PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Electrophoresis, Capillary”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Comparison of enantioseparations using Cu(II) complexes with L-amino acid amides as chiral selectors or chiral stationary phases by capillary electrophoresis, capillary electrochromatography and micro liquid chromatography.

In this paper we report that Cu(II) complexes with L-amino acid amides were used as chiral selectors for enantioseparation by capillary electrophoresis, capillary electrochromatography (CEC) and micro liquid chromatography using chemically modified monolithic columns. The enantioselectivity, enantiomer migration order, and the performance have been compared when different chiral selectors were used in these modes. L-Enantiomers showed longer retention times than D-forms in both CEC and LC modes. However, it has interestingly been observed that the migration order of Dns-DL-Ser showed an exception in CEC using L-prolinamide-modified column that Dns-L-Ser was eluted as the first peak. On the basis of proposed structures of complexes in the chiral recognition, differences in migration orders and recognition mechanism were discussed.

Amides↗

The importance of capillary electrophoresis, capillary electrochromatography, and ion chromatography in separations of inorganic ions.

The importance of capillary electrophoresis (CE), capillary electrochromatography (CEC), and ion chromatography (IC) in inorganic ion analyses is outlined. Methods for improving the reliability of the CE measurements are briefly described. Selectivity optimization in CE analyses of inorganic cations and anions is discussed. Using the Peakmaster program, CE system peaks (system zones, eigenmobilites) and some important CE parameters, such as effective mobilities, electromigration dispersion, indirect UV, and direct conductivity signals, are predicted and compared with experimental analyses.

Chromatography, Liquid↗

Modification of capillary electrophoresis capillaries by poly(hydroxyethyl methacrylate), poly(diethylene glycol monomethacrylate) and poly(triethylene glycol monomethacrylate).

Modification of capillary electrophoresis (CE) capillaries by poly(hydroxyethyl methacrylate) (poly(HEMA), poly(diethylene glycol monomethacrylate) (poly(DEGMA) and poly(triethylene glycol monomethacrylate) (poly(TEGMA), was studied. Methods based on physical adsorption of the modifier and on its chemical binding were compared on the basis of the electroosmotic flow (EOF) reproducibility, the EOF dependence on the pH, the symmetry of the peak of positively charged tyramine, the stability of the coating and the separation of standard and milk proteins in the modified capillaries. Reproducible coatings were obtained by chemical binding of the polymers to the capillary walls and by coating with a solution of a polymer, as also demonstrated by the atomic force microscopy.

Adsorption↗

Isolation and characterization of beta-cyclodextrin sulfates by preparative gradient polyacrylamide gel electrophoresis, capillary electrophoresis and electrospray ionization - mass spectrometry.

A beta-cyclodextrin sulfate mixture has been fractionated using discontinuous gradient polyacrylamide gel electrophoresis. Semidry electrotransfer of the sample onto a positively charged nylon membrane and visualization of a portion of this membrane with Alcian blue stain showed multiple bands. The bands were cut from the remaining portion of the membrane and after washing with 8 M urea, the beta-cyclodextrin sulfate fractions were eluted with 2 M sodium chloride and dialyzed. Analysis of each fraction using high resolution analytical gradient polyacrylamide gel electrophoresis as well as capillary electrophoresis, using indirect detection, showed some of the fractions to be pure while others were mixtures. Each beta-cyclodextrin sulfate fraction was complexed with a basic synthetic peptide and analyzed by electrospray ionization mass spectrometry to define the mass of the components in each mixture and thereby to determine the purity of each sample.

Carbohydrate Sequence↗

Sample preconcentration with chemical derivatization in capillary electrophoresis. Capillary as preconcentrator, microreactor and chiral selector for high-throughput metabolite screening.

New strategies for integrating sample pretreatment with chemical analyses under a single format is required for rapid, sensitive and enantioselective analyses of low abundance metabolites in complex biological samples. Capillary electrophoresis (CE) offers a unique environment for controlling analyte/reagent band dispersion and electromigration properties using discontinuous electrolyte systems. Recent work in our laboratory towards developing a high-throughput CE platform for low abundance metabolites via on-line sample preconcentration with chemical derivatization (SPCD) is primarily examined in this review, as there have been surprisingly only a few strategies reported in the literature to date. In-capillary sample preconcentration serves to enhance concentration sensitivity via electrokinetic focusing of long sample injection volumes for lower detection limits, whereas chemical derivatization by zone passing is used to expand detectability and selectivity, notably for enantiomeric resolution of metabolites lacking intrinsic chromophores using nanolitre volumes of reagent. Together, on-line SPCD-CE can provide over a 100-fold improvement in concentration sensitivity, shorter total analysis times, reduced sample handling and improved reliability for a variety of amino acid and amino sugar metabolites, which is also amenable to automated high-throughput screening. This review will highlight basic method development and optimization parameters relevant to SPCD-CE, including applications to bacterial metabolite flux and biomarker analyses. Insight into the mechanism of analyte focusing and labeling by SPCD-CE is also discussed, as well as future directions for continued research.

Amino Acids↗

Control of electroosmotic flow and wall interactions in capillary electrophoresis capillaries by photografted zwitterionic polymer surface layers.

A novel capillary with covalently bonded zwitterionic surface modification was prepared by photograft polymerization of the zwitterionic monomer N,N-dimethyl-N-methacryloxyethyl-N-(3-sulfopropyl)ammonium betaine, onto the inner surface of a UV-transparent fused-silica capillary. Although the zwitterionic moieties in the resulting polymeric "tentacles" comprise both a positive quaternary ammonium group and a negative sulfonate group, the coating has a net zero charge. The electroosmotic flow (EOF) was therefore extensively suppressed on the grafted capillary compared to the native silica capillary and to the silica capillary that had been activated for graft polymerization by reaction with 3-(methacryloyl)oxypropyltrimethoxysilane. It was also found that the EOF can be varied by adding chaotropic anions or divalent cations such as perchlorate ion and magnesium ion to the running buffer, due to the interaction between these ions and zwitterionic functional group. This provides a new way of altering the EOF and the wall interaction without changing the pH or the overall ionic strength of the separation buffer. The influence of pH and ionic strength of separation buffer on the EOF were also investigated to optimize the separation conditions. Good separations of a mixture containing eight inorganic anions were achieved within 5 min under optimal conditions by capillary zone electrophoresis. The newly prepared capillary was also well suited for the separation of peptides or proteins.

Anions↗

Field amplified separation in capillary electrophoresis: a capillary electrophoresis mode.

In field-amplified injection in capillary electrophoresis (CE), the capillary is filled with two buffering zones of different ionic strength; this induces an amplified electrical field in the low ionic strength zone and a lower field in the high ionic strength zone, making sample stacking feasible. The electroosmotic flow (eof) usually observed in CE, however, displaces the low field zone and induces an extra band broadening preventing any CE separation in the field-amplified zone. These limitations have originated the restricted use of field amplification in CE only for stacking purposes. For the first time, in this work it is theoretically shown and experimentally corroborated that CE separation speed and efficiency can simultaneously be increased if the whole separation is performed in the field-amplified zone, using what we have called field amplified separation in capillary electrophoresis (FAsCE). The possibilities of this new CE mode are investigated using a new and simple coating able to provide near-zero eof at the selected separation pH. Using FAsCE, improvements of 20% for separation speed and 40% for efficiency are achieved. Moreover, a modified FAsCE approach is investigated filling the capillary with the high ionic strength buffer up to the interior of the detection window. Under these conditions, an additional 3-fold increase in sensitivity is also observed. The most interesting results were obtained combining the short-end injection mode and this modified FAsCE approach. Under these conditions, a part of a 3-fold improvement in efficiency and sensitivity, the total analysis time was drastically reduced to 40 s, giving rise to a time reduction of more than 7-fold compared to normal CE. This speed enhancement brings about one of the fastest CE separations achieved using capillaries, demonstrating the great possibilities of FAsCE as a new, sensitive, efficient, and fast CE separation mode.

Journal Article↗

Examination of capillary zone electrophoresis, capillary isoelectric focusing and sodium dodecyl sulfate capillary electrophoresis for the analysis of recombinant tissue plasminogen activator.

The microscale techniques of CZE, cIEF and SDS capillary electrophoresis have been evaluated for the analysis of a complex glycoprotein, recombinant tissue plasminogen activator (rtPA). A series of omega-amino acid buffers (pH approximately 5) was found suitable for the CZE separation of rtPA on coated capillaries. rtPA could be resolved into a series of major and minor peaks in an epsilon-aminocaproic acid buffer containing 0.01% (v/v) Tween 80. For cIEF, a two step method with pressure mobilization was utilized. Using a commercial instrument, either a polymer solution with a 50 microns I.D. capillary or narrow bore capillaries without a polymer solution (25 microns I.D.) were employed. rtPA was resolved into at least eight species within a pI range of 6.4-9.2 using Ampholine 3.5-10. Migration time precision for the major peaks ranged from 0.2% for CZE to < or = 2-3% R.S.D. for cIEF. Total recovery of rtPA from the capillary was also demonstrated for both methods. Analysis of rtPA, rtPA Type I, rtPA Type II and the desialylated forms resulted in the expected elution profiles. Finally, the potential of SDS capillary electrophoresis using a coated capillary for an rtPA Type I/Type II purity assay was shown.

Acetates↗

Two-dimensional capillary electrophoresis involving capillary isoelectric focusing and capillary zone electrophoresis.

Capillary isoelectric focusing (cIEF) and capillary zone electrophoresis (CZE) was on-line hyphenated by a dialysis interface to achieve a 2D capillary electrophoresis (CE) system. The system was used with just one high-voltage power supply and three electrodes (one cathode shared by the two dimensions). The focused zone in the first dimension (i.e. the cIEF) was driven to the dialysis interface by electroosmotic flow (EOF), besides chemical mobilization from the first anode to the shared cathode. And then in the second dimension (i.e. the CZE), the separated zone was further separated and driven by an inverted EOF, which originated from the charged layer of a cationic surfactant adsorbed onto the inner wall of the capillary. Finally, a solution of ribonuclease was rapidly separated to assess the feasibility of the two-dimensional CE implement.

Electrolytes↗

Quaternary structural analysis of nucleoside diphosphate kinases using capillary electrophoresis.

Capillary electrophoresis was used to monitor the quaternary structure and structural changes by denaturants of nucleoside diphosphate kinase (NDP kinase). NDP kinase from human erythrocyte consists of two kinds of polypeptide chains: A (Nm23-H1) and B (Nm23-H2), which are the products of nm23-H1 and -H2 genes, respectively. Structural characteristics of native NDP kinase, recombinant Nm23-H1 and -H2 were examined using capillary electrophoresis employing high pH running buffer in an uncoated fused-silica capillary as a separation column. The results were compared with those of the conventional sodium dodecyl sulfate and non-denaturing polyacrylamide gel electrophoresis. It shows that capillary electrophoresis is a possible tool to investigate protein structure, including the quaternary structure. This protocol was applied to the investigation of the denaturation process of each enzyme by denaturants (6 M urea or heating to 70 degrees C) and to the monitoring of the interaction between denatured Nm23-H1 and -H2. The structural information of NDP kinase obtained by analysis using capillary electrophoresis is valuable for understanding its suggested biological function as a tumor metastasis suppressor and c-myc transcription factor, etc.

Electrophoresis, Capillary↗

Identification of alpha 1-acid glycoprotein (orosomucoid) in human synovial fluid by capillary electrophoresis.

Capillary electrophoresis of human synovial fluid in a phosphate borate run buffer containing sodium dodecyl sulphate separates a hydrophilic glycoprotein, hyaluronan and a number of low-molecular-mass components. The hydrophilic glycoprotein is identified as alpha 1-acid glycoprotein (AGP), orosomucoid, by co-injection methods with human AGP and by reaction with neuraminidase which released N-acetylneuraminic acid. Finally, a sample of the glycoprotein was isolated by micropreparative capillary electrophoresis, examined by sodium dodecyl sulphate-polyacrylamide gel electrophoresis methods and shown to give a positive reaction with AGP antibodies. The peak due to AGP in the capillary electrophoresis is broad and gives evidence for the presence of glycoforms.

Antibodies↗

Detection and identification of monoclonal gammopathies by capillary electrophoresis.

Capillary electrophoresis (CE) and immunosubtraction capillary electrophoresis (IS-CE) were compared with the conventional methods agarose gel electrophoresis (AGE) and immunofixation electrophoresis (IFE) for detection and identification of paraproteins. In total, 74 paraproteins out of 468 serum samples were detected by both methods. Seventy-three monoclonal bands with concentrations ranging from 0.6 to 50.9 g/L were detected by the routine method. With CE, 70 paraproteins were detected and quantified on the electropherogram. Four paraproteins were not detected by CE; three of these were IgG (0.6, 1.1, and 2.2 g/L, respectively), and one was a IgM paraprotein (20.3 g/L) that could be visualized by minor changes in the running conditions. In comparison with IFE, 69 paraproteins were typed identically using IS-CE; only one paraprotein (IgMkappa, 14.9 g/L) could not be identified. On the other hand, a monoclonal IgA band that had not been detected by AGE was identified by CE and IS-CE. We conclude that, in general, CE could be a useful method for detection of paraproteins and that IS-CE is a good alternative to IFE. Additional studies are required to investigate the ionic strength and pH of the running buffer, because these prove to be the most crucial factors for routine CE separation of paraproteins.

Electrophoresis, Agar Gel↗

Ultrasensitive chemiluminescence detection in capillary electrophoresis.

Capillary electrophoresis techniques offer high plate numbers and are highly suited for the efficient separations of a wide variety of chemical components in diverse matrices. Because of the small capillary and detection cell dimensions, together with the minute volumes of samples to be injected, sensitive detection schemes based on different physicochemical principles are being developed. One logical approach to increased sensitivity in capillary electrophoresis detection has been the development of chemiluminescence-based detectors. The development of on-line ultrasensitive chemiluminescence detection (referred to the concentration detection limit of nM order of magnitude or mass detection limit of amol order of magnitude) in capillary electrophoresis system is reviewed. The applications and limitations of the current detection methodology are briefly considered and future prospects for the development are discussed.

Electrophoresis, Capillary↗

Monitoring solution-phase combinatorial library synthesis by capillary electrophoresis.

Capillary electrophoresis has been applied to monitor model reactions in solution-phase combinatorial chemistry. In particular, the simultaneous alkylation reactions of secondary amines with a series of benzyl halides has been investigated. Reactant and product concentrations were monitored using capillary electrophoresis in a non-aqueous buffer system. The simplified sample preparation was a key feature making this an attractive method of analysis. The results demonstrate that capillary electrophoresis is a useful tool for monitoring reactions to determine initial rates, rate constants, and extinction correlation coefficients for quantitative analysis in combinatorial chemistry, and is a broadly applicable technique for the analysis of a variety of organic and bioorganic transformations.

Acetamides↗

Capillary electrophoresis.

Capillary electrophoresis is a rapid and versatile electrophoretic technique that has found several applications in the field of peptide synthesis. The high resolution and charge-based separation capabilities make it very complementary to RP-HPLC. In addition, both are essentially quantitative, which makes them ideal as purity assessment techniques. Capillary electrophoresis can be used to monitor any charge-related changes in synthetic peptides such as incomplete deprotection or chemical modifications. Capillary electrophoresis can also be very sensitive to changes in the shape or size of a peptide. However, its greatest value for the characterization of synthetic peptides is when it is used in combination with other analytical techniques such as mass spectrometry, HPLC, and amino acid analysis.

Amino Acid Sequence↗

Quantification of serum proteins using capillary electrophoresis.

Capillary electrophoresis is a technique that can be automated for the separation of charged particles. By investigating suitable sample dilution and injection time and adhering to a strict washing procedure we have been able to quantify paraproteins in serum samples. This has enabled us to use the technique of capillary electrophoresis for the provision of serum protein electrophoresis in a routine clinical laboratory. We present our findings of 260 serum samples, which included 76 samples with paraproteins analysed by both capillary electrophoresis (EC) and high resolution agarose gel electrophoresis (HRAGE). CE was able to detect all the monoclonal bands detected by HRAGE, and in particular, better able to detect IgA monoclonal bands occurring in the beta region. The major advantages of CE over HRAGE relate to the automated nature of CE with the elimination of the need for a densitometer.

Blood Protein Electrophoresis↗

Routine differential diagnosis of proteinurias by capillary electrophoresis.

Capillary electrophoresis is a relatively new analytical technique that begins to have an impact on both routine and research in clinical laboratories. Recently, a fully automated system has become commercially available (Paragon CZE 2000, Beckman, USA) for the analysis of human serum proteins. Urine protein analysis, on the other hand, is currently accomplished by electrophoresis of concentrated urine specimens. The method is used to distinguish the glomerular from the tubular proteinuria and for the identification of Bence-Jones proteins. The procedure is labor-intensive and technically demanding. We developed a technique for the serum capillary electrophoresis instrument that can also be applied routinely to the differential diagnosis of proteinurias. Overriding the programmed dilution step of the instrument, we were able to distinguish different types of proteinurias without concentration of specimens with a total protein content of 150-200 mg/l as determined by sulfosalicylic acid. The different electrophoretic patterns obtained by the capillary electrophoresis system for various specimens correlated well with established techniques (Hydragel Proteinurie Kit, Sebia, France). The method is applicable for routine analysis of urinary proteins. It is reliable, less expensive and faster than the conventional methods (electrophoretic or immunonephelometric) used today for the differentiation of proteinurias, and it can be used as a quick screening test.

Albuminuria↗