PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Catheters”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Efficacy of antiseptic-impregnated catheters on catheter colonization and catheter-related bloodstream infections in patients in an intensive care unit.

This study was conducted to evaluate the impact of central venous catheters impregnated with chlorhexidine and silver sulphadiazine on the incidence of colonization and catheter-related bloodstream infection in critically ill patients. One hundred and thirty-three patients requiring central venous catheterization were chosen at random to receive either an antiseptic-impregnated triple-lumen catheter (N=64) or a standard triple-lumen catheter (N=69). The mean (SD) durations of catheterization for the antiseptic and standard catheters were 11.7 (5.8) days (median 10; range 3-29) and 8.9 (4.6) days (median 8.0; range 3-20), respectively (P=0.006). Fourteen (21.9%) of the antiseptic catheters and 14 (20.3%) of the standard catheters had been colonized at the time of removal (P=0.834). Four cases (6.3%) of catheter-related bloodstream infection were associated with antiseptic catheters and one case (1.4%) was associated with a standard catheter (P=0.195). The catheter colonization rates were 18.7/1000 catheter-days for the antiseptic catheter group and 22.6/1000 catheter-days for the standard catheter group (P=0.640). The catheter-related bloodstream infection rates were 5.3/1000 catheter-days for the antiseptic catheter group and 1.6/1000 catheter-days for the standard catheter group (P=0.452). In conclusion, our results indicate that the use of antiseptic-impregnated central venous catheters has no effect on the incidence of either catheter colonization or catheter-related bloodstream infection in critically ill patients.

Anti-Infective Agents, Local↗

Central venous catheters coated with minocycline and rifampin for the prevention of catheter-related colonization and bloodstream infections. A randomized, double-blind trial. The Texas Medical Center Catheter Study Group.

BACKGROUND: Central venous catheters are a principal source of nosocomial bloodstream infections, which are difficult to control. OBJECTIVE: To determine the efficacy of catheters coated with minocycline and rifampin in preventing catheter-related colonization and bloodstream infections. DESIGN: Multicenter, randomized clinical trial. SETTING: Five university-based medical centers. PATIENTS: 281 hospitalized patients who required 298 triple-lumen, polyurethane venous catheters. INTERVENTION: 147 catheters were pretreated with tridodecylmethyl-ammonium chloride and coated with minocycline and rifampin. Untreated, uncoated catheters (n = 151) were used as controls. MEASUREMENTS: Quantitative catheter cultures, blood cultures, and molecular typing of organisms to determine catheter-related colonization and bloodstream infections. RESULTS: The group with coated catheters and the group with uncoated catheters were similar with respect to age, sex, underlying diseases, degree of immunosuppression, therapeutic interventions, and risk factors for catheter infections. Colonization occurred in 36 (26%) uncoated catheters and 11 (8%) coated catheters (P < 0.001). Catheter-related bloodstream infection developed in 7 patients (5%) with uncoated catheters and no patients with coated catheters (P < 0.01). Multivariate logistic regression analysis showed that coating catheters with minocycline and rifampin was an independent protective factor against catheter-related colonization (P < 0.05). No adverse effects related to the coated catheters or antimicrobial resistance were seen. An estimate showed that the use of coated catheters could save costs. CONCLUSIONS: Central venous catheters coated with minocycline and rifampin can significantly reduce the risk for catheter-related colonization and bloodstream infections. The use of these catheters may save costs.

Adolescent↗

Impact of oligon central venous catheters on catheter colonization and catheter-related bloodstream infection.

OBJECTIVE: To evaluate a new antimicrobial treatment for central venous catheters in comparison with a traditional treatment, by assessing the catheter colonization and catheter-related bloodstream infection rates in two groups of patients. DESIGN: Multiple-center, prospective randomized study. SETTING: The medical and surgical departments of ten institutions. PATIENTS: Patients requiring a central venous catheter for medical or surgical pathologies between June 2000 and November 2001. INTERVENTIONS: Patients in the control group received a conventional benzalkonium-treated double-lumen central venous catheter, while patients in the oligon group received an oligon-treated (polyurethane combined with silver, carbon, and platinum) catheter with the same characteristics. Data collection included demographics, preexisting clinical conditions, main pathology, catheter insertion, and management data. Catheter colonization was defined as the growth of > or = 15 colony-forming units in culture of catheter segments by the roll-plate method, or > or = 1000 colony-forming units for the sonication method, and catheter-related bloodstream infection was defined as isolation of the same organism from the colonized catheter and from the peripheral blood of a patient with clinical signs of bloodstream infection. MEASUREMENTS AND MAIN RESULTS: Data were obtained from 545 catheters. Of these, 132 catheters (24.2%) were positive for colonization. Patients in the oligon group demonstrated a lower risk for catheter colonization in the overall population (relative risk, 0.63; 95% confidence interval, 0.46-0.86; p = .003) and in the surgical subgroup (relative risk, 0.5; 95% confidence interval, 0.33-0.76;p = .001). Significant differences between groups were detected for coagulase-negative staphylococci and Gram-negative bacilli colonization rates. Twenty-one patients (3.8%) were positive for catheter-related bloodstream infection, without significant differences between control and oligon groups. CONCLUSIONS: Oligon treatment is effective in limiting the catheter colonization rate. Due to the limited amount of events, this study lacked the power to detect significant differences in terms of catheter-related bloodstream infection rate.

Actuarial Analysis↗

Central venous catheter sepsis with weekly catheter change in paediatric burn patients: an analysis of 221 catheters.

To document the risk of catheter sepsis associated with central venous catheter changes every 7 days in paediatric burn patients, and analysis of data collected prospectively on 234 such catheters was performed. During an 18-month period there were 301 acutely burned children admitted to a regional paediatric burn facility of whom 53, with an average burn size of 42 per cent TBSA, required 234 central venous catheters. A central venous catheter management protocol was followed which included catheter changes every 7 days. If insertion sites were clean and uninflamed, catheters were replaced by guidewire and the original catheter tip was semiquantitatively cultured. Catheters were replaced to a new site if insertion sites appeared inflamed or catheter tips grew 15 or more colony forming units. Overall, 3.2 per cent (10.9 per cent by Centers for Disease Control definition) of central venous catheters were associated with sepsis. When catheters were replaced by guidewire from one to three times, catheter sites were used for a mean of 15.6 days without an increased rate of line sepsis. There was no difference in sepsis rates between catheters placed at a new site or replaced by guidewire. There were no deaths attributed to catheter-related sepsis. We conclude that a protocol allowing for catheter change to a new site, or replacement by guidewire, every 7 days was associated with a low risk of catheter sepsis in paediatric burn patients.

Acute Disease↗

In vitro comparison of central venous catheters for aspiration of venous air embolism: effect of catheter type, catheter tip position, and cardiac inclination.

STUDY OBJECTIVE: To test the relative efficiency of balloon-tipped and plain catheters for aspiration of venous air embolism. DESIGN: The following four single-lumen central venous catheters were studied in a silastic model of the right atrium, tricuspid valve, and vena cavae: (1) the 16-gauge single-orifice catheter; (2) the 14-gauge Bunegin-Albin multiorifice catheter; (3) the 7-Fr pulmonary angiography catheter with balloon distal to orifices; (4) the 7-Fr pulmonary angiography catheter with balloon proximal to orifices. A 10% glycerol-water solution was circulated at 3.7 to 4.0 L/min. Catheter tips were positioned at 1 cm increments from -3 to +3 cm around the superior vena cava-right atrial junction with cardiac inclinations of 65 degrees and 80 degrees. Air (10 ml) was infused over 30 seconds; aspiration from the test catheter began 5 seconds later at 40 ml/min for 75 seconds. The balloon catheters were evaluated with the balloons inflated and deflated. SETTING: Experimental laboratory of a university-affiliated hospital. MEASUREMENTS AND MAIN RESULTS: Amounts of air aspirated were compared by analysis of variance and Tukey's multiple comparison, p less than 0.05, for all combinations. The 16-gauge single-orifice catheter tested best at a 65 degrees cardiac inclination with 86% of the venous air embolism recovered, while the 14-gauge Bunegin-Albin multiorifice catheter tested best at an 80 degrees cardiac inclination with 62% of the venous air embolism recovered. Both catheters functioned most efficiently at or above the superior vena cava-right atrial junction. CONCLUSIONS: This study demonstrated that efficacy of air recovery depends on catheter type, catheter tip position, and cardiac inclination. No benefit was derived from positioning the catheter tip inside the atrium or from using balloon-tipped catheters.

Catheterization, Central Venous↗

Indwelling urinary catheters in the elderly. Relation of "catheter life" to formation of encrustations in patients with and without blocked catheters.

In order to define the natural history of indwelling urinary catheters in the elderly, 50 patients aged 65 years or older were followed. Their catheters had been in place for a mean of 33.2 days. When removed, 40.4 percent were blocked or showed poor flow. After the catheters were changed, the 14-day "catheter life" was 78 percent. About half the population had blocked catheters. They had a 14-day "catheter life" of only 31.8 percent (p = less than 0.01). Patients with blocked catheters ("blockers") excreted more alkaline urine, calcium, protein, and mucin than patients without blocked catheters ("nonblockers"), but urea-splitting bacteria were no more frequent. The mortality was not significantly different. Flow of water through catheters was closely related to extent of encrustations. Encrustations formed uniformly throughout the catheter lumen except when the tip was obstructed. The distribution and number of species of microorganisms (three and a half per specimen) were virtually identical in catheter and bladder urine, but the counts in the catheter urine were more frequently greater than 100,000 cfu/ml (p = less than 0.01). Patients with blocked catheters appear to be metabolically different from patients without blocked catheters and should have their catheters changed at seven to 10 days to avoid obstruction.

Aged↗

Conversion of temporary hemodialysis catheters to permanent hemodialysis catheters: a retrospective study of catheter exchange versus classic de novo placement.

Many clinicians believe that de novo access is required when converting temporary hemodialysis (HD) catheters to long-term or permanent catheters. However, since vascular access sites are at a premium in the dialysis patient, it is important to preserve existing central venous catheters and conserve future access sites. In this retrospective study, data from 94 patients referred to interventional radiology for placement of long-term, tunneled HD catheters between July 2001 and September 2002 were reviewed. The study group consisted of 42 patients in whom the temporary catheter was exchanged for a peel-away sheath and a tunneled catheter inserted using the existing venous access site. The control group included 52 patients who received traditional de novo placement of permanent catheters. Based on available follow-up data, we report a 100% technical success rate, with 72% patency at 30 days in the study group (n = 32; mean age 58 years). By comparison, de novo catheter placement (n = 35; mean age 59 years) yielded a 100% technical success rate, with 83% patency at 30 days. The overall infection rate was 0.30 per 100 catheter-days (total 3036 catheter-days) and 0.36 per 100 catheter-days (total 3295 catheter-days), respectively (chi2 = 0.64, p > or = 0.05). There was no incidence of exit site infection, tunnel infection, or florid sepsis in either group. Likewise, no stenosis or bleeding complication was noted. Thus conversion of a temporary HD catheter to a tunneled catheter using the same venous insertion site is safe, does not increase the risk of infection, and allows conservation of other central venous access sites.

Adolescent↗

Risk of colonization of central venous catheters: catheters for total parenteral nutrition vs other catheters.

BACKGROUND: Infected central venous catheters cause morbidity and mortality. OBJECTIVE: To compare the risk for colonization of central venous catheters used for total parenteral nutrition with that of catheters used for other purposes. METHODS: Retrospective review of prospectively acquired data on 260 patients with a stay in a surgical intensive care unit longer than 3 days. Single-lumen catheters used solely for total parenteral nutrition were inserted into the subclavian vein and cared for by a dedicated team. Catheters for other purposes were placed and cared for by other staff. Catheters were cultured if clinical findings suggested infection. RESULTS: Of 854 central venous catheters, 61 (7%) were used for total parenteral nutrition. During 4712 catheter days of observation, 89 catheters of all types were colonized. Risk factors for colonization included duration of catheterization (P < .001), having 3 or more lumens (hazard ratio, 1.7; 95% CI, 1.1-2.6), pulmonary artery catheterization (hazard ratio, 1.7; 95% CI, 1.1-2.7), and placement in the internal jugular vein (hazard ratio, 1.6; 95% CI, 1.1-2.5). Catheters used for total parenteral nutrition (hazard ratio, 0.14; 95% CI, 0.04-0.57) and those in the subclavian vein (hazard ratio, 0.51; 95% CI, 0.3-0.8) were at lower risk of colonization. In a multivariate Cox model, the only significant factor was a 5-fold lower risk of infection for catheters used for total parenteral nutrition (hazard ratio, 0.19; 95% CI, 0.04-0.83). CONCLUSION: Rates of colonization were lowest for catheters used solely for total parenteral nutrition, suggesting that a team approach improves patients' care.

Aged↗

Efficacy and safety of a retrograde tunneled hemodialysis catheter: 6-month clinical experience with the Cannon Catheter chronic hemodialysis catheter.

PURPOSE: Tunneled catheters play an important role in the delivery of hemodialysis, for both temporary and long-term vascular access. Proper catheter tip positioning is critical for optimal blood flow and performance. The modular Cannon Catheter II Chronic Hemodialysis Catheter is placed tip first, then tunneled back to the exit site, in a simple technique (retrograde tunneling) that provides precise tip placement within the right atrium. This retrospective study evaluated 6-month efficacy and safety of the Cannon catheter in 38 patients. METHODS: Monthly mean flow, pressure, Kt/V, and URR were determined. Safety parameters included early and late device-related complications, device removals, and device survival. RESULTS: 87% of subjects had history of vascular access failure. Cannon catheters were inserted via an internal jugular vein with retrograde tunneling in all patients without insertional complication. Mean flow ranged from 369.0 to 404.8 ml/min, with a trend for increasing flow over time. High flow allowed delivery of correspondingly high clearance. Mean URR remained > or = 71%; mean weekly Kt/V ranged between 1.55 and 1.60, above current K/DOQI adequacy guidelines. There were no device-related hospitalizations or deaths. Catheter-related bacteremia occurred in 3 patients over the 6 months (0.62 bacteremias/1,000 patient-days), resolving through out-patient treatment. The Cannon catheter provided extended high flow vascular access (> or = 6 months or until hemodialysis catheter-based access was no longer needed) in 95% of patients. CONCLUSION: Retrograde tunneling of the Cannon Catheter II Chronic Hemodialysis Catheter allowed optimal tip placement and high flow rates, as well as safe, reliable, extended use.

Journal Article↗

Central catheter-related infections: comparison of pulmonary artery catheters and triple lumen catheters for the delivery of hyperalimentation in a critical care setting.

We prospectively studied the risk of catheter-related sepsis (CRS) in 75 critically ill patients who received total parenteral nutrition (TPN) through 158 pulmonary artery catheters (PACs) and 214 triple-lumen catheters (TLCs). We relied on semiquantitative cultures of the catheter tips, peripheral blood cultures in febrile patients and clinical response to catheter removal to diagnose catheter-related sepsis. The infection rate was 2.5% (4/158) of PACs and 6.5% (14/214) of TLCs (p = 0.124). Colonization rates were 29.1% for PACs and 32% for TLCs. PACs were left in place a significantly shorter length of time than TLCs, 3.1 vs 5.1 days (p less than 0.005). Guidewire exchanges and subclavian vein insertions were associated with a decreased rate of CRS when compared to new insertions and internal jugular vein insertions, respectively. We conclude that pulmonary artery catheters can be used safely for the delivery of hyperalimentation in critically ill patients with no increased risk for catheter-related sepsis compared to triple-lumen catheters. The use of the PAC in this manner allows for the use of a single central venous catheter for the delivery of hyperalimentation and hemodynamic monitoring.

Adult↗

Central catheter infections: single- versus triple-lumen catheters. Influence of guide wires on infection rates when used for replacement of catheters.

A prospective study was conducted over six months to determine if triple-lumen catheters were associated with a higher rate of infection than single-lumen catheters. A total of 502 central intravascular catheters were prospectively collected from 362 consecutive patients in the adult intensive care units. Semiquantitative and broth cultures were performed on distal and proximal catheter segments, with peripheral blood culture specimens drawn in febrile patients. The overall infection rate for the 502 catheters was 11.8 percent or 2.2 infections per 100 days at risk. The infection rates were: single-lumen lines, 8 percent; triple-lumen lines, 32 percent; and triple-lumen pulmonary artery catheters, 12 percent. When corrected for time at risk, the triple-lumen lines and the triple-lumen pulmonary artery catheters had the same rate of infection, which was three times greater than that of the single-lumen catheters. After correction for confounding variables such as the presence of diabetes mellitus, the use of hyperalimentation, the degree of illness, dialysis, or ultrafiltration, and the use of a guide wire to place a replacement line over a pre-existing one, the risk of infection remained significantly higher for triple-lumen than for single-lumen catheters. The use of a guide wire to place a new line over an old one also was associated with a trend towards an increased risk of infection.

Adult↗

Peritoneal catheter development. Currently used catheters--advantages/disadvantages/complications, and catheter tunnel morphology in humans.

Original Tenckhoff catheters are still the most commonly used catheters, and catheter survival rates are still unsatisfactory. Preliminary results with Swan Neck catheters, the catheters with a permanently bent intramural segment, are encouraging since these catheters are associated with low complication rates. The role of the external cuff in prevention of exit and tunnel infections is still controversial. Animal experiments indicate that collagen ingrowth into the external cuff is crucial in the inhibition of epidermal downgrowth. The author's recent preliminary observations on four catheter tunnels removed 1 month to 5.5 years after catheter implantations, indicate that 1) epidermal cells in humans do not spread deeper than a few millimeters from the skin exit and 2) the external cuff does not participate in the epidermal cell downgrowth inhibition. This is unlike animal studies. The difference in epidermal biology between humans and animals may render animal experiments difficult to apply to catheter technology in humans.

Animals↗

Catheter-associated infections in urology: possible use of silver-impregnated catheters and the Erlanger silver catheter.

Indwelling urinary catheters play a very important part in urology. However, their use is accompanied by a considerable increase in the risk of nosocomial urinary tract infections. The pathophysiological cause is ascribed to pathogens that adhere to the catheter surface, proliferate and produce a biofilm. In addition to aseptic techniques, modification of the catheter material to confer antimicrobial activity plays an essential part in the prevention of catheter-related urinary tract infections. The antimicrobial efficacy of silver against gram-positive and gram-negative bacteria is well known and amply shown in vitro. The efficacy of silver-impregnated catheters is critically dependent on both the chemical structure of the incorporated silver and the way the silver has been combined with the basic catheter material. Hence, clinical studies on silver-modified catheters have so far given inconsistent results. The new technology of the Erlanger silver catheter offers the opportunity of an effective reduction in catheter-related infections.

Anti-Bacterial Agents↗

Success rate of catheter ablation in atrial flutter: comparison of a 4- or 5-mm tip electrode catheter with an 8-mm tip electrode catheter.

BACKGROUND: Radio frequency (RF) energy is capable of interrupting the reentrant circuit of atrial flutter and curing the arrhythmia. The development of 8-mm tip catheter provides more tissue damage and has offered the promise of improved success. The purpose of our study was to determine if the acute and long-term success with the 8-mm tips were superior to the 4- or 5-mm tips. MATERIALS AND METHODS: The outcomes of the first 20 patients in whom an 8-mm tip catheter was used were compared with the previous 20 patients in whom a 4-or 5-mm tip catheter was used. Procedural (acute) ablation success was defined by creation of bi-directional isthmus block. Long-term success was defined as the prevention of clinically evident atrial flutter (AFl) as determined by the absence of symptoms or maintenance of sinus rhythm on electrocardiogram, six months to one year after the procedure. RESULTS: Compared to the 4- or 5-mm tip, the 8-mm catheter tip was associated with a reduced ablation duration {22.3 +/- 16 versus 11.5 +/- 5 min (p = 0.0078)}, a lower mean number of ablations {13.5 +/- 9.9 versus 6.8 +/- 2.9 (p = 0.0065)} and a reduced procedure time {1.8 +/- 0.7 versus 1.1 +/- 0.5 h (p = 0.0032)}. Acute success was 95% in the 4- or 5-mm group versus 80% in the 8-mm group (p = NS), but long-term success was higher in the 8-mm group than the 4- or 5-mm group (87.5 versus 63.2%, p = 0.0436). CONCLUSIONS: Eight-millimeter tip catheters for AFl shorten procedure time, reduce the duration and number of ablations and accomplish bi-directional block when compared with smaller tipped catheters. The long-term success rate is better with the 8-mm tips and should be the preferred catheter for RF ablation of AFl.

Aged↗

Reduced catheter sepsis and prolonged catheter life using a tunnelled silicone rubber catheter for total parenteral nutrition.

One hundred and five patients were given total parenteral nutrition (TPN) for an average of 15 days via centrally placed venous catheters. Thirty-seven polyvinyl chloride (PVC) and 80 silicone rubber catheters were used. All the silicone rubber and 8 of the PVC catheters were buried in a subcutaneous tunnel. When silicone rubber catheters were used, there was significantly less catheter sepsis (P much less than 0.01), catheter life was prolonged by 50 per cent and fewer catheter insertions per patient were necessary.

Catheterization↗

Do multi-lumen catheters increase central venous catheter sepsis compared to single-lumen catheters?

Triple-lumen catheters (TLC) are now routinely used in critically ill and multiply injured patients who require multi-port central venous access. An apparent rise in catheter contamination and catheter-related sepsis (CRS) occurred in patients receiving total parenteral nutrition (TPN) through a TLC as opposed to a single-lumen catheter (SLC). A prospective study was performed to determine rates of catheter contamination and CRS in multiple trauma and general surgical-medical patients who received TPN through TLC's and SLC's. Three hundred seven TLC's and 68 SLC's were placed in 234 patients during a 12-month period. There was no statistically significant difference in the rate of contamination or CRS between the two groups although there was a trend toward increased CRS and contamination in the TLC group. TLC's may be used for short-term administration of TPN without significant increase in catheter contamination or CRS.

Bacterial Infections↗

A rare complication of a central venous catheter system (Port-a-Cath). A case report of a catheter embolization after catheter fracture during power training.

A 36 year old patient received an implantable central venous catheter system for a bone marrow transplantation. One year after the successful transplantation, embolization of the catheter was discovered by a routine x-ray three weeks after beginning of an exercise program with a spring expander including arm exercises. The catheter was removed without further complication via the vena femoralis. We assume that the cause for this incident was material fatigue due to pressure between clavicula and first rib possibly caused by strength training. We suggest as a consequence that patients with an implanted catheter system should before starting exercise consult a sports medicine specialist who would in turn cooperate with the specialist responsible for the catheter, so that an adequate and safe training program can be selected.

Adult↗

Temperature-controlled irrigated tip radiofrequency catheter ablation: comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate.

INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures < 60% partly due to the limited lesion size after conventional radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion size, but has increased risk of cratering. The present study explores irrigated tip catheter ablation in temperature-controlled mode, target temperature 60 degrees C, using an irrigation rate of 1 mL/min, comparing this to conventional catheter technique, target temperature 80 degrees C. METHODS AND RESULTS: In vivo anesthetized pigs were ablated in the left ventricle. In vitro strips of porcine left ventricular myocardium were ablated in a tissue bath. Lesion volume was significantly larger after irrigated tip ablation both in vivo (544 +/- 218 vs 325 +/- 194 mm3, P < 0.01) and in vitro (286 +/- 113 vs 179 +/- 23 mm3, P < 0.001). The incidence of cratering was not significantly different between the two groups. In vivo, no coagulum formation on part of the catheter tip was seen after irrigated tip ablation as opposed to 52% of the applications with conventional ablation (P < 0.05). CONCLUSION: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip.

Animals↗