PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Quality Control”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98Linked to original sources

Reproducibility of detection of tyrosinase and MART-1 transcripts in the peripheral blood of melanoma patients: a quality control study using real-time quantitative RT-PCR.

In recent years, large discrepancies were described in the success rate of the tyrosinase reverse transcription polymerase chain reaction (RT-PCR) for detecting melanoma cells in the peripheral blood of melanoma patients. We present a quality control study in which we analysed the reproducibility of detection of tyrosinase and MART-1 transcripts in 106 blood samples from 68 melanoma patients (mainly stages III and IV). With this study, we aimed to improve insight in the reproducibility of a RT-PCR for the detection of (minimal) amounts of circulating melanoma cells. We performed two reverse transcriptions on each mRNA sample and performed tyrosinase and MART-1 nested PCRs in duplicate per cDNA sample. Thus, four tyrosinase and four MART-1 measurements were performed per blood sample. In our study, the majority of blood samples was negative for tyrosinase (80%) or MART-1 (66%). Only four samples were positive in all four determinations for tyrosinase and seven for MART-1. Variable results (1-3 times positive results) were obtained for tyrosinase and MART-1 in 16% and 27% respectively. MART-1 PCR had a better performance than tyrosinase PCR. Sensitivity increased when both markers were used. We reasoned that the low number of melanoma marker PCR-positive blood samples can be explained by differences in mRNA quality. By using real-time quantitative PCR, we found that this was not the case: amplification of porphobilinogen deaminase (PBGD), a low copy household gene, was not different in blood samples in which a melanoma marker was not detected from groups in which this marker was detected more or less consistently (1-4 times). When applying real-time quantitative PCR for tyrosinase and MART-1, we found that a low amount of SK-MEL-28 cell equivalents was present in the blood of melanoma patients, with a higher number of equivalents in the group with a consistently positive result. We conclude that low reproducibility of a repeated assay for the detection of circulating melanoma cells is not caused by differences in mRNA quality between the samples, but due to low numbers of amplifiable target mRNA molecules in the mRNA sample. Use of more than one marker and repetition of the assay will increase the probability of finding positive PCR results.

Adolescent↗

Quality control of custom block making in radiation therapy.

Custom blocks are the most commonly used field shaping device in radiotherapy. They offer many advantages in daily clinical use. However, as with all accessories used for patient treatments, care must be taken with their use. As such, a quality control program to check block cutting accuracy is recommended as a routine part of their clinical use. We have developed a three step method for checking custom blocks before they are used for patient treatment. These steps include: a static light check, a parallel opposed film check, and a block check involving the patient. By completing these three steps, we feel that we have improved the overall accuracy of our custom block making system which has resulted in more accurate treatments for our patients.

Humans↗

Large-scale screening for human parvovirus B19 DNA by PCR: application to the quality control of plasma for fractionation.

BACKGROUND AND OBJECTIVES: Because human parvovirus B19 (B19) has been transmitted by various plasma-derived medicinal products, the 'Laboratoire français du Fractionnement et des Biotechnologies' (LFB) implemented PCR screening of plasma pool samples for B19 DNA as part of the quality control of plasma source material. MATERIALS AND METHODS: Plasma pool samples (average of 46.5 donations) were tested for B19 DNA by PCR and by immunological detection of PCR products. The viral DNA content was determined by means of a TaqMantrade mark-based, quantitative PCR. RESULTS: From plasma corresponding to 2-year collections in France, and representing 4.26 million donations from approximately 1.25 million voluntary unpaid donors, the average frequency of positive donations was 1/5,950 and reached 1/1,420 during an epidemic. Levels of B19 DNA in positive pools ranged from <10(2) to 10(11) copies/ml. CONCLUSION: A large-scale PCR plasma screening increased the safety of LFB's wide range of products with respect to B19, a virus particularly resistant to physicochemical inactivation procedures.

Consumer Product Safety↗

Quality control of flow cytometric immunophenotyping of haematological malignancies.

Immunophenotyping of haematological malignancies has developed as a clinically valuable but technically complicated diagnostic procedure. It involves a variety of methodological features, in-process strategic judgements and an extensive knowledge of clinical, morphological and other laboratory features of the disease processes under study. We discuss the various internal quality control steps necessary to guarantee reliable results with respect to instrument set-up and calibration; sample preparation; selection and validation of monoclonal antibody panels; and flow cytometric data acquisition, analysis and interpretation of results. The quality of the entire procedure is documented by the analysis of representative specimens in the setting of an external quality assurance programme.

Flow Cytometry↗

Medicaid Program; Medicaid eligibility quality control, progressive reductions in federal financial participation for FYs 1982-84, payment for physician billing for clinical laboratory services, and utilization control of skilled nursing facility services: removal of obsolete requirements--HCFA. Final rule.

This final rule removes several obsolete sections of the Medicaid regulations that specify rules and procedures for disallowing Federal financial participation for erroneous medical assistance payments due to eligibility and beneficiary liability errors as detected through the Medicaid eligibility quality control program for assessment periods from 1980 through June 1990. The Medicaid regulations that contain the rules and procedures for the progressive reductions in Federal financial participation in medical assistance expenditures made to the States for fiscal years 1982 through 1984 are removed to reflect the repeal of the statutory bases for the reductions. The Medicaid regulations that provide for physician billing for clinical laboratory services that a physician bills or pays for but did not personally perform or supervise are removed to reflect the statutory repeal of this provision. In addition, the rule removes obsolete regulations that prescribe requirements concerning utilization control of Medicaid services furnished in skilled nursing facilities. This rule is part of the Department's initiate to reinvent health care regulations and eliminate obsolete requirements.

Centers for Medicare and Medicaid Services, U.S.↗

[Quality control of laser imagers].

Multiformat imagers based on laser systems are used for documentation in an increasing number of investigations. The specific problems of quality control are explained and the persistence of film processing in these imager systems of different configuration with (Machine 1: 3M-Laser-Imager-Plus M952 with connected 3M Film-Processor, 3M-Film IRB, X-Rax Chemical Mixer 3M-XPM, 3M-Developer and Fixer) or without (Machine 2: 3M-Laser-Imager-Plus M952 with separate DuPont-Cronex Film-processor, Kodak IR-Film, Kodak Automixer, Kodak-Developer and Fixer) connected film processing unit are investigated. In our checking based on DIN 6868 and ONORM S 5240 we found persistence of film processing in the equipment with directly adapted film processing unit according to DIN and ONORM. The checking of film persistence as demanded by DIN 6868 in these equipment could therefore be performed in longer periods. Systems with conventional darkroom processing comparatively show plain increased fluctuation, and hence the demanded daily control is essential to guarantee appropriate reaction and constant quality of documentation.

Diagnostic Imaging↗

[Within-day and between-day quality control of white blood cell differential by moving-average method].

Since its first appearance several years ago, automated blood cell analyzers capable of calculating white blood cell (WBC)-differential by flowmetric system have been widely accepted. Although these analyzers are fast and reliable, any other suitable quality control (QC) methods than Levey-Jennings (X) method have not been established yet. In this report, we provide evidence that Bull's moving-average (MA) method is extremely useful for within-day and between-day QC of WBC-differential assayed with flowmetric NE-7000 system. Monocyte(Mon) content in the control blood cells used in X method were varied among each lot, and the percentage of neutrophil(Neu) showed a tendency to decrease, while the percentage of Mon and basophil(Bas) showed a tendency to increase during storage. On the other hand, real-time QC of WBC-differential was enabled by the MA method that calculated mean value of each batch consisting of twenty samples. Within-day and between-day coefficient of variation (CV%) of WBC-differential controlled by the MA method was ranged from 5.0 for Neu to 12.5% for eosinophil(Eos) in patients' samples, and from 2.37% for Neu to 11.57% for Mon in healthy adults' samples. Therefore, we set up the limit of CV% for QC of WBC -differential by the MA method as follows: 10% for Neu, 20% for Lymphocyte, 30% for Mon, 20% for Eos and 20% for Bas. In addition, we report our experience of one occasion when sudden decrease of Mon to below the lower limit of the CV% was indicated by the MA method and suitable adjustment was made at once. The change was not detected by X method. In conclusion, the MA method is applied to real-time, daily and weekly/monthly QC of WBC-differential.

Adult↗

[Studies on the quality control of shangke wangshui].

Shangke Wangshui is a new Chinese traditional patent medicine. Its main ingredients Coptis Chinsis Franch, Phellodendron amurense Rupr. and Gardenia jasminoides Ellis. were identified by TLC and PC. The content of active component berberine in Shangke Wangshui was determined by TLC-scanner. This mothod is simple, quick and highly reproducible and can be as a quality control standards for this preparation.

Berberine↗

Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: impact and automated quality control.

BACKGROUND: Small-field-of-view (FOV) dedicated cardiac single photon emission computed tomography (SPECT) systems will frequently exhibit severe transmission scan truncation that may degrade attenuation correction (AC). This study evaluated the impact of transmission scan truncation on AC and developed automated transmission scan truncation quality control (ATSTQC) for small-FOV systems. METHODS AND RESULTS: Small-FOV data were simulated from the data of 10 patients acquired by a full-FOV Philips Vertex system. AC images of the full- and small-FOV data were compared by mean and maximum absolute differences of myocardial counts, and differences in stress and rest severity scores were calculated by use of the Emory Cardiac Toolbox.small-FOV systems. ATSTQC was developed to identify critical truncation that significantly increased these indices and then tested with 18 independent patients. Left-side truncation resulted in significant distortion of the quantitative indices. ATSTQC, developed on the condition that left-side truncation is critical, showed high concordance with the qualitative assessment in identification of critical truncation. CONCLUSIONS: Identification of left-side truncation as critical truncation is necessary to judge whether accurate AC can be obtained. The developed ATSTQC can accurately detect critical truncation and will help clinicians decide whether to use AC in a particular study.

Artifacts↗

Quality control measures for the serological diagnosis of hantavirus infections.

BACKGROUND: With society's rapidly increasing mobility, patients infected with severe viral infections can become seriously ill at any place in Europe and elsewhere. Improving the diagnostics of these infections is the most important step in detecting the pathogens and dealing with them, and for this purpose, quality control measures are essential tools. OBJECTIVES: To assess the diagnostic reality for rare hantavirus infections in Europe by (1) running a pre-evaluation panel (four samples, sent out in 1999) to optimise sample preparation and shipping procedure and afterwards (2) starting an External Quality Assurance (EQA) program (20 samples, sent out in 2001). STUDY DESIGN: All samples sent out had to be tested for the presence of specific IgG and IgM antibodies against hantavirus. For the pre-evaluation panel, four samples were distributed (two samples IgG+/IgM-, one sample IgG-borderline/IgM-, one sample IgG-/IgM-), for the EQA 20 samples (six samples IgG+/IgM+, eight samples IgG+/IgM-, one sample IgG-borderline/IgM-, five samples IgG-/IgM-). Thirteen laboratories took part in the pre-evaluation panel, 18 laboratories participated in the first EQA run. RESULTS: For the pre-evaluation panel, the participants reported correct results for 64% of the IgG-positive samples (85% excluding borderline-positive sample), and 92% for the IgG-negative sample. IgM testing was correctly negative in all laboratories. For the EQA, the participants reported correct results for 76% of the IgG-positive samples, and 97% correct results for the IgG-negative samples. For the IgM-positive samples, 53% correct results were reported, and 98% correct results for the IgM-negative samples. CONCLUSIONS: The results presented here prove the importance of quality measures also for viruses only rarely suspected, like hantavirus, and they clearly demonstrate the need for improvement of the existing test systems.

Antibodies, Viral↗

A call for mtDNA data quality control in forensic science.

There is increasing evidence that many of the mitochondrial DNA (mtDNA) databases published in the fields of forensic science and molecular anthropology are flawed. An a posteriori phylogenetic analysis of the sequences could help to eliminate most of the errors and thus greatly improve data quality. However, previously published caveats and recommendations along these lines were not yet picked up by all researchers. Here we call for stringent quality control of mtDNA data by haplogroup-directed database comparisons. We take some problematic databases of East Asian mtDNAs, published in the Journal of Forensic Sciences and Forensic Science International, as examples to demonstrate the process of pinpointing obvious errors. Our results show that data sets are not only notoriously plagued by base shifts and artificial recombination but also by lab-specific phantom mutations, especially in the second hypervariable region (HVR-II).

DNA Fingerprinting↗

Design of quality-control specimens for use with a small multi-channel analyzer.

Specimens having linear relationships between concentration and instrument response for seven analytes were prepared for use with a small multi-channel analyzer. The specimens had inter-specimen and inter-constituent relationships that facilitated the performance evaluation of all channels simultaneously with each individual specimen. Techniques are described for use of the specimens in various aspects of quality control.

Autoanalysis↗

Laboratory quality control: use of Shewhart charts and ANOVA.

For years industry has used the Shewhart charting system for determining precision and accuracy of industrial products. This method has been adapted to the clinical laboratory, in this project setting, and coupled with analysis of variance (ANOVA). The yield is an in-house quality control (QC) system that graphically shows ongoing precision and accuracy, gives limits of control based on the capabilities of procedures used in three of St. Luke's laboratories, shows within-day and between-day variation, and can be used for evaluation of new methods. The system not only points out problem areas, but enables inexperienced personnel to see when problems exist.

Analysis of Variance↗

Dissecting glycoprotein quality control in the secretory pathway.

In the early secretory pathway, asparagine-linked glycosylation facilitates the conformational maturation of diverse polypeptides by promoting their physical engagement with the glycoprotein-folding machinery. Misfolded glycoproteins are selectively eliminated from the endoplasmic reticulum by a stringent process of conformation-based quality control. Recent studies indicate that a small ensemble of oligosaccharide-processing enzymes and lectins use the asparagine-linked appendage to orchestrate the selective disposal of numerous transport-defective glycoproteins from the early secretory pathway. The glycan-based disposal system functions as an evolutionarily conserved terminal checkpoint in eukaryote genome expression. That the mechanisms by which glycoprotein substrates are recruited for degradation diverge at the level of signal recognition reflects a previously unappreciated component of cellular differentiation in higher eukaryotes.

Animals↗

[Quality control of capillary blood measurements in clinical services: follow up by the biologist].

In Bichat-Claude Bernard Hospital, the study of capillary glucose analyzers in the aim of uniformizing the selection of glucose meters, has shown the relevance of a standardized handling in order to obtain clinically interpretable results. It has been necessary to implement a quality follow up by the biologist. In the first stage, the biochemistry laboratory, with the clinical service supervisor and the supplier, has assured the training of the medical staff habilitated to use the meters and to carry out a quality control. In the second stage, the biologist implemented a monthly control on a total blood control sample, the stability of which has been checked after the necessary addition of glucose. Dosing of that sample, which is used as an external control, is carried out in parallel by the QID Precision glucose analyzer (Abbott) and by the portable Hemocue B Glucose (Vermed), which is selected as a comparison standard. This allows a monthly control of the accuracy of the meter. The condition of the equipment, as well as the weekly control follow up, validated by the nurse, is registered on a sheet prepared by the biologist. In partnership with Vermed, we have developed a processing software of the data stored in the Hemocue, allowing the automatic issue of a report summarizing the equipment condition and the data of weekly and monthly controls follow up. This report, signed by the biologist, is sent to every Service Manager and Supervising Nurse. On the basis of our one year experience, this practice has generated an efficient collaboration between the clinical services and the biochemistry laboratory, allowing to keep the quality of the capillary glucose measurements performed in inpatients.

Blood Chemical Analysis↗

Whole-blood test for total cholesterol by a self-metering, self-timing disposable device with built-in quality control.

A whole-blood test for total cholesterol has been developed that is performed in a low-cost disposable flow device without user intervention (after sample addition). The device meters the sample, separates plasma from erythrocytes, and precisely times plasma flow into various reagent compartments, including a quality-assurance chamber. Test results are displayed as a well-defined and easily readable color bar. A quality-control window attests to the integrity of the test components. Here, we describe the assembly and individual functions of the device and report its performance characteristics. Precision and accuracy studies in four clinical studies at independent locations yielded total imprecision of <5% and an average bias of 1.35% vs the Abell-Kendall method.

Cholesterol↗

Workshops for teaching quality control to laboratory personnel: objectives and guidelines.

The educational aspects are crucial for a successful implementation of new control procedures in the clinical laboratory. The initial effort can take the form of workshops directed to laboratory directors and supervisors on one hand, and to laboratory analysts on the other. The present paper gives an outline of objectives and guidelines for teaching quality control to these two groups of laboratory personnel.

Allied Health Personnel↗

Pharmaceutical development, quality control, stability and compatibility of a parenteral lyophilized formulation of the investigational polymer-conjugated platinum antineoplastic agent AP5346.

AP5346 is a low molecular weight polymer-conjugated platinum antineoplastic agent. The lyophilized drug product has completed a phase I clinical trial. In order to guarantee a constant quality of AP5346 pharmaceutical products, quality control and analysis of the drug substance and final product were performed. The identity of AP5346 was confirmed using 1H NMR, 195Pt NMR and IR spectroscopy. Furthermore, the free platinum content, platinum release characteristics, molecular size and size distribution were established. With the selected analytical techniques, AP5346 could be distinguished very well from its polymeric analogues, such as AP5280 and AP5279. Stability experiments revealed that AP5346 final product is stable for 12 months at 5 degrees C, in the dark. For administration to patients, AP5346 final product is reconstituted with 5% w/v dextrose and diluted in infusion containers. To investigate the influence of container materials, the stability of AP5346 after reconstitution and dilution in infusion containers was determined. The infusion containers investigated were composed of glass, polyvinyl chloride (PVC, intraflex) and low density polyethylene (LD-PE, Ecoflac). AP5346 was shown to be stable after reconstitution and dilution with 5% w/v dextrose in these infusion containers for at least 96 h at 2-8 degrees C in the dark and at room temperature with ambient light conditions.

Antineoplastic Agents↗