PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Robotics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96Linked to original sources

Robotic magnetic navigation for atrial fibrillation ablation.

OBJECTIVES: We assessed feasibility of magnetic catheter guidance in patients with atrial fibrillation (AF) undergoing circumferential pulmonary vein ablation (CPVA). BACKGROUND: No data are available on feasibility of remote navigation for AF ablation. METHODS: Forty patients underwent CPVA for symptomatic AF using the NIOBE II remote magnetic system (Stereotaxis Inc., St. Louis, Missouri). Ablation was performed with a 4-mm tip, magnetic catheter (65 degrees C, maximum 50 W, 15 s). The catheter tip was guided by a uniform magnetic field (0.08-T), and a motor drive (Cardiodrive unit, Stereotaxis Inc.). Left atrium maps were created using an integrated CARTO RMT system (Stereotaxis Inc.). End point of ablation was voltage abatement >90% of bipolar electrogram amplitude. RESULTS: Remote ablation was successful in 38 of 40 patients without complications. The median mapping and ablation time was 152.5 min (range, 90 to 380 min) but was much longer in the first 12 patients (192.5 min vs. 148 min; p = 0.012). Median ablation time was 49.5 min (range, 17 to 154 min), but it was much shorter in the last 28 patients than in the first 12 patients (49 min vs. 70 min; p = 0.021). Patients receiving remote ablation had longer procedure times than control patients (p < 0.001) with similar mapping time but shorter ablation time on right-sided pulmonary veins. Many more mapping points regardless of their location were collected remotely (p < 0.001). CONCLUSIONS: Remote magnetic navigation for AF ablation is safe and feasible with a short learning curve. Although all procedures were performed by a highly experienced operator, remote AF ablation can be performed even by less experienced operators.

Adult↗

Ethanol analysis from biological samples by dual rail robotic autosampler.

Detection, identification, and quantitation of ethanol and other low molecular weight volatile compounds in liquid matrices by headspace gas chromatography-flame ionization detection (HS-GC-FID) and headspace gas chromatography-mass spectrometry (HS-GC-MS) are becoming commonly used practices in forensic laboratories. Although it is one of the most frequently utilized procedures, sample preparation is usually done manually. Implementing the use of a dual-rail, programmable autosampler can minimize many of the manual steps in sample preparation. The autosampler is configured so that one rail is used for sample preparation and the other rail is used as a traditional autosampler for sample introduction into the gas chromatograph inlet. The sample preparation rail draws up and sequentially adds a saturated sodium chloride solution and internal standard (0.08%, w/v acetonitrile) to a headspace vial containing a biological sample, a calibrator, or a control. Then, the analytical rail moves the sample to the agitator for incubation, followed by sampling of the headspace for analysis. Using DB-624 capillary columns, the method was validated on a GC-FID and confirmed with a GC-MS. The analytes (ethanol, acetonitrile) and possible interferences (acetaldehyde, methanol, pentane, diethyl ether, acetone, isopropanol, methylene chloride, n-propanol, and isovaleraldehyde) were baseline resolved for both the GC-FID and GC-MS methods. This method demonstrated acceptable linearity from 0 to 1500 mg/dL. The lower limit of quantitation (LOQ) was determined to be 17 mg/dL and the limit of detection was 5 mg/dL.

Biomarkers↗