Ion cyclotron resonance spectroscopy. Cyclotron double resonance provides a new technique for the study of ion-molecule reaction mechanisms.

Ion cyclotron resonance spectroscopy yields information on many aspects of ion-molecule chemistry. The method is ideally suited for experiments involving ion energies below several electron volts, and hence provides a valuable complement to other techniques (27). eyclotron double resonance is uniquely suitable for establishing relationships between reactant ions and their product ions in complex ion-molecule reaction sequences. The double-resonance experiments with isotopic species yield information on reaction mechanisms and the nature of intermediate species. Ion-molecule reactions which occur at low energies are quite sensitive to the nature of functional groups and the details of molecular structure (28). Reactions of ions or neutral molecules with specific reagents in the cyclotron spectrometer can thus be used to characterize unknown species. Once the systematic ion-molecule chemistry of useful reagents has been worked out, it should be possible to proceed in a manner directly analogous to classical chemical methods. Suppose, for example, that reagents A(+), B(+), C(+), and D(+) each have characteristic reactions with different functional groups. Then these reagents can all be mixed with an unknown neutral species, X, and each of the reactions, X + A(+) --> ?, X + B(+) --> ?, . . . . can be examined. In contrast to solution chemistry, all the reagents can be added simultaneously to the unknown, since each of the specific reactions can be examined by cyclotron double resonance. The reactions which occur, the species synthesized , and the products of degradation then characterize X. The same methodology can be applied to characterize an unknown ionic epecies X(+), through use of neutral reagents A, B, C, and D. For example, proton transfer reactions to neuteal species have been applied in studying ions of mass 45 produced from various sources (29). The order of the proton affinities of the neutral reagent molecules are as follows: NH(3) isobutylene propene. Ions of mass 45 can be produced by the protonation of ethylene oxide (see structure III), the protonation of acetaldehyde (see structure IV), and the fragmentation of dimethyl ether (see structure V). Those ions might be expected to have, respectively, the three structures: Proton transfer from the mass-45 ions from sources III and IV to NH(3) and to isobutylene occurs readily, but not proton transfer to propene. For the ion from source V, proton transfer to NH3 occurs, but not proton transfer to isobutylene or propene. Thus the proton transfer reactions to various neutral reagents demonstrate that the mass-45 ions from the various sources are different. This example is only a rudimentary version of an approach to the characterization of unusual ionic species; niore sophisticated applications can follow when the systematic chemistry of more reagents is available. This approach should be ideal for comparing nonclassical carbonium ions produced by different routes. Some very interesting ionic species are produced by rearrangements in the fragmentation of molecules, following electron impact. Such molecular rearrangements frequently result in the fragmentation of an ion radical to another ion radical with the elimination of a small neutral species (30). It should be possible to run these reactions in reverse to check the postulated mechanisms. An interesting result of the systematic study of proton transfer to various functional groups is the finding that the proton affinity of various amines and pyridine is extremely high (31). Species such as VI and VII: might be expected to be very stable; they are in fact so stable that they are unreactive with respect to subsequent chemistry at the charge center. Thus, if there are other functional groups on the ion, the important reactions should occur at these functional groups. It should be possible to design species for which the presence of the charge has little influence on the reactivity of a neutral functional group. In this case the charge functions simply as an inert label which makes the study of neutral-neutral reactions accessible by cyclotron resonance: Various routes for development of the basic technique also appear to be very promising. Echo phenomena following sequences of pulsed excitation have been observed in electron cyclotron resonance (32). Analogous transient phenomena should also occur in ion cvclotron resonances (33). Pulsed-cyclotron-resonance techniques of course have intriguing analogies to nuclear-magnetic-resonance spin-echo experiments (34) and may be the technique of choice for making accurate measurements of ion-molecule-reaction cross sections as a function of energy for low ion energies. Finally, many ion-molecule reactions yield products in excited electronic states (35). For example, the reaction N(2)- + CO --> N(2) + CO- (46) has been studied by beam techniques (36). A straightforward procedure is to observe optical emission from the cyclotron spectrometer by placing a window at the end of the cyclotron cell (37). The emission can be analyzed with a crude set of optical filters, or with a high-speed spectrograph. Optical emission from the cyclotron cell can of course originate from many sources. The radiation from a specific excited product ion can be selected by a radio-frequency-optical double-resonance experiment. If, in the generai reaction A+ + B --> *C+ + D, (47) ion A+ is irradiated at its cyclotron resonance frequency, the number density of optical emitters *C+ is changed. If the irradiating frequency is modulated, then the number of optical emitters will be modulated, so that the intensity of emission from *C+ will also be modulated. When the optical emission from *C+ is analyzed in a spectrograph with a photoelectric cell, the output of the photoelectric cell can be detected with a phase sensitive detector referenced to the modulation frequency. This highly specific modulation-detection scheme should discriminate against other sources of light in the cyclotron cell.

Deuterium↗

Impact of ion cloud densities on the measurement of relative ion abundances in Fourier transform ion cyclotron resonance mass spectrometry: experimental observations of coulombically induced cyclotron radius perturbations and ion cloud dephasing rates.

Fundamental research into the quantitative properties of Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) has yielded interesting observations, especially in terms of factors affecting the accuracy of relative ion abundances. However, most of the previous discussions have focused on theoretical systems, or systems of limited scope. In this paper, we document ion motion attributes of a 30 spectra (six samples, five replicates each) system previously established as linear over two orders of magnitude. Observed behaviors include the perturbation of one charged species (cyclosporin A, CsA) of low ion density to a cyclotron orbit of greater radius than that of an almost identical, but slightly mass-separated species (CsG) with a higher ion density. This radial perturbation is attributed to the coulombic repulsion between the two ion clouds as they interact during the excitation process, as previously proposed by Uechi and Dunbar. Magnitudes of the perturbation were confirmed by making cyclotron radii determinations utilizing the ratio of the third-to-first harmonics for the charged species of interest. It was found that these radial differences can account for as much as a 55% signal bias in favor of CsA for a single sample and a >20% positive bias in the slope of the regressed data set. A second behavior noted that also contributes to the potential inaccuracy of relative ion abundance measurements is the difference in signal decay rates for CsA and CsG. Damping constants and initial time domain signal amplitudes were evaluated using segmented Fourier transforms. Discrepancies in decay rates were not expected from two species that have essentially identical collisional cross-sections. However, it has been observed that the faster decay rates are observed by the species of lower ion cloud density. We have attributed this differential signal decay phenomenon to the rates of loss of phase coherence for the two ion clouds. Previously, others have reported that less dense ion clouds are more susceptible to shearing and other disruptive forces during the course of their excited cyclotron motion. Our experimental evidence supports that it is the loss of cloud coherence that accounts for the signal loss over time, with the less dense cloud de-phasing more quickly. As the ion populations of the two investigated species near equivalence, so do their time constants.

Cyclosporine↗

Tool command language automation of the modular ion cyclotron data acquisition system (MIDAS) for data-dependent tandem Fourier transform ion cyclotron resonance mass spectrometry.

This manuscript describes the addition of data-dependent automation to the modular ion cyclotron resonance data acquisition system (MIDAS). The automation is made possible by developments and incorporation of a tool command language (Tcl) interpreter for automated acquisition. To accomplish the automation, real-time generation of excitation waveforms and scriptable data post-processing has been implemented into the MIDAS source code. In addition a new excitation event has also been added to allow for run-time generation of a single notch stored waveform inverse Fourier transform (SWIFT) excitation event. Examples of these new features and discussion of their enhancement to the existing data station are presented.

Adrenocorticotropic Hormone↗

Cyclotrons and positron emission tomography radiopharmaceuticals for clinical imaging.

Positron emission tomography (PET) requires positron-emitting radionuclides that emit 511-keV photons detectable by PET imagers. Positron-emitting radionuclides are commonly produced in charged particle accelerators, eg, linear accelerators or cyclotrons. The most widely available radiopharmaceuticals for PET imaging are carbon-11-, nitrogen-13-, and oxygen-15-labeled compounds, many of which, either in their normal state or incorporated in other compounds, serve as physiological tracers. Other useful PET radiopharmaceuticals include fluorine-18-, bromine-75-, gallium-68 (68Ga)-, rubidium-82 (82Rb)-, and copper-62 (62Cu)-labeled compounds. Many positron emitters have short half-lives and thus require on-site cyclotrons for application, and others (68Ga, 82Rb, and 62Cu) are available from radionuclides generators using relatively long-lived parent radionuclides. This review is divided into two sections: cyclotrons and PET radiopharmaceuticals for clinical imaging. In the cyclotron section, the principle of operation of the cyclotron, types of cyclotrons, medical cyclotrons, and production of radionuclides are discussed. In the section on PET radiopharmaceuticals, the synthesis and clinical use of PET radiopharmaceuticals are described.

Brain↗

The medical case for an Australian national cyclotron facility.

Both a national cyclotron and a reactor are necessary to provide Australia with the complete range of radioisotopes. For the last 17 years, Australia has been well supplied with reactor radioisotopes by the Australian Atomic Energy Commission which provides a daily nationwide distribution service, but, to be self-sufficient, Australia also needs a national cyclotron. Many cyclotron radioisotopes are too short-lived for importation, and the demand can be met only by domestic production. Despite the availability of the necessary expertise and instrumentation, Australian patients are being denied a wide range of important clinical investigations because of the lack of suitable radioisotopes, for example, krypton-81m and iodine-123. An Australian medical cyclotron is overdue. Australia and New Zealand are the only developed countries that do not possess at least one medical cyclotron. The historical events in Australia's quest for a medical cyclotron are summarized, and the medical reasons why the writers believe that Australia should now acquire its own medical cyclotron are reviewed.

Australia↗

Observation of increased ion cyclotron resonance signal duration through electric field perturbations.

Ion motion in Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is complex and the subject of ongoing theoretical and experimental studies. Two predominant pathways for the loss of ICR signals are thought to include damping of cyclotron motion, in which ions lose kinetic energy and radially damp toward the center of the ICR cell, and dephasing of ion coherence, in which ions of like cyclotron frequency become distributed out of phase at similar cyclotron radii. Both mechanisms result in the loss of induced ion image current in FTICR-MS measurements and are normally inseparable during time-domain signal analysis. For conventional ICR measurements which take advantage of ion ensembles, maximization of the ion population size and density can produce the desired effect of increasing phase coherence of ions during cyclotron motion. However, this approach also presents the risk of coalescence of ion packets of similar frequencies. In general, ICR researchers in the past have lacked the tools necessary to distinguish or independently control dephasing and damping mechanisms for ICR signal loss. Nonetheless, the ability to impart greater phase coherence of ions in ICR measurements will allow significant advances in FTICR-MS research by improving the current understanding of ICR signal loss contributions of dephasing and damping of ion ensembles, increasing overall time-domain signal length, and possibly, resulting in more routine ultrahigh resolution measurements. The results presented here demonstrate the ability to employ a high density electron beam to perturb electric fields within the ICR cell during detection of cyclotron motion, in an approach we call electron-promoted ion coherence (EPIC). As such, EPIC reduces ICR signal degradation through loss of phase coherence, and much longer time-domain signals can be obtained. Our results demonstrate that time-domain signals can be extended by more than a factor of 4 with the implementation of EPIC, as compared to conventional experiments with otherwise identical conditions. The application of EPIC has also been observed to reduce the appearance of peak coalescence. These capabilities are not yet fully optimized nor fully understood in terms of the complex physics that underlies the enhancement. However, the enhanced time-domain signals can result in improved resolution in frequency-domain signals, and as such, this result is important for more efficient utilization of FTICR-MS. High resolution and accurate mass analysis are prime motivating factors in the application of advanced FTICR technology. We believe the approach presented here and derivatives from it may have significant benefit in future applications of advanced FTICR technology.

Bradykinin↗

[Use of a cyclotron in the production of positron emitting radionuclides].

The experience acquired by our center during the first two years of using cyclotron 18/9 (IBA) dedicated to the production of clinical positron emission radionuclides is described. The cyclotron performance characteristics, production yields, quality control and synthesized radiotracers are analyzed. Cyclotron makes it possible to produce up to 3,300 mCi of 18F-, 270 mCi of 18F2, 3,100 mCi of 11C, 502 mCi of 13N (in 120, 60, 35 and 20 minutes respectively) and 540 mCi/min of 15O. In our center, about 85% of the PET studies are performed with 18F-FDG, whereas the remaining are done with 15O-water, 11C-bicarbonate, 11C-methionine, 13N-ammonia or 18F-. Cyclotron is included in the Radiopharmacy Unit of our PET facility and is subjected to a global quality control program. Follow-up of the bombardment parameters and periodic verifications of the cyclotron performance have made it possible to prevent equipment functioning problems, increase mean time between stoppage and decrease downtime. We conclude that cyclotron has high production capabilities and allows enough flexibility for a clinical and research positron emission tomography center; furthermore, it can also be used for regional distribution of 18F-FDG to satellite PET centers.

Carbon Radioisotopes↗

The isochronous cyclotron: principles and recent developments.

The principals of a cyclotron are described. A magnetic field guides the ions in circular paths, while an electric field accelerates them. The main problem in any accelerator is not to accelerate ions, but to focus them. An isochronous cyclotron overrules the problems related to relativistic mass increase during acceleration. Harmonic operation and negative (vs positive) ion acceleration (and extraction) are explained, as they make dedicated PET cyclotrons a simple, reliable, and suitable tool. The characteristics of such PET cyclotrons are described, as well as their technical implementation. The IBA 18/9 PET cyclotron is given as an example.

Carbon Radioisotopes↗

Elimination of frequency drift from Fourier transform ion cyclotron resonance mass spectra by digital quadrature heterodyning: ultrahigh mass resolving power for laser-desorbed molecules.

At sufficiently low pressure, FT-ICR mass resolving power is no longer pressure-limited. Rather, the observed spectral peaks are broadened by ion cyclotron frequency drift during the detection period, due to change in shape of the coherently orbiting ion packet during detection. The frequency drift may be quantitated by Fourier transformation of each of a series of consecutive segments of the time-domain ICR signal, followed by fitting the frequency vs time behavior to a polynomial in time. Correction for that frequency drift is then achieved by a digital quadrature procedure, followed by multiplication by a weight factor which removes the frequency drift. We demonstrate a 750-fold reduction in FT-ICR mass spectral peak width for pseudomolecular (M+K)+ ions of laser-desorbed leucine enkephalin (m/delta m = 1,300,000)! Moreover, correction based on the frequency drift of ions of a given m/z also corrects for frequency drift of ions of other m/z values, as demonstrated for isotopic peaks from (M+K)+ from gramicidin S (m/z 1179). Narrowing of the FT-ICR mass spectral peaks results in a corresponding increase in peak height-to-noise ratio as well. In addition, we propose a theoretical model for frequency drift during detection of the ion cyclotron resonance signal. Simultaneous relaxation of coherent cyclotron motion and compression of the axial distribution of an initially radially coherent ion packet account for ion cyclotron frequency drift during detection. The potential energy generated by mutual ion-ion Coulomb repulsions varies with ion cyclotron orbital radius as ions undergo collisional damping.(ABSTRACT TRUNCATED AT 250 WORDS)

Cyclotrons↗

Decommissioning procedures for an 11 MeV self-shielded medical cyclotron after 16 years of working time.

The present article describes the decommissioning of a compact, self-shielded, 11 MeV medical cyclotron. A Monte Carlo simulation of the possible nuclear reactions was performed in order to plan the decommissioning activities. In the course of the cyclotron dismantling, cyclotron components, shields, and floor concrete samples were measured. Residual activities were analyzed with a Ge(Li) detector and compared with simulation data. Doses to staff involved in the decommissioning procedure were monitored by individual TL dosimeters. The simulations identified five radioactive nuclides in shields and floor concrete: 55Fe and 45Ca (beta emitters, total specific activity: 2.29 x 10(4) Bq kg) and 152Eu, 154Eu, 60Co (gamma emitters, total specific activity: 1.62 x 10(3) Bq kg-1). Gamma-ray spectrometry confirmed the presence of gamma emitters, corresponding to a total specific activity of 3.40 x 10(2) Bq kg-1. The presence of the radioisotope 124Sb in the lead contained in the shield structure, corresponding to a simulated specific activity of 9.38 x 10(3) Bq kg-1, was experimentally confirmed. The measured dose from external exposure of the involved staff was <20 muSv, in accordance with the expected range of values between 10 and 20 muSv. The measured dose from intake was negligible. Finally, the decommissioning of the 11 MeV cyclotron does not represent a risk for the involved staff, but due to the presence of long-lived radioisotopes, the cyclotron components are to be treated as low level radioactive waste and stored in an authorized storage area.

Computer Simulation↗

Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

The basic principles and recent advances in electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry are reviewed. A brief history of electrospray ionization is provided, along with a complete technical description of the technique, electrospray ionization variations, and advantages. Next, the fundamental principles of Fourier transform ion cyclotron resonance mass spectrometry are covered, including ion cyclotron motion, ion cyclotron resonance excitation, and image current detection. Instrumentation and methods used to couple these techniques are then described. Topics include ion source configuration, ion transport through a strong magnetic field gradient, and ion trapping methods. The article concludes with selected applications that highlight the strengths of electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Animals↗

Cyclotron frequency shifts arising from polarization forces.

The cyclotron frequency of a charged particle in a uniform magnetic field B is related to its mass m and charge q by the relationship omega(c) = qB/m. This simple relationship forms the basis for sensitive mass comparisons using ion cyclotron resonance mass spectroscopy, with applications ranging from the identification of biomolecules and the study of chemical reaction rates to determinations of the fine structure constant of atomic spectra. Here we report the observation of a deviation from the cyclotron frequency relationship for polarizable particles: in high-accuracy measurements of a single CO+ ion, a dipole induced in the orbiting ion shifts the measured cyclotron frequency. We use this cyclotron frequency shift to measure non-destructively the quantum state of the CO+ ion. The effect also provides a means to determine to a few per cent the body-frame dipole moment of CO+, thus establishing a method for measuring dipole moments of molecular ions for which few comparably accurate measurements exist. The general perturbation that we describe here affects the most precise mass comparisons attainable today, with applications including direct tests of Einstein's mass-energy relationship and charge-parity-time reversal symmetry, and possibly the weighing of chemical bonds.

Journal Article↗

Relativistic cyclotron resonance shape in magnetic bottle geonium.

The thermally excited axial oscillation of the electron through the weak magnetic bottle needed for the continuous Stern-Gerlach effect modulates the cyclotron frequency and produces a characteristic approximately 12-kHz-wide vertical rise-exponential decline line shape of the cyclotron resonance. At the same time the relativistic mass shift decreases the frequency by approximately 200 Hz per cyclotron motion quantum level n. Nevertheless, our analysis of the complex line shape shows that it should be possible to produce an abrupt rise in the cyclotron quantum number n from 0 to approximately 20 over a small fraction of 200 Hz, when the 160-GHz microwave drive approaches the n = 0 --> 1 transition, and a jump of 14 levels over a frequency increment of 200 Hz has already been observed in preliminary work. This realizes an earlier proposal to generate a very sharp cyclotron resonance feature by quasithermal excitation with a square noise band and should provide a way to detect spin flips when a weak bottle is used to reduce the broadening of the g - 2 resonance by a factor of 20.

Journal Article↗

Measurement of total body nitrogen and oxygen by irradiation with cyclotron neutrons and 'delayed' gamma ray counting.

Measurement of total body nitrogen is assuming increasing importance in the nutritional evaluation of seriously ill patients. Nitrogen has been previously measured either by counting (i) the annihilation radiation from 13N immediately after neutron irradiation with 14 MeV neutrons or (ii) the 'prompt' gamma rays from thermal neutron capture by 14N during irradiation with 14 MeV neutrons or with those produced by isotopic sources or a cyclotron. The present work describes studies into the feasibility of measuring 13N produced by irradiation with a neutron beam from the MRC Cyclotron. A complication of this method is that 13N is also produced in a reaction with 16O. Direct measurement of oxygen by use of the reactions 16O(n, p)16N or 16O(n, 2n)15O enables this interference to be estimated. The former reaction is possible with both 14 meV and cyclotron-produced neutrons but the 7.1 s half-life of 16N requires detectors to be placed in or very close to the irradiation site. In our particular circumstances this is not possible but the more energetic cyclotron neutron spectrum allows the production of 15O which has a half-life of 2.05 min and can be measured in a remote whole-body counter. A disadvantage with the cyclotron beam, in comparison with 14 MeV neutrons, is that a higher dose is required for similar accuracy. A reproducibility of about 4% is obtained with a dose equivalent of 0.01 Sv.

Body Composition↗