PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “surface modification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98Linked to original sources

Comparison of poly(DL-lactide-co-glycolide) and polystyrene microsphere targeting to intestinal M cells.

The interaction of poly(DL-lactide-co-glycolide) (PLG) and polystyrene microspheres with the follicle-associated epithelium (FAE) of rabbit Peyer's patches was compared. Binding by PLG microspheres to the FAE was an order of magnitude lower than that of polystyrene microspheres of equivalent size (0.5-0.6 microns diameter). Although PLG microspheres are not selectively targeted to the M cell surface, as is the case with polystyrene microspheres, a high proportion of those that bind to M cells are transcytosed, resulting in the transepithelial delivery of 1.5 x 10(4) PLG microspheres/mm2 FAE. This represents the first direct demonstration of transepithelial delivery of PLG microspheres by M cells, which is crucial to the potential use of such vehicles for the oral delivery of drugs and vaccines. As native PLG microspheres are not optimally targeted to the M cell surface, there is scope for the further improvement of their efficacy by surface modifications.

Animals↗

Biocompatibility of heparin-coated circuits used in cardiopulmonary bypass.

The combined effect of heparin coating of cardiopulmonary bypass (CPB) circuits and reduced dose of systemic heparin on activation of the complement system and blood leukocytes was investigated in 19 patients undergoing coronary bypass surgery and randomly allocated to two groups. A heparin-coated CPB circuit together with a 50% reduction of the standard heparin dose were used for ten patients (HC group), and a standard CPB circuit with a standard heparin dose (300 IU/kg) for nine (C group). Significant rise in the levels of neutrophil-derived myeloperoxidase, lactoferrin and calprotectin were observed during CPB in both groups, but the total accumulated levels were significantly lower in the HC than in the C group (p < 0.05). Complement activation, assessed from levels of C3a and terminal complement complexes was similar in both groups. The lower levels of myeloperoxidase, lactoferrin and calprotectin during CPB in the HC group indicate that surface modification with end-point attached heparin enhances the biocompatibility of CPB.

Biocompatible Materials↗

Surface analysis of packaging materials. Part II.

The surfaces of medical device packaging can affect critical characteristics of the enclosed devices, such as biocompatibility and sterility. Techniques to evaluate surface modification and contamination in packaging applications are described in the second part of this two-part article.

Equipment Contamination↗

Polymer heart valves.

Since the introduction of valve replacement surgery, research has aimed at creating a prosthesis that is safe, durable and effective. Neither of the two broad groups of valve currently available is ideal. A prosthetic valve is needed that does not suffer from the known disadvantages of calcification and premature failure (bioprostheses), and thrombogenicity (mechanical valves). Much progress has been made, both in design and materials, and an extensive range of polymer valves has been produced and tested both in vitro and in vivo. Unfortunately, each stage of development has encountered problems preventing successful clinical application. Many design difficulties have been addressed and potentially reduced to acceptable levels, but calcification remains a problem, although much less so than with bioprostheses. New developments in surface modification may hold the key to the elimination of thrombus and calcification, and early in vivo results are promising. It is likely that an effective and safe polymer valve will soon become a third clinical option. The historic aspects behind the development of polymer valves and the current state of research and evaluation are discussed.

Animals↗

In vitro and in vivo assessment of bone-implant interface: a comparative study.

The present in vitro and in vivo comparison of three bioactive (HA, AP40, RKKP) and three bioinert (Ti6-Al4-V, Al2O3, ZrO2) materials was undertaken to identify which of them provide(s) the most suitable coating for prostheses implanted in patients with altered metabolic status. The experimental design included in vitro tests with human osteoblasts and morphological observations by scanning electron microscopy. For the in vivo evaluation, the materials were implanted in the femoral condyle of ovariectomised and intact female rats, and two months after surgery an X-ray microanalytical study was performed. The in vitro study showed good biocompatibility with all materials. Microanalysis evidenced a similar behaviour with all materials except the two biological glasses. The differences in Ca and P content observed between intact and ovariectomised rats can be explained by the intrinsic capability of biological glasses to undergo surface modifications in the presence of alterations of the bone metabolism. Thus, their use seems to be indicated in recipients with osteoporotic pathologies.

Animals↗

Characterization of very dense mineral oxide-gel composites for fluidized-bed adsorption of biomolecules.

Efficient design of fluidized-bed biomolecule adsorption from crude feed stock requires particles with elevated density, large adsorption capacity and broad chemical stability. Moreover, combinations of small particle diameters with high densities allow for high fluidization velocities while preserving a rapid mass transfer. This approach has been implemented by combining stable porous mineral oxide of high density (2.2, 4.7, 5.7, 9.4 g/ml) with functionalized hydrogels. The cross-linked hydrogel derivative fills the internal porosity of the beads and provides a high equilibrium binding capacity. Various porous mineral oxides (silica, titania, zirconia and hafnia) have been characterized in term of fluidization behavior, surface reactivity and chemical resistance to harsh CIP procedures. Porous zirconia particles were also modified into ion-exchangers by suitable surface modification and intraparticle polymerization of functionalized stable derivatives of acrylic monomers. Back-mixings in fluidized bed columns were analyzed by residence time distribution analysis of inert tracers. 328 and 218 mixing plates per meter were found for respectively, bed expansions of 1.7 and 2.9. The dynamic protein adsorption behaviors of zirconia-based polymeric anion-exchange sorbents were obtained in fluidized-bed, using BSA as model protein. A dynamic binding capacity of 62 mg/ml was observed at a fluidizing velocity of 320 cm/h. These investigations substantiate the favorable physical and chemical characteristics anticipated for dense composite beads for use as fluidized bed adsorbents.

Adsorption↗

Chrysotile-induced cell transformation and transcriptional changes of c-myc oncogene in human embryo lung cells.

It has been verified that asbestos induce neoplastic transformation of several rodent cell lines in vitro. Very little information is available, however, on asbestos-induced human cell line transformation and oncogene activation in the development of asbestos-induced cell transformation. This study was designed to investigate the induction of cell transformation and transcriptional changes of the c-myc oncogene by chrysotile asbestos fibers (CAF) in human embryo lung (HEL) cells. Surface-modified CAF soaked in aluminium citrate (AC), rare earth compounds (REC) or sodium selenite (SS) solutions were used to observe the effects of surface modification on chrysotile-induced cell transformation and transcriptional changes in the c-myc oncogene. The results showed that the natural CAF caused dose-dependent increases in transformed foci, along with increased transcription of the c-myc oncogene in HEL cells, while the pretreated CAF induced fewer transformed foci and less c-myc oncogene transcription than the natural CAF. The percent inhibition of equivalent AC, REC and SS were 38.9%, 50.0%, 33.3% (for transformation focus), 81.6%, 69.5%, 89.9% (for c-myc oncogene transcription), respectively. These results indicated that CAF may induce cell transformation and transcriptional changes and that the carcinogenicity of CAF might be reduced by pretreatment of CAF with the above-mentioned compounds.

Asbestos, Serpentine↗

[Corrosion and haemocompatibility of 316L stainless steel with electroplated Rh film].

In this study, surface modification by electroplating Rh on 316L stainless steel was carried out in order to improve the corrosion resistance and blood compatibility of implants. XPS was used to characterize the Rh film. The corrosion behavior of 316L stainless steel with electroplated Rh and non-treated was studied in Tyrode's biological solution. Additionally, the haemocompatibility of 316L stainless steel with electroplated Rh was evaluated by preliminary hemolysis test. The results showed that the corrosion resistance of 316L stainless steel with electroplated Rh was improved, and hemolysis decreased, which indicated that electroplating Rh can improve the blood compatibility of 316L stainless steel.

Animals↗

Delivery of human vascular endothelial growth factor with platinum coils enhances wall thickening and coil impregnation in a rat aneurysm model.

BACKGROUND AND PURPOSE: Histopathologic studies indicate that aneurysms treated with Guglielmi detachable coils (GDCs) have avascular centers with fibrosis mostly at the aneurysm periphery. We hypothesized that vascular endothelial growth factor (VEGF) released from a coil promotes clot organization, hyperplasia, and endothelial proliferation to facilitate closure of the aneurysm neck. METHODS: GDC segments were inserted into ligated common carotid arteries (CCAs) of adult male rats for 14 days. Coil segments (4-mm) were unmodified, modified with type I collagen (2.4 mg/mL), or modified with type I collagen and recombinant human VEGF-165 (rhVEGF; 500 microg/mL). CCA segments were harvested and coils removed for scanning electron microscopy (SEM). RESULTS: Collagen/rhVEGF coils (n = 11) resulted in marked reductions in CCA lumen area (0.03 mm(2)) compared with coils (n = 9, 0.21 mm(2), P <.001) and collagen coils (n = 5, 0.13 mm(2), P <.001). Collagen/rhVEGF coils (n = 11) also resulted in marked reductions in CCA diameter (0.19 mm) compared with coils (n = 9, 0.50 mm, P <.001) and collagen coils (n = 5, 0.40 mm, P <.001). Wall thickness was greater for the collagen/rhVEGF coil segments (0.22 mm) compared with coils (0.09 mm, P <.001), and the collagen coils (0.15 mm, P =.06). CCA segments containing collagen/rhVEGF coils also displayed Factor VIII positivity and were completely encapsulated in fibrotic tissue, while the unmodified and collagen coils were essentially smooth, as seen by SEM. CONCLUSION: These results suggest that rhVEGF may be beneficial in promoting endothelialization, clot organization, and tissue integration of the coils. This is the first study to hypothesize that rhVEGF may be useful as a surface modification to GDCs for enhancing their therapeutic effects in the treatment of cerebral aneurysms.

Animals↗

Dendrimer grafts for delivery of 5-fluorouracil.

Polyamidoamine (PAMAM) dendrimers were prepared by linking methyl methacrylate and ethylenediamine successively on an amine core. Surface modification of PAMAM dendrimer was done by fatty acid grafting converting them to a unimolecular micellar system (Dendrimer grafts). IR, 1H NMR, 13C NMR studies confirmed the structure. The drug 5-fluorouracil (5-FU) was entrapped in dendrimer grafts. The effects of various solvents (ethanol, dichloromethane, tetrahydrofuran), pH and ionic strength on solubilization of 5-FU were determined. Phospholipid was further coated on the dendrimer grafts. The product was lyophilized and obtained as yellowish-white powder. Average particle size was ca. 375 nm as determined by Malvern's Mastersizer 4. Drug loading was ca. 53% by weight. Stability studies were conducted for 1 month at room temperature and 40 degrees C, where the systems were relatively stable. Release rate was sustained across cellulose tubing in PBS. In vivo studies were performed in albino rats and pharmacokinetic parameters and bioavailability were determined from the plasma profile of 5-FU. The phospholipid coated dendrimer graft formulation was found to be more effective orally than free drug. The lymphatic uptake was also increased indicating absorption of the developed formulation through the lymphatic route.

Administration, Oral↗

Surface chemistry effects of topographic modification of titanium dental implant surfaces: 1. Surface analysis.

PURPOSE: To analyze the surface composition of 34 different commercially available titanium dental implants. MATERIALS AND METHODS: Surface composition was evaluated by x-ray photoelectron spectroscopy (XPS). Samples were divided into 4 groups, depending on their surface topography (machined, sandblasted, acid etched, or plasma sprayed). RESULTS: Statistical analysis of the data showed a clear relationship between surface composition and topography, which can be easily accounted for by the chemical effects of the surface treatment performed. On average, acid-etched and plasma-sprayed surfaces had higher titanium and lower carbon concentration than machined surfaces. DISCUSSION AND CONCLUSION: Current studies aimed at the evaluation of implants with different topography should not implicitly assume that topography is the only variable controlling the biologic response. Rather, when comparing different topographies, it should be taken into account that surface chemistry may be a variable as well.

Acid Etching, Dental↗

Surface chemistry effects of topographic modification of titanium dental implant surfaces: 2. In vitro experiments.

PURPOSE: To determine, in vitro, cytotoxicity and cell adhesion on 3 different implant surfaces. MATERIALS AND METHODS: All samples had machined surfaces, but they were subjected to different cleaning procedures, which produced 3 different surface chemistries. One of the samples was "as-produced" from the machining tools. The other samples were subjected to partial and total cleaning routines. Cytotoxicity was evaluated using mouse fibroblast cultures, and cell adhesion was evaluated with osteoblast-like SaOS-2 cells. RESULTS: The "as-produced" sample showed a pronounced surface contamination by lubricating oils. For partially and totally cleaned samples, an increasing amount of titanium and a decreasing carbon/titanium ratio was observed as cleaning became more complete. DISCUSSION: Differences in surface chemistry such as those normally found on titanium implant surfaces (see part 1 of this series) can lead to those same effects which, in in vitro experiments, are normally accounted for in terms of surface topography alone. CONCLUSION: Effects related to surface chemistry can operate over and above surface topography, making it impossible, without proper characterization, to make definite statements about the role of topography alone.

Animals↗

The importance of angiogenesis in the interaction between polymeric biomaterials and surrounding tissue.

The uncomplicated outcome of surgical interventions after biomedical application of biomaterials depends on successful wound healing. Wound healing is a highly complex process compossed of a number of overlapping phases, including inflammation, epithelialization, angiogenesis and matrix deposition. Inadequate angiogenesis limits the transport between the microvasculature and implanted biomaterials. The regulation of angiogenesis is based on numerous growth factors, proteolytic enzymes, extracellular matrix components, cell adhesion molecules, and vasoactive factors. Capillary endothelial cells were grown for different time periods (day 1, 3, 6, 9 and 12) on the surface of a recently developed biodegradable polymeric biomaterial. As control the cells were seeded on the gelatine coated polystyrene surface of commercially available cell cultures dishes. Endothelial cells became adherent and showed confluent cells layers during increasing time period on both surfaces. The total cell number of cells grown on the gelatine coated polystyrene surface was higher in comparison to the polymer surface. The chorioallantois membrane (CAM) assay was used as a sensitive assay to investigate the influence of angiogenesis in vivo. After 48 hours of exposure of the CAM to polymer samples no avascular zones, free of capillaries and/or thrombosis or hemorrhage were detectable. Considering the biofunctionality of our recently developed polymer in these experiments different surface modifications of the polymer are the topic of current investigation to support the biomaterial-microvasculature interactions in vivo.

Absorbable Implants↗

Block copolymers as drug carriers.

The main subject of this review is to describe the concept and strategy of utilizing block copolymers as drug carriers and to present a perspective for this utilization. The first section points out preferable properties of block copolymers as drug carriers with a brief survey on classifications and synthesis of block copolymers and specifies the merits of block copolymers for this purpose in the historical background of polymeric drug carriers. The second section introduces several studies using block copolymers as drug carriers. These studies contain surface modification of microspheres with block copolymers, polymeric micelles, and a conjugate of an antibody and block copolymer. In conclusion, it is determined that block copolymers possess a high potential for use as drug carriers irrespective of some difficulties in their synthesis.

Animals↗

[Heterotopic osteogenesis of autogenous marrow stromal cells with recombinant human bone morphogenetic protein 2 gene transfection and porous calcium phosphate ceramic as a scaffold].

OBJECTIVE: To observe the heterotopic osteogenesis of autogenous marrow stromal cells loading on porous calcium phosphate ceramic scaffolds with rhBMP2 gene transfection in a Sprague-Dawley rat model. METHODS: Autogenous marrow stromal cells were obtained from left femurs and tibias of 20 male adult SD rats under general anesthesia and sterile condition and cultured in alpha-Minimal Essential Medium supplemented with 15% fetal bovine serum. RhBMP2 gene was transfected into stromal cells by means of LipofectAMINE 2000 reagent five days after primary culture. The stably gene expressive cells were selected with G-418 for 14 days and mixed with stromal cells without transfection. The mixture cells were seeded and subcultured for another 10 days in porous calcium phosphate bioceramic that had been subjected to surface-modification via soaking in human plasma fibronectin. The cell-ceramic compound was implanted subcutaneously and intramuscularly in the corresponding rat. Lab animals were sacrificed at two-week intervals till twenty weeks postoperatively and the involved samples were removed. RESULTS: Morphologic and histological study demonstrated that cell-ceramic compound had an ability of heterotopic osteogenesis, which was similar to that of autogenous osteoblasts in previous study. CONCLUSION: It seems that autogenous stromal cells with rhBMP2 transfection acts as a bioreactor promoting proliferation and differentiation of stem cells when they are replanted into the corresponding animals.

Animals↗

Preventing medical device related infections.

Antimicrobial surfaces are a major advance in the ability to design biomaterials that resist colonization and subsequent infection. By reducing device-related infections, infection-resistant biomaterials will greatly improve the effectiveness of the device, which in turn will significantly decrease post-operative health risks and health-care costs. This overview of new surface modification technologies highlights strategies to prevent device-related infections.

Anti-Infective Agents↗

Role of precoating in artificial vessel endothelialization.

As the progress of vascular surgery, artificial vessels have become the substitute for large and middle diameter vessels but have not for small diameter ones owing to thrombogenesis and occlusion within a short period of time after being applied. Artificial vessel endothelialization is one of the ideal methods to resolve such issue and has been improved continuously since Herring in 1978 put forward this term in the first time and utilized vascular endothelial cells (ECs) harvested from living animals to perform the test of artificial vessel endothelialization. However, human endothelial cells show little adhesion to the currently available vascular graft materials and some expanded polytetrafluoroethylene (ePTFE) grafts have shown only 10%+/-7% endothelial cell attachment rate (ECA, ie, attachment of ECs when incubated in vitro). Moreover, when the graft is exposed to pulsatile blood flow, a high proportion of cells are washed off from the lumen. Maximum cell loss occurs in the first 30-45 min after exposure to pulsatile flow, with up to 70% of cells lost. After that, a slower exponential loss occurs over the next 24 h. The lack of retention of cells could be partly overcome by sodding, but other techniques, involving engineering the lumen to improve ECA and endothelial cell retention rate (ECR, ie, retention of ECs when the grafts are exposed to pulsatile flow) have been developed. These include shear stress preconditioning, electrostatic charging and, above all, most successfully to date, precoating with EC specific adhesive glues that are mostly found in the extracellular basement membrane of blood vessels. The commonest are chemical coatings, preclotting, chemical bonding, and surface modifications.

Blood Vessel Prosthesis↗

Typological and technological study of prehistoric implements in animal hard tissues.

Several series of prehistoric implements in animal hard tissues, either from ancient and recent excavations, were studied by the typological and technological points of views. Their morpho-typological description was in many cases associated to microscopic study of surface modifications, often allowing identification of traces related to manufacture. This technological information in some cases could be integrated by the observations of use-wear, thus providing functional indications. Implements came from sites of different antiquity and different geographic areas (from Liguria to Calabria). Implements considered by the research program included tools, pendants and other ornamental objects, as well as unfinished implements and manufacture left-overs often identified during revision of faunal remains. Middle Paleolithic bone fragments bearing traces of non-alimentary anthropic actions were limited to the so-called "retouchers". However, during Upper Paleolithic, implements in animal hard tissues were relatively frequent in most Italian sites, even if those industries were not so rich, elaborated and typologically differentiated as in other European areas.

Animals↗