PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Monitoring”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96Linked to original sources

Intraoperative monitoring of the visual evoked potential during endoscopic sinus surgery.

Iatrogenic blindness resulting from conventional and endoscopic sinus surgery continues to be a major concern to the head and neck surgeon. A new electrophysiologic monitoring technique has been developed that can help avoid damage to the optic nerve and visual system. The approach involves monitoring the visual evoked potential with presentation of flash stimuli to the eyes. Thirty patients with chronic sinusitis underwent endoscopic sinus surgery with visual evoked potential monitoring. The procedures were carried out with patients under intravenous general anesthesia. Needle cortical electrodes were placed in the scalp. A modified light-emitting diode array/goggle was positioned in front of the patient's closed eyes. A triggered flash of 2 Hz was delivered through the goggle to stimulate the patient's retina. Cortical responses were amplified and averaged for 100 trials. Amplitude and peak-latency changes were monitored to alert the surgeon to any change in the visual response during the surgical dissection. Although no changes in response were noted during dissection, cold-water irrigation and reflected telescopic light could produce variations in the recorded responses, as will be discussed. Visual evoked potential monitoring may prevent a surgeon from continuing a bilateral procedure when there is indication of iatrogenic visual loss from dissection on the first side. Visual evoked potential also reassures the operator that no damage has occurred to the visual pathway at the conclusion of a case. Methods, case selection, operative technique, and documentation of monitoring will be discussed.

Blindness↗

Hearing preservation in acoustic neuroma surgery: value of monitoring cochlear nerve action potentials.

This study reviews the hearing results in 80 consecutive patients who underwent complete removal of histologically proven acoustic neuromas by use of the suboccipital approach. Of these, 56 patients had successful monitoring of cochlear compound action potentials; 20 were not monitored because their surgery predated monitoring; and 4 had unsuccessful monitoring. A significant difference was found in hearing preservation rates between the group in whom compound action potential monitoring was performed and those in whom monitoring was either unavailable or failed (p = 0.02). Overall, 38% (30 of 80) had preserved hearing. There were 51 patients in whom the click threshold for the cochlear compound action potential was measured during surgery. Twenty-one patients had a threshold shift of 20 dB or less, 15 (71%) of these retained serviceable hearing (speech reception threshold < or = 50 dB; speech discrimination score > or = 60%). Of 12 patients in whom the threshold shift was 30 to 60 dB, none had serviceable hearing after surgery. The click threshold shift was predictive of a significant postoperative hearing change (p < 0.001).

Action Potentials↗

The Australian Incident Monitoring Study. The pulse oximeter: applications and limitations--an analysis of 2000 incident reports.

The first 2000 incidents reported to the Australian Incident Monitoring Study were analysed with respect to the role of the pulse oximeter. Of these 184 (9%) were first detected by a pulse oximeter and there were a further 177 (9%) in which desaturation was recorded. Of the 1256 incidents which occurred in association with general anaesthesia 48% were "human detected" and 52% "monitor detected". The pulse oximeter was ranked first and detected 27% of these monitor detected incidents; this figure would have been over 40% if an oximeter had always been used and its more informative modulated pulse tone relied upon instead of that of the "bleep" of the ECG. The pulse oximeter is the "front-line" monitor for endobronchial intubation, the fourth most common incident in association with general anaesthesia (it detected 87% of the 76 cases in which it was in use). It also played an invaluable role as a "back-up" monitor in 40 life-threatening situations in which "front-line" monitors (e.g. oxygen analyser, low pressure alarm, capnograph) were either not in use, were being used incorrectly or failed. Other situations detected, in order of frequency of detection, were: circuit disconnection, circuit leak, desaturation (severe shunt), oesophageal intubation, aspiration and/or regurgitation, pulmonary oedema, endotracheal tube obstruction, severe hypotension, failure of oxygen delivery, hypoxic gas mixture, hypoventilation, anaphylaxis, air embolism, bronchospasm, malignant hyperthermia, and tension pneumothorax.(ABSTRACT TRUNCATED AT 250 WORDS)

Accidents↗

The Australian Incident Monitoring Study. The capnograph: applications and limitations--an analysis of 2000 incident reports.

The first 2000 incidents reported to the Australian Incident Monitoring Study were analysed with respect to the role of the capnograph. One hundred and fifty-seven (8%) were first detected by a capnograph and there were a further 18 (1%) in which capnography was contributory. Of the 1256 incidents which occurred in association with general anaesthesia 48% were "human detected" and 52% "monitor detected". The capnograph was ranked second and detected 24% of these monitor detected incidents; this figure would have been nearly 30% if a correctly checked, calibrated capnograph had always been used. The capnograph is a "front-line" monitor for oesophageal intubation, failure of ventilation, anaesthetic circuit faults, gas embolism, sudden circulatory collapse and malignant hyperthermia. It is a valuable "back-up" monitor when other monitors (e.g. low pressure alarm, pulse oximeter) are not in use, are being used incorrectly or fail. Such situations, in order of frequency of detection were: circuit-leak, overpressure of the breathing circuit, bronchospasm, leak of ventilator-driving-gas into the patient circuit, aspiration and/or regurgitation and hypoventilation. There were 20 reports of "failure", over two-thirds of which would not have occurred with appropriate checking and calibration. Seven were due to gas sampling problems and 6 to apnoea alarm failure. Two circuit leaks and 2 faulty unidirectional valves were not detected; on 3 occasions problems occurred due to power failure, calibration problems, or misinterpretation of an alarm.(ABSTRACT TRUNCATED AT 250 WORDS)

Accidents↗

The Australian Incident Monitoring Study. The stethoscope: applications and limitations--an analysis of 2000 incident reports.

The first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS) were analysed with respect to the role of the oesophageal or precordial stethoscope as a continuous monitor. There were 1099 of the 1256 incidents during general anaesthesia in which one might have been used in this way, but use was reported in only 65 cases (5%), predominantly during paediatric cases. In only one report, a cardiac arrest, was the stethoscope the first to detect the incident. In a theoretical analysis it was considered that the stethoscope, used on its own for continuous monitoring, could have detected 54% of the 1256 incidents (almost 25% before any potential for organ damage), had they been allowed to evolve. However, AIMS data suggest that the actual yield using a stethoscope as a continuous monitor may be much lower than this, and that even the use of a "mobile" stethoscope can not be relied upon to detect oesophageal or endobronchial intubation. These reports confirm that there is limited use of the stethoscope for continuous monitoring in current anaesthetic practice in Australia; it has been superseded by the sophisticated electronic monitors now available. However, in areas with limited resources continuous auscultation with a stethoscope remains a basic requirement.

Accidents↗

On-line monitoring of solutes in dialysate using absorption of ultraviolet radiation: technique description.

PURPOSE: The aim of this work was to describe a new optical method for monitoring solutes in a spent dialysate using absorption of UV radiation. METHOD: The method utilises UV-absorbance determined in the spent dialysate using a spectrophotometrical set-up. Measurements were performed both on collected dialysate samples and on-line. During on-line monitoring, a spectrophotometer was connected to the fluid outlet of the dialysis machine, with all spent dialysate passing through a specially-designed cuvette for optical single-wavelength measurements. The concentrations of several substances of various molecular sizes, electrical charge, transport mechanism, etc. were determined in the dialysate and in the blood using standard laboratory techniques. The correlation coefficient between UV-absorbance of the spent dialysate and concentration of the substances in the spent dialysate and in the blood was calculated from data based on the collected samples. RESULTS: The obtained on-line UV-absorbance curve demonstrates the possibility to follow a single hemodialysis session continuously and to monitor deviations in the dialysator performance using UV-absorbance. The experimental results indicate a very good correlation between UV-absorbance and several small waste solutes removed such as urea, creatinine and uric acid in the spent dialysate and in the blood for every individual treatment at a fixed wavelength of 285 nm. Moreover, a good correlation between the UV-absorbance and substances like potassium, phosphate and beta2-microglobulin was obtained. The lowest correlation was achieved for sodium, calcium, glucose, vitamin B12 and albumin. CONCLUSIONS: A technique for on-line monitoring of solutes in the spent dialysate utilising the UV-absorbance was developed. On-line monitoring during a single hemodialysis session exploiting UV-absorbance represents a possibility to follow a single hemodialysis session continuously and monitor deviations in dialysis efficiency (e.g. changes in blood flow and clearance). The UV-absorbance correlates well to the concentration of several solutes known to accumulate in dialysis patients indicating that the technique can be used to estimate the removal of retained substances.

Adult↗

AnyHeart: a single-piece heart-saving implantable artificial heart (BVAD)--monitoring and estimation.

AnyHeart is a single-piece, implantable biventricular assist device. This electromechanical BVAD has a moving-actuator mechanism. To monitor the status of AnyHeart from anywhere at any time, a portable personal digital assistant (PDA) monitor and web-based remote monitoring system were developed. The PDA local monitoring system has replaced bulky personal computer monitoring systems. The web-based remote monitoring system has several functions such as data collecting, storing, and posting through the internet. Basically, interventricular pressure (IVP) is a parameter indicating the filling level of the blood chambers of AnyHeart. The pump output can be estimated using IVP, which is acquired noninvasively from AnyHeart. With the proposed method, we can estimate the pump output with a small margin of error.

Computers, Handheld↗

Liver tumor cryoablation: a commentary on the need of improved procedural monitoring.

Cryoablation is a method used for in situ destruction of liver tumors not eligible for surgical resection. Local recurrences following such treatment have been reported at rates of 5-44%. Insufficient procedural monitoring of the ablation is one plausible explanation for these recurrences. The cryoablative procedure is usually monitored by ultrasonography, but acoustic shadowing and loss of signals, compromise visualisation of the cryolesion circumference. Other monitoring modalities such as computer tomography and invasive methods like the use of thermocouples and impedance measurements have also been studied, but are not in common clinical use as single monitoring modalities. Thermodynamic conditions assumed adequate for tumor eradication are likely to occur only in parts of the cryolesion. This tumoricidal part of the cryolesion is not adequately depicted using any of these modalities. Magnetic resonance imaging (MRI) provides a clear delineation of the cryolesion circumference. Noninvasive temperature measurements assisted by MRI indicate which parts of the cryolesion that may be subject to complete necrosis. In this article MRI monitored cryoablation of liver tumors is discussed. Improved peroperative monitoring as offered by MRI may reduce the rates of local recurrences after treatment, but further technological improvements are required.

Animals↗

Advances in ICP monitoring techniques.

With the advent of newer devices for measuring intracranial pressure (ICP) and cerebral metabolism, more alternatives continue to rise aiming to control ICP. This manuscript presents a proposed analysis of different ICP monitoring devices in order to make appropriate selection of them in our clinical setting including general and pediatric applications. A systematic review of the literature was made analyzing the technical advances in ICP monitoring. The recent in vitro and in vivo tests as well as mathematical/computer models were reviewed. Practical applications of principles were discussed and compared based on the mode of pressure transformation. A ventricular catheter connected to an external strain gauge transducer or catheter tip pressure transducer device is considered to be the most accurate method of monitoring ICP and enables therapeutic CSF drainage. The significant infections or hemorrhage associated with ICP devices causing patients morbidity are clinically rare and should not deter the decision to monitor ICP. Parenchymal catheter tip pressure transducer devices are advantageous when ventricular ICP cannot be obtained or if there is an obstruction in the fluid couple, though they have the potential for significant measurement differences and drift due to the inability to recalibrate. Subarachnoid or subdural fluid-coupled devices and epidural ICP devices are currently less accurate. With an increasing miniaturization of the transducers, fiberoptic systems have been developed, however, there is a problem of measurement accuracy during the period of patient monitoring and external calibration should be performed frequently to ensure constant accuracy. Ventriculostomies continue to have a pivotal role in ICP control. With a rational understanding of the applications and limitations of the different ICP monitoring devices, the outcome for critically ill neurological patients is optimized.

Animals↗

Clinical review: hemodynamic monitoring in the intensive care unit.

Since the beginning of modern anesthesia, in 1846, the anesthetist has relied on his natural senses to monitor the patient, aided more recently by simple technical devices such as the stethoscope. There has been a tremendous increase in the availability of monitoring devices in the past 30 years. Modern technology has provided a large number of sophisticated monitors and therapeutic instruments, particularly in the past decade. Most of these techniques have enhanced our understanding of the mechanism of the patients' decompensation and have helped to guide appropriate therapeutic interventions. As surgery and critical care medicine have developed rapidly, patient monitoring capability has become increasingly complex. The most important aspect in monitoring the critically ill patient is the detection of life-threatening derangements of vital functions. Aggressive marketing strategies have been promoted to monitor almost every aspect of the patient's status. However, these strategies are only telling us what is possible; they do not tell us whether they enhance patient safety, improve our therapy, or even improve patient outcome.

Blood Volume↗

Transesophageal Doppler cardiac output monitoring: performance during aortic reconstructive surgery.

Transesophageal Doppler (TED) monitoring provides continuous, noninvasive monitoring of cardiac output by measurement of aortic flow velocities. Because of the effects on aortic flow dynamics resulting from atherosclerosis, aortic cross-clamping, and wide variations in arterial blood pressure, the validity of TED monitoring during aortic surgery is unresolved. The authors prospectively evaluated a second-generation TED cardiac output monitor in 42 patients undergoing aortic reconstructive surgery. Four hundred eighty-nine simultaneous measurements of TED and thermodilution cardiac output were obtained. Transesophageal Doppler measurements were highly correlated to thermodilution measurements (R = 0.94); however, Bland-Altman analysis revealed a moderate error in the TED measurements (2 SD of the bias = 1.4 L/min). Trending analysis showed that TED monitoring accurately tracked changes in thermodilution cardiac output. Placement of an aortic cross-clamp resulted in significant reductions in the accuracy of Doppler measurements. Arterial blood pressure variations did not systematically affect the accuracy of the transesophageal technique. Limitations of TED monitoring, including a difficult calibration procedure, poor performance during aortic cross-clamping, and the need for probe repositioning, suggest further development is warranted.

Aorta, Abdominal↗

Capnography in non-tracheally intubated emergency patients as an additional tool in pulse oximetry for prehospital monitoring of respiration.

UNLABELLED: Victims of minor trauma transported by paramedic-based rescue systems are usually monitored with pulse oximetry. Under the difficult surroundings of prehospital trauma care, pulse oximeters show considerable periods of malfunction. We tested the hypothesis that capnography is a good, easy to use tool for monitoring in nonintubated trauma victims. Seventy nonintubated trauma victims were included in this study. Vital variables and number and time of malfunctions were sampled for oximeter and capnometer recordings. Total number of alerts (63 versus 10), number of alerts per patient (3.3 [1.9] versus 0.3 [0.9]) (mean [SD]), total time of malfunction (191.5 [216.7] s versus 11.8 [40.2] s), time of malfunction per alarm (58.3 [71.4] s versus 5.5 [14.6] s), and the percentage of malfunction time during transport (13.2% [15.3%] versus 0.8% [2.8%]) differed significantly (P < 0.01) between oximetry and capnography. Although pulse oximetry is a standard method of monitoring in emergency care, we found capnography to be helpful as a monitoring device. We consequently recommend the use of capnography on transport as an additional monitoring tool to reduce periods lacking supervision of the vital variables. IMPLICATIONS: Capnography is a useful tool to improve respiratory monitoring in nonintubated trauma victims on emergency transport and an easy to use supplement to pulse oximetry.

Adult↗

Narcotrend or bispectral index monitoring during desflurane-remifentanil anesthesia: a comparison with a standard practice protocol.

UNLABELLED: Bispectral Index (BIS) (Aspect Medical Systems, Newton, MA) and Narcotrend (MonitorTechnik, Bad Bramstedt, Germany) are monitoring devices that were, as others, designed to assess the depth of anesthesia. Meanwhile, a number of studies indicate that with total IV anesthesia, BIS and Narcotrend have comparable effects on drug consumption and recovery times whereas comparative clinical data for volatile anesthetics are still missing. Therefore, we designed the present prospective, randomized, and double-blinded study to compare the effects of BIS and Narcotrend monitoring during desflurane-remifentanil anesthesia and versus a standard anesthetic practice protocol. One-hundred-twenty adult patients scheduled for minor orthopedic surgery were randomized to receive a desflurane-remifentanil anesthetic controlled either by Narcotrend or by BIS or solely by clinical variables. Anesthesia was induced with 0.4 microg x kg(-1) x min(-1) remifentanil and 2 mg/kg propofol. After tracheal intubation, remifentanil was infused at a constant rate of 0.2 microg x kg(-1) x min(-1) whereas desflurane in 1.5 L/min O(2)/air was adjusted according to clinical variables or the following target values: during maintenance of anesthesia to a value of "D(0)" (Narcotrend) or "50" (BIS), 15 min before the end of surgery to "C(1)" (Narcotrend) or "60" (BIS), whereas in the standard protocol group, desflurane was controlled according to clinical variables, e.g., heart rate, arterial blood pressure, movements. Recovery times and desflurane consumption were recorded by a blinded investigator. The desflurane vaporizer was weighed before and after anesthesia and consumption per minute was calculated. Data are mean +/- sd. The groups were comparable for demographic data, duration of anesthesia, and mean remifentanil dosages. Compared with standard practice, patients with Narcotrend or BIS monitoring needed significantly less desflurane (standard practice 443 +/- 71 mg/min, Narcotrend 374 +/- 124 mg/min, BIS monitoring 416 +/- 99 mg/min desflurane [both P < 0.05]). However, recovery times were not significantly different between the groups, e.g., opening of eyes 4.7 +/- 2.2 versus 3.7 +/- 2.0 versus 4.2 +/- 2.1 min. During desflurane-remifentanil anesthesia, Narcotrend and BIS monitoring seem to be equally effective compared with standard anesthetic practice: BIS and Narcotrend allow for a small reduction of desflurane consumption whereas recovery times are only slightly reduced. IMPLICATIONS: Monitoring the electroencephalogram with Narcotrend or Bispectral Index during desflurane-remifentanil anesthesia only slightly reduces recovery times when compared with a standard practice protocol.

Adolescent↗

The usefulness of Holter monitoring in the evaluation of antiarrhythmic drug efficacy for tachycardia.

Using Holter monitoring tachycardia was found in 145 out of 2058 patients suffering from various underlying diseases. Three thousand seven hundred and forty monitorings were performed. The mean age of patients was 54.5 years with a range of 19 to 83 years. The observed tachycardia was classified into three types: tachycardia with short duration, tachycardia with long duration and tachycardia with complex form. The attacks of tachycardia were more frequently observed during periods of physical activity than during sleeping periods. The relationship of the number of tachycardia with short duration between 24-hour Holter monitorings was examined in order to establish day to day variability of the attacks. The 95% confidence interval about the resultant regression line was calculated and the percent reduction required for the evaluation of drug efficacy to avoid the chances of interference of spontaneous variation was found to be about 44.0, 55.0 and 82% when the total number of attacks during a 24-hour period were 50, 100 and 1,000, respectively. Holter monitoring showed higher positive results as compared to exercise testing for detection of tachycardia. Higher correlation coefficients between numbers of premature ventricular contractions (PVCs) and the plasma concentrations of procainamide or N-acetylprocainamide were observed in 3 or more successive PVCs than in individually occurring PVCs. Using repeated 24-hour Holter monitorings a significant reduction in the number of tachycardia was observed when the therapeutic concentration was reached after the combined or single administration of the drug. These results suggest that repeated Holter monitorings, exercise testing and determination of plasma level of the drug may be useful for the evaluation of antiarrhythmic drug efficacy for tachycardia.

Adult↗

Rhythm of daily living and detection of atypical days for elderly people living alone as determined with a monitoring system.

We have developed a system for monitoring the health of elderly people living at home. Infrared and other sensor outputs are collected using a monitoring program installed on a personal computer (PC) in the home at a sampling rate of 1 Hz. Once each day, the data are transferred to a server through the Internet using a cable television (TV) connection. An elderly subject was monitored for a 12-day baseline period and completed a daily questionnaire about her activities. This enabled us to identify the rhythm of daily living (sleeping, 23:00-04:59; getting up/breakfast, 05:00-08:59; indoor activities/going out, 09:00-16:59; and dinner/going to bed, 17:00-22:59) and the average outputs from the sensors in the rooms. The subject was then monitored for a further six months. By identifying sensor output counts outside the limits of mean +/- 3SD, we were able to detect atypical days. During the six-month monitoring period, 29 atypical days were detected. We suggest that the monitoring system may be effective in tele-rehabilitation.

Activities of Daily Living↗

[The study of biological monitoring of inorganic arsenic exposure].

This review will describe method for biological monitoring of inorganic arsenic exposure, that delineates the chemical species of arsenic measured in urine. The studies established a method for exposure-level-dependent biological monitoring of inorganic arsenic exposure. Low-level exposure could be monitored only by determining the urinary inorganic arsenic concentration. High-level exposures clearly produced increased urinary inorganic arsenic, methylated arsenic (MA), dimethylated arsenic (DMA) and the sum of urinary inorganic arsenic and its metabolites (inorganic arsenic+MA+DMA) could be determined. Urinary arsenobetaine proved to be specifically seafood-derived arsenic, which could be distinguished from occupational arsenic exposure. There is increased use of gallium arsenide and indium arsenide in the semiconductor industry today. The determination of arsenic in ambient air is difficult to carry out in semiconductor factories. Monitoring arsenic exposure by determining the arsenic in the hair appeared to be of value only when used for environmental monitoring of arsenic rather than for biological monitoring.

Arsenic↗

Intraoperative monitoring of auditory function: experimental observations and new applications.

The three different methods of intraoperative monitoring, namely, auditory brainstem response evaluation (ABR), electrocochleography (ECoG), and direct eighth nerve compound action potentials monitoring are reviewed. Both ECoG and direct eighth nerve monitoring surpass the ABR in their ability to provide fast, almost instantaneous, large, reproducible potentials in response to click stimuli. Changes in the amplitude and the latency of these potentials alert the surgeon of an impending eighth nerve injury. Human clinical observations revealed instances of persistence of the ECoG despite a total eighth nerve section in the cerebellopontine angle. Animal and human experiments were conducted to evaluate the effectiveness of ECoG and direct eighth nerve monitoring in hearing preservation. Twelve cats underwent progressive sectioning of the eighth nerve with simultaneous monitoring of changes in their ECoG and direct eighth nerve potentials. ECoG thresholds were obtained intraoperatively in eight patients undergoing surgery for conductive hearing loss. The results of these experiments suggest that recording directly from the eighth nerve is a more accurate technique during cerebellopontine angle and eighth nerve surgery. ECoG, however, appears to have a promising role in the intraoperative monitoring of middle ear reconstruction procedures under general anesthesia.

Action Potentials↗

State monitoring activities related to Pfiesteria-like organisms.

In response to potential threats to human health and fish populations, six states along the east coast of the United States initiated monitoring programs related to Pfiesteria-like organisms in 1998. These actions were taken in the wake of toxic outbreaks of Pfiesteria piscicida Steidinger & Burkholder in Maryland during 1997 and previous outbreaks in North Carolina. The monitoring programs have two major purposes. The first, rapid response, is to ensure public safety by responding immediately to conditions that may indicate the presence of Pfiesteria or related organisms in a toxic state. The second, comprehensive assessment, is to provide a more complete understanding of where Pfiesteria-like organisms may become a threat, to understand what factors may stimulate their growth and toxicity, and to evaluate the impacts of these organisms upon fish and other aquatic life. In states where human health studies are being conducted, the data from both types of monitoring are used to provide information on environmental exposure. The three elements included in each monitoring program are identification of Pfiesteria-like organisms, water quality measurements, and assessments of fish health. Identification of Pfiesteria-like organisms is a particularly difficult element of the monitoring programs, as these small species cannot be definitively identified using light microscopy; newly applied molecular techniques, however, are starting to provide alternatives to traditional methods. State monitoring programs also offer many opportunities for collaborations with research initiatives targeting both environmental and human health issues related to Pfiesteria-like organisms.

Animals↗