The use of some electric measurements on biomechanical phenomena.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
BACKGROUND AND AIMS: Stem shape in angiosperms depends on several growth traits such as elongation direction, amount and position of axillary loads, stem dimensions, wood elasticity, radial growth dynamics and active re-orientation due to tension wood. This paper analyses the relationship between these biomechanical factors and stem shape variability. METHODS: Three apricot tree varieties with contrasting stem shape were studied. Growth and bending dynamics, mechanical properties and amount of tension wood were measured on 40 1-year-old stems of each variety during one growth season. Formulae derived from simple biomechanical models are proposed to quantify the relationship between biomechanical factors and re-orientation of the stems. The effect of biomechanical factors is quantified combining their mechanical sensitivity and their actual variability. RESULTS: Re-orientations happened in three main periods, involving distinct biomechanical phenomena: (a) passive bending due to the increase of shoot and fruit load at the start of the season; (b) passive uprighting at the fall of fruits; (c) active uprighting due tension wood production at the end of the season. Differences between varieties mainly happened during periods (a) and (b). CONCLUSIONS: The main factors causing differences between varieties are the length/diameter and the load/cross-sectional area ratios during period (a). Wood elasticity does not play an important role because of its low inter-variety variability. Differences during period (b) are related to the dynamics of radial growth: varieties with early radial growth bend weakly upward because the new wood layers tend to set them in a bent position. The action of tension wood during period (c) is low when compared with passive phenomena involved in periods (a) and (b).
PURPOSE: To better understand the mechanical behavior of healing skeletal muscle; specifically the tissue's response after acute eccentric stretch injury. METHODS: Rabbit tibialis anterior (TA) muscle tendon units were subjected to an in vivo single stretch (eccentric) injury and mechanically evaluated (constant rate elongation to failure) at 1, 3, and 7 d postinjury. In addition to a traditional linear analysis (linear stiffness and failure load), an existing nonlinear rheological model was modified to interpret the experimental load-to-failure data. The models' performance were evaluated and discussed. RESULTS: No significant injury effect was observed, either within or between groups, across the 7-d healing interval, using the linear analysis. However, interpretation of the data using our nonlinear phenomenological model identified significant changes in mechanical behavior that went undetected by linear analyses. Percent differences, between injured and contralateral control limbs, of model parameter estimates were analyzed. Nonparametric statistical analysis illustrated significant changes in the first-order stiffness (k1) throughout the 7-d healing interval. Model simulations using mean values of each parameter revealed increased low-load tissue compliance after injury, with a decrease in linear slope that recovered steadily toward control values by day 7. At 7 d postinjury, virtually no differences were observed between injured and sham control tissues. CONCLUSIONS: Our findings suggest that acute eccentric injury increases the muscle's compliance 24 h after injury, with a steady recovery to uninjured values by the 7th day, yet these changes went undetected by linear analysis. Therefore, nonlinear analysis is necessary to recognize valuable information contained in the low-load region and to quantify important biomechanical phenomena of stretch-injured healing skeletal muscle.
A simple, reproducible and reliable method is proposed for measurement of cotyloid version. Using a standing frontal image of hip, the cotyloid borders are identified and a single-plane geometric projection determines the precise degree of version. This study can also be made from a conventional frontal pelvic image with bipodalic weight bearing. Knowledge of spatial orientation allows a better approach to head-cotyle biomechanical phenomena and thus improved understanding of the genesis of certain hip diseases.
INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
The interplay between cellular, biochemical, and biomechanical phenomena which result in wound contraction is examined with the aid of a mathematical model. The model accounts for fibroblasts repopulating the wound extracellular matrix (ECM) by a combination of migration and proliferation and, in the course of exerting traction forces associated with their motility, their deformation of the local ECM, which has a viscoelastic character. A base model, which assumes that cell and tissue properties are the same irrespective of position with respect to the wound center, is found to be inconsistent with wound contraction. Extensions of the base model which account for the possible influence of a concentration gradient of an inflammation-derived mediator on the traction, growth, or chemotactic properties of the fibroblasts do predict the qualitative features of a contracting wound. In particular, the case where traction is prescribed to increase as fibroblasts approach the wound center is shown to obey the commonly observed exponential rate contraction law and to be largely consistent with the findings of McGrath and Simon (Plast. Reconstr. Surg. 72, 66, 1983) concerning the independence of the contraction rate constant and final extent of contraction from initial wound size and geometry.
For a bacterial flagellar motor driven by a proton flux, a loose coupling mechanism has been proposed in which the movement of the proton is indirectly and loosely coupled with the rotation of the motor. This mechanism assures the efficient and smooth conversion of both electrical and chemical potential energies of the proton of the same order as the energy of the thermal fluctuation. Loose coupling has been also assumed for the proton ATPase. A proton flux produces a rotational movement of protein molecules and this movement promotes the synthesis of ATP. In the proposed mechanism, the number of protons necessary for the synthesis of one ATP molecule is not an integer but varies depending on the environmental condition. In the case of muscle, the coupling between the hydrolysis of ATP and the shortening was found to be extremely loose. It is likely that molecular machines in living cells often adopt a loose coupling mechanism in which the chemical reaction and the physical cycle have not always a definite one-to-one correspondence.
Two cases of spontaneous otoacoustic emissions (SOAEs) have been found among a sample of 28 chinchilla ears after noise exposure, and no cases of SOAEs have been found among 28 unexposed ears. Further observations of the characteristics of SOAEs recorded in the ear canals of two chinchillas after noise exposure are described. These signals were tonal, robust, and could be suppressed by presenting external tones to the ear. Histopathological evaluation of the cochlea of emitting ears revealed discrete basal-turn lesions near the positions corresponding to the frequencies of the emissions. Behavioral threshold shifts measured in one animal after noise exposure and acoustic intermodulation distortion product behavior in the other both suggest a region of increased vibratory response of the cochlear partition near the location of the SOAE. Results from these emitting ears support a hypothesis that a punctate loss of the organ of Corti (OC) may facilitate the occurrence of an SOAE. We further hypothesize that the following conditions are both necessary and sufficient for an SOAE to occur: (1) functional disruption of a normally present biomechanical control mechanism in a region of the OC; (2) presence of functionally active OC (especially outer hair cells) adjacent to the region. The observations from ears possessing SOAEs provide strong, though indirect support for active and nonlinear models in interpreting cochlear biomechanical phenomena.
Explore the source record for details and available documents.
The polymeric basis for the mechanical properties of primary plant cell walls has been investigated by forming analogous composites based on fermentation of the bacterium Acetobacter xylinus, either alone or in the presence of xyloglucan or pectin. Simultaneous small-angle X-ray scattering and uniaxial deformation experiments has shown how the cellulose microfibrils reorient during deformation. Despite very different stress/strain curves, the reorientation behaviour is similar, regardless of the presence or absence of xyloglucan or pectin. A simple theory has been developed to predict the orientation behaviour. This is qualitatively similar to the measured behaviour, but differs quantitatively.
Explore the source record for details and available documents.
Many swimming bacteria are propelled by flagellar filaments driven by a rotary motor. Each of these tiny motors can generate an impressive torque. The motor torque vs. speed relationship is considered one of the most important measurable characteristics of the motor and therefore is a major criterion for judging models proposed for the working mechanism. Here we give an explicit explanation for this torque-speed curve. The same physics also can explain certain puzzling properties of other motors.
The quality of the natural vibrations of specific bacteria is investigated using a shell model which accounts for the elastic properties of the membrane and the associated viscosities of the cytoplasma and the surrounding fluid. The motion of the membrane is approximated in terms of the distribution of internal forces over the shell thickness, which is assumed to be much less than the size of the cell. Flexural moments and intersecting stresses are neglected. Using experimentally obtained values for the membrane properties, high-quality resonances are predicted for several types of bacteria which have radii greater than 5 microm. Viscous shear waves are the main source of energy dissipation as has been previously reported in other studies on the natural oscillations of red blood cells, drops, and bubbles. Implications for the acoustic mediated destruction of bacteria are discussed.
Using a new approach, we estimated the physical strength of the cell envelopes of three species of gram-negative, gas vacuolate bacteria (Microcyclus aquaticus, Prosthecomicrobium pneumaticum, and Meniscus glaucopis). Populations of cells were slowly (0.5 to 2.9 h) saturated with argon, nitrogen, or helium to final pressures up to 100 atm (10, 132 kPa). The gas phases of the vesicles remained intact and, upon rapid (1 to 2 s) decompression to atmospheric pressure, expanded and ruptured the cells; loss of colony-forming units was used as an index of rupture. Because the cell envelope is the cellular component most likely to resist the expanding intracellular gas phase, its strength can be estimated from the minimum gas pressures that produce rupture. The viable counts indicated that these minimum pressures were between 25 and 50 atm; the majority of the cell envelopes were ruptured at pressures between 50 and 100 atm. Cells in which the gas vesicles were collapsed and the gas phases were effectively dissolved by rapid compression tolerated decompression from much higher gas saturations. Cells that do not normally possess gas vesicles (Escherichia coli) or that had been prevented from forming them by addition of L-lysine to the medium (M. aquaticus) were not harmed by decompression from gas saturation pressures up to 300 atm.
Explore the source record for details and available documents.
The effects of temperature and force on the gliding speed of Mycoplasma mobile were examined. Gliding speed increased linearly as a function of temperature from 0.46 microm/s at 11.5 degrees C to 4.0 microm/s at 36.5 degrees C. A polystyrene bead was attached to the tail of M. mobile using a polyclonal antibody raised against whole M. mobile cells. Cells attached to beads glided at the same speed as cells without beads. When liquid flow was applied in a flow chamber, cells reoriented and moved upstream with reduced speeds. Forces generated by cells at various gliding speeds were calculated by multiplying their estimated frictional drag coefficients with their velocities relative to the liquid. The gliding speed decreased linearly with force. At zero speed, the force measurements extrapolated to 26 pN at 22.5 and 27.5 degrees C. At zero force, the speed extrapolated to 2.3 and 3.3 microm/s at 22.5 and 27.5 degrees C, respectively--the same speeds as those observed for free gliding cells. Cells attached to beads were also trapped by an optical tweezer, and the stall force was measured to be 26 to 28 pN (17.5 to 27.5 degrees C). The gliding speed depended on temperature, but the maximum force did not, suggesting that the mechanism is composed of at least two steps, one that generates force and another that allows displacement. Other implications of these results are discussed.
Molecular machines are tiny energy conversion devices on the molecular-size scale. Whether naturally occurring or synthetic, these machines are generally more efficient than their macroscale counterparts. They have their own mechanochemistry, dynamics, workspace, and usability and are composed of nature's building blocks: namely proteins, DNA, and other compounds, built atom by atom. With modern scientific capabilities it has become possible to create synthetic molecular devices and interface them with each other. Countless such machines exist in nature, and it is possible to build artificial ones by mimicking nature. Here we review some of the known molecular machines, their structures, features, and characteristics. We also look at certain devices in their early development stages, as well as their future applications and challenges.
A bacterial cell that has a single polar flagellum alternately repeats forward swimming, in which the flagellum pushes the cell body, and backward swimming, in which the flagellum pulls the cell body. We have reported that the backward swimming speeds of Vibrio alginolyticus are on average greater than the forward swimming speeds. In this study, we quantitatively measured the shape of the trajectory as well as the swimming speed. The trajectory shape in the forward mode was almost straight, whereas that in the backward mode was curved. The same parameters were measured at different distances from a surface. The difference in the motion characteristics between swimming modes was significant when a cell swam near a surface. In contrast, the difference was indistinguishable when a cell swam >60 microm away from any surfaces. In addition, a cell in backward mode tended to stay near the surface longer than a cell in forward mode. This wall effect on the bacterial motion was independent of chemical modification of the glass surface. The macroscopic behavior is numerically simulated on the basis of experimental results and the significance of the phenomenon reported here is discussed.