PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fitting--complications”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

12 recordsLinked to original sources

Model-based screening by risk with application to Down's syndrome.

Screening for a disorder may be carried out by assessing the risk that an individual is affected given the values of variables whose distributions alter when the disorder is present. An optimal screening policy is obtained by identifying those individuals whose risk is greater than some cut-off value. This paper summarizes the way in which risk is derived from the likelihood ratio of being affected by the disorder, and compares three different methods of estimating the likelihood ratio, namely direct estimation, logistic regression and distribution modelling. For continuous variables that have a multivariate normal distribution, screening by risk is equivalent to the use of quadratic discrimination. The paper shows how estimates of the risk and associated detection and false positive rates can be derived for a screening policy which uses specified risk cut-offs. Screening by risk has the counter-intuitive property that as the separation in the distribution of screening variables between affected and unaffected individuals increases, the detection and false positive rates may both increase. The approach is explored using data on antenatal screening for Down's syndrome. The method of choice is model-based; the model is described and tested for goodness of fit. Complications arising from outliers and non-normality must be overcome before an appropriate assessment of risk can be made. The concept of shrinkage is used to estimate the detection of false positive rates that may be expected in a new data set.

Confidence Intervals↗

Vaginal pessaries in managing women with pelvic organ prolapse and urinary incontinence: patient characteristics and factors contributing to success.

OBJECTIVE: An aging population has resulted in higher prevalence of urinary incontinence (UI) and pelvic organ prolapse (POP). This study examines a nurse-run clinic and analyzes the factors contributing to successful pessary use. STUDY DESIGN: A retrospective chart review of 1,216 patients was completed. History, pelvic examination and pessary fitting was done. Data was analyzed utilizing a categorical model of maximum-likelihood estimation to investigate relationships. RESULTS: Median patient age was 63 years. Median number of pessaries tried was two. Eighty-five percent of post-menopausal women were on hormone replacement therapy (HRT) prior to fitting. Highest success rate of 78% was in the group on both systemic and local HRT. Success rates ranged from 58% for urge incontinence to 83% for uterine prolapse. Prior vaginal surgery was a factor impacting success. In our series highest success rates for fitting were obtained with ring pessaries, ring with support, and gellhorns. CONCLUSIONS: This model is a viable, option for the conservative management of UI and POP. Local HRT plays an important role in successful pessary fitting. Complications are rare.

Adult↗

Total artificial heart bridge to transplantation: a 9-year experience with 62 patients.

BACKGROUND: The SynCardia CardioWest total artificial heart (CardioWest TAH) is a biventricular, orthotopic, pneumatic, pulsatile blood pump driven by an external console. For each ventricle, the length of the blood-flow path is shorter and the inflow and outflow valves are larger than in any other bridge-to-transplant device, resulting in greater blood flow at smaller pre-load. Such a device should be optimal for bridging transplant candidates who have biventricular failure and for whom all other therapies have failed. METHODS: From January 1, 1993, to April 1, 2002, we prospectively studied 62 consecutive CardioWest TAH implant recipients to document safety and efficacy in bridge to transplantation. We used multisystem monitoring and multidrug therapy for anti-coagulation in 58 patients starting September 1, 1994. RESULTS: Before implantation, patients were critically ill with biventricular heart failure. Mortality in this group from the time of implantation until transplantation was 23%. Causes of death during device support included multi-organ failure (6), sepsis (3), and valve entrapment (2). Forty-eight patients underwent transplantation (77%). Forty-two survived to hospital discharge (68% of the total, 88% of those undergoing transplantation). Adverse events included bleeding (20%), device malfunction (5%), fit complications (3%), mediastinal infections (5%), visceral embolus (1.6%), and stroke during support (1.6%). The linearized stroke rate was 0.068 events per patient-year. CONCLUSIONS: Sixty-eight percent of critically ill transplant candidates for whom medical therapy failed were bridged to transplantation with the CardioWest TAH and survived long-term. Most deaths that occurred during device support were related to pre-implant problems. Infection and stroke were rare events. Therefore, we recommend the CardioWest TAH as the biventricular bridge-to-transplant device of choice.

Adolescent↗

West syndrome: individualized ACTH therapy.

Individualized ACTH treatment of the West syndrome (WS) was assessed in a prospective multicenter study, in which each patient's dosage was increased stepwise according to response. Our series included six patients with cryptogenic and 24 with symptomatic infantile spasms. During the treatment period the total ACTH dose ranged from 58 to 373 i.u./kg. In the cryptogenic group one patient responded to pre-ACTH pyridoxine and four to the lowest dosage of ACTH (3 i.u./kg daily) with cessation of spasms and good outcome; one patient needed the highest dosage (12 i.u./kg daily) for cessation of seizures and became developmentally retarded. In the symptomatic group, 21 of the 24 patients needed 6-12 i.u./kg daily; 12 became seizure-free or having infrequent non-IS fits. Complications such as arterial hypertension, cerebral ventricle dilatation, cardiac hypertrophy, and prolonged adrenocortical hyporesponsiveness were related to the dose. The individualization provides all the benefits of ACTH treatment with minimal side effects and cost.

Adrenocorticotropic Hormone↗

Keratoconus fittings: apical clearance or apical support?

PURPOSE: To examine the relative merits of apical support and apical clearance fitting of rigid gas-permeable contact lenses for keratoconus. METHODS: After an historic review of fitting approaches for keratoconus, a case report is described in which an adventitious apical clearance fitting for early keratoconus might have been associated with accelerated progress of the ectasia. DISCUSSION: The hypothesis that apical clearance fittings increase the risk of accelerating ectasia progression in early keratoconus is examined in counterpoint to the hypothesis that apical support fittings increase the risk of apical scarring. Reference is made to the responses of normal corneas to apical clearance fitting and to apical contact fittings used in orthokeratology fittings. The tendency for corneas to mold to contact lens curvature is reviewed. The possibility that reduced corneal thickness or tissue softening and associated changes to the biomechanical properties of the cornea in keratoconus may facilitate molding with apical clearance fitting is examined. CONCLUSIONS: Known and putative risk factors for fitting complications that are associated with apical clearance and apical touch contact lens fitting are given as a basis for the reader to draw conclusions about the management of contact lens fitting for keratoconus. The possibility of symptomless adverse responses is a strong indication for frequent routine aftercare reviews.

Child↗

Intraocular lenses versus extended-wear contact lenses in aphakic rehabilitation. A controlled clinical study.

A controlled clinical study with random allocation of method of rehabilitation (lens implant or contact lenses) was designed for comparative outcome assessments. Sixty-one patients were included in the study: 31 patients randomized to lens implantation and 30 patients to extended-wear contact lens rehabilitation with early post-operative fitting. Complication rates were low in both groups with slight accumulation of intraocular complications in the implant group and of external complications in the contact lens group. We found no significant differences between the groups in final visual acuity, in vision dependent practical functioning, or in patients' contentment. Two main points summarize our results and impressions from this study: At the expense of a slightly higher risk the lens implant patients get the most convenient and comfortable rehabilitation and at the expense of frequent visits for follow-up and lens cleaning the contact lens patients get the safest rehabilitation. The patient offered contact lens rehabilitation should be capable of alert cooperation, fairly mobile and living within easy access to ophthalmic service, while the patient offered lens implant does not need to fulfill these criteria.

Aged↗

Parental attitudes towards epilepsy.

Parents of 352 children with history of epilepsy were interviewed by a pretested, open ended questionnaire to ascertain the nature of first aid care during an epileptic fit, complications arising out of this care, and parents' perceptions regarding causes of epilepsy. The commonest form of care provided was to force liquids by mouth (50.6%), followed by pressure over body to restrain convulsive movements (13.0%) or to put some object to force the teeth open (11.9%). The various causes of epilepsy according to the parents were: due to an evil spirit (26.7%0, heritable causes (13.9%), physical or mental weakness (6.6%) and brain damage (5.9%). The need of imparting knowledge and clear understanding about epilepsy among parents is emphasized.

Adolescent↗

A categorical approach to the diagnosis and management of pre- and post-fit contact lens conditions.

There are two essential elements in the successful management of contact lens wear. First, it is necessary to pre-assess common anterior segment disorders which may interfere with wear. Such conditions often require pre-wear remediation and special fitting considerations. Second, post-fit complications must be accurately evaluated regarding risk, etiology and prognosis. Appropriate treatment and follow-up for such complications usually results in continued, successful wear. This paper presents tables including diagnostic and management high-lights of the more common complications. Each table is subdivided into anatomical, diagnostic (alphabetical listings) etiological and risk factor categories for practical referencing.

Conjunctival Diseases↗

Surgical positioning of the Jarvik-7 artificial heart.

The Jarvik-7 total artificial heart has been implanted in 18 patients at the time of this writing. Eleven patients received the 100 ml heart, and the remaining seven were treated with the 70 ml device. To date, five patients have been implanted for permanent use with an average survival in excess of 9 months, and the longest survival is more than 1 1/2 years following implantation of the heart. Complications related to positioning were a contributing factor in the death of one patient. Thirteen patients have received the Jarvik-7 heart as a bridge to transplant. Three died before transplant, and the remaining ten have been transplanted. To date, all are alive, several are home and in excellent condition, and several are still hospitalized but are expected to be released shortly. Three patients have experienced serious complications after transplantation. One patient rejected her heart transplant, was reimplanted with the artificial heart, and now has been sustained for more than 3 months. At this time she is in good condition awaiting a second donor. Selection of the appropriate size Jarvik-7 artificial heart for the individual patient can best be made based on measurements of thoracic dimensions obtained from a computed tomography scan and calculation of body surface area. The appropriate medial or lateral positioning can be determined and decisions concerning the lengths of the grafts and cuffs, excision or nonexcision of the left pericardium, and air drive line position can be made. The Jarvik-7 heart can be successfully used in patients from 50 kg. However, at the lower size limit in patients from approximately 50 to 65 kg, the risk of fit complications is the greatest and availability of an even smaller model heart would be desirable.

Adult↗

International experience with the CardioWest total artificial heart as a bridge to heart transplantation.

As the number of potential heart donors remains constant and the number of potential recipients continuous to increase, the need for circulatory devices to bridge patients becomes more important. The CardioWest total artificial heart (TAH) is a pneumatic, implantable system that totally replaces the failing ventricles. It has been utilized worldwide as a bridge to heart transplantation in 79 patients. There were 73 males and six females who received the TAH. Currently three patients remain on the device waiting for transplantation. A total of 55 patients (70%) were transplanted of which 50 survived (91% of patients transplanted) and were discharged home. Idiopathic/dilated cardiomyopathy was the most common etiology followed by ischemic cardiomyopathy. The mean duration of implant was 34 days (range 0-186 days) and the mean age of the group was 45 years (range 16-62 years). Twenty-one patients died while on the device. Multiple organ failure was the major cause of death. There were a total of 255 complications in this group that included reoperation, bleeding, hepatic failure, renal failure, respiratory failure, neurologic events, thromboembolic events, infections, device malfunction, and fit complications. This represented a mean complication rate of three events per patient. The survival rate for the CardioWest TAH of 91% of the patients who reached transplantation is an improvement over that of the Symbion registry (55% of those transplanted) probably as a result of a better patient selection and better control of the coagulation system. These results are also comparable to those survival results obtained with other biventricular and left ventricular assist devices currently available.

Adolescent↗

Intrauterine devices.

Explore the source record for details and available documents.

Dysmenorrhea↗