PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Simulation Training”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98Linked to original sources

A behavioral comparison of the helping styles of nursing students, psychotherapists, crisis interveners, and untrained individuals.

Helping styles of nursing students were compared with those of subjects in a prior study (17 psychotherapists, 12 crisis interveners, and 15 untrained people). Subjects were 30 junior-year college students in the second part of a two-course sequence in interpersonal relations. The subjects were videotaped in a 3-minute interaction with a simulated client. An experienced psychotherapist who was trained in the use of the Helping Skills Verbal Response System instrument rated each student. The helping behaviors of nursing students were found to resemble those of trained mental health practitioners; their behavior was significantly different from those of untrained individuals, who were highly verbose, directive, and used minimal reflection of affect or content.

Adult↗

Does the accuracy of single reading with CAD (computer-aided detection) compare with that of double reading?: A review of the literature.

AIM: To examine current evidence to determine whether the accuracy of single reading with computed-aided detection (CAD) compares with that of double reading. METHODS: We performed a literature review to identify studies where both protocols had been investigated and compared. We identified eight studies that compared single reading with CAD against double reading, of which six reported on comparisons of both sensitivity and specificity. RESULTS: Of the six studies identified, three showed no differences in either sensitivity or specificity. One showed single reading with CAD had a higher sensitivity at the same specificity, another that single reading with CAD had a higher specificity at the same sensitivity. However, one study, in a real-life setting, showed that single reading with CAD had a higher sensitivity but a lower specificity. CONCLUSION: As the majority of the studies were not in a real-life setting, used test sets, lacked sufficient training in the use of CAD and simulated double reading (using a protocol of recall if one suggests), current evidence is therefore limited as to the accuracy, in terms of sensitivity and specificity, of single reading with CAD in comparison with the most common practice in the UK of double reading using a protocol of consensus or arbitration.

Breast Neoplasms↗

Advances in video and imaging in ureteroscopy.

Advances in image processing and display technologies, such as digital imaging, HDTV, and virtual reality, will ultimately allow integration of endoscopic imaging with diagnosis and therapy during ureteroscopic procedures. Further improvements in simulation technology and telemedicine should improve surgical training and greatly benefit patient care.

Equipment Design↗

Preliminary evaluation of a prototype tube-valve-mask ventilator for emergency artificial ventilation.

STUDY OBJECTIVE: The objective was to design a prototype tube-valve-mask ventilator that would permit relatively inexperienced operators to provide adequate emergency artificial ventilation, namely, adequate ventilatory volumes and a high oxygen and low carbon dioxide delivery. DESIGN: The tube-valve-mask ventilator is powered by the exhaled air of the operator and uses a tube to act as an oxygen reservoir (1,300 mL) that is filled between breaths. Mouth-to-mouth breathing was the standard against which the tube-valve-mask ventilator and the other accepted methods of mouth-to-mask and bag-valve-mask were assessed. SETTING: Comparison studies were conducted during simulated two-person CPR using a training mannikin equipped to measure ventilation volume and delivered oxygen and carbon dioxide concentrations. TYPE OF PARTICIPANTS: Seventeen volunteer first-year nursing students were used as operators. INTERVENTIONS: The order in which the pairs of operators performed each of the techniques was randomized. MEASUREMENTS AND MAIN RESULTS: The ventilation volume and the percentage of oxygen and carbon dioxide delivered by each technique were as follows (mean +/- SD): Mouth-to mouth (760 +/- 290 mL, 17 +/- 1% O2, 3.4 +/- 0.4% CO2), mouth-to-mask (910 +/- 350 mL, 41 +/- 8% O2, 2.5 +/- 0.4% CO2), bag-valve-(soft) mask (550 +/- 230 mL, 94 +/- 3% O2, 0.03 +/- 0.02% CO2), bag-valve-(rigid) mask (560 +/- 300 mL, 96 +/- 3% O2, 0.03 +/- 0.02% CO2), and tube-valve-mask (860 +/- 290 mL, 91 +/- 7% O2, 0.2 +/- 0.2% CO2). CONCLUSION: In the hands of relatively inexperienced operators, mouth-to-mouth, mouth-to-mask, and tube-valve-mask techniques provide adequate ventilation volumes to a mannikin. This was not the case with the bag-valve-mask systems (800 mL; P = .05 by t test). Of the systems that provide adequate ventilation volume, the tube-valve-mask appears, superior in that higher oxygen and lower carbon dioxide concentrations can also be obtained (P = .05 by paired t test).

Breath Tests↗

Fuzzylot: a novel self-organising fuzzy-neural rule-based pilot system for automated vehicles.

This paper presents part of our research work concerned with the realisation of an Intelligent Vehicle and the technologies required for its routing, navigation, and control. An automated driver prototype has been developed using a self-organising fuzzy rule-based system (POPFNN-CRI(S)) to model and subsequently emulate human driving expertise. The ability of fuzzy logic to represent vague information using linguistic variables makes it a powerful tool to develop rule-based control systems when an exact working model is not available, as is the case of any vehicle-driving task. Designing a fuzzy system, however, is a complex endeavour, due to the need to define the variables and their associated fuzzy sets, and determine a suitable rule base. Many efforts have thus been devoted to automating this process, yielding the development of learning and optimisation techniques. One of them is the family of POP-FNNs, or Pseudo-Outer Product Fuzzy Neural Networks (TVR, AARS(S), AARS(NS), CRI, Yager). These generic self-organising neural networks developed at the Intelligent Systems Laboratory (ISL/NTU) are based on formal fuzzy mathematical theory and are able to objectively extract a fuzzy rule base from training data. In this application, a driving simulator has been developed, that integrates a detailed model of the car dynamics, complete with engine characteristics and environmental parameters, and an OpenGL-based 3D-simulation interface coupled with driving wheel and accelerator/ brake pedals. The simulator has been used on various road scenarios to record from a human pilot driving data consisting of steering and speed control actions associated to road features. Specifically, the POPFNN-CRI(S) system is used to cluster the data and extract a fuzzy rule base modelling the human driving behaviour. Finally, the effectiveness of the generated rule base has been validated using the simulator in autopilot mode.

Automation↗

Estimation of coupling strength in regenerated lamprey spinal cords based on a stochastic phase model.

We present a simple stochastic model of two coupled phase oscillators and a method of fitting the model to experimental spike-train data or to sequences of burst times. We apply the method to data from lesioned isolated lamprey spinal cords. The remaining tracts at the lesion site are either regenerated medial tracts, regenerated lateral tracts, control medial tracts, or control lateral tracts. We show that regenerated tracts on average provide significantly weaker coupling than control tracts. We compare our model-dependent estimate of coupling strength to a measure of coordination based on the size of deflections in the spike-train cross-correlation histogram (CCH). Using simulated data, we show that our estimates are able to detect changes in coupling strength that do not change the size of deflections in the CCH. Our estimates are also more resistant to changes in the level of dynamic noise and to changes in relative oscillator frequency than is the CCH. In simulations with high levels of dynamic noise and in one experimental preparation, we are able detect significant coupling strength although there are no significant deflections in the CCH.

Action Potentials↗

Oxygen consumption and speed of cycling using an air-resistance simulator on a hometrainer roller.

Oxygen consumption was determined for subjects cycling on a hometrainer roller with a racing bicycle. In part of the experiments the bicycle was supplied with an air-resistance simulator. The relation between oxygen consumption and velocity of cycling on the roller is linear: similar to that during bicycle ergometry. The relation is almost the same as during bicycling outdoors on a touring bicycle when the simulator is used while cycling on the roller. Cycling with the simulator only on the bicycle on a support is comparable to cycling outdoors on a racing bicycle. It is concluded that the use of a roller and an air-resistance simulator can be used for ergometry and training.

Air Movements↗

Bedside cardiac examination: constancy in a sea of change.

The general trend in the recent literature has been to highlight the difficulties and shortcomings of the physical examination and to attribute these difficulties to deficiencies in training rather than to intrinsic weaknesses in auscultation itself. The call is for better training. Given the advice of the authors mentioned above, individual training may be warranted at the postgraduate level and in the large community of practicing internists and cardiologists. Although not proven, it is likely that individual training with computer technology, audiotape instruction, or simulator technology such as described in the following paragraphs would be effective at improving bedside clinical diagnosis and cost-effective patient care in the postgraduate, continuing medical education setting. The advances in auscultation during the last few years have been more incremental than fundamental. There is ongoing research into the mechanism of production of S3 and S4, and mathematical modeling techniques have recently been used with some success in evaluating the vibrations of S3 and S4 as forced, damped oscillations of a viscoelastic system. Analysis of sound energy with the technique of spectral waveform analysis, which investigates the frequency content of sound signals, has been used for many years in the study of cardiovascular sound. By the use of various methods of mathematical analysis, investigators have found potentially useful information in spectral sound patterns of prosthetic valves, murmur characteristics, and even potentially hemodynamic information from heart sounds. Despite the mathematical advances, there are still disturbing drawbacks to some of the analytic techniques, such as the production of mathematical terms containing "negative energy." Although the potential of obtaining significant clinical information from spectral analysis of heart sound recordings is attractive, the clinical usefulness of such techniques remains virtually nonexistent. Similar to the recent advances in auscultation, the technical advances in the design of the stethoscope have also been more incremental than fundamental. There are at least 3 recently introduced electronic stethoscopes that have the capability of amplification and filtration and that claim noise reduction. Because their introduction is recent, no information is available in the peer-review literature regarding their clinical performance; therefore their place in the clinical arena remains to be elucidated--perhaps a boon for patient care providers with specific hearing defects and perhaps useful in noisy clinical environments. Peer-review literature has not shown clear superiority of one type of acoustic stethoscope over another. The teaching of auscultation has been an area of recognized importance in patient care since the inception of auscultation as a medical art. Attempts to facilitate practitioner learning in the performance and interpretation of auscultation have advanced through the decades limited only by the technical infrastructure of the day. The availability of recorded heart sounds and murmurs appeared shortly after the availability of recording and playback devices, with first vinyl and later tape recordings. In 1974, technology was employed to create a virtual patient named "Harvey," an engineered cardiology patient simulator that reproduces many of the physical findings of the cardiology examination. Later, with the advent of commercially available CD-ROM devices, newer, better-integrated teaching devices have been developed, some of them outstanding in their clarity and quality. Despite the obvious value of such instructional aids that are best used in the individual setting, there is evidence that the classroom is still of significant value in teaching auscultation. However, nowhere else in the practice of medicine is a mentor approach more valuable than in learning auscultation. (ABSTRACT TRUNCATED)

Cardiology↗

Rapid prototyping of temporal bone for surgical training and medical education.

OBJECTIVE: The skills of ear surgery are best developed by dissecting a temporal bone. However, only a limited number of trainees can be afforded this opportunity because of the scarcity of available bones. The aim of this study was to investigate the validity of a prototype temporal bone model for surgical training and education. MATERIAL AND METHODS: A simulated 3D model of a human temporal bone was made using a selective laser sintering method. The powder layers were laser-fused based on detailed CT data and accumulated to create a 3D structure. Conventional surgical instruments were used to dissect the model under a microscope. RESULTS: The model was as hard as real bone and surface structures were accurately reproduced. The model could be shaved using a surgical drill, burr and suction irrigator in the same way as a real bone. The malleus and incus were reproduced. The semicircular canals and the oval and round window niches were identified. Cavity structures, such as the semicircular canal, vestibule, antrum and air cells, were filled with powder which had to be removed using a pick and suction irrigator during dissection. A magnified model was useful for educating medical students. CONCLUSION: This prototype 3D model made using selective laser sintering serves as a good educational tool for middle ear surgery.

Humans↗

The characteristics of foot movements in Tai Chi Chuan.

This study examines how the characteristics of the foot movements in Tai Chi Chuan (TCC) contribute to a practitioner's health by improving his or her balance and reducing the risk of fall. Ten TCC masters are video-taped, and the time spent on different support patterns (step stance) and stepping directions (footwork) while performing the 42-form TCC is analyzed. In support patterns, it is found that a larger percentage of time is spent on the double leg stance (35.08 +/- 4.92) than on the single leg stance (Left: 17.67 +/- 7.71; Right: 17.29 +/- 2.23) and one leg support with another leg partially supporting type of stance (6.51 +/- 8.77). With regard to stepping directions, the centre footwork (25.25 +/- 10.20) requires a larger percentage of time than the forward (18.29 +/- 3.36), sideway (20.80 +/- 4.76), grinding (20.42 +/- 7.61), upward (11.55 +/- 1.49), and backward footwork (3.67 +/- 1.33). The movements classified are shown to simulate balance, flexibility and proprioception, and functional training. The findings partially explain the relationship between practising TCC and its health benefits. Further studies are suggested to investigate the health benefits that can be derived from other specific TCC movements.

Adult↗

Teaching digital rectal examinations to medical students: an evaluation study of teaching methods.

PURPOSE: The digital rectal examination (DRE) is a necessary part of a complete physical examination and evaluation of a patient, yet teaching of this examination to medical students is often inadequate. This study was a comparative evaluation of the effectiveness of the rectal teaching associate (RTA), lecture, role-playing, and simulated models as methods for teaching the DRE procedure to undergraduate medical students at Memorial University of Newfoundland Faculty of Medicine. METHOD: A total of 65 third-year medical students were randomly assigned to either an experimental or control group. Both groups received a lecture and practiced the DRE on a simulated model. The experimental group received further training from an RTA. Students completed a pre- and post-intervention knowledge assessment, an objective structured clinical exam (OSCE) measuring performance of the DRE, and a satisfaction survey. RESULTS: Mean knowledge scores increased significantly for both groups (18.73 to 22.32, p <.0001). The control group scored significantly higher on the post-intervention assessment than did the experimental group (23.11 versus 21.47, p =.025) The experimental group scored higher on the OSCE (27.52 versus 23.80, p =.001) and rated the RTA as a more effective method for learning the DRE. CONCLUSIONS: This first study using RTAs to teach the DRE as a global skill for evaluating the rectum suggests that the RTA method is effective for increasing skills and students' confidence in the procedure.

Curriculum↗

The genesis of neurosurgery and the evolution of the neurosurgical operative environment: part II--concepts for future development, 2003 and beyond.

The future development of the neurosurgical operative environment is driven principally by concurrent development in science and technology. In the new millennium, these developments are taking on a Jules Verne quality, with the ability to construct and manipulate the human organism and its surroundings at the level of atoms and molecules seemingly at hand. Thus, an examination of currents in technology advancement from the neurosurgical perspective can provide insight into the evolution of the neurosurgical operative environment. In the future, the optimal design solution for the operative environment requirements of specialized neurosurgery may take the form of composites of venues that are currently mutually distinct. Advances in microfabrication technology and laser optical manipulators are expanding the scope and role of robotics, with novel opportunities for bionic integration. Assimilation of biosensor technology into the operative environment promises to provide neurosurgeons of the future with a vastly expanded set of physiological data, which will require concurrent simplification and optimization of analysis and presentation schemes to facilitate practical usefulness. Nanotechnology derivatives are shattering the maximum limits of resolution and magnification allowed by conventional microscopes. Furthermore, quantum computing and molecular electronics promise to greatly enhance computational power, allowing the emerging reality of simulation and virtual neurosurgery for rehearsal and training purposes. Progressive minimalism is evident throughout, leading ultimately to a paradigm shift as the nanoscale is approached. At the interface between the old and new technological paradigms, issues related to integration may dictate the ultimate emergence of the products of the new paradigm. Once initiated, however, history suggests that the process of change will proceed rapidly and dramatically, with the ultimate neurosurgical operative environment of the future being far more complex in functional capacity but strikingly simple in apparent form.

Forecasting↗

Dynamical and stationary properties of on-line learning from finite training sets.

The dynamical and stationary properties of on-line learning from finite training sets are analyzed by using the cavity method. For large input dimensions, we derive equations for the macroscopic parameters, namely, the student-teacher correlation, the student-student autocorrelation and the learning force fluctuation. This enables us to provide analytical solutions to Adaline learning as a benchmark. Theoretical predictions of training errors in transient and stationary states are obtained by a Monte Carlo sampling procedure. Generalization and training errors are found to agree with simulations. The physical origin of the critical learning rate is presented. Comparison with batch learning is discussed throughout the paper.

Algorithms↗

An optimization methodology for neural network weights and architectures.

This paper introduces a methodology for neural network global optimization. The aim is the simultaneous optimization of multilayer perceptron (MLP) network weights and architectures, in order to generate topologies with few connections and high classification performance for any data sets. The approach combines the advantages of simulated annealing, tabu search and the backpropagation training algorithm in order to generate an automatic process for producing networks with high classification performance and low complexity. Experimental results obtained with four classification problems and one prediction problem has shown to be better than those obtained by the most commonly used optimization techniques.

Algorithms↗

Numerical analysis of dipole sound source around high speed trains.

As the maximum speed of high speed trains increases, the effect of aeroacoustic noise on the sound level on the ground becomes increasingly important. In this paper, the distribution of dipole sound sources at the bogie section of high speed trains is predicted numerically. The three-dimensional unsteady flow around a train is solved by the large eddy simulation technique. The time history of vortices shows that unstable shear layer separation at the leading edge of the bogie section sheds vortices periodically. These vortices travel downstream while growing to finally impinge upon the trailing edge of the section. The wavelength of sound produced by these vortices is large compared to the representative length of the bogie section, so that the source region can be regarded as acoustically compact. Thus a compact Green's function adapted to the shape can be used to determine the sound. By coupling the instantaneous flow properties with the compact Green's function, the distribution of dipole sources is obtained. The results reveal a strong dipole source at the trailing edge of the bogie section where the shape changes greatly and the variation of flow with time is also great. On the other hand, the bottom of the bogie section where the shape does not change, or the leading edge and boundary layer where the variation of flow with time is small, cannot generate a strong dipole source.

Journal Article↗

Periodic carbohydrate replacement during 50 min of high-intensity cycling improves subsequent sprint performance.

The purpose of this study was to investigate the effect of 7% carbohydrate-electrolyte (CE) drink on sprint capacity immediately following 50 min of high-intensity cycling. After an overnight 12-hr fast, 8 trained male cyclists performed two 50-min simulated time trials on a Monark stationary cycle ergometer. Subjects consumed either the CE or a flavored water placebo (PL) at 10, 20, 30, and 40 min during the time trial. At the conclusion of each 50-min time trial, subjects immediately performed a Wingate Anaerobic Power Test. Peak power, mean power, and minimum power were significantly higher for the CE trials, whereas mean RPE was significantly lower. Mean heart rate and fatigue index were not different between trials. These results suggest that sprint performance following a high-intensity simulated time trial of only 50 min can be improved with periodic consumption of CE during the ride, particularly following an overnight fast, when liver glycogen is likely to be low. These findings have implications for competitive cycling, where sprint capacity at the conclusion of a race is an important determinant of success.

Adult↗

Pulmonary barotrauma in submarine escape training.

A 25 year old submariner sustained pulmonary barotrauma during simulated submarine escape. The unusual features of the distribution of pleural and extrapleural air are described and explained.

Accidents, Occupational↗

Carry-over effects of marijuana intoxication on aircraft pilot performance: a preliminary report.

Ten experienced licensed private pilots were trained for 8 hours on a flight simulator landing task. They each smoked a cigarette containing 19 mg of delta 9-tetrahydrocannabinol (THC), and 24 hours later their mean performance on the flight task showed trends toward impairment on all variables, with significant impairment in number and size of aileron changes, size of elevator changes, distance off center on landing, and vertical and lateral deviation on approach to landing. Despite these deficits, the pilots reported no awareness of impaired performance. These results may have implications for performance of complex tasks the day after smoking marijuana.

Adult↗