Changes in menstrual blood loss after four methods of female tubal sterilization.

One-hundred females requesting tubal sterilization were included in this study. They were enrolled into 4 groups, each n = 25. They were allocated to a particular method of sterilization on a randomized basis. The four modalities used were: laparoscopic Falope ring application, bipolar electrocoagulation, Hulka clip application and Pomeroy tubal ligation via minilaparotomy. The menstrual blood loss (MBL) was quantitatively estimated, using the alkaline hematin method, prior to sterilization and after 3, 6 and 12 months. No significant changes in MBL were observed after the four sterilization techniques. Moreover, they did not differ significantly in this context.

Adult↗

[Comparison of temperature measurements during laparoscopic sterilization and the histologic findings of the cauterized segments of the fallopian tube (author's transl)].

During laparotomies the temperature generated by tubal sterilization with the laparoscopic equipment was measured continually in 32 fallopian tubes. The thermal damage to the fallopian tube caused by different energies and coagulation durations was examined microscopically. During the coagulation of the fallopian tube, with an energy of 20-30 watt temperatures of around 100 degrees C are produced at the point of coagulation. The effective coagulation time is dependant upon the energy created and the duration of the coagulation. The best histologic results were obtained with a duration of the coagulation of 60 seconds at an energy of 30 watts. This corresponds to an effective coagulation time of 50 seconds. The temperature of the coagulation instrument becomes normal within 1 to 2 minutes after the coagulation. If the electric energy is increased to 50 or 100 watt, sparking is observed almost consistently. With these energies, temperatures up to 600 degrees C are observed. The temperature of the metal parts of the coagulation forceps then become normal after 3-4 minutes. In order to avoid burns during laparoscopic tubal sterilizations and in order to obtain a good histologic result the procedure should be done with an electrical energy of 30 watt and a duration of the coagulation of 60 seconds.

Body Temperature↗