and analyzed in less than 2 min. Rings, trophozoites, and schizonts were assessed and identified in synchronized infected red cell cultures by flow cytometry. In addition, various stages of infected red cells were isolated with a cell sorter. This rapid method permits accurate and reliable assessment of data with the exclusion of anomalous data such as damaged cells, extraneous material, and contaminating particles.

Acridine Orange↗

Multiplexed, particle-based detection of DNA using flow cytometry with 3DNA dendrimers for signal amplification.

BACKGROUND: Complex mixtures of DNA may be found in environmental and medical samples. There is a need for techniques that can measure low concentrations of target DNAs. For a multiplexed, flow cytometric assay, we show that the signal-to-noise ratio for fluorescence detection may be increased with the use of 3DNA dendrimers. A single fluorescent DNA molecule per bead could be detected with conventional flow cytometry instrumentation. METHODS: The analyte consisted of single-stranded (ss) DNA amplicons that were hybridized to capture probes on the surface of fluorescent polystyrene microspheres (beads) and initially labeled with streptavidin-R-phycoerythrin (single-step labeling). These beads have a low reporter fluorescence background and high efficiency of DNA hybridization. The DNA/SA-RPE complex was then labeled with 3DNA dendrimers and SA-RPE. The bead complexes were detected with a Luminex 100 flow cytometer. Bead standards were developed to convert the intensity to the number of SA-RPE labels per bead and the number of dendrimers per bead. RESULTS: The dendrimer assay resulted in 10-fold fluorescence amplification compared with single-step SA-RPE labeling. Based on concentration curves of pure target ss-amplicons, the signal-to-noise ratio of the dendrimer assay was greater by a factor of 8.5 over single-step SA-RPE labeling. The dendrimer assay was tested on 16S ribosomal DNA amplified from filter retentates of contaminated groundwater. Multiplexed detection of a single dendrimer-labeled DNA molecule per bead was demonstrated. CONCLUSIONS: Multiplexed detection of DNA hybridization on a single molecule level per bead was achieved with conventional flow cytometry instrumentation. This assay is useful for detecting target DNAs at low concentrations.

Calibration↗

Flow cytometry identification of X- and Y-chromosome-bearing goat spermatozoa.

Flow cytometric sorting technology was used to measure the difference in DNA content between X- and Y-chromosome-bearing spermatozoa in bucks. Spermatozoa were analysed by flow cytometry to characterize X- and Y-chromosome-bearing sperm populations and to quantify the DNA difference between them. Two symmetrical, overlapping and clearly separated peaks, corresponding to X- and Y-bearing spermatozoa, were detected. The difference in fluorescence intensity between the peaks was 4.4 +/- 0.03% without any significant inter- or intra-animal variations. Therefore, the identification and selection of high-purity samples of sperm populations for sex sorting is easier in bucks compared with other domestic species.

Animals↗

Estimation of nuclear DNA content by flow cytometry in fishes of the genus Xiphophorus.

1. By use of flow cytometry we measured nuclear DNA content in cells from 16 stocks representing 9 species of the genus Xiphophorus. 2. Significant differences were detected between certain stocks and species with respect to DNA content. 3. Male-female differences were apparent in 5 of 7 stocks in which males and females were studied. 4. Estimation of nuclear DNA content is of potential significance in connection with the genetics of sex determination and the study of taxonomic relationships.

Animals↗

Use of fluorescence flow cytometry to study the binding of various ligands to platelets.

Fluorescence flow cytometry can be used to analyze the binding of different ligands to platelets. However careful choice of volume gates is essential in selecting the population of platelets for analysis. The use of fluorescein isothiocyanate conjugated to staphylococcal protein A or F(ab')2 fragments of immunoglobulin G anti-immunoglobulin offers no advantage in sensitivity or specificity in fluorescence studies of platelets and prefixation of washed platelets with paraformaldehyde has no effect on nonspecific fluorescence. The application of this technology to platelets facilitates quantitation of fluorescence intensity and may yield additional useful information.

Blood Platelets↗

Characterization and cell cycle kinetics of hepatocytes during rat liver regeneration: in vivo BrdUrd incorporation analysed by flow cytometry and electron microscopy.

The incorporation of bromodeoxyuridine (BrdUrd) into newly synthesized DNA has been analysed during hepatocellular regeneration induced by partial hepatectomy in young rats. The kinetic state of the liver has been studied by flow cytometric analysis of the incorporated BrdUrd, while the fine localization of DNA replication sites through the cell cycle has been investigated at the ultrastructural level by the immunogold technique. Eighteen hours after partial hepatectomy flow cytometry revealed an early S phase distribution which corresponded to a specific staining of the interchromatin domains of the hepatocyte nucleus. Thirty-four hours after hepatectomy, on the other hand, when most cells were in late S, a specific staining of heterochromatin domains was observed. The effect of the BrdUrd technique on nuclear aggregation has also been analysed and discussed. The results demonstrate that specific patterns of DNA replication can be recognized during the cell cycle and that flow cytometry and electron microscopy appear to be complementary in the kinetic study of liver regeneration.

Animals↗

Characterization of hematologic malignancies by flow cytometry.

The quantitative assessment of cellular DNA and RNA content by flow cytometry to provide useful information for both diagnosis and prognosis of patients with hematologic malignancies is reviewed. While the characterization of cell surface antigens seems to be more germane to questions of the normal cell counterpart (stage) of malignant transformation and the biology of regulation of proliferation and differentiation by cell-cell contact and humoral factors, DNA-derived and RNA-derived parameters were surprisingly sensitive in the distinction of major morphologic groups, drug sensitivity and long-term prognosis. Our findings to date in the study of leukemias, lymphomas and myelomas are summarized.

DNA, Neoplasm↗

[Flow cytometry and its application in andrological studies].

As an advanced technology, flow cytometry has its unique advantages in detecting single cells quantitatively and rapidly. So it has been used more and more widely in clinical examination. FCM offers a powerful tool and exciting opportunities for accurately evaluation of semen quality and sperm functions. And it's a new idea to apply this technology in andrological studies. This review introduces its basic principles, summaries its present and potential application in andrology studies, including separating and identifying spermatozoa, analyzing spermids structure and function, examining the biological active substances in semen and on the surface of spermids.

Andrology↗

Immunocytochemical detection of estrogen receptors in bone cells using flow cytometry.

A sensitive method for immunocytochemical detection of estrogen receptors using flow cytometry is reported. Using this method, estrogen receptors were detected in several osteoblastic cell lines with established expression of estrogen receptors, and for the first time, estrogen receptors were also demonstrated in murine fibroblasts and in human primary marrow stromal cells. The distribution of estrogen receptors within all cell lines was unimodal. The method enables for studies of estrogen receptors in the cell types which express low to moderate levels of the receptors, for studies of heterogeneity of the receptors' expression and for simultaneous detection of several parameters on a single-cell level.

Animals↗

Immunophenotyping of surface antigens in acute myeloid leukemia by flow cytometry after red blood cell lysis.

Immunophenotyping of acute leukemia using flow cytometry after density gradient separation (dg-sep) of mononuclear cells is the international gold standard. But destroying red cells by whole blood lysis (wb-lysis) after direct staining has found a broad usage. Both methods revealed congruent results in phenotyping of 26 cases of acute myeloid leukemias by testing CD4, CD7, CD11b, CD11c, CD13, CD14, CD15, CD33, CD34, CD65s, Glycophorin A and HLA-DR antigens. Mean values of these tested antigens were very similar. Only low antigen expression of CD2 was missed in the phenotype of two AML cases by the wb-lysis (23 and 29% positive cells by the dg-sep).

Adult↗

Biotinylation of human interleukin-2 for flow cytometry analysis of interleukin-2 receptors.

We designed a method to analyze receptors for interleukin-2 (IL-2R) using biotinylated IL-2 (b-IL-2). To optimize the condition of biotinylation of IL-2 for flow cytometry, the degree of biotinylation was controlled by monitoring the relative biotin contents in b-IL-2 with a newly developed ELISA. The b-IL-2 prepared by incubating 150 micrograms IL-2 in 150-300 micrograms/ml N-hydroxysuccinimidyl biotin retained biological activity and was appropriate for flow cytometry analysis. Positive fluorescence appeared in the IL-2R-bearing cell lines but not in those without IL-2R. This binding was inhibited by preincubation of the cells with unlabelled IL-2. The b-IL-2 bound to both low and high affinity IL-2Rs, but the binding to the latter was more intense. The advantage of this method is that expression of IL-2Rs of these two categories of affinity can be separately monitored.

Antibody Affinity↗

Simultaneous analysis of immunophenotype and apoptosis of murine thymocytes by single laser flow cytometry.

The study of the role of apoptosis in thymocyte development has been hampered by the lack of a means of directly immunophenotyping cells undergoing the early phase of apoptosis. This restriction has been overcome by single laser flow cytometry in which apoptosis is detected by Ethidium Bromide (EBr) staining and cell phenotype by binding of FITC-labelled antibody. The initial phase of apoptosis is observed as a cell population that stains faintly with EBr preceding the characteristically bright EBr-staining normally associated with cell death. Here we directly demonstrate using single laser flow cytometry that CD4+ CD8+ CD3low/CD3intermediate thymocytes undergo apoptosis in vitro in response to glucocorticoid treatment.

Animals↗

Development of a mechanism-based, DNA staining protocol using SYTOX orange nucleic acid stain and DNA fragment sizing flow cytometry.

Accurate measurement of single DNA fragments by DNA fragment sizing flow cytometry (FSFC) depends upon precise, stoichiometric DNA staining by the intercalating dye molecules. In this study, we determined the binding characteristics of a commercially available 532 nm wavelength-excitable dye and used this information to develop a universal DNA staining protocol for DNA FSFC using a compact frequency-doubled Nd:YAG laser excitation source. Among twelve 532 nm wavelength-excitable nucleic acid staining dyes tested, SYTOX Orange stain showed the highest fluorescence intensity along with a large fluorescence enhancement upon binding to double-stranded DNA ( approximately 450-fold). Furthermore, using SYTOX Orange stain, accurate fragment-size-distribution histograms were consistently obtained without regard to the staining dye to base pair (dye/bp) ratio. A model describing two binding modes, intercalation (primary, yielding fluorescence) and external binding (secondary, involving fluorescence quenching), was proposed to interpret the performance of the dyes under different dye/bp ratios. The secondary equilibrium dissociation constant was found to be the most critical parameter in determining the sensitivity of each fluorophore to the staining dye/bp ratio. The measurements of both equilibrium dissociation constants provided us with a theoretical framework for developing a universal protocol which was successfully demonstrated over a wide range of DNA concentrations on a compact flow cytometer equipped with a frequency-doubled, diode-pumped, solid-state Nd:YAG laser for rapid and sensitive DNA fragment sizing.

Bacteriophage lambda↗