PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “THROMBOPLASTIN”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,729 records · Page 96Linked to original sources

Therapeutic heparin monitoring service in a small community hospital.

Upon the request of members of the medical staff, the Pharmacy and Therapeutics Committee at Tawas St. Joseph Hospital began monitoring patients receiving full-dose continuous intravenous heparin therapy. Problems were noted in the usage of activated partial thromboplastin times and the resultant changes in heparin therapy. The problems identified during this quality assurance activity were addressed by a heparin protocol developed by a clinical pharmacist. The protocol includes giving patients a heparin loading dose of 50-100 units/kg actual body weight, an initial infusion rate of 15-20 units/kg/hr, and drawing the first activated partial thromboplastin time 6 hours later. After the results of the activated partial thromboplastin times are known, the protocol provides for further patient management and changes in infusion rates, if needed. A review of the heparin protocol use at 6 months after initial implementation, and 6 months after minor changes in the protocol, showed that clinical pharmacists improved heparin therapy in the patients they treated. Pharmacists used larger initial continuous infusion rates, less activated partial thromboplastin times during treatment, and patients they managed reached therapeutic activated partial thromboplastin time ranges earlier than patients treated by physicians. When voluntarily prescribed by physicians, full-dose continuous intravenous heparin therapy initiated and monitored by clinical pharmacists improved the quality of patient's anticoagulation treatment during hospitalization.

Clinical Protocols↗

[A study of intrapartum and postpartum bleeding based on changes in blood coagulation and fibrinolysis during pregnancy].

The relationship between changes in blood coagulation and fibrinolysis during pregnancy and intrapartum-postpartum bleeding was studied as a trial prediction of abnormal bleeding during vaginal delivery in 27 subjects without any complications. The following results were obtained: In the third trimester, shortening of prothrombin time and activated partial thromboplastin time, increases in fibrinogen, platelet epinephrine, collagen aggregation, and plasminogen, and a decrease in alpha 2-plasmin inhibitor were marked as compared with those in the first trimester. In the same subjects, the relationship between changes in blood coagulation and fibrinolysis in the first and third trimesters and intrapartum-postpartum bleeding was studied by the independent matched pair test. There were significant correlations (p less than 0.005, p less than 0.001) between prothrombin time (r = -0.68862) and activated partial thromboplastin time (r = -0.77027). In the subjects whose prothrombin time and activated partial thromboplastin time in the third trimester were shorter than those in the first trimester, intrapartum and postpartum bleeding increased. The subjects whose prothrombin time and activated partial thromboplastin time in the third trimester were less by more than 0.52 seconds and more than 3.98 seconds, respectively, than those in the first trimester experienced abnormal bleeding exceeding 500 ml during delivery. In the intrapartum and postpartum bleeding group, shortening of prothrombin time and activated partial thromboplastin time, decreases in fibrinogen and alpha 2-plasmin inhibitor and an increase in platelet aggregation were more significantly observed than in the intrapartum and postpartum normal bleeding groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Antithrombin III↗

Reliability and clinical impact of the normalization of the prothrombin times in oral anticoagulant control.

In 1983, the World Health Organization (WHO) published recommendations for normalization, in oral anticoagulant control, of the prothrombin time (PT). The common denominator is the International Sensitivity Index (ISI) of a thromboplastin, obtained by means of thromboplastin calibration. The common scale is that of the International Normalized Ratio (INR). The INR is the PT ratio (Formula: see text) which would have been found with the WHO primary international reference preparation (IRP) 67/40. The reliability of the INR depends on the extent of calibration precision, patient-specific influences, as well as inter-laboratory variation in the PT determination. Under well-controlled conditions the overall coefficient of variation (CV) of the INR is 11-13.5%, if thromboplastins of ISI congruent to 1 are used. For so-called low-sensitivity thromboplastins (ISI congruent to 2-2.5), the overall variation is larger due to a large between-laboratory variation of the measured PT-ratios. The user of thromboplastin will be provided with a chart or graph enabling him to convert the conventional terms used for expressing PTs into INRs. For quality assurance, and to prepare his own calibration chart if necessary, he should check normalization by means of control plasmas to which INRs have been assigned. There is sufficient clinical evidence to express optimal therapeutic ranges in terms of INR. Manufacturers should revise and adapt their inserts where necessary in order to conform to these requirements.

Administration, Oral↗

Hereditary factor VII deficiency: heterogeneity defined by combined functional and immunochemical analysis.

Twenty-six patients with hereditary factor VII deficiency (VII:C less than 10%) were evaluated using a panel of three thromboplastins of varying species and tissue origin in both coagulant and chromogenic assay systems. Normal values for the coagulation and chromogenic assays were 104% +/- 7% and 108% +/- 21%, respectively. Factor VII antigen was measured by a specific radioimmunoassay (normal, 470 +/- 112 ng/mL). The patients were divided into two groups based on the factor VII:Ag assay results. Group 1, 18 patients, had decreased levels of factor VII:Ag and group 2, eight patients, had normal levels of factor VII:Ag. The two groups were further subdivided on the basis of discrepant factor VII:C levels in the chromogenic and coagulant assays. The number of observed patterns of functional factor VII:C activity suggests a high degree of complexity of factor VII and thromboplastin interaction. Whereas no clinical bleeding was reported in any of the nine black patients evaluated, all Caucasians (16) and one Hispanic presented with mild to severe bleeding. Patients with factor VII:C greater than 10% using a human thromboplastin had a negative bleeding history, regardless of the activity measured with other thromboplastins. Factor VII activity measured with a human thromboplastin appears to correlate best with the clinical picture.

Adolescent↗

[Simultaneous determination of zymogen activation time and zymogen level using chromogenic substrates in blood coagulation analysis].

The amidolytic activities of plasma generated by means of thromboplastin and Ca++, on the one hand, and by means of partial thromboplastin, a contact activator and Ca++, on the other hand, were determined using synthetic, chromogenic factor Xa substrates with low affinity for thrombin (CH3SO2-D-Leu-Gly-Arg-pNA and CH3SO2-D-Nleu-Gly-Arg-pNA). In this way, the activation process by splitting off the p-nitroaniline was followed. Besides the summary detection of factor Xa was obtained after addition of hirudin. During preincubation with partial thromboplastin and contact acti (Actin) in Ca++-free medium, an amidolytic activity so far unidentified was generated that renders evaluation of the activation process difficult. In the test system with partial thromboplastin, factor Xa could not be determined and the thrombin-like activity that can be inhibited by hirudin did not correspond to the amount of prothrombin present in plasma. In contrast, activation of factor X and prothrombin by thromboplastin and Ca++ could be followed and the content of the two zymogenes could be detected simultaneously. In general, under optimized reaction conditions, automated systems might be developed that would provide additional diagnostic information about determination of clotting time, on the one hand, and about quantitative determination of zymogen, on the other hand.

Calcium↗

[Evaluation of the quality of prothrombin time technique in the Basque Country].

PURPOSE: The Programme for Quality Assessment in Anticoagulant Therapy, which was started in the Basque Country in 1984, included the manufacturing of a standard human thromboplastin reagent plus periodical quality controls of the prothrombin time. A rabbit thromboplastin reagent was available in 1994; it was called Thromboplastin Bilbao, or TBi, and had to be used as a pattern reagent. Its stability, sensitivity and composition were plotted against the Manchester Reagent, of similar nature and composition. A new phase of quality quality controls was simultaneously started with this new reagent, a group of hospitals of the Autonomous Community taking part in the programme. The aim was to compare this reagent with the others used by the hospitals and to evaluate the variations with regard to the stages previous to the introduction of the human reagent. MATERIAL AND METHODS: Nine centres joined the study. Controls were performed every fourth month including plasma from patients under anticoagulant treatment, plus the reference reagents. The partaking centres used their usual reagents and routine procedures, as well as the reference reagents and manual technique. RESULTS: The coefficient of variation (CV) of the INR of anticoagulated plasmas used for these studies when following the centres' own methods and thromboplastins was 9.5 +/- 6.40%, versus 9.94 +/- 1.57% when TBi was used. These results are in accordance with those attained with the previously manufactured human reagent, whose CV was 8.75 +/- 2.19% in the quality assurance methods performed in the period 1984-88. Concurrently with the programme, the reagent was sent as a part of the Spanish Programme for Quality Assessment in Anticoagulant Treatment to the 51 centres taking part in the study. The CV of the INR of the two lyophilized plasmas sent was, respectively, 14.97% and 16.5%. The average value for the healthy subjects was 14.77 seconds, with 8% inter-centres variation when using manual methods. CONCLUSIONS: These results suggest that a thromboplastin is now available whose sensitivity and reproducibility make it suitable as the national standard for usage in the quality assessment of prothrombin time.

Animals↗

Screening and diagnosis of coagulation disorders.

After clinical assessment, pertinent history, and family history, the clinician often has a good idea concerning the cause of a patient's bleeding. The most appropriate laboratory tests can then be ordered. Routine screening tests include a complete blood cell count, platelet count, and evaluation of a peripheral blood sample, a prothrombin time, and an activated partial thromboplastin time. Thrombocytopenia may result from idiopathic thrombocytopenic purpura, disseminated intravascular coagulation, or, less commonly, acute leukemia, aplastic anemia, thrombotic thrombocytopenic purpura, or a particular drug that a patient is taking. Again, the patient's history, physical findings, and evaluation of a well-prepared peripheral blood smear will be helpful in determining the cause of the patient's thrombocytopenia. An isolated prolongation of the activated partial thromboplastin time may result from low levels of factors VIII, IX, or XI. A slightly prolonged activated partial thromboplastin time and a moderate decrease in factor VIII may reflect von Willebrand disease or the "carrier" state for hemophilia A. In women a greatly prolonged activated partial thromboplastin time and very low levels of factor VIII (< 3%) most often result from an acquired factor VIII inhibitor (autoantibody against factor VIII) or from severe (type III) von Willebrand disease. If von Willebrand disease is suspected (because of menorrhagia with or without other mucous membrane bleeding, a positive family history, and a prolonged activated partial thromboplastin time), more specific laboratory tests for this disease should be done. These include assays of factor VIII, von Willebrand factor antigen, von Willebrand factor activity (measured by the ristocetin cofactor assay), and template bleeding time. In von Willebrand disease the defect is in von Willebrand factor. The affected individual may have subnormal levels of structurally and functionally normal von Willebrand factor (this is called "classic" or type I von Willebrand disease) or may produce von Willebrand factor that is structurally and functionally abnormal (von Willebrand disease type 2). Individuals who inherit a gene for von Willebrand disease from both parents have severe (type 3) von Willebrand disease and will have extremely low levels (< 3%) of von Willebrand factor and factor VIII and will have a very prolonged bleeding time. In most populations type I disease is the most common form, whereas type 3 is the least commonly encountered form. It should be noted that levels of von Willebrand factor can be influenced by the patient's blood type (persons who have blood type AB have 60% to 70% higher levels than do persons who have blood type O) and can be elevated during pregnancy, stress, and hyperthyroidism. The two major functions of von Willebrand factor are to serve as a "bridge" between platelets and injury sites in blood vessel walls and to protect circulating factor VIII from rapid proteolytic degradation. Thus, if a patient has either too little or functionally abnormal von Willebrand factor, the bleeding time will be prolonged and factor VIII will be decreased (because it is not being protected by von Willebrand factor). It should be determined which type of von Willebrand disease a particular patient has because treatment depends on type. Multimeric analysis of von Willebrand factor can be done with use of sodium dodecyl sulfate gels, radiolabeled antibody to von Willebrand's factor, and autoradiography. This will allow visualization of the multimeric structure of von Willebrand factor. In type I disease all bands are present, whereas in the type 2 variants 2A and 2B no high-molecular-weight multimers are seen. Desmopressin acetate (which is available in parenteral form for intravenous use and in a highly concentrated intranasal spray formulation) is the treatment of choice for classic type I disease. The drug effects a rapid release of von Willebrand factor from endothelial cell stor

Blood Coagulation Disorders↗

Clinically significant differences in the International Normalized Ratio measured with reagents of different sensitivities. SPAF Investigators. Stroke Prevention in Atrial Fibrillation.

The International Normalized Ratio (INR) system was introduced a decade ago as a way of standardizing the results of prothrombin time testing for patients taking oral anticoagulants. A strong emphasis has been placed upon using thromboplastin reagents that are very sensitive to the effects of oral anticoagulants upon the prothrombin time [i.e. reagents with low International Sensitivity Index (ISI)]. In order to assess how well the INR system functions as currently used in clinical laboratories, we compared the INRs determined using thromboplastins of differing ISIs in samples collected during a large clinical trial of oral anticoagulation for atrial fibrillation (Stroke Prevention in Atrial Fibrillation III trial). Frozen plasma was subjected to prothrombin time testing using thromboplastins with ISIs ranging from 0.97 to 2.49. INRs were calculated using machine-specific ISIs and Westgard's rules were followed to maintain quality control. An unanticipated coagulometer failure allowed a determination of the effect of machine recalibration upon the INR of control plasmas. The correlation between each pair of INRs obtained from 1181 plasmas was high (> 0.9), but the differences between reagents were statistically different from zero (P<0.001 for pairwise comparisons). Plasmas had INRs within the therapeutic range (2.0-3.0) with one reagent but not with another in an average of 20% of instances. Among the 20% discordant pairings, 43% (8.5% of the total tested) showed a difference in INR of more than 0.2 INR units above or below the target range. Low ISI thromboplastins did not perform better in this pairwise comparison than other reagents or the locally determined INR. Recalibration of a coagulometer resulted in a significant change in the INRs obtained from control plasmas (P<0.0001), which confirms and extends the observations of other authors concerning the sensitivity of the INR to coagulometer-related variables. There was a clinically significant difference in the INRs obtained with different thromboplastins, and low ISI reagents did not perform better than others. Since the risk of thrombosis rises sharply below the lower limit of the currently recommended target ranges, consideration should be given to narrowing the recommended range, or advising clinicians to aim for its mid-point. These findings illustrate the difficulties in imposing standardization upon coagulation testing after a test is in widespread use.

Administration, Oral↗

Alteration in the laboratory profile of a lupus anticoagulant in a patient with non-Hodgkin's lymphoma.

We describe a patient with non-Hodgkin's lymphoma who developed a lupus anticoagulant (LA) detectable by activated partial thromboplastin time (APTT), dilute Russell's viper venom time (DRVVT) and kaolin clotting time (KCT). IgM anticardiolipin antibodies (ACA) were elevated. At a later admission, and following treatment for the lymphoma, routine coagulation screening showed an elevated prothrombin time (PT) without correction in mixing tests using a recombinant thromboplastin. Routine APTT was below the reference range and ACA levels were normal. Raw data for one-stage factor assays demonstrated the presence of an inhibitor. Analysis for LA was undertaken by DRVVT, KCT, activated seven lupus anticoagulant assay, Taipan snake venom time, platelet neutralisation procedures (PNP), Ecarin time and PT using rabbit brain thromboplastin. The results revealed a LA capable of prolonging the clotting times of the PNPs and PT using recombinant thromboplastin, but that was corrected using Ecarin venom, modified PNP and brain thromboplastin. The antibody also demonstrated the lupus anticoagulant co-factor effect. The factor VIII: C was markedly raised which may have masked the LA in the APTT. The changing laboratory profile over time demonstrates the effects of LA heterogeneity and variations in sensitivity and specificity of assays for the detection of antiphospholipid antibodies.

Aged↗

Evaluation of a prothrombin time optimized for the dog on plasmas with defined coagulation factor deficiency due to coumarin intoxication.

The sensitivity of the standard prothrombin time (PT) was low when measured on 56 plasmas with a reduced activity of the coagulation factors mainly of the prothrombin complex (factors II, VII and/or X) taken from eight dogs at different times of vitamin K1 therapy after coumarin intoxication. This was demonstrable by use of three different Ca-thromboplastins. With the standard test only plasmas with an excessive decrease of coagulation factor activity (sum of activity decrease of the single factors in relation to the respective reference range [SAD] > 100%) were detectable with sufficient reliability. In contrast, by using a method optimized for dogs (1:20 sample predilution, fibrinogen substitution) and respecting the species specific features of coagulation physiology, pathological PT-values were measured in up to 70% of the samples (dependent on the Ca-thromboplastin) with slight reductions of single factor activity (SAD: 11-25%). Significant differences concerning the sensitivity were seen additionally between the different Ca-thromboplastins. Human placenta thromboplastin in particular, but also rabbit brain thromboplastin, were more sensitive than a preparation of recombinant human tissue factor. The correlation between the PT and the SAD was closer when using the optimized method (r = 0.919-0.954) compared to the standard test (r = 0.771-0.862). In contrast to the standard test, the PT optimized for dogs is, therefore, a reliable screening test to recognize a slight reduction in prothrombin complex. It is especially suitable for monitoring of vitamin K1 therapy after coumarin intoxication.

Animals↗

The effects of freeze drying and freeze drying additives on the prothrombin time and the international sensitivity index.

AIM: To determine whether freezing, freeze drying protective additives, or freeze drying of plasma samples from patients on coumarin treatment and from normal individuals affects prothrombin times or the international sensitivity index (ISI) calibration. METHODS: The effect of the addition of the protective additives singly and combined on the prothrombin time of coumarin samples and normal samples before and after freeze drying was observed using high and low ISI reference thromboplastins. ISI values were also determined. RESULTS: Freezing caused a prolongation of prothrombin time in the normal plasma samples with both reagents, which was significant with the low ISI human. Prolongation (non-significant) of the prothrombin time in coumarin plasma samples occurred with the human reagent only. Significant prolongation of normal prothrombin time by some of the protective additives before and after freeze drying was observed with both thromboplastins but to a greater extent with the human. Significant prolongation of prothrombin time in coumarin plasma samples was observed, but again was more marked with human thromboplastin. An approximate ISI was determined on the 20 coumarin samples. The only marked ISI change was with the WHO human thromboplastin after freeze drying of plasma, where a decrease from 0.95 to 0.90 was observed, corresponding to a marked prothrombin ratio increase. CONCLUSIONS: Freeze drying additives and the freeze drying procedure prolong normal and coumarin prothrombin times, with low ISI thromboplastin. Less marked prolongations occurred with a high ISI rabbit reagent, coumarin samples showing more significant prolongations. Marked ISI change in freeze dried plasma was only recorded with the low ISI ECAA human reagent. Frozen normal plasma samples cannot be used with confidence for ISI calibrations.

Animals↗

Factor VIIShinjo: a dysfunctional factor VII variant homozygous for the substitution Gln for Arg at position 79.

We report a factor VII (FVII) variant, FVIIShinjo, characterized by normal FVII antigen levels and variable procoagulant activity using tissue thromboplastin from different sources. Normal FVII activity is obtained using human placenta thromboplastin but low activity using rabbit or bovine brain thromboplastin. Exons 2-8 and the intron-exon junctions of the FVII genes of the propositus were amplified by PCR from DNA extracted from peripheral white blood cells, and screened by single-strand conformational polymorphism (SSCP) analysis. DNA fragments showing aberrant mobility were cloned and sequenced. We detected a single-point mutation, a homozygous G to A transition at nucleotide position 6,055 in exon 4, which results in the substitution of Arg 79 by Gln in the first EGF-like domain. This mutation results in a loss of a site for the restriction endonuclease MspI. The Msp I digestion pattern of the PCR-amplified exon 3+4 fragments from each member of the family was determined. The Msp I haplotypes were consistent with this G to A transition being associated with reduced FVII activity as detected using thromboplastins from various species. We conclude that the Arg 79 to Gln substitution in the first EGF-like domain of FVII identified in the propositus is responsible for the inherited FVII abnormality in this Japanese family. We postulate that one of the sites of interaction between FVII and tissue thromboplastin includes Arg 79 in the first EGF-like domain of factor VII.

Base Sequence↗

Warfarin and the international normalized ratio: reducing interlaboratory effects.

In North America, the dose of warfarin has been unintentionally increased during the past two decades because of failure to recognize the effect on the anticoagulation test of less sensitive tissue thromboplastins. Although there still is some controversy, the suggested dose of warfarin has now been adjusted downward to reduce the risk of bleeding. These revised dosing recommendations incorporate the international normalized ratio (INR), which takes into account the source of thromboplastin. However, there is considerable variability in the sensitivities of thromboplastin from manufacturer to manufacturer and lot to lot. Therefore, prothrombin times (PTs) are not comparable from laboratory to laboratory without knowing the sensitivity of the thromboplastin. Unless laboratories adopt a standardized tissue thromboplastin, the PT should be reported as an INR.

Humans↗

Influence of time and temperature on coagulation analytes in stored plasma.

There is no comprehensive study on the stability of coagulation analytes in plasma. We therefore determined the influence of storage time and temperature on prothrombin time, activated partial thromboplastin time, thrombin time, fibrinogen, factors V and VIII, antithrombin III, protein C and S in plasma from 20 healthy subjects and 20 patients receiving heparin therapy. The stability in plasma, defined as the period during which there was a change of less than 10% from the initial value, was 8 hours for activated partial thromboplastin time, 24 hours for prothrombin time, 48 hours for factor V and 7 days for thrombin time, fibrinogen, protein C and antithrombin III in healthy subjects at 6 degrees C. Factor VIII and protein S showed 19 and 12 % reduction in activity, respectively, after 8 hours. In volunteers not treated with heparin therapy, activated partial thromboplastin time was stable for 8 hours; prothrombin time for 48 hours; and thrombin time, fibrinogen and antithrombin III for 7 days with sample storage at room temperature. Factor VIII showed a decrease of 18 % after 8 hours. For patients receiving heparin therapy, the stability of the analytes in plasma stored at 6 degrees C was 8 hours for thrombin time, 24 hours for prothrombin time and activated partial thromboplastin time and 7 days for fibrinogen and antithrombin III. Factors V and VIII showed a decrease of 13 % and 20 % respectively after 8 hours. When the plasma of these patients was stored at room temperature, factor V was stable for 8 hours, and prothrombin time for 24 hours, whereas fibrinogen and antithrombin III remained unchanged for 7 days. Activated partial thromboplastin time showed an increase of 13 %, thrombin time a fall of 16 %, and factor VIII a decrease of 18 % after 8 hours.

Blood Coagulation↗

Accuracy of laboratory and portable monitor international normalized ratio determinations. Comparison with a criterion standard.

BACKGROUND: Portable instruments that measure the prothrombin time and automatically calculate the international normalized ratio (INR) with the use of a drop of whole blood have simplified the treatment of patients who are receiving warfarin therapy. The accuracy of these portable monitors has never been determined by comparing INR results with a criterion (gold) standard INR determination. METHODS: Duplicate whole-blood INR determinations were made with two commercially available portable INR monitors. Duplicate frozen-plasma samples were measured with four different thromboplastin reagents, each with a different international sensitivity index. The criterion standard INR was determined by using an international reference thromboplastin and the manual tilt-tube technique. Agreement was evaluated by determining how accurately laboratory and monitor INR determinations matched criterion standard values in designating a sample to be within or outside of currently recommended INR target ranges. RESULTS: Two of the laboratory methods, which used relatively sensitive thromboplastins, showed close agreement with the criterion standard, whereas two laboratory methods that used less sensitive thromboplastin reagents showed poor agreement. Both of the portable monitors fell between these extremes. The two best laboratory methods ere significantly better (P < .003) than both monitors, which in turn were better (P < .003) than the remaining two laboratories. CONCLUSIONS: There is large interlaboratory variation in the accuracy of INR determinations. Laboratory methods that used insensitive (high international sensitivity index) thromboplastins performed poorly. Accuracy of monitor measurements appears satisfactory.

Adult↗

Sensitivity and specificity of fluid-blood levels for coagulopathy in acute intracerebral hematomas.

PURPOSE: To characterize the imaging features of intracerebral hemorrhages in coagulopathies that alter prothrombin time or partial thromboplastin time. METHODS: A fluid-blood level was defined as a horizontal interface between hypodense bloody serum layered above hyperdense settled blood. The prevalence of fluid-blood levels in acute intracerebral hemorrhages was determined on third-generation CT scans in 32 patients with elevation in prothrombin time or partial thromboplastin time. This was compared with the frequency of fluid-blood levels in 185 patients with intracerebral hemorrhage in which there was no laboratory evidence of coagulopathy. RESULTS: The probability of finding a fluid-blood level in an intracerebral hemorrhage of a patient with abnormal prothrombin time or partial thromboplastin time was 59% (sensitivity). The probability that there will be no fluid-blood level in a patient with a normal prothrombin time and partial thromboplastin time was 98% (specificity). CONCLUSION: Fluid-blood levels in acute intracerebral hemorrhage are moderately sensitive to the presence of coagulopathy (ie, abnormal prothrombin time and partial thromboplastin time) and highly specific for this condition. Thus, an intracerebral hemorrhage with a fluid-blood level should prompt a thorough search for coagulopathy because early treatment of this condition may improve the 40% mortality in these patients. Caution should be used to distinguish the horizontal interface of a fluid-blood level from a clot with a flat top. A decubitus CT is useful in these rare instances.

Aged↗

Local calibration of international normalised ratio improves between laboratory agreement: results from the UK National External Quality Assessment Scheme. UK NEQAS (Blood Coagulation) Steering Committee.

In the present study we have performed local calibration of International Normalised Ratio (INR) measurement systems in a large series of laboratories. We assigned INRs to five lyophilised plasma calibrants, one prepared from normal plasma and four using plasma from warfarinised patients, using different International Reference Preparations for Thromboplastin. These five calibrants, and two lyophilised test plasmas were analysed by 349 centres using 60 different thromboplastin instrument combinations. Plasma calibrants were assigned INRs using the WHO reference thromboplastin RBT-90 or the European reference thromboplastin CRM 149R. Each participating centre determined PTs of the calibrants with their local system. These PTs were then used to construct a local calibration graph relating PT to INR. The PTs of test plasmas were converted directly into INR using the local calibration model and into INR using the conventional method. The overall medians of conventionally derived INRs of two test plasmas analysed in 349 centres were 2.50 and 3.10, compared to 2.47 and 3.04 after local calibration where RBT-90 was employed to assign INRs to calibrants. Use of CRM 149R to assign INRs to calibrants led to a significant (p<0.0001) increase in INR to 2.7 and 3.36 respectively. When results were grouped according to the thromboplastin employed, agreement between results with different reagents was improved by local calibration. There was a significant reduction (p<0.01) in the spread of results in different centres as indicated by a reduction in coefficient of variation.

Blood Coagulation↗

The laboratory diagnosis of lupus anticoagulants.

With the well-documented association of lupus anticoagulants with thrombotic disease and recurrent spontaneous abortion, the laboratory approach to diagnosing these inhibitors is more critical now. To this end, we examined plasma samples from 21 patients who initially presented with a prolonged prothrombin time or activated partial thromboplastin time or both for the presence of lupus anticoagulants. We used a battery of coagulation tests, including both immediate and two-hour mixing studies, a platelet neutralization procedure, a tissue thromboplastin inhibition test, and dilute Russell viper venom times. Two patients (10%) had only a prolonged prothrombin time, seven (33%) had only a prolonged activated partial thromboplastin time, and in 12 (57%) both were abnormal. In 15 patients, inhibition was evident on immediate assay of equal-volume mixture studies of patient plasma and normal pooled plasma, but in three additional patients it was evident only after a two-hour incubation. Fifteen of 18 samples showed correction of the abnormal screening study when platelets were used as a source of phospholipid. Both the tissue thromboplastin inhibition test and dilute Russell viper venom times were sensitive assays, being abnormal in 20 of 21 and 13 of 14 samples, respectively. In four patients, discordance of studies necessitated specific coagulation factor levels being measured to confirm the presence of the inhibitor. Because of the variable effect of the inhibitors on all currently available assay procedures, we would suggest that any evaluation will require a laboratory to have a battery of tests available before such an inhibitor can be excluded.

Adolescent↗