PubMed HealthSearch

SEARCH · PubMed Health

Results for “Comparative Study”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Robotic-assisted transbronchial biopsy versus computed tomography-guided transthoracic needle biopsy for peripheral pulmonary lesions: a systematic review and meta-analysis of direct comparative studies.

Robotic-assisted bronchoscopy (RAB) and computed tomography-guided transthoracic biopsy (CTTB) are competing strategies for sampling peripheral pulmonary lesions (PPLs). Whether they differ in yield or safety is uncertain. To our knowledge, this is the first systematic review restricted to direct comparisons. We searched MEDLINE, Europe PMC, Scopus, Web of Science and ClinicalTrials.gov from inception to 7 July 2026 for studies directly comparing RAB with CTTB in adults with PPLs. The primary outcome was strict 2024 American Thoracic Society/American College of Chest Physicians diagnostic yield. Risk of bias was assessed with ROBINS-I and certainty with GRADE. A cohort-genealogy step identified, per outcome, the largest set of cohorts sharing no patients; only that set was pooled, with Hartung-Knapp and Mantel-Haenszel sensitivity analyses. Five retrospective studies from one US health system were eligible. Four share patients; at most three cohorts are mutually independent. Across those three, diagnostic yield was comparable (risk ratio [RR] 0.99, 95% confidence interval [CI] 0.93-1.06; I²=24%; Hartung-Knapp 0.87-1.13), with an identical relative effect under strict and intermediate definitions although absolute yields fell from 88% to 74-84% under strict criteria. Pneumothorax requiring a chest tube and/or admission was about three-quarters less frequent with RAB across all three cohorts (RR 0.25, 95% CI 0.14-0.46; I²=0%; Hartung-Knapp 0.07-0.96). Strict yield (RR 0.99) and any pneumothorax (RR 0.06) were reported by two cohorts each and neither survives the few-studies correction. RAB took about 50 min longer than CTTB where same-session staging endobronchial ultrasound was counted in the robotic time, but only about 8 min longer than CTTB where it was not. Only one cohort reported yield by lesion size category and none reported yield by bronchus sign or lung zone, so lesion-level subgroups could not be pooled. Certainty was low for pleural complications and very low elsewhere. Low-certainty evidence indicates that RAB is associated with fewer pleural complications, with no statistically detectable difference in diagnostic yield; equivalence was not formally established. Because all evidence is retrospective, confined to one health system, and almost never stratified by lesion size or accessibility, these findings are hypothesis-generating and require a multicenter randomized trial.

Humans

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 ± 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 ± 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 ± 4.45 vs 46.93 ± 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 ± 5.96 vs 39.27 ± 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 ± 0.507) compared with the laser group (0.07 ± 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 ± 0.19 vs 1.55 ± 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Evaluating Patient Satisfaction and Oral Health Impact Profile-14 (OHIP-14): A Multicenter Crossover Study Comparing Selective Pressure Impression Conventional Dentures with Mucostatic Digital Dentures.

PURPOSE: To compare patient satisfaction and oral health impact between individuals receiving complete dentures made by digital methods and those using conventional techniques. MATERIALS AND METHODS: In this randomized crossover clinical trial, 23 patients aged 40 years and older with completely edentulous arches were enrolled at three treatment centers. Each participant received two sets of complete dentures: one set created using conventional methods (selective pressure impression) and the other through digital techniques (mucostatic digital impression). The order of denture placement was randomized, with each set used for 4 weeks. A trained specialist administered treatments alongside research tools, including a general information questionnaire, a denture satisfaction survey, and the OHIP-14 interview tool. Statistical analysis was conducted using Mann-Whitney U test. RESULTS: Participants with digital dentures reported significantly higher satisfaction regarding treatment duration, comfort, confidence, chewing ability, esthetics, and overall satisfaction compared to those with conventional dentures. There were no significant differences in satisfaction concerning speech and pronunciation. Overall, the oral health impact on quality of life was similar between denture types, but participants indicated improved quality of life while using dentures compared to being edentulous. CONCLUSIONS: Patients with digital dentures exhibited greater satisfaction across various domains compared to those with conventional dentures, despite similar satisfaction levels in speech and pronunciation. The impact on quality of life was comparable between both types, as measured by the OHIP-14.

Humans

Can ChatGPT Replace Human Clinical Coders? A Comparative Study in Otology Billing.

OBJECTIVE: Evaluate the utility of the large language model (LLM), ChatGPT, for the analysis of operative notes and the generation of Current Procedural Terminology (CPT) codes in comparison to human clinical coders. STUDY DESIGN: CPT billing codes assigned by ChatGPT were compared to existing billing data. Otology practice within a tertiary academic center. METHODS: About 191 operative notes from a single surgeon (9/2022-10/2023) were analyzed. ChatGPT-3.5 and 4 models were prompted for CPT codes based on operative notes. Assessment included determining exact and partial match rates, sensitivity and specificity for targeted procedures, and work Relative Value Units (wRVU) differences between ChatGPT-generated and human-assigned codes. RESULTS: ChatGPT-3.5 achieved exact matches in 22% of cases and partial matches in 32%, while ChatGPT-4 achieved 14% exact and 33% partial matches. When cochlear implantation (CI) was excluded, performance dropped significantly. For CI, ChatGPT-3.5 demonstrated a sensitivity of 94% and specificity of 90%, while ChatGPT-4 showed a sensitivity of 96% and specificity of 92%. In contrast, performance on cartilage grafting was poor, with sensitivities of 4.2% for ChatGPT-3.5 and 0% for ChatGPT-4. ChatGPT-3.5 and 4 showed moderate CPT code matching accuracy among themselves, with slight agreement to human coders. Both models tended to underbill for wRVUs compared to human coders, with significant differences in the values generated. CONCLUSION: This study assessed ChatGPT's effectiveness in automating CPT code assignment for otologic surgeries. While the models achieved high sensitivity values for assigning codes related to cochlear implantation, both models struggled with complex cases, failed to apply modifiers, and often assigned fewer wRVUs. The findings highlight ChatGPT's potential in medical billing but indicate a need for further refinement.

Humans

A prospective crossover study comparing ICCS-recommended and Palmer-adjusted filling rates in children with spina bifida.

OBJECTIVE: This study aimed to investigate whether the maximal cystometric capacity (MCC) in children with spina bifida (SB) is indeed lower, as predicted by the Palmer formula, and to evaluate the impact of different bladder filling rates on urodynamic parameters. MATERIALS AND METHODS: This prospective, randomized, two-sequence crossover-controlled study included 70 children aged 3-18 years with spina bifida under regular follow-up. In Group 1, the first two bladder fillings were performed at the ICCS-recommended rate, and the third at 75% of that rate (Palmer formula). In Group 2, the sequence was reversed. Urodynamic parameters, including maximal cystometric capacity (MCC), bladder compliance, detrusor activity, filling pressures, and detrusor leak point pressure (DLPP), were analyzed across fillings. RESULTS: Cystometric bladder capacity was lower during fillings performed at the Palmer-adjusted rate compared with those at the ICCS-recommended rate. The proportion of reduced compliance significantly decreased in Group 1 (p = 0.046) but remained unchanged in Group 2. A significant positive correlation was observed between expected bladder capacity (EBC) and measured MCC in both groups (ρ ≈ 0.5-0.6). The highest correlation and agreement were found in Group 1 during the third filling at the Palmer rate (ICC = 0.606). No significant intra- or intergroup differences were observed in detrusor pressure, end-filling pressure, DLPP, or overactive bladder prevalence. CONCLUSION: Bladder filling rate was associated with differences in both cystometric capacity and bladder compliance in children with spina bifida. Fillings performed according to the Palmer formula (approximately 75% of the ICCS-recommended rate) were associated with capacities that more closely approximated age-expected values and with modest differences in bladder compliance. Conversely, faster filling rates did not produce similar benefits. These findings suggest that slower filling strategies may improve measurement consistency and agreement with expected bladder capacity estimates. However, the magnitude and direct clinical impact of these differences should be interpreted cautiously, particularly in light of the potential influence of sequence-related effects.

Humans

Comparative Studies on Bulky DNA Damage Binding by Nucleotide Excision Repair Proteins Using Surface Plasmon Resonance, Differential Scanning Fluorometry, and DNase I Footprinting.

Nucleotide excision repair is a crucial cellular mechanism that ensures genomic stability, thereby preventing mutations that can lead to cancer. The human XPC and its yeast ortholog Rad4 protein complexes are central to this process and were the focus of the study. We used surface plasmon resonance and differential scanning fluorimetry to study the binding characteristics of XPC and Rad4 when bound to the bulky cluster di-FAAF-containing 55-mer duplex DNA. Our findings revealed that XPC binds 10 times more significant affinity to control and di-FAAF-modified DNA than Rad4 with greater protein-DNA interactions. Differential scanning fluorimetry indicates that Rad4 causes comparatively more significant conformational changes upon complexation with the damaged DNA. We conducted DNase I footprinting of the Rad4/DNA complex for the first time by determining the regions protected from DNase I digestion. The DNA at the lesion is entirely resistant to digestion by DNase I in the absence of Rad4 several nucleotides to the 3'-side of the first FAAF lesion. The lack of DNase I cleavage at the lesions did not change upon adding Rad4. However, in the presence of Rad4, a footprint is observed on the 7-nucleotide region (5'-TGGTGAT-3') of the complementary strand to the 3' side of the lesion.

Surface Plasmon Resonance

Enhancing detection of polygenic adaptation: a comparative study of machine learning and statistical approaches using simulated evolve-and-resequence data.

BACKGROUND: Detecting signals of polygenic adaptation remains a significant challenge in population genomics, as traditional methods often struggle to identify the associated subtle, multi-locus allele-frequency shifts. Here, we introduced and tested several novel approaches combining machine learning techniques with traditional statistical tests to detect polygenic adaptation patterns in time-series of allele frequency changes from whole genome data. We implemented a Naive Bayesian Classifier (NBC) and One-Class Support Vector Machines (OCSVM), and compared their performance against the classical Fisher's Exact Test (FET). Furthermore, we combined machine learning and statistical models (OCSVM-FET and NBC-FET), resulting in 5 competing approaches. The framework is mainly designed and validated for evolve-and-resequence (EaR) experimental designs, where defined selection pressures and temporal sampling are feasible, but might be applicable for certain natural experiments as well. RESULTS: Using a simulated dataset based on empirical C. riparius Pool-Seq data, we evaluated methods across evolutionary scenarios varying in generation, selection strength, and number of loci under selection. Our results demonstrate that the combined OCSVM-FET approach consistently outperformed competing methods, achieving the lowest false positive rate, highest area under the curve, and high accuracy. The performance peak aligned with what we term the 'late dynamic phase' of adaptation - the period after initial selection has occurred but before fixation - highlighting the method's sensitivity to ongoing selective processes. CONCLUSIONS: Furthermore, we emphasize the critical role of parameter tuning, balancing biological assumptions with methodological rigor. While broader applicability remains an important direction for future work, the present benchmarking is intentionally scoped to EaR experimental contexts.

Machine Learning

A comparative study highlights superiority of LSTM in crop genomic prediction.

We systematically evaluated three key determinants affecting prediction accuracy and the algorithm performance differences based on fifteen state-of-the-art GP methods, and found LSTM suitable for capturing additive and epistatic effects. Genomic prediction (GP) has been developed as an important method supporting crop breeding. By utilizing the phenotype values result from GP, breeders could make decisions in the seedling stage that consequently benefit for cost saving. In recent years, machine learning emerged as an efficient technology to solve modeling problems in many fields, including crop breeding. However, numerous modeling approaches have hindered the application of GP since breeders struggle to choose. Therefore, a comprehensively methodological research with guiding significance is extremely necessary. In the present study, we systematically evaluated three key determinants affecting prediction accuracy and the algorithm performance differences based on fifteen state-of-the-art GP methods. As for genomic feature processing, we found feature selection (SNP filtering approach) performed better than feature extraction (PCA method). Specifically, the feature relationship dependent methods (GBLUP, RNN, and LSTM) as well as DNN architecture showed superior performance with feature selection. Marker density analysis showed positive correlation with prediction accuracy in a limited threshold. Comparison on effect of population size demonstrated a positive correlation between trait genetic complexity and the optimal population size required. By testing fifteen modeling methods, we found LSTM network displayed superior performance, achieving the highest average STScore (0.967) across six datasets. Further research using all cell states or the latest cell states of LSTM inputs demonstrated its architecture particularly adept with capturing additive and epistatic QTL effects among SNPs. In conclusion, our findings provide basic principles for implementing GP in breeding project to maximize prediction accuracy while maintaining cost-effectiveness.

Plant Breeding

Evaluation of metabolic, reproductive, and gut microbiota alterations in a comparative study of different preclinical models of polycystic ovary syndrome.

Polycystic ovary syndrome (PCOS) is a multifaceted, complex metabolic and endocrine disease where gut flora is considered an important factor in causing PCOS. This study aimed to identify a suitable PCOS model that contributes to gut microbial dysbiosis and metabolic and hormonal disturbances. Prepubertal SD rats were administered with normal control (NC), dihydrotestosterone (DHT), DHT with fructose (F), DHT+ high fat diet (HFD) for 91 days, dehydroepiandrosterone (DHEA), DHEA with fructose, DHEA with HFD for 30 days, sodium valproate (SV), sodium valproate with fructose, and sodium valproate with HFD for 21 days. The estrous cycles were assessed over this timeframe. At the end of the experiment, superoxide dismutase and uterine and ovarian morphology were evaluated, along with hormone levels, lipid profiles, and 16S rRNA genomic sequencing. All models exhibited PCOS characteristics, including hormonal imbalances, insulin resistance (p ≤ .001), multiple follicular cysts on ultrasonography, and histological alterations. Gut microbial dysbiosis was observed across all PCOS-induced groups; however, the DHT alone group showed more pronounced alterations in microbial composition than the other experimental groups. Specifically, the DHT alone group exhibited reduced abundance of Firmicutes and increased abundance of Proteobacteria. Among the evaluated models, the DHT-only model showed more pronounced metabolic, hormonal, reproductive, and gut microbial alterations and may serve as a suitable model for PCOS research.

Animals

Evaluating 12 automated, whole-genome sequencing analysis pipelines for Mycobacterium tuberculosis complex: a comparative study.

BACKGROUND: Reliance on complex, custom-built bioinformatics pipelines is a barrier to the implementation of whole-genome sequencing (WGS) of Mycobacterium tuberculosis in high-burden settings in some low-income and middle-income countries (LMICs). Automated analysis pipelines could address this inequity in access to WGS-based diagnostics and surveillance. This study aimed to systematically evaluate the performance and usability of publicly available WGS pipelines for M tuberculosis. METHODS: We identified automated M tuberculosis WGS analysis pipelines through searches of PubMed and GitHub from database inception up to Aug 31, 2024. Accuracy, cost, accessibility, and scalability were assessed for each pipeline. We evaluated the accuracy of genotypic drug susceptibility testing (gDST) using publicly available sequences with phenotypic susceptibility data for 12 antituberculosis drugs. We estimated pooled sensitivity and specificity for each pipeline, across all drugs, by conducting a bivariate meta-analysis, with random effects representing between-drug variability. Lineage classifications were compared, and a previously epidemiologically well-characterised dataset was used to compare measures of genomic relatedness. FINDINGS: Among 28 candidate pipelines, 16 were excluded as they were unmaintained and inexecutable. 12 pipelines (11 compatible with Illumina and four compatible with Nanopore), all free to use, were included for evaluation. Six pipelines processed and stored data remotely, but for five of these six, scalability was limited by the need to upload sequences through web portals. For local processing pipelines, scalability was dependent on substantial local computational resources, data storage capacity, and command-line interfaces that limited user-friendliness. Only one of six remote-processing pipelines removed human DNA sequences before server upload. gDST was similarly accurate across ten of 11 Illumina-compatible pipelines and three of four Nanopore-compatible pipelines. All pipelines classified the main lineages consistently, although there were differences at sublineage resolution. Outputs from three of four pipelines reporting genomic relatedness were compatible with commonly cited single nucleotide polymorphism difference thresholds. INTERPRETATION: Numerous automated analysis pipelines capable of enhancing equity in M tuberculosis WGS are available. Given the overall similarities between the pipelines evaluated in this study in terms of gDST performance, lineage classification, and genomic relatedness inference, non-functional attributes such as availability, accessibility, scalability, and privacy could represent the point of difference for prospective users in LMICs with a high burden of tuberculosis. FUNDING: The Rhodes Trust, Wellcome, Ellison Institute of Technology, and the UK National Institute for Health and Care Research Oxford Biomedical Research Centre.

Mycobacterium tuberculosis

Analysis of genomic traits of oral and laryngeal cancer: A comparative study.

Oral and laryngeal cancers exhibit overlapping clinical features but distinct genomic profiles. In a study of 60 Head and neck squamous cell carcinomas(HNSCC) cases (30 OSCC, 30 LSCC), NGS revealed TP53 mutations in 70% of oral squamous cell carcinoma (OSCC) and 83% of laryngeal squamous cell carcinoma (LSCC). CDKN2A alterations were more common in OSCC (40%) than LSCC (20%), while PIK3CA mutations were higher in LSCC (30%). NOTCH1 mutations were more frequent in OSCC (27%) than LSCC (10%). Pathway analysis showed disruptions in p53 and PI3K-Akt, with stronger enrichment in LSCC (ES: 3.42). The results suggest site-specific tumor biology influencing therapeutic targets. Molecular profiling is crucial for precision treatment in head and neck cancers.

Oral cancer

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen® Gel Stent (XEN), or Preserflo® MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at ≥ 12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Astigmatic vector outcomes after FS-LASIK versus SMILE for high myopic astigmatism: a single-center retrospective comparative cohort study without cyclotorsion compensation.

PURPOSE: To compare astigmatic correction vector outcomes between femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE, also termed Keratorefractive Lenticule Extraction, KLEx) without intraoperative cyclotorsion compensation in patients with high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D), and to clarify procedure-specific correction tendencies under this non-standardized alignment protocol. METHODS: This single-center retrospective comparative cohort study enrolled 155 eyes (one eye randomly selected per patient) that underwent FS-LASIK (80 eyes) or SMILE/KLEx (75 eyes) for high myopic astigmatism correction from January 2023 to July 2024 in Beijing Fenglian Jiayue Lige Clinic. Intraoperative cyclotorsion compensation was intentionally disabled to isolate inherent procedural astigmatism correction characteristics. Standardized Alpins vectorial analysis was performed at 3&#xa0;months and 12&#xa0;months postoperatively. PRIMARY ENDPOINT: 12-month Alpins correction index (CI). Multivariable propensity score adjustment was applied to mitigate confounding by clinical treatment selection bias. Statistical multiplicity control was implemented for secondary vector and visual outcomes. RESULTS: Baseline demographic, refractive, corneal and ocular biometric parameters were balanced between groups after propensity matching. No statistically significant intergroup differences were detected in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), residual cylinder, safety index or efficacy index at 3 and 12&#xa0;months (all P&#x2009;>&#x2009;0.05). Under the non-cyclotorsion-compensated protocol, significant intergroup differences were identified in the magnitude of surgically induced astigmatism (SIA), correction index (CI), and magnitude error (ME) at both follow-up timepoints (all P&#x2009;<&#x2009;0.0001). Target induced astigmatism (TIA), difference vector (DV), index of success (IOS), and angle error (AE) magnitudes were comparable between groups (all P&#x2009;>&#x2009;0.05). The vector mean axis of DV differed significantly between groups at 3 and 12&#xa0;months (Watson-Williams circular test, all P&#x2009;<&#x2009;0.0001). No reoperations were documented in clinic medical records for either cohort. No standardized dry eye questionnaires, tear film testing or corneal nerve density metrics were collected to quantify dry eye adverse events; only unstructured clinical notes were reviewed for complication screening. CONCLUSIONS: Under surgical alignment without cyclotorsion compensation, FS-LASIK and SMILE/KLEx both yielded acceptable visual and refractive safety/efficacy for high myopic astigmatism (-&#x2009;2.00 to&#x2009;-&#x2009;3.75 D) at 1-year follow-up, but demonstrated divergent astigmatism correction tendencies: FS-LASIK exhibited relative astigmatism overcorrection (vector mean DV:&#x2009;-&#x2009;0.35&#x2009;&#xb1;&#x2009;0.43 D&#x2009;&#xd7;&#x2009;91&#xb0;, CI&#x2009;>&#x2009;1), while SMILE/KLEx showed relative undercorrection (vector mean DV:&#x2009;-&#x2009;0.21&#x2009;&#xb1;&#x2009;0.53 D&#x2009;&#xd7;&#x2009;12&#xb0;, CI&#x2009;<&#x2009;1). These correction biases are specific to the study's manual limbal alignment protocol without cyclotorsion tracking and cannot be generalized to modern optimized surgical platforms equipped with automated cyclotorsion compensation. Residual refractive errors across both groups are likely multifactorial, including differential corneal stromal healing responses, divergent femtosecond/excimer laser tissue modification mechanisms, and uncorrected intraoperative ocular cyclotorsion.

Humans

Minimally invasive versus open abdominoperineal resection and the risk of postoperative perineal hernia: a systematic review and meta-analysis.

BACKGROUND: The impact of minimally invasive surgery on the risk of postoperative perineal hernia after abdominoperineal resection (APR) or extralevator abdominoperineal excision (ELAPE) remains uncertain. This study compares perineal hernia rates and perioperative outcomes between minimally invasive and open approaches. METHODS: PubMed, Scopus, Web of Science, and Cochrane Library were searched through June 2026. Pooled odds ratios (ORs) and mean differences (MDs) with 95% confidence intervals (CIs) were calculated using random-effects models. A Bayesian meta-analysis was additionally performed for the primary outcome. RESULTS: Four comparative observational studies involving 763 patients were included; 249 underwent minimally invasive APR/ELAPE, and 514 underwent open APR/ELAPE. Postoperative perineal hernia was significantly more frequent following minimally invasive surgery (OR 4.13; 95% CI 2.24-7.61; p&#x2009;<&#x2009;0.001). Intraoperative blood loss was significantly lower in the minimally invasive group (MD&#x2009;-&#x2009;156.5 mL; 95% CI&#x2009;-&#x2009;298.4 to -&#x2009;14.5; p&#x2009;=&#x2009;0.03), as was operative time (MD&#x2009;-&#x2009;41.7&#xa0;min; 95% CI&#x2009;-&#x2009;60.8 to -&#x2009;22.5; p&#x2009;<&#x2009;0.01). No significant differences were observed in hospital stay (MD&#x2009;-&#x2009;2.5 days; 95% CI&#x2009;-&#x2009;5.4 to 0.4; p&#x2009;=&#x2009;0.09) or 30-day readmission rates (OR 1.41; 95% CI 0.82-2.42; p&#x2009;=&#x2009;0.209). Bayesian analysis yielded a posterior mean OR of 4.04 (95% CrI 1.96-8.36), corresponding to a 99.9% posterior probability that minimally invasive surgery increases the risk of postoperative perineal hernia. CONCLUSION: Minimally invasive APR/ELAPE was associated with an increased risk of postoperative perineal hernia compared with the open approach. Strategies to reduce this complication while preserving the benefits of minimally invasive surgery warrant further investigation.

Humans

Endoscopic Ultrasound-Guided Versus Transjugular Portal Pressure Measurements: Systematic Review and Meta-Analysis.

PURPOSE: Published reviews of endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) have emphasized feasibility and safety. We performed a systematic review and meta-analysis specifically to evaluate how closely EUS-based portal pressure measurements track invasive comparator measurements in prospective paired studies and to summarize agreement, technical success, and adverse events. METHODS: We searched major databases through January 2026 for prospective cohorts reporting same-patient EUS-based portal pressure measurement and invasive hemodynamic measurements. Correlations were pooled with random-effects models and analyzed separately for studies comparing EUS-PPG with hepatic venous pressure gradient (HVPG) and studies comparing EUS-based portal measurements with direct portal venous pressure. Agreement and threshold discordance were summarized descriptively. RESULTS: Six prospective cohorts (127 attempted procedures) were included. In studies using HVPG as the comparator, the pooled correlation was 0.82 (95% CI, 0.72-0.89; I2&#x2009;=&#x2009;0%). In studies comparing EUS-based portal measurements with direct portal venous pressure, the pooled correlation was 0.86 (95% CI, 0.72-0.93; I2&#x2009;=&#x2009;16.9%). Technical success was 95.3%. EUS-PPG-attributed adverse events occurred in 2.4% of procedures, with no procedure-related deaths. Agreement data were limited. Reported limits of agreement were wide (approximately -&#xa0;6 to&#x2009;+&#x2009;7&#xa0;mmHg), and discrepancies of 5&#xa0;mmHg or greater occurred in 4 of 30 paired measurements. CONCLUSIONS: EUS-based portal pressure measurement is feasible and shows a strong association with invasive hemodynamic comparators, but the evidence base remains small (six cohorts, 127 attempted procedures). Further study will be necessary to establish patient-level agreement, procedural reproducibility, EUS-specific clinically significant portal hypertension thresholds, and whether HVPG-based decision thresholds can be transferred to EUS-derived measurements.

Humans

Efficacy and safety of thulium fiber laser versus conventional holmium:YAG laser in anatomical endoscopic enucleation of the prostate: a systematic review and pairwise meta-analysis.

PURPOSE: Anatomical endoscopic enucleation is an established treatment for benign prostatic obstruction. Whether thulium fiber laser enucleation (ThuFLEP) improves outcomes over conventional holmium:YAG laser enucleation (HoLEP) remains uncertain. We compared the efficacy and safety of ThuFLEP versus non-MOSES-modulated HoLEP. METHODS: We performed a PRISMA-compliant systematic review and pairwise meta-analysis of randomised and comparative cohort studies comparing ThuFLEP and conventional HoLEP in adult men. Six databases were searched. Outcomes included International Prostate Symptom Score (IPSS), IPSS quality-of-life score, maximum urinary flow rate (Qmax), post-void residual volume, hospital stay, and complications. Risk of bias and certainty of evidence were assessed with RoB 2/ROBINS-I and GRADE. RESULTS: Seven non-overlapping comparative populations in eight publications included 3,509 patients. ThuFLEP was associated with a small statistically significant reduction in IPSS at 3&#xa0;months (mean difference [MD] -1.04 points, 95% confidence interval [CI] -1.81 to -0.28) of uncertain clinical relevance. Qmax differences were small and directionally inconsistent across follow-up (favouring HoLEP at 3&#xa0;months and ThuFLEP at 6 and 12&#xa0;months) and derived mainly from retrospective cohorts, with neutral randomised subgroups. Stress and urge urinary incontinence were less frequent overall (RR 0.75, 95% CI 0.58 to 0.96, and RR 0.39, 95% CI 0.22 to 0.68), but both estimates depended on one large registry cohort and were not robust to its exclusion. Most other complications and hospital stay showed no clear between-group difference. Limitations include few studies per outcome, heterogeneity, sparse safety events, inconsistent prostate-specific antigen reporting, and mostly low/very low certainty evidence. CONCLUSION: ThuFLEP and conventional HoLEP are clinically comparable with no definitive superiority of either laser. Platform selection should be individualised according to surgeon expertise, institutional resources, and patient characteristics. Future trials should standardise cost-effectiveness outcomes and investigate whether the distinct laser-tissue interactions impact adenoma clearance, PSA reduction, enucleation completeness, and long-term durability.

Humans

Comparison of Traditional Chinese Exercise and Equipment-Based Exercise on Glycaemic Control and Vitamin D Levels in Middle-Aged and Elderly Patients With Prediabetes: A Randomised Controlled Trial.

BACKGROUND: Prediabetes is a critical window for preventing progression to type 2 diabetes mellitus (T2DM). Both vitamin D deficiency and physical inactivity are associated with impaired glucose metabolism. This study compared the effects of Traditional Chinese Exercise (TCE) and Kuanle Equipment Exercise (KEE) on glycaemic measures, lipid profiles, body composition and serum 25-hydroxyvitamin D3 [25(OH)D3] in middle-aged and elderly adults with prediabetes. METHODS: We conducted a 12-week, single-centre, randomised controlled trial involving 62 participants with prediabetes (mean age 55.2&#x2009;&#xb1;&#x2009;8.4&#x2009;years; 88.7% female). Participants were randomly assigned to control (usual care, n&#x2009;=&#x2009;21), TCE (n&#x2009;=&#x2009;20), or KEE (n&#x2009;=&#x2009;21). Primary outcomes included fasting plasma glucose (FPG), 2-h OGTT glucose, glycated haemoglobin (HbA1c) and serum 25(OH)D3. Secondary outcomes comprised triglycerides, total cholesterol, LDL-C, HDL-C and body composition. RESULTS: At baseline, mean serum 25(OH)D3 was 21.53&#x2009;&#xb1;&#x2009;3.90&#x2009;nmol/L. At 12&#x2009;weeks, both TCE and KEE improved FPG, 2-h OGTT glucose, HbA1c and 25(OH)D3 versus control (all p&#x2009;&#x2264;&#x2009;0.001). Relative changes in FPG were -9.4% (TCE) and -15.2% (KEE) versus -1.5% (control); corresponding changes were -14.6% and -21.2% for 2-h OGTT glucose, -6.7% and -12.9% for HbA1c, and +60.6% and +81.9% for 25(OH)D3. Direct TCE-KEE comparisons were not significant (all p&#x2009;>&#x2009;0.05). In an exploratory analysis, change in 25(OH)D3 was inversely associated with change in 2-h OGTT glucose (partial r&#x2009;=&#x2009;-0.358, p&#x2009;=&#x2009;0.006), but not with FPG, HbA1c, or triglycerides. CONCLUSIONS: Both TCE and KEE improved glycaemic outcomes and increased serum 25(OH)D3 compared with usual care in middle-aged and elderly adults with prediabetes. Although KEE produced numerically larger estimates, direct between-group comparisons were not significant, and the superiority of KEE over TCE was not established. These vitamin D findings require confirmation in trials that quantify sunlight exposure and dietary vitamin D intake.

Aged

The Efficacy of Erector Spinae Plane Block Versus Subcostal Transversus Abdominis Plane Block in Laparoscopic Nephrectomy: A Randomized Clinical Trial.

OBJECTIVES: This study compared the efficacy and safety of erector spinae plane block (ESPB) versus subcostal transversus abdominis plane (TAP) block in reducing postoperative pain among patients undergoing laparoscopic nephrectomy. METHODS: This randomized clinical trial enrolled 70 adult patients, ASA physical status I or II, who underwent total (radical) laparoscopic nephrectomy under general anesthesia. Patients were randomly assigned to 2 groups. Group ESPB received an ultrasound-guided ESPB at the T7 transverse process level, while group TAP received an ultrasound-guided subcostal TAP block. The primary outcome was the total amount of morphine consumed at 6 and 24 hours postoperatively. Secondary outcomes included the incidence of patients requiring opioid analgesia, time to rescue analgesia, visual analog scale of pain intensity, time to postoperative ambulation, intraoperative and postoperative hemodynamics, arterial partial pressure of oxygen to fraction of inspired oxygen (PaO 2 /FiO 2 or P /F) ratio, and incidence of complications. RESULTS: Compared with the TAP group, the ESPB group exhibited significantly lower median morphine consumption at 24 hours ( P =0.032), prolonged time to first analgesic rescue ( P =0.049), and lower incidence of rescue morphine requirement (OR=0.23; 95% CI=0.06-0.94; P =0.031), with lower visual analog scale pain scores at 12, 18, and 24 hours postoperatively ( P <0.001). The mean arterial blood pressure and heart rates were comparable between groups. No significant adverse effects from either approach. DISCUSSION: In laparoscopic nephrectomy, ultrasound-guided ESPB may safely and effectively be used to improve pain management and reduce pain intensity, with stable hemodynamics and a comparable risk of postoperative complications to the ultrasound-guided subcostal TAP block.

Humans