At least 1,747 records · Page 97Linked to original sources

Compliance of abdominal aortic aneurysms evaluated by tissue Doppler imaging: correlation with aneurysm size.

OBJECTIVES: Several studies have shown that an increase in abdominal aortic aneurysm (AAA) growth rate occurs when the diameter reaches 40 to 50 mm. AAA expansion is related to remodeling of the parietal extracellular matrix. The parietal mechanisms involved in this critical phase of sudden increase remain unexplained. Analysis of AAA wall movements and determination of AAA compliance may provide information about the constitution of the arterial wall. If a change in parietal wall motion somewhere between 40 and 50 mm could be shown, this would contribute to the understanding of the growth of AAA. Furthermore, it would provide a valuable additional parameter for AAA monitoring. This study had two aims: first, to evaluate the relationship between AAA compliance and maximum diameter using the tissue Doppler imaging system; and second, to test the hypothesis of a change in AAA behavior at around 45 mm in diameter. METHODS: Fifty-six patients with AAA (mean diameter, 39 mm) were prospectively investigated using the tissue Doppler imaging system, which provides information concerning arterial wall motion. Maximum mean segmental dilation (MMSD), segmental compliance, pressure strain elastic modulus (Ep), and stiffness were determined and related to the maximum diameter of AAA. Results After natural log transformation of all variables, there was a significant positive linear relationship between maximum diameter and both MMSD (P < .001) and segmental compliance (P < .001) but not with Ep or stiffness (P = .37 and .22, respectively). MMSD and segmental compliance were significantly higher in AAA > or = 45 mm than in AAA < 45 mm (P < .0002 and <. 004, respectively). Ep and stiffness tended to decrease in larger AAAs, but this was not statistically significant (P < .43 and .24, respectively). Dispersion of Ep and stiffness values seemed to be wider among AAA < 45 mm compared with those > or = 45 mm. CONCLUSION: Compliance parameters can easily be measured during routine AAA ultrasound monitoring using the tissue Doppler imaging system. The study showed an increase in MMSD and segmental compliance as well as a nonsignificant trend toward increased distensibility (decreased Ep and stiffness) with increased AAA diameter. A change in dispersion of AAA distensibility may appear around 45 mm in diameter, but a larger study will be needed to clarify this.

Abdominal Wall↗

Biophysical correlates of lysophosphatidylcholine- and ethanol-mediated shape transformation and hemolysis of human erythrocytes. Membrane viscoelasticity and NMR measurement.

The effects of monopalmitoylphosphatidylcholine (MPPC or lysophosphatidylcholine) and a series of short-chain primary alcohols (ethanol, 1-butanol and 1-hexanol) on cell shape, hemolysis, viscoelastic properties and membrane lipid packing of human red blood cells (RBCs) were studied. For MPPC, the effective membrane concentration to induce the formation of stage 3 echinocytes (8 x 10(6) molecules per cell) was one order of magnitude lower than that needed to induce 50% hemolysis (7 x 10(7) molecules per cell). In contrast, short-chain alcohols induced both shape changes and hemolysis within close concentration range (2.5 x 10(8) to 3.5 x 10(8) molecules per cell). Viscoelastic properties of the RBCs were studied by micropipette aspiration and correlated with shape change. Ethanol-treated RBCs showed a decrease in membrane elastic modulus and an increase in membrane viscosity in the recovery phase at the early stage of shape change. MPPC-treated cells showed the same type of viscoelastic changes, but these were not observed until the formation of stage 2 echinocytes. High-resolution solid-state 13C nuclear magnetic resonance technique was applied to study membrane lipid packing in the ghost membrane by following the chemical shift of hydrocarbon chains. Both MPPC and ethanol caused the 13C-NMR chemical shift to move upfield, indicating that membrane lipids were expanded due to the intercalation of these exogenous molecules. Using data obtained from model compounds, we convert values of chemical shift into a lipid packing parameter, i.e., number of gauche bonds for fatty acyl hydrocarbon chains. Approximately 10(8) interacting molecules per cell are required to induce a detectable change of lipid packing by both MPPC and ethanol. The results indicate that homolysis occurs at a smaller surface area for MPPC- than ethanol-treated RBCs. Our findings suggest that progressive changes in the molecular packing in the membrane lead eventually to hemolysis, but the mode responsible for shape transformation varies with these amphipaths.

Adult↗

Postnatal changes in the rheological properties of the aorta in Sprague-Dawley rats.

Postnatal changes in the rheological properties of the aortic wall were investigated in relation to morphological development of the wall in Sprague-Dawley (SD) rats at 3, 8 and 20 weeks old. The mechanical tensile characteristics of the longitudinal wall strip excised from the proximal thoracic aorta were assessed with stress-strain and stress-relaxation tests. Wall tension in the low and medium strain ranges was significantly lower in 3-week-old rats than in 8-week-old rats and in 8-week-old rats than in 20-week-old rats. Wall stress was significantly lower in 3-week-old rats than in 8- and 20-week-old rats mainly in the medium strain range, but was significantly greater in 3-week-old rats than in 8- and 20-week-old rats in the high strain range. The value of incremental elastic modulus at 3 weeks old was significantly smaller than that at 8 and 20 weeks old at a strain of 0.25 and significantly larger than that at 8 and 20 weeks old at a strain of 0.50. The value of relaxation strength at 5 min after the stretching was significantly greater at 3 weeks old than that at 8 and 20 weeks old. The wall was viscoelastic in the low and medium strain ranges at 3 weeks though large wall stress was generated in the high strain range. Histological investigation revealed that the smooth muscle layer, fine elastin fiber connecting thick elastin fibers and wall thickness were thin at 3 weeks old in comparison with those at 8 and 20 weeks old, though there was no significant difference in number of nuclei of the smooth muscle cells among the three age groups. Changes in the tensile characteristics of the wall reflected well those of the microstructure of the wall with growth. The rheological properties and microstructure of the aortic wall were close to maturation at 8 weeks in SD rats.

Aging↗

Real-time elastography--an advanced method of ultrasound: First results in 108 patients with breast lesions.

OBJECTIVES: To evaluate whether real-time elastography, a new, non-invasive method for the diagnosis of breast cancer, improves the differentiation and characterization of benign and malignant breast lesions. METHODS: Real-time elastography was carried out in 108 potential breast tumor patients with cytologically or histologically confirmed focal breast lesions (59 benign, 49 malignant; median age, 53.9 years; range, 16-84 years). Tumor and healthy tissue were differentiated by measurement of elasticity based on the correlation between tissue properties and elasticity modulus. Evaluation was performed using the three-dimensional (3D) finite element method, in which the information is color-coded and superimposed on the B-mode ultrasound image. A second observer evaluated the elastography images, in order to improve the objectivity of the method. The results of B-mode scan and elastography were compared with those of histology and previous sonographic findings. Sensitivities and specificities were calculated, taking histology as the gold standard. RESULTS: B-mode ultrasound had a sensitivity of 91.8% and a specificity of 78%, compared with sensitivities of 77.6% and 79.6% and specificities of 91.5% and 84.7%, respectively, for the two observers evaluating elastography. Agreement between B-mode ultrasound and elastography was good, yielding a weighted kappa of 0.67. CONCLUSIONS: Our initial clinical results suggest that real-time elastography improves the specificity of breast lesion diagnosis and is a promising new approach for the diagnosis of breast cancer. Elastography provides additional information for differentiating malignant BI-RADS (breast imaging reporting and data system) category IV lesions.

Adolescent↗

Force response to width and length perturbations in compressed skinned skeletal muscle fibers.

Previous studies have shown that radial compression of calcium-activated skinned skeletal muscle fibers, with attendant reduction of filament lattice spacing, reduces isometric force generation. In relaxed skinned fibers, radial compression produces a marked increase in axial elastic modulus, and the response to a small amplitude length perturbation resembles that of a muscle in rigor. We interpret these results as indicating that radial compression of the myofilament lattice produces "hindered" cross-bridges which are load bearing but not force generating. The experiments reported here were designed to study the effect(s) of "hindered" cross-bridges on both the time course of isometric force responses following Ca2+ activation and fiber width and length perturbations. The experiments were carried out at room temperature on radially compressed skinned single rabbit soleus fibers. Force development following step-wise Ca2+ activation and step-wise changes of fiber width was "slow" (60-90 sec) compared to that in normal width fibers (approximately 1 sec), and could be approximated by a single exponential curve. Force redevelopment following a length release in compressed fibers was both more rapid and more complicated than force development following activation and width steps, and required a double exponential curve for an adequate description. The results are consistent with the notion that hindered cross-bridges form as a result of lattice compression, and that the hindered bridges affect the force responses following width and length perturbations.

Adenosine Diphosphate↗

The effects of spinal fixation and destabilization on the biomechanical and histologic properties of spinal ligaments. An in vivo study.

STUDY DESIGN: An animal study was conducted to assess whether different surgical procedures of spinal fixation and destabilization would influence the biomechanics and histology of lumbar spinal ligaments. OBJECTIVES: To investigate the effects of spinal fixation and destabilization as well as surgical intervention itself on the biomechanical and histologic properties of lumbar spinal ligaments. SUMMARY OF BACKGROUND DATA: Although several investigators have reported normal biomechanical properties of different spinal ligaments, there have been no studies in which changes in spinal ligament properties, secondary to the altered biomechanical environment provided by such surgical procedures as spinal fixation and destabilization, have been investigated. METHODS: Thirty-six mature sheep were divided into four groups: Group I: nonsurgical control: Group II: sham operation consisting of bilateral posterolateral exposure at L4-L5; Group III: spinal fixation using transpedicular screws and plates and bilateral posterolateral bone graft at L4-L5; and Group IV: spinal destabilization consisting of bilateral facetectomy and anterior discectomy at L4-L5. Four months after surgery, the biomechanical analysis included destructive tensile testing of four different bone-ligament-bone complexes at the operative and proximal adjacent levels: anterior longitudinal ligament, posterior longitudinal ligament, ligamentum flavum, and supraspinous and interspinous ligaments combined. Histomorphometric analyses of the vertebral body and spinal ligaments were performed histomorphometrically. RESULTS: Biomechanical analysis results demonstrated remarkable changes in the structural and mechanical ligament properties at the operative level. The fixation group's ligaments showed consistent decreases in the ultimate load and elastic modulus compared with those parameters in the control group (P < 0.05). Histologically, the fixation group's ligamentum flavum showed marked vacuolation in the ligament substance, whereas the interspinous ligament exhibited significant insertion changes compared with little change in substance. In all eight sheep in Group IV, unintentional bilateral facet fusions were obtained; and in all eight animals in Group III with pedicle instrumentation and posterolateral fusion, solid arthrodesis was exhibited. This allowed a distinction to be made between the stress-shielding effect of spinal instrumentation and arthrodesis (Group III) versus spinal fusion alone (Group IV) on both spinal ligament and vertebral body. Group II (sham) had a significant decrease in supraspinous and interspinous ligaments, but nonsignificant decreases in the stress-shielding effect of 10-12% in other ligaments. CONCLUSIONS: Posterior spinal instrumentation and fusion led to decreased biomechanical properties of the ligamentum flavum, posterior longitudinal ligament, and interspinous and supraspinous ligaments. The stress-shielding effects were ligament dependent and were most pronounced on the posterior side. The altered biomechanical environment produced by spinal fixation, surgical intervention itself, or nonphysiologic mobilization can affect the ligamentous properties in vivo, possibly serving as the impetus for low back pain.

Animals↗

Biomechanical characterization and in vitro mechanical injury of elderly human femoral head cartilage: comparison to adult bovine humeral head cartilage.

OBJECTIVES: In vitro mechanical injury of articular cartilage is useful to identify events associated with development of post-traumatic osteoarthritis (OA). To date, many in vitro injury models have used animal cartilage despite the greater clinical relevance of human cartilage. We aimed to characterize a new in vitro injury model using elderly human femoral head cartilage and compare its behavior to that of an existing model with adult bovine humeral head cartilage. DESIGN: Mechanical properties of human and bovine cartilage disks were characterized by elastic modulus and hydraulic permeability in radially confined axial compression, and by Young's modulus, Poisson's ratio, and direction-dependent radial strain in unconfined compression. Biochemical composition was assessed in terms of tissue water, solid, and glycosaminoglycan (GAG) contents. Responses to mechanical injury were assessed by observation of macroscopic superficial tissue cracks and histological measurements of cell viability following single injurious ramp loads at 7 or 70%/s strain rate to 3 or 14 MPa peak stress. RESULTS: Confined compression moduli and Young's moduli were greater in elderly human femoral cartilage vs adult bovine humeral cartilage whereas hydraulic permeability was less. Radial deformations of axially compressed explant disks were more anisotropic (direction-dependent) for the human cartilage. In both cartilage sources, tissue cracking and associated cell death during injurious loading was common for 14 MPa peak stress at both strain rates. CONCLUSION: Despite differences in mechanical properties, acute damage induced by injurious loading was similar in both elderly human femoral cartilage and adult bovine humeral cartilage, supporting the clinical relevance of animal-based cartilage injury models. However, inherent structural differences such as cell density may influence subsequent cell-mediated responses to injurious loading and affect the development of OA.

Aged↗

Stiffness of the abdominal aorta in beta-thalassemia major patients related with body iron load.

OBJECTIVES: Increased iron stores have been implicated in the association with increased risk of cardiovascular events. We evaluated whether the abdominal aortic stiffness was altered in the patients with beta-thalassemia major in relation with body iron load. METHODS: Sixty-two (32 males and 30 females) beta-thalassemia major patients aged 16.47 +/- 4.8 years were enrolled into the study. Healthy 52 subjects matched for age and sex were recruited as controls. In all subjects, hemoglobin, fasting glucose, cholesterol, high-density lipoprotein-cholesterol, and low-density lipoprotein-cholesterol levels were measured. The average serum ferritin level and liver iron concentration (LIC) were assessed in thalassemia patients. Left ventricular function and mass were evaluated echocardiographically and aortic strain (S), pressure strain elastic modulus (Ep), and normalized Ep (Ep*), aortic distensibility (DIS), and beta stiffness index (beta index) were calculated in all subjects. RESULTS: There was no statistically significant difference between the study and control groups in sex, mean age, body mass index, heart rate, and systolic blood pressure (P > 0.05). However, pulse pressure and left ventricular mass index (LVMI) were found higher in thalassemia major patients compared with the control group. In beta-thalassemia major patients S (0.21 +/- 0.027 vs. 0.26 +/- 0.017, P < 0.0001) and DIS (1.07 +/- 0.25 vs. 1.56 +/- 0.37, P < 0.0001) were significantly lower compared with the control group. However, Ep (196.9 +/- 44.86 vs. 134.20 +/- 29.10, P < 0.0001), Ep* (3.26 +/- 0.98 vs. 2.04 +/- 0.60, P < 0.0001), and beta index (2.44 +/- 0.58 vs. 1.61 +/- 0.37, P < 0.0001) were significantly higher in beta-thalassemia patients than controls. There was a statistically significant negative correlation between LIC and S, DIS. There was also negative correlation between LVMI and S. However, there was a statistically significant positive correlation between LIC and Ep, Ep*. CONCLUSIONS: Increased abdominal aortic stiffness was detected in beta-thalassemia major patients and this increase in arterial stiffness correlated with LIC and LVMI.

Adolescent↗

A new bioactive bone cement: effect of glass bead filler content on mechanical and biological properties.

A new bioactive bone cement (designated GBC), consisting of bioactive glass beads as an inorganic filler and polymethylmethacrylate (PMMA) as an organic matrix, has been developed. The purpose of the present study was to examine the effect of the amount of glass bead filler added to GBC on its mechanical and biological properties, and to decide the most suitable content of filler. Serial changes in GBC with time were also examined. The newly designed bioactive beads, consisting of MgO-CaO-SiO2-P2O5-CaF2 glass, were added to the cement in the proportions 30, 40, 50, 60, and 70 wt %. These cements were designated GBC30, GBC40, GBC50, GBC60, and GBC70, respectively. The compressive strength and the elastic modulus of bending of GBC increased as the glass bead content increased. The various types of GBC were packed into the intramedullar canals of rat tibiae to evaluate osteoconductivity, as determined by an affinity index calculated as the length of bone in direct contact with the cement expressed as a percentage of the total length of the cement surface. Rats were killed at 4 and 8 weeks after the operation and the affinity index was calculated for each type of GBC. Histologically, new bone had formed along the surface of all types of GBC within 4 weeks, even in GBC30 containing only 30 wt % of glass beads. At each time interval studied, there was a trend for the affinity index of GBC to increase as the glass bead filler content increased. There was no significant increase of affinity index between GBC60 and GBC70. The affinity indices for all types of GBC increased significantly with time up to 8 weeks. The handling properties of GBC were comparable to those of conventional PMMA bone cement. We conclude that when mechanical properties and osteoconductivity are both taken into consideration, GBC60 is the most suitable formulation; it shows excellent osteoconductivity and sufficient mechanical strength for clinical use.

Animals↗

Model systems for the evaluation of mucolytic drugs: acetylcysteine and S-carboxymethylcysteine.

The therapeutic place of mucolytic drugs remains uncertain; clinical studies have seldom demonstrated significant benefit and the activity of such agents is poorly understood. In this study the effects of the mucolytic agents acetylcysteine (AC) and S-carboxymethylcysteine (SCMC) have been assessed in-vitro, using purified mucus gels and tracheal explant systems and in-vivo, in the mini-pig tracheal pouch model, in order to elucidate their mechanisms of action. A reduction in the elastic modulus (up to 70% over the frequency range 0.2-20 Hz) was apparent after treatment of mucus gels in-vitro with AC (P less than 0.05), but not with SCMC. Gel chromatography indicated that AC reduced the mucus glycoprotein to smaller subunits and a breakdown of gel structure was apparent when visualized using a cryofracture technique. SCMC treated gels were comparable with control samples. Mucus production was assessed in isolated rat trachea by monitoring the uptake and release of [3H] glucosamine. AC (5-15 mM) did not affect secretion whereas SCMC (5 and 10 mM) reduced the production of radiolabelled material (24 and 37%, respectively) over 24 h (P less than 0.05). Single oral doses of SCMC and AC (20 mg kg-1) were administered to mini-pigs and mucus collected from tracheal pouches; no significant changes in the rheological or biochemical properties of the secretion could be determined. The in-vitro mucolytic activity of AC depends upon a direct action on the secretion, SCMC appears able to reduce production of the mucus glycoprotein. Wide inter- and intra-individual variation in the properties of the secretion would suggest that such effects are not readily demonstrated in-vivo.

Acetylcysteine↗

An evaluation of the influence of orthodontic adhesive on the stresses generated in a bonded bracket finite element model.

The objective of this study was to evaluate the stresses generated in the bracket-cement-tooth continuum by a tensile load case when the physical and geometric properties of cement are varied. A 2-stage approach was used. In the first stage, a validated 3-dimensional finite element model of the bracket-cement-tooth system was constructed that consisted of 15,324 nodes and 2971 finite elements. Bracket base geometry was held constant; the physical properties (elastic modulus; Poisson's ratio) and geometry (lute thickness) of the cement varied. A simplified 2-dimensional model was then developed to investigate the localized effects of the cement lute thickness and the shape of the lute periphery on the stress distribution in the system. Small increases in stress were recorded under load within the cement as the rigidity of the cement increased. Similarly, Poisson's ratio values above 0.4 appeared to have a small influence on the major principal stresses in the impregnated wire mesh layer when a tensile force was applied. Variation in lute thickness was shown to have an influence on the distribution of major principal stresses within the cement lute. Increased stresses were recorded at the lute periphery as the lute dimensions increased. The morphologic features of the lute periphery also appeared to have had a significant effect on the performance of an orthodontic adhesive. Acute cement-enamel angles resulted in an increased chance of singularity development and attachment failure. The physical properties and thickness of the cement lute and the shape of the cement lute periphery contribute to the stress distribution within the bracket-cement-tooth continuum and, therefore, the quality of orthodontic attachment provided.

Adhesives↗

The fixation properties of carbon fiber-reinforced liquid crystalline polymer implant in bone: an experimental study in rabbits.

A novel composite material with ultra-high strength and a low elastic modulus called carbon fiber-reinforced liquid crystalline polymer (LCP/CF) has been developed. We studied the fixation properties of an intramedullary LCP/CF rod in rabbit bone. The medullary canals of both femora were reamed with a drill 3.2 mm in diameter starting from the trochanteric fossa in eleven New Zealand White rabbits weighing on average 4.8 kg. A smooth LCP/CF rod 3.2 mm in diameter and 50 mm in length was introduced into the medullary canal of both femora. The follow-up intervals were 0, 6, 12, and 52 weeks. The upper part of the harvested femora was cut into two pieces, each 25 mm in length. A mechanical push-out test was performed within 48 h to determine bone-implant interface attachment strength in the proximal (cancellous) and distal (cortical) locations. The mean push-out strength values at 0, 6, 12, and 52 weeks were 61, 250, 382, and 612 KPa in the cancellous location and 0, 32, 41, and 68 KPa in the cortical location, respectively. The strength of the bone/implant interface appeared to be quite low, similar to other uncoated or nonporous implants, but it was found to increase with time.

Animals↗

Effect of biphasic calcium phosphates on drug release and biological and mechanical properties of poly(epsilon-caprolactone) composite membranes.

Poly(epsilon-caprolactone) (PCL) and biphasic calcium phosphate (CaP) composite membranes were prepared for use in tissue regeneration by a novel solvent casting-pressing method. An antibiotic drug, tetracycline hydrochloride (TCH), was entrapped within the membranes to investigate the efficacy of the material as a drug delivery system. The CaP powders were varied in amount (0-50 wt %) and in powder characteristics by heat treating at different temperatures, and their effects on the mechanical and biological properties and drug release of the membranes were examined. With CaP addition up to 30 wt %, the elastic modulus of the membranes was enhanced much due to the rigidity of CaP. While the tensile strength and elongation rate decreased gradually with CaP addition because the CaP powders acted as a failure source. The osteoblast-like cells cultured on the CaP-PCL composite membranes exhibited significant improvements in proliferation and alkaline phosphatase (ALP) activity compared to pure PCL and culture plastic control, indicating excellent cell viability and functional activity. The TCH drugs were released from the PCL and CaP-PCL membranes in a similar fashion; an initial burst followed by a reduced release rate. The initial burst effect diminished much by the addition of CaP powders. The CaP addition increased the drug release rate after an initial period, and this was attributed to the high water uptake capacity and dissolution of the CaP containing membranes. Compared to the composite membranes containing heat-treated CaP powders, those with as-precipitated ones had higher dissolution and drug releases. These observations on mechanical properties and cellular responses as well as on drug release profiles suggested that the CaP-PCL composite membranes are potentially applicable to tissue regeneration and drug delivery system.

Animals↗

Basis of unique red cell membrane properties in hereditary ovalocytosis.

Hereditary ovalocytes from a Mauritian subject are extremely rigid, with a shear elastic modulus about three times that of normal cells, and have increased resistance to invasion by the malaria parasite Plasmodium falciparum in vitro. The genetic anomaly resides in band 3; the protein gives rise to chymotryptic fragments with reduced mobility in SDS/polyacrylamide gel electrophoresis, but this is a result of anomalous binding of SDS and not a higher molecular weight. Analysis of the band 3 gene reveals (1) a point mutation (Lys56----Glu), which also occurs in a common asymptomatic band 3 (Memphis) variant and governs the electrophoretic properties, and (2) a deletion of nine amino acid residues, including a proline residue, encompassing the interface between the membrane-associated and the N-terminal cytoplasmic domains. The interaction of the mutant band 3 with ankyrin appears unperturbed. The fraction of band 3 capable of undergoing translation diffusion in the membrane is greatly reduced in the ovalocytes. Cells containing the asymptomatic band 3 variant were normal with respect to all the properties that we have studied. Possible mechanisms by which a structural change in band 3 at the membrane interface could regulate rigidity are examined.

Adult↗

Relationship between abdominal aortic aneurysm wall compliance and clinical outcome: a preliminary analysis.

BACKGROUND: Aortic compliance, as measured by the pressure-strain elastic modulus (Ep) and stiffness (B), may allow a more precise estimate of abdominal aortic aneurysm rupture risk than size alone. AIM: To determine the relationships between AAA compliance, size, growth, and clinical outcome. METHODS: One-hundred and twelve patients with initially non-operated AAA (86 men, 26 women, mean age 73 years), recruited from five centres, underwent baseline compliance measurements and were then followed for a median of 7 (range 2-18) months; 85 patients underwent repeated measurements (median 3, range 2-5) 3-6-monthly over a median of 12 (range 3-18 months). RESULTS: Seven patients have ruptured and 16 have undergone repair of non-ruptured AAA. AAA that ruptured had significantly lower Ep and B (more compliant). In AAA that ruptured or required repair there was an inverse relationship between diameter and Ep and B. In those undergoing repeated measurements AAA expansion was only associated with a significant increase in Ep and B in non-operated patients. CONCLUSIONS: Baseline AAA compliance was significantly related to rupture and the future requirement for operative repair. Failure of compliance to increase with size may be a marker for rapid growth, developmental symptoms and rupture.

Aged↗

Bilayer membrane bending stiffness by tether formation from mixed PC-PS lipid vesicles.

Recently, a new approach to measure the bending stiffness (curvature elastic modulus) of lipid bilayer membrane was developed (Biophys. J., Vol. 55; pp. 509-517, 1989). The method involves the formation of cylindrical membrane strands (tethers) from bilayer vesicles. The bending stiffness (B) can be calculated from measurements of the tether radius (Rt) as a function of the axial force (f) on the tether: B = f.Rt/2 pi. In the present report, we apply this method to determine the bending stiffness of bilayer membranes composed of mixtures of SOPC (1-stearoyl-2-oleoyl phosphatidyl choline) and POPS (1-palmitoyl-2-oleoyl phosphatidyl serine). Three different mixtures were tested: pure SOPC, SOPC plus 2 percent (mol/mol) POPS, and SOPC plus 16 percent POPS. The bending stiffness determined for these three different lipid mixtures were not significantly different (1.6-1.8 x 10(-12) ergs). Because POPS carries a net negative charge, these results indicate that changes in the density of the membrane surface charge have no effect on the intrinsic rigidity of the membrane. The values we obtain are consistent with published values for the bending stiffness of other membranes determined by different methods. Measurements of the aspiration pressure, tether radius and the tether force were used to verify a theoretical relationship among these quantities at equilibrium. The ratio of the theoretical force to the measured force was 1.12 +/- 0.17.

Biomechanical Phenomena↗

Characterization and surface treatment effects on topography of a glass-infiltrated alumina/zirconia-reinforced ceramic.

OBJECTIVE: Characterize the microstructure, composition and some physical properties of a glass-infiltrated alumina/zirconia-reinforced ceramic (IZ) and the effect of surface treatment on topography. METHODS: IZ ceramic specimens were fabricated according to ISO6872 instructions and polished through 1 microm alumina abrasive. Quantitative and qualitative analyses were performed using scanning electron microscopy (SEM), backscattered imaging (BSI), electron dispersive spectroscopy (EDS) and stereology. The elastic modulus (E) and Poisson's ratio (nu) were determined using ultrasonic waves, and the density (rho) using a helium pycnometer. The following ceramic surface treatments were used: AP-as-polished; HF-etching with 9.5% hydrofluoric acid for 90 s; SB-sandblasting with 25 microm aluminum oxide particles for 15s and SC-blasting with 30 microm aluminum oxide particles modified by silica (silica coating) for 15s. An optical profilometer was used to examine the surface roughness (Ra) and SEM-EDS were used to measure the amount of silica after all treatments. RESULTS: The IZ mean property values were as follows: rho=4.45+/-0.01 g/cm(3); nu=0.26 and E=245 GPa. Mean Ra values were similar for AP- and HF-treated IZ but significantly increased after either SC or SB treatment (p<or=0.05). The surface concentration of Si(K) increased 76% after SC treatment. SIGNIFICANCE: HF is an inadequate surface treatment for bonding resins to IZ ceramic. Treating IZ with either SB or SC produced greater Ra values and the SC showed a significant increase in the surface concentration of silica, which may enhance bonding to resin via silane coupling.

Aluminum Oxide↗

Intrinsic stiffness of the carotid arterial wall material in essential hypertensives.

We have previously shown that the decrease in large artery distensibility observed in patients with essential hypertension (HT group) was primarily due to an increase in distending pressure and not to hypertension-associated structural modifications of the artery, suggesting a functional adaptation of the wall material. To evaluate the elastic properties of the wall material of the common carotid artery, we determined Young's incremental elastic modulus (Einc) in the HT group and in normotensive subjects (NT group) as a function of blood pressure and circumferential wall stress. In 102 HT patients with never-treated essential hypertension and 40 age- and gender-matched NT subjects, the Einc-pressure and Einc-stress curves were calculated from intima-media thickness and from diameter and pressure waveforms, determined with echo tracking and aplanation tonometry, respectively. The "effective" stiffness of the wall material, determined through Einc calculated at mean blood pressure, was significantly higher in the HT than in the NT group. The "intrinsic" stiffness of the wall material, determined through Einc calculated at a common circumferential wall stress, did not differ between the 2 groups. However, when each group (HT and NT) was analyzed according to tertiles of age, the "intrinsic" stiffness of the arterial wall material was increased only in younger HT patients. In middle-aged and older HT patients, the intrinsic mechanical properties of the carotid arterial wall material were unchanged, and the increased stiffness of the common carotid artery in the HT group was due primarily to the increased level of blood pressure. These results also indicate that the deleterious effects of aging and hypertension on "intrinsic" stiffness are not additive.

Adult↗