PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Cathode Ray Tube”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Evaluation of biopolymer-modified concrete systems for disposal of cathode ray tube glass.

Cathode ray tubes (CRTs) from computer monitors and television sets, which contain significantly high percentage of lead (Pb) by weight, represent an enormous and growing hazardous waste problem in the United States and worldwide. As a result, new technologies are needed to cope with current CRT waste stream and increased hazard and build new markets for its recycled components, developing commercially viable concrete composites, as well as minimizing CRT disposal problems. In this study, commercially available biopolymers, such as xanthan gum, guar gum, and chitosan, were used to encapsulate CRT glass waste, reducing the Pb leachability. The biopolymers utilized contain a number of useful functional groups, such as carboxyl (xanthan), hydroxyl (guar), and amino groups (chitosan), which play important roles in binding and stabilizing Pb onto concrete structures. The use of biopolymers in concrete systems can create a stable interpenetrating cross-linking composite that will last for many years. Results from these new composites show 30% higher compressive strength than standard concrete and a sharp decrease in lead leachability from several thousand milligrams per liter initially to an amount of three-tenths milligrams per liter or lower values (much lower than the U.S. Environment Protection Agency standard for hazardous waste of 5 mg/L by the toxicity characteristic leaching procedure test), and for some of the composites leachability is below even the standard for drinking water. This efficient and cost-effective CRT-biopolymer-concrete composite is a new class of biopolymer-modified material that can potentially perform a significant role in relieving the current CRT issue.

Biopolymers↗

Comparison of conventional fluorescein angiography film images with a cathode ray tube display.

We evaluated the effectiveness of cathode ray tube (CRT) displays in the transfer of diagnostic information to the ophthalmologist. Retinal fluorescein angiography images were used and data were taken using the receiver operating characteristic experimental paradigm. Three ophthalmologists with experience ranging from two to 12 years participated in the study. Sixty-eight images were selected from proof sheets of 800 original images. Next, these images were digitized, then each set was shown on its respective display (slide projection for the proof sheet images and CRT for the digital images). These 68 images were from a variety of patients and represented a broad range of normal and abnormal retinas (including diabetic retinopathy, hypertension independent of diabetes, and sickle-cell disease). Results show (1) that there is no difference between the systems in terms of diagnostic accuracy; (2) that certainty of diagnosis was not a function of the system; and (3) that although there was an effect due to experience of the ophthalmologist, it did not affect diagnosis accuracy. We conclude that CRT displays at conventional video resolutions can deliver the needed diagnostic information as well as film. We also hypothesize that digital enhancement techniques can increase the available diagnostic information beyond that of film.

Computer Systems↗

Cathode-ray tube displays for medical imaging.

This paper will discuss the principles of cathode-ray tube displays in medical imaging and the parameters essential to the selection of displays for specific requirements. A discussion of cathode-ray tube fundamentals and medical requirements is included.

Data Display↗

Radioactivity in cathode ray tubes.

While surveying used computer equipment out of a zone posted as a Contamination Area, 100% of the computer monitors surveyed had levels of radioactivity that were significantly above background. The radioactivity was primarily on the front face of the cathode ray tube and was not amenable to decontamination. Hot spots were found also along the edges and seals of the cathode ray tube. Similar surveys of computer monitors that were never in Contamination Areas confirmed that radioactivity was incorporated into the monitor. Surveys were made of recently manufactured television sets with similar results. Gamma spectroscopy indicates that the radioactivity is due to naturally occurring radioactive materials. Since most surveys of cathode ray tubes in the literature were made while the units were energized and indicated low-energy x-rays, the use of naturally occurring radioactive materials in the manufacture of cathode ray tubes has not been widely recognized. This paper presents the results of these surveys, the results of gamma spectroscopy, and a method for releasing existing computer equipment having naturally occurring radioactive materials.

Beta Particles↗

Cathode-ray-tube monitor artefacts in neurophysiology.

We demonstrate that cathode-ray-tube (CRT) monitors commonly used as stimulus generators in visual neuroscience produce signal artefacts. This arises from two factors, one being the finite time needed for the raster scan of the CRT to cross the receptive field being stimulated, and the other being the restraint imposed by the impulse response of the phosphor itself. Together these factors result in smearing or blurring that manifests as high frequency noise, distorting the desired signal applied by the investigator. Our analysis identifies those conditions that promote these artefacts and we describe methods for their minimisation. We suggest that a monitor frame rate >/=100 Hz provides a reasonable trade-off between refresh and the generators of high frequency noise.

Artifacts↗

Colored focal visual evoked potentials by cathode ray tube versus scanning laser ophthalmoscope.

We compared the focal visual evoked potentials obtained in 52 young subjects with normal vision, evoked by means of three alternating black/color checkerboards generated by a trichromic cathode ray tube (dominant wavelength, 514 nm; colorimetric purity, 0.45) and by means of a scanning laser ophthalmoscope (argon laser beam, 514 nm; colorimetric purity, approximately 1). These three checkerboards, with an area of 3.5 degrees x 3.5 degrees (stimulating the fovea), then with an area of 3.5 degrees x 3.5 degrees with a central exclusion of 1.5 degrees x 1.5 degrees (stimulating the perifoveola) and finally with an area of 1.5 degrees x 1.5 degrees (stimulating the foveola) were presented within a field (8 degrees x 8 degrees) of homogeneous luminance of 170 cd/m2 and 1500 cd/m2, respectively. Their check sizes were 30', with a reversal temporal frequency of 0.75 Hz. The transient focal visual evoked potentials recorded with these three stimuli generated by the two types of stimulators were clearly detected for at least 85% of subjects. Their characteristics (waveform, amplitude and culmination times of the different waves) were comparable, regardless of the stimulator used (cathode ray tube or scanning laser ophthalmoscope). These results suggest that, under these various conditions of luminance and colorimetric purity, the neurophysiologic circuits tested function in identical ways. The focal visual evoked potential signs, now clearly defined by means of stimuli generated by cathode ray tubes, therefore apparently can be applied to the focal visual evoked potential evoked by stimuli generated by the scanning laser ophthalmoscope.

Adult↗

The characterization of waste cathode-ray tube glass.

New re-use applications are needed to address the relatively large quantity of waste electronic products generated in the world. Cathode-ray tubes (CRTs) from computer monitors and TV sets are a large component of such waste. The three glass components of CRTs are the funnel, panel and neck, which are produced by various manufacturers and are now collected by asset-recovery centres. In this paper, we characterize waste funnel and panel glass from dismantled cathode-ray tubes with a view to assisting the development of new re-use applications. The heavy metal (lead, barium, and strontium) content of such glass represents an acute risk to the environment. Our results of the chemical composition for different kinds of waste CRT glass including black & white and color CRTs show that CRT glass from different producers have generally similar chemical compositions. In particular, the compositions of funnel and panel black & white CRT glass are similar, but are different to those of panel and funnel color CRT glass. We also measured the following specific properties of each type of CRT glass: density, glass transition temperature, and linear coefficient of thermal expansion. It was found that the coefficients of thermal expansion of CRT glass do not vary with their composition. In contrast, the measured densities and glass transition temperatures do vary with composition. On the basis of our experimental data and data found in the literature, we outline the main properties of several waste CRT glass currently in circulation. The aim of this study was to provide the data required to determine if this kind of waste could be entirely (or partially) re-used and to aid the search for promising methods of treatment.

Computer Terminals↗

Glass-ceramics obtained by the recycling of end of life cathode ray tubes glasses.

This work is concerned with open-loop recycling of end of life Cathode Ray Tubes glass (an unsolved problem when considering that in Europe almost 90% of EOL electronic goods is disposed of in landfills), focusing on the development of glass-ceramics from panel or funnel glass with dolomite and alumina, and the evaluation of the tendency towards crystallisation with particular attention on composition and thermal treatment. Glasses were melted at a temperature of about 1500 degrees C and transformed into glass-ceramics by different thermal treatments (900 degrees C to approximately 1100 degrees C temperature range and 0.5 to approximately 8h soaking time). By using the evaluation of thermal, mineralogical and microstructural data it has been pointed out that a good degree of crystallisation is reached at about 1000 degrees C and with a high proportion of waste glass (50-75%) if 40-45% of CaO and MgO bearer (dolomite) is introduced. In this way alkaline and alkaline-earth silicate and aluminosilicate mainly develop probably with a surface mechanism.

Ceramics↗

Recycling of scrap cathode ray tubes.

It is estimated that approximately 50% of the weight of a computer monitor is composed of cathode ray tube (CRT) glass. Thus, the successful recycling of scrap CRT glass can greatly relieve the disposal problem created by scrap monitors. CRT glass may be considered a hazardous waste due to its high lead concentration. A CRT can be divided into panel (front) glass and funnel (back) glass. Several coatings have been applied to the surface of the CRT panel and funnel glass. These coatings may present an adverse effectto the environment by obstructing the recycling and reuse of the CRT glass. To recycle CRT glass, a series of tests has been conducted to remove the coatings from scrap CRT glass. In this study, the CRT panel and funnel glass obtained from scrap computer monitors was cleaned by wet-scrubbing and ultrasonic cleaning methods. This cleaned CRT glass is intended to be recycled and reused by CRT manufacturers. This study shows that the wet-scrubbing method has a better coating removal performance and no associated pollution problem (i.e., no additional chemical additives). Thus, the wet-scrubbing method is recommended for use as a CRT coating removal method. The results of these tests are presented in this paper.

Beta Particles↗

Comparison of a cathode-ray-tube and film for display of computed radiographic images.

The goal of the study was to compare a cathode-ray-tube (CRT) digital display with film by using task-dependent image quality assessment methods. Contrast-detail analysis was utilized. Human observers performed a simple detection task, specifically, detecting a pillbox target in a uniform Poisson field, using either film or a digital display that employed a CRT monitor. Observers performed equally well on both film and CRT when the window settings of the digital display were established subjectively by a radiologist. Changing the window settings of the digital display to match the average background luminance of a film-illuminator combination decreased the luminance contrast of the targets and observer performance was reduced, though these effects were probably not linked. The "gold standard" film had lower luminance contrast than the CRT displayed images, yet observer performance was never lower for film than for the CRT. Therefore we concluded that luminance contrast was not a limiting factor for observer performance in this study. The CRT monitor changed fairly rapidly after it was calibrated. During a period of six months the gamma of the display increased from 1.82 to 2.42 and the maximum luminance decreased from 319 to 228 cd/m2. Low luminance output demonstrated a larger percentage decrease (approximately equal to 85%) than high luminance output (approximately equal to 29%) over the same time period. These observations suggest that standard window settings should be reviewed from time to time to ensure that the display is used optimally. No special look-up table setup such as perceptual linearization was used.

Calibration↗

Raster-scan cathode-ray tubes for vision research--limits of resolution in space, time and intensity, and some solutions.

Raster-based cathode-ray tubes (CRTs) are increasingly used for stimulus presentation. While very flexible, their design based on consumer electronics can limit their value in vision research. Here their limitations of resolution in time, space, intensity and wavelength are systematically compiled. Often, ingenious ideas can circumvent such limitations for specific experiments. Some ad-hoc solutions, as well as the more general techniques of dithering and anti-aliasing, are presented.

Artifacts↗

Cathode ray tube glass recycling: an example of clean technology.

In this study the use of 'cleaned' end of life (EOL) cathode ray tube (CRT) glass as a raw material in ceramic glazes is described. At present, the recycling and industrial utilization of CRT, a glass material from TV and computer sets, is a subject of intense research with particular regard to the so-called open-loop recycling, namely cycles different from that of the origin. However, the use of CRT glass as a secondary raw material is strictly related to the demand of high-quality raw material. The good preliminary results reached by introducing clean TV and PC monitor panel and cone glass into ceramic glaze formulations pushed research toward the setting-up of a base glaze that is exploitable for the production of pigmented, silk-screened and flame-hardened glazes (products used industrially for coating floor tiles). The aesthetic and chemical characterization of the tiles glazed by this product showed an extremely similar behaviour to originals that did not contain CRT glass. The good technical results achieved have been supported by the life cycle assessment analysis, which has demonstrated a reduction of the environmental impact of the CRT glass-containing ceramic glaze with respect to the standard one.

Beta Particles↗

Calibration of medium-resolution monochrome cathode ray tube displays for the purpose of board examinations.

This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.

Calibration↗

Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.

The purpose of the study was to compare the detection performance of a cathode ray tube (CRT) monitor versus a liquid crystal display (LCD) monitor for simulated subtle pulmonary lesions. Ten templates containing simulated lung lesions were superimposed on an anthropomorphic chest phantom. Posteroanterior radiographs were obtained using flat panel technology and were displayed on a CRT and an LCD monitor. Image processing and reading conditions were equivalent for both softcopy displays. Five observers assessed lesion detectability using receiver-operating characteristic (ROC) methodology. A multivariate test (Pillai trace) was used to test the significance of differences (P<0.05). The multivariate test revealed significantly different detection rates for the lesion types, but no significant difference between the two display modes. Detection performance for both monitors was higher for nodules and micro-nodules and lower for lines and patchy opacities. Analysis of lesion subgroups according to their location in lucent/obscured lung areas was also not statistically significant. Under ideal reading conditions, CRT and LCD displays perform equivalently for the detection of simulated subtle pulmonary lesions.

Data Display↗

A note on luminance calibration of raster-scan cathode-ray tubes: temporal resolution, ripple, and accuracy.

Accurate luminance calibration is an important issue for stimuli in vision research. Raster-scan cathode-ray tubes present a rapidly scanning spot with a luminance of the order of 10,000 cd m-2 (the actual value depends on video timing and phosphor persistence). With little spatial integration this may result in overloading of the front stage of a photometer. More importantly, even if averaged over hundreds of milliseconds, the pulsed nature of the luminance signal will markedly reduce accuracy of the luminance measurement. A frame-synchronised photometer is described to increase measurement accuracy whilst still rapidly acquiring the result.

Computer Terminals↗