PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ATMOSPHERIC PRESSURE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Atmospheric pressure chemical ionization and atmospheric pressure photoionization for simultaneous mass spectrometric analysis of microbial respiratory ubiquinones and menaquinones.

An atmospheric pressure photoionization (APPI) source and an atmospheric pressure chemical ionization (APCI) source were compared for the selective detection of microbial respiratory ubiquinone and menaquinone isoprenologues using tandem mass spectrometry. Ionization source- and compound mass-dependent parameters were optimized individually for both sources, using the available quinone standards. Detection levels for the two ion sources were determined with ubiquinone-6 (UQ6) and menaquinone-4 (MK4, vitamin K2) standards using flow injection analysis and selected reaction monitoring (SRM). With APPI the calculated lower limit of detection (LLOD) was 1.7 fmol microl(-1) for UQ6 and 2.2 fmol microl(-1) for MK4 at a signal-to-noise ratio of 3. These LLODs were at least three times lower than with APCI. The selectivity of detection afforded by SRM detection reduced complex mixture analysis to 3 min per sample by eliminating the need for chromatographic separations. The detection method was successfully applied to quinone quantification in a variety of environmental samples and cell cultures. Adequate amounts of respiratory quinones can be extracted and quantified from samples containing as low as 2 x 10(7) cells.

Atmospheric Pressure↗

Comparison of electrospray, atmospheric pressure chemical ionization, and atmospheric pressure photoionization in the identification of apomorphine, dobutamine, and entacapone phase II metabolites in biological samples.

The applicability of different ionization techniques, electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and a novel atmospheric pressure photoionization (APPI), were tested for the identification of the phase II metabolites of apomorphine, dobutamine, and entacapone in rat urine and in vitro incubation mixtures (rat hepatocytes and human liver microsomes). ESI proved to be the most suitable ionization method; it enabled detection of 22 conjugates, whereas APCI and APPI showed only 12 and 14 conjugates, respectively. Methyl conjugates were detected with all ionization methods. Glucuronide conjugates were ionized most efficiently with ESI. Only some of the glucuronides detected with ESI were detected with APCI and APPI. Sulfate conjugates were detected only with ESI. MS/MS experiments showed that the site of glucuronidation or sulfation could not be determined, since the primary cleavage was a loss of the conjugate group (glucuronic acid or SO3), and no site-characteristic product ions were formed. However, it may be possible to determine the site of methylation, since methylated products are more stable than glucuronides or sulfates. Furthermore, the loss of CH3 is not necessarily the primary cleavage, and site characteristic products may be formed. Identification and comparison of conjugates formed from the current model drugs were successfully analyzed in different biological specimens of common interest to biomedical research. A fairly good relation was obtained between the data from in vivo and in vitro models of drug metabolism.

Animals↗

Comparison of electrospray ionization, atmospheric pressure chemical ionization, and atmospheric pressure photoionization for the analysis of dinitropyrene and aminonitropyrene LC-MS/MS.

The only relevant source for human exposure to dinitropyrenes is diesel engine emissions. Due to this specificity, dinitropyrenes may be used as biomarkers for monitoring human exposure to diesel engine emissions. Only few analytical methods have been described for the quantitation of dinitropyrenes and their metabolites, aminonitropyrenes, and diaminopyrenes. Therefore, for dinitropyrenes, aminonitropyrenes, and diaminopyrenes were selected as model compounds for the development of a sensitive HPLC-MS/MS method (high performance liquid chromatography coupled to triple quadrupole mass spectrometry) was to quantify polyaromatic amines and nitroarenes in biological matrices was developed optimal methods by comparing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photoionization (APPI) sources. Dinitropyrene was not effectively ionized and diaminopyrene yielded mainly [M(.)](+) ions by electrospray ionization. With APCI and APPI, precursor ions of diaminopyrene and aminonitropyrene were [M + H](+) and [M(.)](-) for dinitropyrene. Precursor ions with [M - 30(.)](-) for dinitropyrene and [M - 30 + H](+) for aminonitropyrene were observed. Reversed and normal phase HPLC-MS/MS with ESI, APCI and APPI were optimized separately with respect to unequivocal analyte identification and sensitivity. Normal phase HPLC coupled to APPI-MS/MS gave the highest precision and sensitivity for aminonitropyrene (6%/0.2 pg on column) and dinitropyrene (9%/0.5 pg on column). The limit of detection in spiked rat plasma was 5 pg/100 microL for aminonitropyrene (accuracy 82%) and 10 pg/100 microL for dinitropyrene (accuracy 105%). In plasma of rats treated with dinitropyrene by oral administration, no detectable levels of dinitropyrene but higher aminonitropyrene levels compared with intratracheal instillation were observed. These findings clearly demonstrate that dinitropyrene was absorbed after oral and intratracheal application and that a reduction of nitro groups occurs to a high extent in the reductive environment of the intestine. To our knowledge, this is the first time that aminonitropyrene was observed in plasma after intratracheal or oral administration directly demonstrating the reductive metabolism of dinitropyrene in vivo.

Air Ionization↗

Liquid chromatography/mass spectrometry in anabolic steroid analysis--optimization and comparison of three ionization techniques: electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization.

The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.

Anabolic Agents↗

Surface-assisted reduction of aniline oligomers, N-phenyl-1,4-phenylenediimine and thionin in atmospheric pressure chemical ionization and atmospheric pressure photoionization.

Reduction of the oligomers formed from on-line electropolymerization of aniline, the compound N-phenyl-1,4-phenylenediimine, and the thiazine dye thionin was observed in both an atmospheric pressure chemical ionization and an atmospheric pressure photoionization source. The reduction, which alters the mass of these analytes by 2 Da, was shown to occur by means of a surface-assisted process which involves reactive species, possibly hydrogen radicals, generated from protic solvents in the ionization plasma. Reduction was minimized by limiting protic solvents, by using a high heated nebulizer temperature, and by using a clean, heated nebulizer probe liner. The expected generality of this reduction process, and the possibility of similar reduction processes in other plasma ionization sources are discussed in relation to the use of these ion sources for on-line electrochemistry/mass spectrometry experiments.

Journal Article↗

Effect of eluent on the ionization efficiency of flavonoids by ion spray, atmospheric pressure chemical ionization, and atmospheric pressure photoionization mass spectrometry.

The effect of nine different eluent compositions on the ionization efficiency of five flavonoids was studied using ion spray (IS), atmospheric pressure chemical ionization (APCI), and the novel atmospheric pressure photoionization (APPI), in positive and negative ion modes. The eluent composition had a great effect on the ionization efficiency, and the optimal ionization conditions were achieved in positive ion IS and APCI using 0.4% formic acid (pH 2.3) as a buffer, and in negative ion IS and APCI using ammonium acetate buffer adjusted to pH 4.0. For APPI work, the eluent of choice appeared to be a mixture of organic solvent and 5 mM aqueous ammonium acetate. The limits of detection (LODs) were determined in scan mode for the analytes by liquid chromatography/mass spectrometry using IS, APCI and APPI interfaces. The results show that negative ion IS with an eluent system consisting of acidic ammonium acetate buffer provides the best conditions for detection of flavonoids in mass spectrometry mode, their LODs being between 0.8 and 13 microM for an injection volume of 20 microl.

Journal Article↗

Determination of carbamate pesticide residues in vegetables and fruits by liquid chromatography-atmospheric pressure photoionization-mass spectrometry and atmospheric pressure chemical ionization-mass spectrometry.

A liquid chromatography-atmospheric pressure photoionization (APPI)-mass spectrometry method was developed for the determination of 22 carbamates including their metabolites in vegetables and fruits. For the optimization of APPI, several APPI ion source parameters were examined. As a result, many carbamates with APPI using the optimized parameter gave simple mass spectra, and a strong signal corresponding to [M + H](+) was observed except for aldicarb. However, some carbamate metabolites gave ammonium adduct ions [M + NH(4)](+) as base peak ions. The mean recovery of each carbamate from grape and onion samples spiked at 5 ng/g was 81.7-105.7%, with relative standard deviations of 3.3-5.9%. Furthermore, matrix constituents did not significantly influence the ionization efficiency. The limit of detection (S/N = 3) in grape and onion was in the range of 0.33-3.33 ng/g. For the robustness of this method, this system has been used to analyze 50 samples, and the intensities for all carbamates were found to be unaffected by the contamination of the APPI source by sample matrix constituents. This result indicates that the method is reliable.

Atmospheric Pressure↗

Capillary column supercritical fluid chromatography-atmospheric pressure ionisation mass spectrometry interface performance of atmospheric pressure chemical ionisation and electrospray ionisation.

A supercritical fluid chromatography interface probe for atmospheric pressure ionisation mass spectrometry (API-MS) with the advantage of convenient switch between ionisation modes [atmospheric pressure chemical ionisation (APCI) and electrospray ionisation (ESI)] has recently been reported [P.J.R. Sjöberg, K.E. Markides, J. Chromatogr. A, 785 (1997) 101]. In order to obtain a stable ion signal and a low minimum detectable quantity, the design of the spray devise has to be optimised. For easy optimisation in the APCI mode, the corona needle was mounted directly on the interface probe. To compensate for the adiabatic cooling of the expanding mobile phase in the APCI mode, a heated region around the restrictor tip was used. In comparison, ESI required no additional heat, which might also prevent fragmentation for thermolabile compounds. As the mobile phase used was neat CO2, a low flow of make-up liquid was utilised in the ESI mode for transfer of the analytes from the expanding CO2 gas to the liquid phase before ionisation. The low make-up liquid flow in the ESI mode was sufficient for preventing the restrictor from becoming blocked. Factors that influence the ion signal intensity and stability have been studied. In APCI mode, corona needle position, nebuliser gas flow and gas additives were studied and in ESI mode, spray capillary assembly dimension and position, liquid flow-rate and composition were studied. The achievable detection limits were in the 50-0.1 pg (i.e., 290 fmol-140 amol) range. The detection limit in APCI mode was improved by a factor of about 20-25 compared to an earlier design [L.N. Tyrefors, R.X. Moulder, K.E. Markides, Anal. Chem. 65 (1993) 2835].

Atmospheric Pressure↗

[Dynamics of atmospheric pressure under the maxillary complete denture. 1. Relations between the denture retention and the atmospheric pressure].

Dynamics of atmospheric pressure under the maxillary complete denture, and their relations with the denture retention influenced by the factors such as the denture seating force, the saliva viscosity and the postdamming, were investigated on the simulation models. The following results were obtained. 1. The atmospheric pressure under the denture became higher than the external one by the denture insertion, and increased during the denture seating, and decreased by the removing force of denture and furthermore became lower than external one by continuous application of its force, and at all became equal to the external one when the denture separated from the basal seat. 2. Greater seating force brought about greater positive pressure and less negative pressure. 3. Higher viscosity of saliva and the postdamming brought about greater positive and negative pressures. 4. Both of greater seating force and higher viscosity of saliva brought about greater retentive force. 5. The postdamming was useful for the maxillary posterior border seal. 6. The atmospheric pressure under the denture base seems not to relate directly to the maxillary denture retention in the static condition but to reveal the status of peripheral seal.

Atmospheric Pressure↗

Atmospheric pressure chemical ionization of fluorinated phenols in atmospheric pressure chemical ionization mass spectrometry, tandem mass spectrometry, and ion mobility spectrometry.

Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.

Atmospheric Pressure↗

An atmospheric pressure chemical ionization study of the positive and negative ion chemistry of the hydrofluorocarbons 1,1-difluoroethane (HFC-152a) and 1,1,1,2-tetrafluoroethane (HFC-134a) and of perfluoro-n-hexane (FC-72) in air plasma at atmospheric pressure.

A report is given on the ionization/dissociation behavior of the title compounds within air plasmas produced by electrical corona discharges at atmospheric pressure: both positive and negative ions were investigated at different temperatures using atmospheric pressure chemical ionization mass spectrometry (APCI-MS). CHF(2)CH(3) (HFC-152a) undergoes efficient ionic oxidation to C(2)H(5)O(+), in which the oxygen comes from water present in the plasma. In contrast, CF(3)CH(2)F (HFC-134a) does not produce any characteristic positive ion under APCI conditions, its presence within the plasma being revealed only as a neutral ligand in ion-molecule complexes with ions of the background (H(3)O(+) and NO(+)). Analogously, the perfluorocarbon FC-72 (n-C(6)F(14)) does not produce significant positive ions at 30 degrees C: at high temperature, however, it undergoes dissociative ionization to form many product ions including C(3)F(6)(+), C(2)F(4)(+), C(n)F(2n+1)(+) and a few families of oxygen containing cations (C(n)F(2n+1)OH(2)(+), C(n)F(2n)OH(+), C(n)F(2n-1)O(+), C(n)F(2n-1)O(2)H(2)(+), C(n)F(2n-2)O(2)H(+)) which are suggested to derive from C(n)F(2n+1)(+) in a cascade of steps initiated by condensation with water followed by steps of HF elimination and H(2)O addition. Negative ions formed from the fluoroethanes CHF(2)CH(3) and CF(3)CH(2)F (M) include complexes with ions of the background, O(2)(-)(M), O(3)(-)(M) and some higher complexes involving also water, and complexes of the fluoride ion, F(-)(H(2)O), F(-)(M) and higher complexes with both M and H(2)O also together. The interesting product O(2)(-)(HF) is also formed from 1,1-difluoroethane. In contrast to the HFCs, perfluoro-n-hexane gives stable molecular anions, M(-), which at low source temperature or in humidified air are also detected as hydrates, M(-)(H(2)O). In addition, in humidified air F(-)(H(2)O)(n) complexes are also formed. The reactions leading to all major positive and negative product ions are discussed also with reference to available thermochemical data and relevant literature reports. The effects on both positive and negative APCI spectra due to ion activation via increasing V(cone) are also reported and discussed: several interesting endothermic processes are observed under these conditions. The results provide important information on the role of ionic reactions in non-thermal plasma processes.

Air↗

Characterization of triglycerides in vegetable oils by silver-ion packed-column supercritical fluid chromatography coupled to mass spectroscopy with atmospheric pressure chemical ionization and coordination ion spray.

Characterization of triglycerides in vegetable oils was achieved by silver-ion packed-column supercritical fluid chromatography (SI-pSFC) with mass spectrometric detection. Hyphenation was made using commercially available liquid chromatography-mass spectrometry (LC-MS) interfaces without any modification. A make-up fluid was delivered through a T-piece placed before or after the SFC restrictor by means of a high pressure pump. Atmospheric pressure chemical ionization (APCI) and coordination ion spray (CIS) with silver ions were used as ionization modes. Compared to UV detection, the sensitivity was increased by a factor of 100. Both ionization modes are generating similar structural information. Molecular ions [M-H]+ or [M-Ag(-)] are observed in the mass spectra with exception of the saturated triglycerides for which only CIS gives intense molecular ions. The position at which the fatty acids are esterified to the glycerol backbone can be elucidated by pSFC-APCI although it remains speculative whether this is valid for highly unsaturated triglycerides because reference compounds are not available to proof this.

Atmospheric Pressure↗

Atmospheric pressure photoionization mass spectrometry.

Atmospheric pressure photoionization (APPI) is the last arrival in the family of atmospheric pressure ionization (API) methods to couple mass spectrometry (MS) to liquid-phase separation techniques. The basic idea was to further extend the fields of application of liquid chromatography (LC)-MS to those molecules that are not, or are poorly amenable, to electrospray (ESI) or APCI. The present review explores the literature. After a short introduction with an historical background and the premises for its development, we describe the technique, its physical principles, and the factors that affect its efficiency. The review also presents a survey of applications in different fields.

Atmospheric Pressure↗